BEGA 85 023 UniLink Compact Floodlight Instruction Manual
- June 1, 2024
- BEGA
Table of Contents
BEGA 85 023 UniLink Compact Floodlight
Product Information
Specifications
- Model: 85 023
- Power Consumption: 0.14 A
- Lamp Module Connected Wattage: 24.1 W
- Luminaire Connected Wattage: 27 W
- Colour Temperature: 3000 K (LED-0800/930)
- Colour Rendering Index (CRI): > 90
- Module Luminous Flux: 3350 lm
- Luminaire Luminous Flux: 2472 lm
- Luminaire Luminous Efficiency: 91.6 lm/W
Product Usage Instructions
Safety
The installation and operation of this luminaire are subject to national
safety regulations. The manufacturer accepts no liability for damage caused by
improper use or installation. If subsequent modifications are made to the
luminaire, the person responsible for these modifications shall be considered
the manufacturer.
Overvoltage Protection
The electronic components installed in the luminaire are protected against
overvoltage in accordance with DIN EN 61547. To achieve additional protection
against transients, it is recommended to use separate overvoltage protection
components.
Adjustment of Beam Direction
To adjust the beam direction, undo the joint screw using a hexagon socket
head wrench size 5 mm, set the desired beam direction, and then tighten the
joint screw.
Note: Do not remove the desiccant bag from the luminaire housing as it is needed to remove residual moisture.
Maintenance
The connecting cable must be checked for external damage regularly and may
only be replaced by a qualified electrician.
Accessories
- 71 247 – 5m connecting cable with free cable ends
- 71 256 – 0.5m connecting cable with free cable ends
- 71 280 – Shield
- 71 285 – Cylindrical shield
- 71 290 – Exchangeable lens flat beam
- 71 180 – Plug type F/E (Germany and Europe)
- 71 181 – Plug type G (Great Britain)
FAQs
-
Q: Can I use a different wattage lamp module with this luminaire?
A: It is recommended to use the specified lamp module connected wattage to ensure proper functionality and safety. -
Q: How do I clean the luminaire?
A: Use a soft, dry cloth to wipe the luminaire. Do not use any liquid or abrasive cleaners.
Compact floodlight BEGA UniLink®
Instructions for use
Application
Portable compact floodlight BEGA UniLink® with earth spike and 5 m connecting
cable with plug connector.
A separate mains plug must be ordered in order to connect the floodlight to
the mains. The various country-specific mains plugs with 0.5 m connecting
cable, as well as extension cables and five-way distribution boxes are
available as accessories.
Product Description
- Floodlight made of aluminium alloy, aluminium and stainless steel
- BEGA Unidure® coating technology
- Colour graphite
- Earth spike made of glass fibre reinforced synthetic material
- Safety glass with optical structure
- Silicone gasket
- Reflector surface made of pure aluminium Swivel range -55°/+70°
- 5 m mains supply cable
- X05RN-F FEP 2 × 1@ + 1G2,5@ with plug-in connector
- Complies with flicker requirements in accordance with IEEE 1789,
- DIN IEC/TR 63158, DIN IEC/TR 61547-1 LED power supply unit
- 220-240 V 50/60 Hz
- BEGA Thermal Switch®
- Temporary thermal shutdown to protect temperature-sensitive components
- Safety class I
- Protection class IP 65
- Dust-tight and protection against water jets Impact strength IK07
- Protection against mechanical
- impacts < 2 joule
- – Conformity mark
- Weight: 2.2 kg
- This product contains light sources of energy efficiency class(es) E
Safety
- The installation and operation of this luminaire are subject to national safety regulations.
- The manufacturer accepts no liability for damage caused by improper use or installation. If subsequent modifications are made to the luminaire, the person responsible for these modifications shall be considered the manufacturer.
Total load
When configuring your lighting system, please ensure that the maximum power
consumption of 6 A is not exceeded. Information on power consumption can be
found in the instructions for use and data sheets for all BEGA UniLink®
luminaires.
Power consumption of 85 023: 0,14 A
Lamp
- Module connected wattage 24.1 W
- Luminaire connected wattage 27 W
- Rated temperature = 25 °C
- Ambient temperature = 25 °C
85 023 K3
- Module designation LED-0800/930
- Colour temperature 3000 K
- Colour rendering index CRI > 90
- Module luminous flux 3350 lm
- Luminaire luminous flux 2472 lm
- Luminaire luminous efficiency 91,6 lm / W
85 023 K4
- Module designation LED-0800/940
- Colour temperature 4000 K
- Colour rendering index CRI > 90
- Module luminous flux 3400 lm
- Luminaire luminous flux 2509 lm
- Luminaire luminous efficiency 92,9 lm / W
Light technique
Symmetrical wide beam light distribution
Half beam angle 45°
The symmetrical light cone can be modified to resemble flat beam light
distribution for special lighting applications by replacing the cover glass.
Overvoltage protection
- The electronic components installed in the luminaire are protected against overvoltage in accordance with DIN EN 61547.
- To achieve an additional protection against e. g. transients, etc. we recommend separate overvoltage protection components.
- You can find them on our website at www.bega.com.
- The ideal protection of all electronic components installed in the luminaires is achieved by using bounce-free switching contacts such as an electronic relay (solid-state relay), e.g. BEGA 71 320.
Caution
The BEGA UniLink® plug connectors may only be connected and disconnected in a
voltage-free state.
Installation
Press the luminaire with earth spike vertically into the soil until stability
is achieved. If necessary, compact soil around the earth spike.
Plug the floodlight’s connecting cable into the plug contact of the connecting
cable with the country-specific mains plug, or into the distribution box or
extension cable.
To ensure a sufficiently low protective conductor resistance (loop
resistance), the connecting cable of each luminaire in the system must not
exceed a length of 50 m from the entry point.
Adjustment of beam direction
Undo joint screw (hexagon socket head wrench size 5 mm) and set the desired
beam direction.
Tighten the joint screw.
Please note
- Do not remove the desiccant bag from the luminaire housing.
- It is needed to remove residual moisture.
Cleaning · Maintenance
- Clean luminaire regularly with solvent-free cleansers from dirt and deposits.
- Do not use high pressure cleaners.
Maintenance
The connecting cable must be checked for external damage and may only be
replaced by a qualified electrician.
Replacing the LED module
- The designation of the LED module is noted on a label in the luminaire.
- The light colour and light output of BEGA replacement modules correspond to those of the modules originally fitted.
- The module can be replaced by qualified persons using standard tools.
- Disconnect the system and open the luminaire. Please follow the installation instructions for the LED module.
- Inspect and, if necessary, replace the luminaire gaskets.
- Defective glass must be replaced.
- Close the luminaire.
Accessories
- 71 280 Shield
- 71 285 Cylindrical shield
- 71 290 Exchangeable lens flat beam 0.5 m connecting cable with country-specific mains plugs
- 71 180 Plug type F / E: system common in Germany and Europe
- 71 181 Plug type G: system used in Great Britain (“Commonwealth plug”)
- 71 182 Plug type J: system common in Switzerland and Liechtenstein
- 71 183 Plug type L: system common in Italy and Greece
- 71 184 Plug type K: system common in Denmark and Greenland
- 71 186 BEGA UniLink® Extension cable 5 m 71 187 BEGA UniLink® Extension cable 10 m
- 71 188 BEGA UniLink® Extension cable 20 m
- 71 247 Connecting cable 5 m with free line ends
- 71 256 Connecting cable 0.5 m with free line ends
- 71 189 BEGA UniLink® Five-way distribution box
For the accessories a separate instructions for use can be provided upon request.
Spares
- Trim ring graphite with glass 25 000 234
- LED power supply unit DEV-0352/700
- LED module 3000 K LED-0800/930
- LED module 4000 K LED-0800/940
- Reflector 75 005 075
- Gasket housing 83 002 022
- Gasket glass 83 002 222
BEGA Gantenbrink-Leuchten KG · Postfach 31 60 · 58689 Menden · info@bega.com · www.bega.com
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>