“`html
Product Specifications
-
Product Name: 6-inch LED Downlight and Wall Wash
-
Models: HC6, HM6, 61, 61PS
-
Lumen Options: 500 lm to 6000 lm
-
Driver Options: D010, D010347, D010X347, DLV
-
Emergency Battery Pack Options: REM7, REM14, IEM7, IEM14,
BOD7ST, REMV7, REMV14, IEMV7, IEMV14 -
Control Compatibility: WaveLinx LITE, WaveLinx PRO
Product Usage Instructions
Mounting Frame Installation
-
Identify the appropriate mounting frame based on your
requirements. -
Ensure the lumens and driver options match your setup.
-
Follow the provided instructions for installing the mounting
frame securely.
LED Module Installation
-
Select the LED height based on your ceiling thickness and
desired light output. -
Carefully insert the LED module into the designated slot in the
mounting frame. -
Ensure a secure fit to prevent any movement during
operation.
Control Compatibility Setup
-
If using WaveLinx LITE or PRO, refer to the respective control
system manual for setup instructions. -
Connect the downlight to the control system following the
recommended wiring diagram. -
Test the control system to ensure proper functionality with the
LED downlight.
Emergency Battery Pack Installation
-
If adding an emergency battery pack, select the appropriate
wattage and type based on your needs. -
Install the emergency battery pack according to the provided
instructions and wiring diagram. -
Regularly test the emergency lighting functionality to ensure
readiness in case of power outages.
Frequently Asked Questions (FAQ)
Q: Can I use a different driver option than the ones
listed?
A: It is recommended to use one of the specified driver options
for optimal performance and compatibility with the LED
downlight.
Q: How do I determine the appropriate lumen output for my
space?
A: Consider factors such as room size, ceiling height, and
desired brightness level when selecting the lumen option for your
LED downlight.
Q: Are the emergency battery packs compatible with all
models?
A: Some emergency battery pack options are not available for
certain models, so refer to the compatibility list before making a
selection.
“`
Project Prepared by
Catalog # Notes
Type Date
HC6 | HM6 | 61 | 61PS
6-inch LED downlight and wall wash
Typical Applications Office · Healthcare · Hospitality · Institutional · Mixed-Use/Retail
Interactive Menu
· Order Information page 2 · Product Specifications page 4 · Photometric Data
page 5 · Energy & Performance Data page 8 · Connected Systems page 10 ·
Product Warranty
Product Certification
Top Product Features
· New construction/remodel series; 500 to 6,000 lumens · Narrow, Medium and
Wide distributions; Wall wash with rotatable linear spread lens · 2700K,
3000K, 3500K, 4000K, 5000K CCT; 80 or 90 CRI · Universal voltage 120V-277V;
Standard 0-10V driver dims to 1% · Mounting frame converts to remodel that
installs from below the ceiling · Quick Spec emergency backup mounting frames
– fast delivery option
Product Features
Control Compatibility
WaveLinx LITE
WaveLinx PRO
Dimensional and Mounting Details
26.4″ [670.56mm] 8.6″ [217.35mm]
NEW CONSTRUCTION – MID LUMEN 3000 AND 4000 LUMEN
max module height (see table)
LED height (see table) 3.42″
[86.77mm] (driver height)
.5″ [12.70mm] (ceiling thickness)
Mid Lumen (3000 4000 Lumens)
6.06″ [153.92mm] (reflector inner aperture)
7.25″ [184.15mm] (ceiling cut out)
7.75″ [196.85mm] (trim flange)
Distribution Narrow Medium Wide Baffle
Max. Module Height
Trim Height
6.6″
3.4″
6.7″
3.5″
6.5″
3.3″
LED Height
3.8″ 3.9″ 3.7″
6.5″
3.3″
3.7″
additional product diagrams
trim height (see table)
PS517016EN page 1
March 8, 2024 6:07 PM
Mounting Frame Order Information
Sample Number: HC620D010REM7 HM60525835 – 61MDC A complete luminaire
consists of a housing frame, LED module, and reflector (ordered separately)
HC6 | HM6 | 61 | 61PS
Mounting Frame
Lumens
Driver Options
Factory Installed Emergency & Connected Lighting Options
Accessories (Order & Install Separately)
HC6 = 6″ new construction downlight housing HC6CP = 6″ new construction
housing, Chicago Plenum – CCEA compliant
Notes
05 = 500 lm 07 = 750 lm 10 = 1000 lm 15 = 1500 lm 20 = 2000 lm 25 = 2500 lm 30
= 3000 lm 35 = 3500 lm 40 = 4000 lm 45 = 4500 lm (7) 50 = 5000 lm (7) 55 =
5500 lm (7) 60 = 6000 lm (7)
Notes (7) Marked Spacing: Center to Center of Adjacent Luminaires = 36″ Center
of Luminaire to Building Member = 18″ Minimum overhead = 0.5
D010=UNV 120-277V, 50/60Hz, 0-10V 1%-100% dimming at 120-277V on 0-10V
controls
Canada Option 500-5000 lumens: D010347 = 347VAC 50/60Hz 0-10V 1%100% dimming.
For 500, 750, 1000, 1500, 2000, 2500, 3000, 3500, 4000, 4500, 5000lm models
only (1)
Canada Option 5500-6000 lumens: D010X347 = step down transformer factory
installed (with standard “D010″ 120V-277V LED driver). For 5500, 6000lm models
only (1)
DLV = Distributed Low Voltage dimming driver 1%-100%, 1000-4000 lumens only.
For use with DLVP system only, refer to DLVP specifications for details. (1)
Notes (1) Not available with CP models
REM7 = 7 watt emergency battery pack with remote test / indicator light, use
with D010 only (1) (2) (6)
REM14 = 14 watt emergency battery pack with remote test / indicator light, use
with D010 only (1) (2) (6)
IEM7 = 7 watt emergency battery pack with integral test / indicator light, use
with D010 only (1) (2) (6)
IEM14 = 14 watt emergency battery pack with integral test / indicator light,
use with D010 only (1) (2) (6)
BOD7ST = 7.5 watt Bodine self-test emergency battery pack with remote test /
indicator light, use with D010 only (1) (2) (6)
WTA = Factory WaveLinx Tilemount Sensor Kit (4)
WTK = Factory WaveLinx LITE Commercial Tilemount Sensor Kit (5) WPN = WaveLinx
PRO Wireless Node without sensor (9) WLN = WaveLinx LITE Wireless Node without
sensor (10)
REMV7 = 7 watt emergency battery pack with remote test / indicator light, use
with DLV only (1) (2) (3) (6)
REMV14 = 14 watt emergency battery pack with remote test / indicator light,
use with DLV only (1) (2) (3) (6)
IEMV7 = 7 watt emergency battery pack with integral test / indicator light,
use with DLV only (1) (2) (3) (6)
IEMV14 = 14 watt emergency battery pack with integral test / indicator light,
use with DLV only (1) (2) (3) (6)
Notes
(1) Not available with CP models (2) Not available with D010347 (347V models)
(3) ULus for U.S. only (4) WTA = WaveLinx tilemount sensor kit for daylight
dimming, PIR motion sensing, and optional RLTS – Real Time Location Services,
use with D010 only (Refer to WaveLinx specifications) (5) WTK = WaveLinx LITE
tilemount sensor kit for daylight dimming, PIR motion sensing, use with D010
only (Refer to WaveLinx LITE specifications) (6) Emergency battery backup
options are Non-IC only, and rated for a minimum starting temperature of 0°C
(9) WPN = WaveLinx PRO wireless node provides luminaire-level control with
scene and zone configuration without an integrated sensor; Connects wirelessly
with daylight dimming sensor and PIR motion sensor if desired. Use with 0-10V
driver only. (10) WLN = WaveLinx LITE wireless node provides luminaire-level
control with scene and zone configuration without an integrated sensor;
Connects wirelessly with daylight dimming sensor and PIR motion sensor if
desired. Use with 0-10V driver only.
HB128APK = L channel hanger bar, 26″, pair (replacement) RMB22 = Adjustable
wood joist mounting bars, pair, extend to 22″ long HSA6 = Slope Adapter for 6″
Aperture Housings, Specify Slope (refer to instructions for installing housing
and trim) H347 = 347 to 120V step down transformer, 75VA H347200 = 347 to 120V
step down transformer, 200VA WTA = Field WaveLinx Tilemount Sensor Kit (4) WTK
= Field WaveLinx LITE Commercial Tilemount Sensor Kit (5)
Notes (4) WTA = WaveLinx tilemount sensor kit for daylight dimming, PIR motion
sensing, and optional RLTS – Real Time Location Services, use with D010 only
(Refer to WaveLinx specifications) (5) WTK = WaveLinx LITE tilemount sensor
kit for daylight dimming, PIR motion sensing, use with D010 only (Refer to
WaveLinx LITE specifications)
Quick Spec Emergency Mounting Frame Order Information
Sample Number : Quick Spec Emergency Mounting Frame: RR-HC620D010REM7 LED
module and reflectors are ordered separately. Order separately: LED Module:
HM60525835 | Reflector: 61MDC
Select from the Quick Spec Mounting Frame ordering information to receive the
Fast Delivery option for the frame.
Quick Spec Code
Mounting Frame
Lumens
RR = East Region BRR = West Region
HC6 = 6″ new construction downlight housing
10 = 1000 lm 15 = 1500 lm 20 = 2000 lm 30 = 3000 lm 40 = 4000 lm
Notes
Notes
Notes
Driver Options
D010=UNV 120-277V, 50/60Hz, 0-10V 1%-100% dimming at 120-277V on 0-10V
controls
Factory Installed Emergency & Connected Lighting Options
REM7 = 7 watt emergency battery pack with remote test / indicator light, use
with D010 only (2) (6) REM14 = 14 watt emergency battery pack with remote test
/ indicator light, use with D010 only (2) (6) IEM7 = 7 watt emergency battery
pack with integral test / indicator light, use with D010 only (2) (6) IEM14 =
14 watt emergency battery pack with integral test / indicator light, use with
D010 only (2) (6)
Notes
Notes
(2) Not available with D010347 (347V models) (6) Emergency battery backup
options are Non-IC only, and rated for a minimum starting temperature of 0°C
Accessories (Order & Install Separately) HB128APK = L channel hanger bar, 26″,
pair (replacement) RMB22 = Adjustable wood joist mounting bars, pair, extend
to 22″ long
Notes
PS517016EN page 2
March 8, 2024 6:07 PM
LED Module Order Information
HC6 | HM6 | 61 | 61PS
LED Module
HM6 = 6″ LED Modules For use with HC6 – HC6CP New Construction housings only
Lumens
0525 = 500 – 2500 lumen 3040 = 3000-4000 lumen 4560 = 4500-6000 lumen
Notes
Notes
827 = 80CRI, 2700K 830 = 80CRI, 3000K 835 = 80CRI, 3500K 840 = 80CRI, 4000K 850 = 80CRI, 5000K
CRI/CCT
927 = 90CRI, 2700K 930 = 90CRI, 3000K 935 = 90CRI, 3500K 940 = 90CRI, 4000K
950 = 90CRI, 5000K
Notes
Trim Order Information
Reflector 61 = 6″ conical reflector
Notes
Distribution(8) ND = narrow 55° beam angle 0.97 SC MD = medium 60° beam angle 1.10 SC WD = wide 65° beam angle 1.28 SC RWW = rotatable wall wash with linear spread lens
Finish C = Specular clear H = Semi-specular clear W = White
Notes
(8) Values are nominal, with specular clear reflector, other finishes and
field results may vary.
Notes
Flange
Accessories
Blank = Polished flange standard with C & H reflectors 61RWWPK = Replacement part kit – wall
Blank = White flange standard with W reflector
wash lens insert – for use with 61RWW*
WF = White flange option available with C & H reflectors only.
Notes
Notes
Baffle 61 = 6″ baffle reflector
Notes
Distribution(8)
Finish
WD = wide 65° beam angle 1.28 SC (nominal) RWW = rotatable wall wash with linear spread lens
BB = Black baffle WB = White baffle
Notes
(8) Values are nominal, with specular clear reflector, other finishes and
field results may vary.
Notes
Flange Blank = White flange standard with BB, & WB BF = Black flange option
available with BB
Notes
Accessories 61RWWPK = Replacement part kit – wall wash lens insert – for use
with 61RWW* only.
Notes
Reflector 61PS = 6″ non-conductive polymer `dead front’ conical reflector (9)
Distribution(8) MD = medium 60° beam angle 1.10 SC (nominal)
Finish W = White
Notes
(9) 61PS is 1000-2000 lumens Non-IC rated. 500 & 750 lumens IC rated. 61PS is
not for use over 2000lm in Non-IC or over 750lm in IC.
Notes
(8) Values are nominal, with specular clear reflector, other finishes and
field results may vary.
Notes
Flange Blank = White flange standard with W reflector
Notes
IEM Reflector 61 = 6″ IEM reflector for integral emergency only
Distribution(8) ND = narrow 55° beam angle 0.97 SC MD = medium 60° beam angle 1.10 SC WD = wide 65° beam angle 1.28 SC
Finish C = Specular clear H = Semi-specular clear W = White
Notes
Notes
(8) Values are nominal, with specular clear reflector, other finishes and
field results may vary.
Notes
Flange
Integral Emergency
Blank = Polished flange standard with C & H reflectors Blank = White flange
standard with W reflector WF = White flange option available with C & H
reflectors
Notes
IEM = Reflector for use with integral emergency housings only. Provides access
hole for integral emergency test switch.
Notes
IEM Baffle 61 = 6″ IEM baffle reflector for integral emergency only
Distribution(8) WD = wide 65° beam angle 1.28 SC (nominal)
Finish BB = Black baffle WB = White baffle
Notes
Notes
(8) Values are nominal, with specular clear reflector, other finishes and
field results may vary.
Notes
Flange
Integral Emergency
Blank = White flange standard with BB, & WB BF = Black flange option with BB
Notes
IEM = Reflector for use with integral emergency housings only. Provides access
hole for integral emergency test switch.
Notes
PS517016EN page 3
March 8, 2024 6:07 PM
Product Specifications
Housing Frame · Boat shaped galvanized steel plaster frame with
adjustable plaster lip · Accommodates 1/2″ to 1-1/2″ thick ceilings · Installs
in new construction or from below the
finished ceiling (non-accessible) for remodeling (with mounting bars removed)
· Provided with two remodel clips to secure the frame to the ceiling
Universal Mounting Bracket · Adjusts 2″ vertically from above and below the
ceiling · Use with the included mounting bars or with 1/2”
Electric Metallic Tube (EMT) · Removable to facilitate remodeling installation
from below the finished ceiling
Mounting Bars · Captive pre-installed No FussTM mounting bars lock
to T-grid with screwdriver or pliers · Centering detents allow for consistent
positioning
of fixtures
LED Module · Proximity phosphors over chip on board LEDs
provide a uniform source with high efficiency and no pixilation · Available in
80 or 90 color rendering index (CRI) · Color accuracy within 3 SDCM provides
color consistency and uniformity · 90 CRI option: R9>50 (refer to chromaticity
information for details) · Available in 2700K, 3000K, 3500K, 4000K and 5000K
correlated color temperature (CCT) · Lumen options include 500, 750, 1000,
1500, 2000, 2500, 3000, 3500, 4000, 4500, 5000, 5500, 6000 lumens (nominal) ·
Passive thermal management achieves 60,000 hours at 70% lumen maintenance
(L70) in insulated ceilings (IC) and non-IC applications · Integral diffuse
lens provides visual shielding · Integral connector allows quick connection to
housing flex
Reflector · Self-flanged aluminum reflectors available in
narrow, medium or wide distribution patterns · Medium distribution polymer
non-conductive matte
white reflector may be used to meet local codes for `dead front’ applications
(500 & 750 lumen max. in IC and 2000 lumen max. in Non-IC) · Wall wash
reflector features a rotatable linear spread lens for alignment of vertical
illumination · Reflectors attach to LED module with three speed clamps ·
Available in multiple painted or plated finishes
Reflector/Module Retention · Reflector/module assembly is securely retained in
the housing with two torsion springs
Driver · Field-replaceable constant current driver provides
low noise operation
· Universal 120-277VAC 50/60Hz input standard · Continuous, 1% to 100% dimming
with 0-10V
analog control
· Optional low-voltage DC driver for use with Distributed Low Voltage Power
(DLVP) system
· Distributed Low Voltage Power (DLVP) system combines power, lighting and
controls with ease of installation (refer to DLVP Design Guide at
www.cooperlighting.com for details)
Canada Options · 347VAC 50/60Hz; 1% dimming on 0 -10V analog
control, for 500, 750, 1000, 1500, 2000, 2500, 3000, 3500, 4000, 4500, 5000
lumen models only · 347V step down transformer factory installed with the
standard “D010″ 120V-277V, LED driver on 5500, 6000 lumen models only
Emergency Option · Provides 90 minutes of standby lighting, meeting
most life safety codes for egress lighting · Available with integral or remote
charge indicator
and test switch · Available Self-Test (self-diagnostic) with remote
charge indicator and test switch · Quick Spec emergency ordering option for
quick-turn projects
Connected Lighting System Two WaveLinx connected solutions to choose from.
Refer to WaveLinx system specifications and application guides for details.
WaveLinx PRO Tilemount Sensor Kit · WaveLinx WTA tilemount sensor kit offers
daylight
dimming, PIR motion sensing, scene and zone configuration, automatic
commissioning; and optional RLTS – Real Time Location Services available.
WaveLinx PRO Wireless Node · WaveLinx PRO wireless node provides luminaire-
level control with scene and zone configuration without an integrated sensor;
Connects wirelessly with daylight dimming sensor and PIR motion sensor if
desired. Use with 0-10V driver only.
WaveLinx LITE Tilemount Sensor Kit · WaveLinx LITE WTK tilemount sensor kit
offers
daylight dimming and PIR motion sensing, scene and grouping configuration.
WaveLinx LITE Wireless Node · WaveLinx Lite wireless node provides luminaire
level control with scene and zone configuration without an integrated sensor;
Connects wirelessly with daylight dimming sensor and PIR motion sensor if
desired. Use with 0-10V driver only.
WaveLinx Tilemount Kits Application · The WTA and WTK tilemount kits include a
control
module mounted on the luminaire junction box via 1/2″ knock-out, and a
tilemount sensor on 54-inch whip; for ceiling installation by direct-mount
spring clips or via mounting bracket in octagon ceiling boxes. · The WTA and
WTK tilemount kits may be ordered as factory installed on the luminaire, or
ordered separately as a field installed accessory kit.
HC6 | HM6 | 61 | 61PS
Junction Box · Galvanized steel junction box · 20 in3 internal volume
excluding voltage barrier · 25 in3 internal total volume · Voltage barrier for
0-10V dimming wires (occupies
one 1/2″ pry-out space) · Listed for eight #12 AWG (four in, four out) 90°C
conductors and feed-thru branch wiring · Three 1/2″ and two 3/4″ trade size
pry-outs
available · Three 4-port push wire nuts for mains voltage with
1-port for fixture connection
Compliance · cULus Certified to UL 1598 / C22.2 No. 250.0,
suitable for damp locations and wet locations in covered ceilings only ·
Emergency options provided with UL Listed emergency drivers to UL 924 / C22.2
No. 141, suitable for indoor/damp locations · IP20 – Above finished ceiling;
IP65 – Below finished ceiling · Non-Insulated ceiling (Non-IC) rated for 2500,
3000, 3500, 4000, 4500, 5000, 5500, 6000 lumen models (insulation must be kept
3″ from top and sides) · Insulated ceiling (IC) rated for 500, 750, 1000,
1500, 2000 lumen models and suitable for direct contact with air permeable
insulation (IC models are also suitable for Non-IC installations) · Non-IC
marked spacing required for 4500, 5000, 5500, 6000 lumen models – Marked
Spacing Center to Center of Adjacent
Luminaires = 36″ – Center of Luminaire to Building Member = 18″ – Minimum
overhead = 0.5″
· Airtight per ASTM-E283-04 · Suitable for use in clothes closets when
installed
in accordance with the NEC 410.16 spacing requirements · EMI/RFI emissions FCC
CFR Title 47 Part 15 Class A at 120/277V · Contains no mercury or lead and
RoHS compliant · Photometric testing completed in accordance of IES LM-79-08 ·
Lumen maintenance projection in accordance of IES LM-80-08 and TM-21-11 · 500,
750, 1,000, 1,500 and 2,000 lumen, 90 CRI, ICAT models may be used to comply
with State of California Title 24 residential code, per JA8 certification
standards · May be used to comply with State of California Title 24 non-
residential code as a dimmable LED luminaire · ENERGY STAR® certified,
reference certified light fixtures database Not for use in direct contact
with spray foam insulation, consult NEMA LSD57-2013
Warranty · Five year limited warranty, consult website for
details. www.cooperlighting.com/legal
PS517016EN page 4
March 8, 2024 6:07 PM
Photometric Data
HC6 | HM6 | 61 | 61PS
View IES files
NARROW DISTRIBUTION – SPECULAR CLEAR FINISH, 2000 LUMEN MODEL, 80 CRI, 3500K
NARROW (55° BEAM*)
Test Number
P581878
Housing Module
HC620D010 HM60525835
Reflector 61NDC
Lumens Efficacy SC UGR
2228 Lm 111.4 Lm/W 0.93 11.7
CANDLEPOWER DISTRIBUTION Downlight
2434 1826 1217
609 0
0-deg
180° 170°160° 150° 140° 130° 120° 110°
100°
90°
80°
70° 60° 50° 40° 30° 0° 10° 20°
45-deg 90-deg
CONE OF LIGHT
0º
D
MH FC
L
W
5.5′ 80.2 5
5
7′ 49.5 6.4 6.4
8′ 37.9 7.4 7.4
9′
30 8.2 8.2
10′ 24.3 9.2 9.2
12′ 16.9 11 11
CANDELA TABLE
Degrees Vertical
0 5 15 25 35 45 55
Candela
2427 2422 2405 1621 761 118
12
65
3
75
2
85
0
90
0
ZONAL LUMEN SUMMARY
Zone Lumens % Fixture
0-30
1636
73.4
0-40
2098
94.2
0-60
2223
99.8
0-90
2228
100
9 0 -18 0
0
0
0 -18 0
2228
100
LUMINANCE
Average Candela Degrees
Average 0° Luminance
45
9187
55
1118
65
376
75
318
85
0
MEDIUM DISTRIBUTION – SPECULAR CLEAR FINISH, 2000 LUMEN MODEL, 80 CRI, 3500K
MEDIUM (60° BEAM*)
Test Number
P581875
Housing HC620D010
Module HM60525835
Reflector 61MDC
Lumens Efficacy SC UGR
2307 Lm 115.3 Lm/W 1.06 11.8
CANDLEPOWER DISTRIBUTION Downlight
2376 1782 1188
594 0
0-deg
180° 170°160° 150° 140° 130° 120° 110°
100°
90°
80°
70° 60° 50° 40° 30° 0° 10° 20°
45-deg 90-deg
CONE OF LIGHT
0º
D
MH FC
L
W
5.5′ 68.7 5.6 5.6
7′ 42.4 7.2 7.2
8′ 32.5 8.2 8.2
9′ 25.7 9.4 9.4
10′ 20.8 10.4 10.4
12′ 14.4 12.4 12.4
CANDELA TABLE
Degrees Vertical
0
5
Candela
1998 2022
15
2307
25
1842
35
796
45
126
55
15
65
4
75
2
85
0
90
0
ZONAL LUMEN SUMMARY
Zone Lumens % Fixture
0-30
1671
72.4
0-40
2163
93.8
0-60
2301
99.7
0-90
2307
100
9 0 -18 0
0
0
0 -18 0
2307
100
LUMINANCE
Average Candela Degrees
Average 0° Luminance
45
9753
55
1395
65
571
75
318
85
0
Note: Refer to IES files for more product data.
PS517016EN page 5
March 8, 2024 6:07 PM
Photometric Data
HC6 | HM6 | 61 | 61PS
View IES files
WIDE DISTRIBUTION – SPECULAR CLEAR FINISH, 2000 LUMEN MODEL, 80 CRI, 3500K
WIDE (65° BEAM*)
Test Number
P581885
Housing HC620D010
Module HM60525835
Reflector 61WDC
Lumens Efficacy SC UGR
2359 Lm 118 Lm/W 1.28 11.6
CANDLEPOWER DISTRIBUTION Downlight
1876 1407
938 469
0
0-deg
180° 170°160° 150° 140° 130° 120° 110°
100°
90°
80°
70° 60° 50° 40° 30° 0° 10° 20°
45-deg 90-deg
CONE OF LIGHT
0º
D
MH FC
L
W
5.5′ 50.5 7
7
7′ 31.2 8.8 8.8
8′ 23.9 10.2 10.2
9′ 18.8 11.4 11.4
10′ 15.3 12.8 12.8
12′ 10.6 15.4 15.4
CANDELA TABLE
Degrees Vertical
0 5 15 25 35 45 55 65 75 85 90
Candela
1526 1540 1685 1861 1027 252
32 6 2 0 0
*Value are nominal with specular clear reflectors, other finishes and field results may vary. SC = Spacing Criteria
UGR = Unified Glare Rating
ZONAL LUMEN SUMMARY
Zone Lumens % Fixture
0-30
1461
61.9
0-40
2105
89.2
0-60
2351
99.6
0-90
2359
100
9 0 -18 0
0
0
0 -18 0
2359
100
LUMINANCE
Average Candela Degrees
Average 0° Luminance
45
19506
55
3078
65
765
75
318
85
0
Photometric Multipliers (Nominal Lumen Values)
500 Lumen
750 Lumen
1000 Lumen
1500 Lumen
0.33
0.44
0.54
0.74
2000 Lumen 1.00
2500 Lumen 1.12
3000 Lumen 1.46
3500 Lumen 1.76
4000 Lumen
4500 Lumen
5000 Lumen
5500 Lumen
1.81
2.17
2.28
2.38
Multipliers for relative lumen values with other series models.
6000 Lumen 2.65
Color Finish Multipliers
Finish code
C
H
W/WB
BB
Finish
Specular Clear
Semi-Specular
Matte White White Baffle
Black Baffle
Multiplier
1.00
0.92
0.91
0.82
Multipliers for relative lumen values with other color finishes.
CCT Multipliers 80CRI
2700K
3000K
3500K
4000K
0.92
0.98
1.00
1.03
Multipliers for relative lumen values with other series color temperatures.
5000K 1.03
CCT Multipliers 90CRI
2700K
3000K
3500K
4000K
0.77
0.84
0.89
0.90
Multipliers for relative lumen values with other series color temperatures.
5000K 0.90
Note: Refer to IES files for more product data.
PS517016EN page 6
March 8, 2024 6:07 PM
Photometric Data
HC6 | HM6 | 61 | 61PS
View IES files
WALL WASH DISTRIBUTION – SPECULAR CLEAR FINISH, 2000 LUMEN MODEL, 80 CRI, 3500K
WALL WASH
Test Number
P581882
Housing HC620D010
Module HM60525835
Reflector 61RWWC
Lumens Efficacy SC
2179 Lm 109 Lm/W 1.15
CANDLEPOWER DISTRIBUTION Downlight
1112 834 556 278 0
0-deg
180° 170°160° 150° 140° 130° 120° 110°
100°
90°
80°
70° 60° 50° 40° 30° 0° 10° 20°
45-deg 90-deg
CANDELA TABLE
Degrees Vertical
0 5 15 25 35 45 55 65 75
Candela
1080 1081 1112 1034 800 514 319 184
85
85
12
90
0
ZONAL LUMEN SUMMARY
Zone Lumens % Fixture
0-30
849
39
0-40
1313
60.2
0-60
1978
90.8
0-90
2179
100
9 0 -18 0
0
0
0 -18 0
2179
100
LUMINANCE
Average Candela Degrees
Average 0° Luminance
45
39810
55
30479
65
23907
75
17983
85
7359
SC = Spacing Criteria, nominal for specular clear reflector, other finishes and field results may vary.
SINGLE UNIT FOOTCANDLES
2.5′ from wall (distance from fixture along wall)
1 19.3 13.8 6.1 2.2 0.7 0.3 0.1 2 29.1 22.6 12.3 5.7 2.5 1.2 0.6
3 27.6 22.5 13.8 7.3 3.7 1.9
1
4 21 18.2 12.4 7.4 4.2 2.4 1.4
5 14.4 13.1 9.9 6.6 4.1 2.5 1.6
6 9.7 9.1 7.5 5.5 3.7 2.5 1.6
7 6.7 6.4 5.5 4.3 3.2 2.2 1.5
8 4.7 4.6 4.1 3.4 2.7
2
1.4
9 3.4 3.3 3.1 2.7 2.2 1.7 1.3
10 2.5 2.5 2.4 2.1 1.8 1.4 1.1
MULTIPLE UNIT FOOTCANDLES
2.5′ from wall (Distance from fixture along
w3all)
1
21.5
19.1
21.5
2
34.7
34.4
34.7
3
34.9
36
34.9
4
28.4
30.7
28.4
5
21
23.2
21
6
15.2
16.8
15.2
7
11
12
11
2.5′ from wall (Distance from fixture along
w4all)
20
12.1
20
31.6
24.6
31.6
31.3
27.6
31.3
25.2
24.8
25.2
18.6
19.8
18.6
13.4
15
13.4
9.9
11
9.9
8
8.1
8.7
8.1
9
6.1
6.5
6.1
7.4
8.2
7.4
5.6
6.2
5.6
10 4.6
4.9
4.6
4.3
4.7
4.3
Photometric Multipliers (Nominal Lumen Values)
500 Lumen
750 Lumen
1000 Lumen
1500 Lumen
0.33
0.44
0.54
0.74
2000 Lumen 1.00
2500 Lumen 1.12
3000 Lumen 1.46
3500 Lumen 1.76
4000 Lumen
4500 Lumen
5000 Lumen
5500 Lumen
1.81
2.17
2.28
2.38
Multipliers for relative lumen values with other series models.
6000 Lumen 2.65
Color Finish Multipliers
Finish code
C
H
W/WB
BB
Finish
Specular Clear
Semi-Specular
Multiplier
1.00
0.92
Multipliers for relative lumen values with other color finishes.
Matte White White Baffle
0.91
Black Baffle 0.82
CCT Multipliers 80CRI
2700K
3000K
3500K
4000K
0.92
0.98
1.00
1.03
Multipliers for relative lumen values with other series color temperatures.
5000K 1.03
CCT Multipliers 90CRI
2700K
3000K
3500K
4000K
0.77
0.84
0.89
0.90
Multipliers for relative lumen values with other series color temperatures.
5000K 0.90
Note: Refer to IES files for more product data.
PS517016EN page 7
March 8, 2024 6:07 PM
Energy & Performance Data
COLOR METRICS – TM-30-15 & CRI/CIE (3500K) 80 CRI Color Metric Summary – 3500K*
TM-30-15
Rf = 86 Rg = 95.5
CRI/CIE
Ra = 83.8 R9 = 10.3
2700K 3000K 3500K 4000K 5000K
HC6 | HM6 | 61 | 61PS
90 CRI Color Metric Summary – 3500K*
TM-30-15
Rf = 91.1 Rg = 99
CRI/CIE
Ra = 92.4 R9 = 55.1
2700K 3000K 3500K 4000K 5000K
Reference Illuminant
Test Source
55° 60°
narrow medium Nominal Beam
65°
wide
ENERGY DATA
Series Input Voltage 120-277VAC Input Current (A) Input Power (W) In-rush (A)
Inrush duration (µs) THD (%) PF
500 lumen
120V
277V
0.051
0.026
6.1
6.5
1.9
8.4
251
135
6.2
13.5
0.99
0.9
750 lumen
120V
277V
0.067
0.036
7.9
8.3
2
8.4
237
133
7.4
8.8
0.98
0.92
Reference Illuminant
Test Source
55° 60°
narrow medium Nominal Beam
65°
wide
- Color values are based on 61WDWB reflector, other finishes and field results may vary.
1000 lumen
120V
277V
0.083
0.039
10
10.4
2.2
8.5
250
134
5.4
10.3
0.99
0.95
1500 lumen
120V
277V
0.119
0.053
14.5
14.5
2.7
8.5
250
139
10
6.7
0.99
0.97
2000 lumen
120V
277V
0.171
0.077
20.9
20.6
2.1
9.7
245
131
6.5
7.9
0.99
0.96
Series Input Voltage 120-277VAC Input Current (A) Input Power (W) In-rush (A) Inrush duration (µs) THD (%) PF
2500 lumen
120V
277V
0.23
0.103
27.5
27.5
2.5
5.6
232
123
6.5
8.1
0.99
0.96
3000 lumen
120V
277V
0.24
0.107
28.6
28.5
2.5
11.6
216
111
7.8
8.3
0.99
0.96
3500 lumen
120V
277V
0.292
0.152
34.6
35.1
3.4
13.9
183
95
5.6
10
0.99
0.93
4000 lumen
120V
277V
0.351
0.159
42.1
42.1
3.1
14.7
200
98
4.1
9.5
0.99
0.94
4500 lumen
120V
277V
0.384
0.172
45.9
45.6
3.1
14.8
202
100
4.5
8.5
0.99
0.95
Series Input Voltage 120-277VAC Input Current (A) Input Power (W) In-rush (A) Inrush duration (µs) THD (%) PF
5000 lumen
120V
277V
0.419
0.186
50.1
49.5
3.1
15
202
117
5.5
7.6
0.99
0.96
5500 lumen
120V
277V
0.457
0.201
54.6
53.7
3.2
14.8
196
131
7
7.2
0.99
0.96
Minimum starting temperature -30°C (-22°F)* (Nominal input 120-277VAC & 100%
of rated output power)
Sound Rating: Class A standards
Notes: * Emergency Battery packs are rated for a minimum starting temperature of 0°C.
6000 lumen
120V
277V
0.489
0.214
58.4
57.4
3.4
14.8
192
121
8.1
7.2
0.99
0.97
PS517016EN page 8
March 8, 2024 6:07 PM
Dimensional and Mounting Details
NEW CONSTRUCTIONS – LOW LUMEN 500 2500 LUMENS
NEW CONSTRUCTION – LOW LUMEN 500 2500 LUMENS
max module height
(see table)
4.2″ [107.34mm] hanger bar bracket
LED height (see table)
3.42″ [86.77mm]
height (removable)
(driver height)
.5″ [12.70mm] (ceiling thickness)
6.06″ [153.92mm] (reflector inner aperture)
7.25″ [184.15mm] (ceiling cut out)
7.75″ [196.85mm] (trim flange)
NEW CONSTRUCTIONS – MID LUMEN 3000 4000 LUMENS
NEW CONSTRUCTION – MID LUMEN 3000 AND 4000 LUMEN
max module height (see table)
LED height (see table) 3.42″
[86.77mm] (driver height)
.5″ [12.70mm] (ceiling thickness)
6.06″ [153.92mm] (reflector inner aperture)
7.25″ [184.15mm] (ceiling cut out)
7.75″ [196.85mm] (trim flange)
NEW CONSTRUCTIONS – HIGH LUMEN 4500 6000 LUMENS
NEW CONSTRUCTION – HIGH LUMEN 4500 6000 LUMEN
max module height (see table)
LED height (see table) 3.42″
[86.77mm] (driver height)
.5″ [12.70mm] (ceiling thickness)
6.05″ [153.72mm] (reflector inner aperture)
7.25″ [184.15mm] (ceiling cut out)
7.75″ [196.85mm] (trim flange)
HC6 | HM6 | 61 | 61PS
Low Lumen (500 2500 Lumens)*
trim height (see table)
Distribution Narrow Medium Wide
Max. Module Height
Trim Height
4.5″
3.4″
4.6″
3.5″
4.4″
3.3″
LED Height 3.8″ 3.9″ 3.7″
Baffle
4.4″
3.3″
3.7″
*Max. height w/removable hanger bar bracket 4.2″
Low Lumen Module
trim height (see table)
Mid Lumen (3000 4000 Lumens)
Distribution Narrow Medium Wide
Max. Module Height
Trim Height
6.6″
3.4″
6.7″
3.5″
6.5″
3.3″
Baffle
6.5″
3.3″
LED Height
3.8″ 3.9″ 3.7″ 3.7″
Mid Lumen Module
trim height (see table)
High Lumen (4500 6000 Lumens)
Distribution Narrow Medium Wide Baffle
Max. Module Height
Trim Height
6.9″
3.4″
7.0″
3.5″
6.8″
3.3″
6.8″
3.3″
LED Height 3.8″ 3.9″ 3.7″ 3.7″
High Lumen Module
PS517016EN page 9
March 8, 2024 6:07 PM
Connected Solutions WaveLinx LITE – WTK Tilemount Sensor
HC6 | HM6 | 61 | 61PS
· Intuitive AndroidTM or Apple® iOS® app for basic system code compliant set up and configuration via Bluetooth · Up to 28 unique areas per project site (WaveLinx LITE Bluetooth network) · Up to 50 devices for an area, any one of 16 control zones, up to 6 occupancy sets, and custom lighting scenes · Automatic occupancy or vacancy, sensor sensitivity, daylight dimming, etc. configurable through the app · Refer to the WaveLinx system specifications for details
Device Security
Manual Dimmer
Occupancy Sensor
Daylighting Control
Manually Switched ON/OFF
Tuning Control
Lumen Maintenance Control
Scenes
WaveLinx LITE WTK Tilemount Wiring Diagram
WaveLinx LITE Bluetooth Enabled System
120-277 VAC
Black (Hot) White (Neutral)
Control module (MSP3IVMVDC1EP)
Pink (Dimming) Purple (Dimming) Blue (Not Switched) White (Neutral)
Includes switchleg (Blue load out wire) and 0-10V to each fixture controlled
0-10V DImming Driver
120-277 VAC 3A downlights with 0-10V control
WaveLinx LITE Tilemount Sensor Kit control module
(MSP3IVMVDC1EP) (included)
54″ Plenum cable (5140-000123-00)
(included)
ceiling tile
ceiling tile ceiling cutaway view
WaveLinx LITE Sensor and Mounting Trim (included)
MyApps
Secure Portal
Site Initiation, Data Backup & Site Transfer
WaveLinx LITE Mobile Application
WaveLinx LITE Ambient
WaveLinx LITE Integrated Ambient
WaveLinx LITE Tilemount Sensor Kit
WaveLinx LITE Wallstation
WaveLinx LITE Integrated Industrial
WaveLinx LITE Integrated
Parking Garage
WaveLinx PRO WTA Tilemount Sensor
· WaveLinx PRO tilemount functionality configures zones and customizes settings from one secure mobile app · Automatic code commissioning that meets the strictest codes · Fixtures and sensors integrate with Wireless Area Controller, Wall Stations, and Control Devices · Stand-Alone Offices or Entire Building Network Installations
- Downlights with tilemount sensor wireless communication
Highly efficient LED fixtures
++
WaveLinx Area Controller
Provides centralized coordination of multiple
area control options
Wireless Wall Station/Receptacle
Provides customized wireless control of each area
Mobile Applications
Provides personalized, local control from a tablet or smartphone
WaveLinx mobile app settings
Manual Dimmer
Occupancy Sensor
Lumen Maintenance Control
Daylighting Control
Receptacle Control
Tuning Control
Scheduling
Manually Switched ON/OFF
Demand Response
WaveLinx WTA Tilemount Wiring Diagram
120-277 VAC
Black (Hot) White (Neutral)
Control module (MSP3IVMVDC1EP)
Pink (Dimming) Purple (Dimming) Blue (Not Switched) White (Neutral)
Includes switchleg (Blue load out wire) and 0-10V to each fixture controlled
0-10V DImming Driver
120-277 VAC 3A downlights with 0-10V control
WaveLinx Tilemount Sensor Kit control module
(MSP3IVMVDC1EP) (included)
54” Plenum cable (5140-000123-00)
(included)
ceiling tile
ceiling tile
WaveLinx Sensor and Mounting Trim (included)
WaveLinx CORE Building Management Integration
BACnet/IP Public (REST) API
Desktop/Laptop
with web browser (hardware provided
by user)
WaveLinx CORE
Third Party system (hardware provided by others) Building LAN
Touchscreen
BACnet Router1 (hardware provided by others)
PoE Power
WaveLinx Area
Controller
Smartphone with WaveLinx app
used for system
setup and
personal control
Area or Room
(49 + 1 construction area)
Area or Room
(49 + 1 construction area)
Area or Room
(49 + 1 construction area)
120-347V 20A PRO Dimming Switchpacks
PRO Occupancy Ceiling Sensor
WaveLinx PRO controlled devices
(up to 200 devices per WAC2 – 150 devices best practice) – see Note
PRO Controlled Receptacle
PRO Wallstation
WaveLinx PRO enabled Indoor Fixture
WaveLinx PRO enabled Outdoor Fixture
KEY
Wi-Fi Signal
IEEE 802.15.4
Note: Performance based on second generation WaveLinx Area Controller (WAC2).
WaveLinx CORE Pro shown in this illustration. WaveLinx CORE hardware can be
either Pro, Enterprise or Virtual. 1 BACnet Router only required if WaveLinx
CORE and third party BACnet client are on different subnets.
PS517016EN page 10
March 8, 2024 6:07 PM
HC6 | HM6 | 61 | 61PS
Connected Solutions
WaveLinx LITE Wireless Node – WLN
· Intuitive AndroidTM or Apple® iOS® app for basic system code compliant set
up and configuration via Bluetooth
· Up to 28 unique areas per project site (WaveLinx LITE Bluetooth network)
· Up to 50 devices for an area, any one of 16 control zones, up to 6 occupancy
sets, and custom lighting scenes
· Refer to the WaveLinx system specifications for details
WaveLinx mobile app settings
- Downlights with wireless communication
Highly efficient LED fixtures
++
WaveLinx Area Controller
Provides centralized coordination of multiple
area control options
Wireless Wall Station/Receptacle
Provides customized wireless control of each area
Mobile Applications
Provides personalized, local control from a tablet or smartphone
Device Security
Manual Dimmer
Occupancy Sensor
Daylighting Control
Manually Switched ON/OFF
Tuning Control
Lumen Maintenance Control
Scenes
WaveLinx LITE Wireless Node (WLN) Wiring Diagram
WaveLinx LITE Bluetooth Enabled System
WPN Grey (GND)
MyApps
Secure Portal
Site Initiation, Data Backup & Site Transfer
Yellow (Aux-) Grey (Aux-) Pink (Dim-) Purple (Dim+)
Gree n (GND) White (AC -N) Black (AC-L)
D010
Red (LED+) Blue (LED-)
WaveLinx LITE Mobile Application
WaveLinx PRO Wireless Node – WPN
WaveLinx LITE Ambient
WaveLinx LITE Integrated Ambient
WaveLinx LITE Tilemount Sensor Kit
WaveLinx LITE Wallstation
WaveLinx LITE Integrated Industrial
WaveLinx LITE Integrated
Parking Garage
· WaveLinx Wireless functionality configures zones and customizes settings
from one secure mobile app
· Automatic code commissioning that meets the strictest codes
· Fixtures and sensors integrate with WaveLinx Area Controller, Wall Stations,
and Control Devices
· Stand-Alone Offices or Entire Building Network Installations
- Downlights with wireless communication
Highly efficient LED fixtures
++
WaveLinx Area Controller
Provides centralized coordination of multiple
area control options
Wireless Wall Station/Receptacle
Provides customized wireless control of each area
Mobile Applications
Provides personalized, local control from a tablet or smartphone
WaveLinx mobile app settings
Manual Dimmer
Occupancy Sensor
Lumen Maintenance Control
Daylighting Control
Receptacle Control
Tuning Control
Scheduling
Manually Switched ON/OFF
Demand Response
WaveLinx PRO Wireless Node (WPN) Wiring Diagram
WaveLinx CORE Building Management Integration
WPN Grey (GND)
BACnet/IP Public (REST) API
Desktop/Laptop
with web browser
(hardware provided
by user)
Trellix Core
Yellow (Aux-) Grey (Aux-) Pink (Dim-) Purple (Dim+)
Gree n (GND) White (AC -N) Black (AC-L)
D010
Red (LED+) Blue (LED-)
Third Party system
(hardware provided by others)
Building LAN
Touchscreen
BACnet Router1
(hardware provided by others)
PoE Power
WaveLinx Mobile App used for system setup and personal control
Wireless Area Controller
Cooper Lighting Solutions 1121 Highway 74 South Peachtree City, GA 30269 P: 770-486-4800 www.cooperlighting.com
© 2024 Cooper Lighting Solutions All Rights Reserved.
Specifications and dimensions subject to change without notice.
PS517016EN page 11
March 8, 2024 6:07 PM
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>