HALO HC6 6 Inch LED Downlight And Wall Wash Owner’s Manual

June 1, 2024
HALO

HC6 6 Inch LED Downlight And Wall Wash

“`html

Product Specifications

  • Product Name: 6-inch LED Downlight and Wall Wash

  • Models: HC6, HM6, 61, 61PS

  • Lumen Options: 500 lm to 6000 lm

  • Driver Options: D010, D010347, D010X347, DLV

  • Emergency Battery Pack Options: REM7, REM14, IEM7, IEM14,
    BOD7ST, REMV7, REMV14, IEMV7, IEMV14

  • Control Compatibility: WaveLinx LITE, WaveLinx PRO

Product Usage Instructions

Mounting Frame Installation

  1. Identify the appropriate mounting frame based on your
    requirements.

  2. Ensure the lumens and driver options match your setup.

  3. Follow the provided instructions for installing the mounting
    frame securely.

LED Module Installation

  1. Select the LED height based on your ceiling thickness and
    desired light output.

  2. Carefully insert the LED module into the designated slot in the
    mounting frame.

  3. Ensure a secure fit to prevent any movement during
    operation.

Control Compatibility Setup

  1. If using WaveLinx LITE or PRO, refer to the respective control
    system manual for setup instructions.

  2. Connect the downlight to the control system following the
    recommended wiring diagram.

  3. Test the control system to ensure proper functionality with the
    LED downlight.

Emergency Battery Pack Installation

  1. If adding an emergency battery pack, select the appropriate
    wattage and type based on your needs.

  2. Install the emergency battery pack according to the provided
    instructions and wiring diagram.

  3. Regularly test the emergency lighting functionality to ensure
    readiness in case of power outages.

Frequently Asked Questions (FAQ)

Q: Can I use a different driver option than the ones

listed?

A: It is recommended to use one of the specified driver options
for optimal performance and compatibility with the LED
downlight.

Q: How do I determine the appropriate lumen output for my

space?

A: Consider factors such as room size, ceiling height, and
desired brightness level when selecting the lumen option for your
LED downlight.

Q: Are the emergency battery packs compatible with all

models?

A: Some emergency battery pack options are not available for
certain models, so refer to the compatibility list before making a
selection.

“`

Project Prepared by

Catalog # Notes

Type Date

HC6 | HM6 | 61 | 61PS
6-inch LED downlight and wall wash

Typical Applications Office · Healthcare · Hospitality · Institutional · Mixed-Use/Retail

Interactive Menu
· Order Information page 2 · Product Specifications page 4 · Photometric Data page 5 · Energy & Performance Data page 8 · Connected Systems page 10 · Product Warranty

Product Certification

Top Product Features
· New construction/remodel series; 500 to 6,000 lumens · Narrow, Medium and Wide distributions; Wall wash with rotatable linear spread lens · 2700K, 3000K, 3500K, 4000K, 5000K CCT; 80 or 90 CRI · Universal voltage 120V-277V; Standard 0-10V driver dims to 1% · Mounting frame converts to remodel that installs from below the ceiling · Quick Spec emergency backup mounting frames – fast delivery option

Product Features

Control Compatibility

WaveLinx LITE

WaveLinx PRO

Dimensional and Mounting Details
26.4″ [670.56mm] 8.6″ [217.35mm]

NEW CONSTRUCTION – MID LUMEN 3000 AND 4000 LUMEN
max module height (see table)

LED height (see table) 3.42″
[86.77mm] (driver height)

.5″ [12.70mm] (ceiling thickness)
Mid Lumen (3000 ­ 4000 Lumens)

6.06″ [153.92mm] (reflector inner aperture)
7.25″ [184.15mm] (ceiling cut out)
7.75″ [196.85mm] (trim flange)

Distribution Narrow Medium Wide Baffle

Max. Module Height

Trim Height

6.6″

3.4″

6.7″

3.5″

6.5″

3.3″

LED Height
3.8″ 3.9″ 3.7″

6.5″

3.3″

3.7″

additional product diagrams
trim height (see table)

PS517016EN page 1
March 8, 2024 6:07 PM

Mounting Frame Order Information
Sample Number: HC620D010REM7 ­ HM60525835 – 61MDC A complete luminaire consists of a housing frame, LED module, and reflector (ordered separately)

HC6 | HM6 | 61 | 61PS

Mounting Frame

Lumens

Driver Options

Factory Installed Emergency & Connected Lighting Options

Accessories (Order & Install Separately)

HC6 = 6″ new construction downlight housing HC6CP = 6″ new construction housing, Chicago Plenum – CCEA compliant
Notes

05 = 500 lm 07 = 750 lm 10 = 1000 lm 15 = 1500 lm 20 = 2000 lm 25 = 2500 lm 30 = 3000 lm 35 = 3500 lm 40 = 4000 lm 45 = 4500 lm (7) 50 = 5000 lm (7) 55 = 5500 lm (7) 60 = 6000 lm (7)
Notes (7) Marked Spacing: Center to Center of Adjacent Luminaires = 36″ Center of Luminaire to Building Member = 18″ Minimum overhead = 0.5

D010=UNV 120-277V, 50/60Hz, 0-10V 1%-100% dimming at 120-277V on 0-10V controls
Canada Option 500-5000 lumens: D010347 = 347VAC 50/60Hz 0-10V 1%100% dimming. For 500, 750, 1000, 1500, 2000, 2500, 3000, 3500, 4000, 4500, 5000lm models only (1)
Canada Option 5500-6000 lumens: D010X347 = step down transformer factory installed (with standard “D010″ 120V-277V LED driver). For 5500, 6000lm models only (1)
DLV = Distributed Low Voltage dimming driver 1%-100%, 1000-4000 lumens only. For use with DLVP system only, refer to DLVP specifications for details. (1)
Notes (1) Not available with CP models

REM7 = 7 watt emergency battery pack with remote test / indicator light, use with D010 only (1) (2) (6)
REM14 = 14 watt emergency battery pack with remote test / indicator light, use with D010 only (1) (2) (6)
IEM7 = 7 watt emergency battery pack with integral test / indicator light, use with D010 only (1) (2) (6)
IEM14 = 14 watt emergency battery pack with integral test / indicator light, use with D010 only (1) (2) (6)
BOD7ST = 7.5 watt Bodine self-test emergency battery pack with remote test / indicator light, use with D010 only (1) (2) (6)
WTA = Factory WaveLinx Tilemount Sensor Kit (4)
WTK = Factory WaveLinx LITE Commercial Tilemount Sensor Kit (5) WPN = WaveLinx PRO Wireless Node without sensor (9) WLN = WaveLinx LITE Wireless Node without sensor (10)
REMV7 = 7 watt emergency battery pack with remote test / indicator light, use with DLV only (1) (2) (3) (6)
REMV14 = 14 watt emergency battery pack with remote test / indicator light, use with DLV only (1) (2) (3) (6)
IEMV7 = 7 watt emergency battery pack with integral test / indicator light, use with DLV only (1) (2) (3) (6)
IEMV14 = 14 watt emergency battery pack with integral test / indicator light, use with DLV only (1) (2) (3) (6)
Notes
(1) Not available with CP models (2) Not available with D010347 (347V models) (3) ULus for U.S. only (4) WTA = WaveLinx tilemount sensor kit for daylight dimming, PIR motion sensing, and optional RLTS – Real Time Location Services, use with D010 only (Refer to WaveLinx specifications) (5) WTK = WaveLinx LITE tilemount sensor kit for daylight dimming, PIR motion sensing, use with D010 only (Refer to WaveLinx LITE specifications) (6) Emergency battery backup options are Non-IC only, and rated for a minimum starting temperature of 0°C (9) WPN = WaveLinx PRO wireless node provides luminaire-level control with scene and zone configuration without an integrated sensor; Connects wirelessly with daylight dimming sensor and PIR motion sensor if desired. Use with 0-10V driver only. (10) WLN = WaveLinx LITE wireless node provides luminaire-level control with scene and zone configuration without an integrated sensor; Connects wirelessly with daylight dimming sensor and PIR motion sensor if desired. Use with 0-10V driver only.

HB128APK = L channel hanger bar, 26″, pair (replacement) RMB22 = Adjustable wood joist mounting bars, pair, extend to 22″ long HSA6 = Slope Adapter for 6″ Aperture Housings, Specify Slope (refer to instructions for installing housing and trim) H347 = 347 to 120V step down transformer, 75VA H347200 = 347 to 120V step down transformer, 200VA WTA = Field WaveLinx Tilemount Sensor Kit (4) WTK = Field WaveLinx LITE Commercial Tilemount Sensor Kit (5)
Notes (4) WTA = WaveLinx tilemount sensor kit for daylight dimming, PIR motion sensing, and optional RLTS – Real Time Location Services, use with D010 only (Refer to WaveLinx specifications) (5) WTK = WaveLinx LITE tilemount sensor kit for daylight dimming, PIR motion sensing, use with D010 only (Refer to WaveLinx LITE specifications)

Quick Spec Emergency Mounting Frame Order Information
Sample Number : Quick Spec Emergency Mounting Frame: RR-HC620D010REM7 LED module and reflectors are ordered separately. Order separately: LED Module: HM60525835 | Reflector: 61MDC

Select from the Quick Spec Mounting Frame ordering information to receive the
Fast Delivery option for the frame.

Quick Spec Code

Mounting Frame

Lumens

RR = East Region BRR = West Region

HC6 = 6″ new construction downlight housing

10 = 1000 lm 15 = 1500 lm 20 = 2000 lm 30 = 3000 lm 40 = 4000 lm

Notes

Notes

Notes

Driver Options
D010=UNV 120-277V, 50/60Hz, 0-10V 1%-100% dimming at 120-277V on 0-10V controls

Factory Installed Emergency & Connected Lighting Options
REM7 = 7 watt emergency battery pack with remote test / indicator light, use with D010 only (2) (6) REM14 = 14 watt emergency battery pack with remote test / indicator light, use with D010 only (2) (6) IEM7 = 7 watt emergency battery pack with integral test / indicator light, use with D010 only (2) (6) IEM14 = 14 watt emergency battery pack with integral test / indicator light, use with D010 only (2) (6)

Notes

Notes
(2) Not available with D010347 (347V models) (6) Emergency battery backup options are Non-IC only, and rated for a minimum starting temperature of 0°C

Accessories (Order & Install Separately) HB128APK = L channel hanger bar, 26″, pair (replacement) RMB22 = Adjustable wood joist mounting bars, pair, extend to 22″ long
Notes

PS517016EN page 2
March 8, 2024 6:07 PM

LED Module Order Information

HC6 | HM6 | 61 | 61PS

LED Module
HM6 = 6″ LED Modules For use with HC6 – HC6CP New Construction housings only

Lumens
0525 = 500 – 2500 lumen 3040 = 3000-4000 lumen 4560 = 4500-6000 lumen

Notes

Notes

827 = 80CRI, 2700K 830 = 80CRI, 3000K 835 = 80CRI, 3500K 840 = 80CRI, 4000K 850 = 80CRI, 5000K

CRI/CCT
927 = 90CRI, 2700K 930 = 90CRI, 3000K 935 = 90CRI, 3500K 940 = 90CRI, 4000K 950 = 90CRI, 5000K
Notes

Trim Order Information

Reflector 61 = 6″ conical reflector
Notes

Distribution(8) ND = narrow 55° beam angle 0.97 SC MD = medium 60° beam angle 1.10 SC WD = wide 65° beam angle 1.28 SC RWW = rotatable wall wash with linear spread lens

Finish C = Specular clear H = Semi-specular clear W = White

Notes
(8) Values are nominal, with specular clear reflector, other finishes and field results may vary.

Notes

Flange

Accessories

Blank = Polished flange standard with C & H reflectors 61RWWPK = Replacement part kit – wall

Blank = White flange standard with W reflector

wash lens insert – for use with 61RWW*

WF = White flange option available with C & H reflectors only.

Notes

Notes

Baffle 61 = 6″ baffle reflector
Notes

Distribution(8)

Finish

WD = wide 65° beam angle 1.28 SC (nominal) RWW = rotatable wall wash with linear spread lens

BB = Black baffle WB = White baffle

Notes
(8) Values are nominal, with specular clear reflector, other finishes and field results may vary.

Notes

Flange Blank = White flange standard with BB, & WB BF = Black flange option available with BB
Notes

Accessories 61RWWPK = Replacement part kit – wall wash lens insert – for use with 61RWW* only.
Notes

Reflector 61PS = 6″ non-conductive polymer `dead front’ conical reflector (9)

Distribution(8) MD = medium 60° beam angle 1.10 SC (nominal)

Finish W = White

Notes
(9) 61PS is 1000-2000 lumens Non-IC rated. 500 & 750 lumens IC rated. 61PS is not for use over 2000lm in Non-IC or over 750lm in IC.

Notes
(8) Values are nominal, with specular clear reflector, other finishes and field results may vary.

Notes

Flange Blank = White flange standard with W reflector
Notes

IEM Reflector 61 = 6″ IEM reflector for integral emergency only

Distribution(8) ND = narrow 55° beam angle 0.97 SC MD = medium 60° beam angle 1.10 SC WD = wide 65° beam angle 1.28 SC

Finish C = Specular clear H = Semi-specular clear W = White

Notes

Notes
(8) Values are nominal, with specular clear reflector, other finishes and field results may vary.

Notes

Flange

Integral Emergency

Blank = Polished flange standard with C & H reflectors Blank = White flange standard with W reflector WF = White flange option available with C & H reflectors
Notes

IEM = Reflector for use with integral emergency housings only. Provides access hole for integral emergency test switch.
Notes

IEM Baffle 61 = 6″ IEM baffle reflector for integral emergency only

Distribution(8) WD = wide 65° beam angle 1.28 SC (nominal)

Finish BB = Black baffle WB = White baffle

Notes

Notes
(8) Values are nominal, with specular clear reflector, other finishes and field results may vary.

Notes

Flange

Integral Emergency

Blank = White flange standard with BB, & WB BF = Black flange option with BB
Notes

IEM = Reflector for use with integral emergency housings only. Provides access hole for integral emergency test switch.
Notes

PS517016EN page 3
March 8, 2024 6:07 PM

Product Specifications
Housing Frame · Boat shaped galvanized steel plaster frame with
adjustable plaster lip · Accommodates 1/2″ to 1-1/2″ thick ceilings · Installs in new construction or from below the
finished ceiling (non-accessible) for remodeling (with mounting bars removed) · Provided with two remodel clips to secure the frame to the ceiling
Universal Mounting Bracket · Adjusts 2″ vertically from above and below the
ceiling · Use with the included mounting bars or with 1/2”
Electric Metallic Tube (EMT) · Removable to facilitate remodeling installation
from below the finished ceiling
Mounting Bars · Captive pre-installed No FussTM mounting bars lock
to T-grid with screwdriver or pliers · Centering detents allow for consistent positioning
of fixtures
LED Module · Proximity phosphors over chip on board LEDs
provide a uniform source with high efficiency and no pixilation · Available in 80 or 90 color rendering index (CRI) · Color accuracy within 3 SDCM provides color consistency and uniformity · 90 CRI option: R9>50 (refer to chromaticity information for details) · Available in 2700K, 3000K, 3500K, 4000K and 5000K correlated color temperature (CCT) · Lumen options include 500, 750, 1000, 1500, 2000, 2500, 3000, 3500, 4000, 4500, 5000, 5500, 6000 lumens (nominal) · Passive thermal management achieves 60,000 hours at 70% lumen maintenance (L70) in insulated ceilings (IC) and non-IC applications · Integral diffuse lens provides visual shielding · Integral connector allows quick connection to housing flex
Reflector · Self-flanged aluminum reflectors available in
narrow, medium or wide distribution patterns · Medium distribution polymer non-conductive matte
white reflector may be used to meet local codes for `dead front’ applications (500 & 750 lumen max. in IC and 2000 lumen max. in Non-IC) · Wall wash reflector features a rotatable linear spread lens for alignment of vertical illumination · Reflectors attach to LED module with three speed clamps · Available in multiple painted or plated finishes
Reflector/Module Retention · Reflector/module assembly is securely retained in
the housing with two torsion springs
Driver · Field-replaceable constant current driver provides
low noise operation
· Universal 120-277VAC 50/60Hz input standard · Continuous, 1% to 100% dimming with 0-10V
analog control
· Optional low-voltage DC driver for use with Distributed Low Voltage Power (DLVP) system
· Distributed Low Voltage Power (DLVP) system combines power, lighting and controls with ease of installation (refer to DLVP Design Guide at www.cooperlighting.com for details)

Canada Options · 347VAC 50/60Hz; 1% dimming on 0 -10V analog
control, for 500, 750, 1000, 1500, 2000, 2500, 3000, 3500, 4000, 4500, 5000 lumen models only · 347V step down transformer factory installed with the standard “D010″ 120V-277V, LED driver on 5500, 6000 lumen models only
Emergency Option · Provides 90 minutes of standby lighting, meeting
most life safety codes for egress lighting · Available with integral or remote charge indicator
and test switch · Available Self-Test (self-diagnostic) with remote
charge indicator and test switch · Quick Spec emergency ordering option for
quick-turn projects
Connected Lighting System Two WaveLinx connected solutions to choose from. Refer to WaveLinx system specifications and application guides for details.
WaveLinx PRO Tilemount Sensor Kit · WaveLinx WTA tilemount sensor kit offers daylight
dimming, PIR motion sensing, scene and zone configuration, automatic commissioning; and optional RLTS – Real Time Location Services available.
WaveLinx PRO Wireless Node · WaveLinx PRO wireless node provides luminaire-
level control with scene and zone configuration without an integrated sensor; Connects wirelessly with daylight dimming sensor and PIR motion sensor if desired. Use with 0-10V driver only.
WaveLinx LITE Tilemount Sensor Kit · WaveLinx LITE WTK tilemount sensor kit offers
daylight dimming and PIR motion sensing, scene and grouping configuration.
WaveLinx LITE Wireless Node · WaveLinx Lite wireless node provides luminaire
level control with scene and zone configuration without an integrated sensor; Connects wirelessly with daylight dimming sensor and PIR motion sensor if desired. Use with 0-10V driver only.
WaveLinx Tilemount Kits Application · The WTA and WTK tilemount kits include a control
module mounted on the luminaire junction box via 1/2″ knock-out, and a tilemount sensor on 54-inch whip; for ceiling installation by direct-mount spring clips or via mounting bracket in octagon ceiling boxes. · The WTA and WTK tilemount kits may be ordered as factory installed on the luminaire, or ordered separately as a field installed accessory kit.

HC6 | HM6 | 61 | 61PS
Junction Box · Galvanized steel junction box · 20 in3 internal volume excluding voltage barrier · 25 in3 internal total volume · Voltage barrier for 0-10V dimming wires (occupies
one 1/2″ pry-out space) · Listed for eight #12 AWG (four in, four out) 90°C
conductors and feed-thru branch wiring · Three 1/2″ and two 3/4″ trade size pry-outs
available · Three 4-port push wire nuts for mains voltage with
1-port for fixture connection
Compliance · cULus Certified to UL 1598 / C22.2 No. 250.0,
suitable for damp locations and wet locations in covered ceilings only · Emergency options provided with UL Listed emergency drivers to UL 924 / C22.2 No. 141, suitable for indoor/damp locations · IP20 – Above finished ceiling; IP65 – Below finished ceiling · Non-Insulated ceiling (Non-IC) rated for 2500, 3000, 3500, 4000, 4500, 5000, 5500, 6000 lumen models (insulation must be kept 3″ from top and sides) · Insulated ceiling (IC) rated for 500, 750, 1000, 1500, 2000 lumen models and suitable for direct contact with air permeable insulation (IC models are also suitable for Non-IC installations) · Non-IC marked spacing required for 4500, 5000, 5500, 6000 lumen models – Marked Spacing Center to Center of Adjacent
Luminaires = 36″ – Center of Luminaire to Building Member = 18″ – Minimum overhead = 0.5″
· Airtight per ASTM-E283-04 · Suitable for use in clothes closets when installed
in accordance with the NEC 410.16 spacing requirements · EMI/RFI emissions FCC CFR Title 47 Part 15 Class A at 120/277V · Contains no mercury or lead and RoHS compliant · Photometric testing completed in accordance of IES LM-79-08 · Lumen maintenance projection in accordance of IES LM-80-08 and TM-21-11 · 500, 750, 1,000, 1,500 and 2,000 lumen, 90 CRI, ICAT models may be used to comply with State of California Title 24 residential code, per JA8 certification standards · May be used to comply with State of California Title 24 non- residential code as a dimmable LED luminaire · ENERGY STAR® certified, reference certified light fixtures database
Not for use in direct contact with spray foam insulation, consult NEMA LSD57-2013
Warranty · Five year limited warranty, consult website for
details. www.cooperlighting.com/legal

PS517016EN page 4
March 8, 2024 6:07 PM

Photometric Data

HC6 | HM6 | 61 | 61PS
View IES files

NARROW DISTRIBUTION – SPECULAR CLEAR FINISH, 2000 LUMEN MODEL, 80 CRI, 3500K

NARROW (55° BEAM*)

Test Number

P581878

Housing Module

HC620D010 HM60525835

Reflector 61NDC

Lumens Efficacy SC UGR

2228 Lm 111.4 Lm/W 0.93 11.7

CANDLEPOWER DISTRIBUTION Downlight

2434 1826 1217
609 0

0-deg

180° 170°160° 150° 140° 130° 120° 110°
100°
90°
80°
70° 60° 50° 40° 30° 0° 10° 20°
45-deg 90-deg

CONE OF LIGHT

D

MH FC

L

W

5.5′ 80.2 5

5

7′ 49.5 6.4 6.4

8′ 37.9 7.4 7.4

9′

30 8.2 8.2

10′ 24.3 9.2 9.2

12′ 16.9 11 11

CANDELA TABLE

Degrees Vertical
0 5 15 25 35 45 55

Candela
2427 2422 2405 1621 761 118
12

65

3

75

2

85

0

90

0

ZONAL LUMEN SUMMARY

Zone Lumens % Fixture

0-30

1636

73.4

0-40

2098

94.2

0-60

2223

99.8

0-90

2228

100

9 0 -18 0

0

0

0 -18 0

2228

100

LUMINANCE

Average Candela Degrees

Average 0° Luminance

45

9187

55

1118

65

376

75

318

85

0

MEDIUM DISTRIBUTION – SPECULAR CLEAR FINISH, 2000 LUMEN MODEL, 80 CRI, 3500K

MEDIUM (60° BEAM*)

Test Number

P581875

Housing HC620D010

Module HM60525835

Reflector 61MDC

Lumens Efficacy SC UGR

2307 Lm 115.3 Lm/W 1.06 11.8

CANDLEPOWER DISTRIBUTION Downlight

2376 1782 1188
594 0

0-deg

180° 170°160° 150° 140° 130° 120° 110°
100°
90°
80°
70° 60° 50° 40° 30° 0° 10° 20°
45-deg 90-deg

CONE OF LIGHT

D

MH FC

L

W

5.5′ 68.7 5.6 5.6

7′ 42.4 7.2 7.2

8′ 32.5 8.2 8.2

9′ 25.7 9.4 9.4

10′ 20.8 10.4 10.4

12′ 14.4 12.4 12.4

CANDELA TABLE

Degrees Vertical
0
5

Candela
1998 2022

15

2307

25

1842

35

796

45

126

55

15

65

4

75

2

85

0

90

0

ZONAL LUMEN SUMMARY

Zone Lumens % Fixture

0-30

1671

72.4

0-40

2163

93.8

0-60

2301

99.7

0-90

2307

100

9 0 -18 0

0

0

0 -18 0

2307

100

LUMINANCE

Average Candela Degrees

Average 0° Luminance

45

9753

55

1395

65

571

75

318

85

0

Note: Refer to IES files for more product data.
PS517016EN page 5
March 8, 2024 6:07 PM

Photometric Data

HC6 | HM6 | 61 | 61PS
View IES files

WIDE DISTRIBUTION – SPECULAR CLEAR FINISH, 2000 LUMEN MODEL, 80 CRI, 3500K

WIDE (65° BEAM*)

Test Number

P581885

Housing HC620D010

Module HM60525835

Reflector 61WDC

Lumens Efficacy SC UGR

2359 Lm 118 Lm/W 1.28 11.6

CANDLEPOWER DISTRIBUTION Downlight

1876 1407
938 469
0

0-deg

180° 170°160° 150° 140° 130° 120° 110°
100°
90°
80°
70° 60° 50° 40° 30° 0° 10° 20°
45-deg 90-deg

CONE OF LIGHT

D

MH FC

L

W

5.5′ 50.5 7

7

7′ 31.2 8.8 8.8

8′ 23.9 10.2 10.2

9′ 18.8 11.4 11.4

10′ 15.3 12.8 12.8

12′ 10.6 15.4 15.4

CANDELA TABLE

Degrees Vertical
0 5 15 25 35 45 55 65 75 85 90

Candela
1526 1540 1685 1861 1027 252
32 6 2 0 0

*Value are nominal with specular clear reflectors, other finishes and field results may vary. SC = Spacing Criteria
UGR = Unified Glare Rating

ZONAL LUMEN SUMMARY

Zone Lumens % Fixture

0-30

1461

61.9

0-40

2105

89.2

0-60

2351

99.6

0-90

2359

100

9 0 -18 0

0

0

0 -18 0

2359

100

LUMINANCE

Average Candela Degrees

Average 0° Luminance

45

19506

55

3078

65

765

75

318

85

0

Photometric Multipliers (Nominal Lumen Values)

500 Lumen

750 Lumen

1000 Lumen

1500 Lumen

0.33

0.44

0.54

0.74

2000 Lumen 1.00

2500 Lumen 1.12

3000 Lumen 1.46

3500 Lumen 1.76

4000 Lumen

4500 Lumen

5000 Lumen

5500 Lumen

1.81

2.17

2.28

2.38

Multipliers for relative lumen values with other series models.

6000 Lumen 2.65

Color Finish Multipliers

Finish code

C

H

W/WB

BB

Finish

Specular Clear

Semi-Specular

Matte White White Baffle

Black Baffle

Multiplier

1.00

0.92

0.91

0.82

Multipliers for relative lumen values with other color finishes.

CCT Multipliers ­ 80CRI

2700K

3000K

3500K

4000K

0.92

0.98

1.00

1.03

Multipliers for relative lumen values with other series color temperatures.

5000K 1.03

CCT Multipliers ­ 90CRI

2700K

3000K

3500K

4000K

0.77

0.84

0.89

0.90

Multipliers for relative lumen values with other series color temperatures.

5000K 0.90

Note: Refer to IES files for more product data.
PS517016EN page 6
March 8, 2024 6:07 PM

Photometric Data

HC6 | HM6 | 61 | 61PS
View IES files

WALL WASH DISTRIBUTION – SPECULAR CLEAR FINISH, 2000 LUMEN MODEL, 80 CRI, 3500K

WALL WASH

Test Number

P581882

Housing HC620D010

Module HM60525835

Reflector 61RWWC

Lumens Efficacy SC

2179 Lm 109 Lm/W 1.15

CANDLEPOWER DISTRIBUTION Downlight

1112 834 556 278 0

0-deg

180° 170°160° 150° 140° 130° 120° 110°
100°
90°
80°
70° 60° 50° 40° 30° 0° 10° 20°
45-deg 90-deg

CANDELA TABLE

Degrees Vertical
0 5 15 25 35 45 55 65 75

Candela
1080 1081 1112 1034 800 514 319 184
85

85

12

90

0

ZONAL LUMEN SUMMARY

Zone Lumens % Fixture

0-30

849

39

0-40

1313

60.2

0-60

1978

90.8

0-90

2179

100

9 0 -18 0

0

0

0 -18 0

2179

100

LUMINANCE

Average Candela Degrees

Average 0° Luminance

45

39810

55

30479

65

23907

75

17983

85

7359

SC = Spacing Criteria, nominal for specular clear reflector, other finishes and field results may vary.

SINGLE UNIT FOOTCANDLES
2.5′ from wall (distance from fixture along wall)

1 19.3 13.8 6.1 2.2 0.7 0.3 0.1 2 29.1 22.6 12.3 5.7 2.5 1.2 0.6

3 27.6 22.5 13.8 7.3 3.7 1.9

1

4 21 18.2 12.4 7.4 4.2 2.4 1.4

5 14.4 13.1 9.9 6.6 4.1 2.5 1.6

6 9.7 9.1 7.5 5.5 3.7 2.5 1.6

7 6.7 6.4 5.5 4.3 3.2 2.2 1.5

8 4.7 4.6 4.1 3.4 2.7

2

1.4

9 3.4 3.3 3.1 2.7 2.2 1.7 1.3

10 2.5 2.5 2.4 2.1 1.8 1.4 1.1

MULTIPLE UNIT FOOTCANDLES

2.5′ from wall (Distance from fixture along
w3all)

1

21.5

19.1

21.5

2

34.7

34.4

34.7

3

34.9

36

34.9

4

28.4

30.7

28.4

5

21

23.2

21

6

15.2

16.8

15.2

7

11

12

11

2.5′ from wall (Distance from fixture along
w4all)

20

12.1

20

31.6

24.6

31.6

31.3

27.6

31.3

25.2

24.8

25.2

18.6

19.8

18.6

13.4

15

13.4

9.9

11

9.9

8

8.1

8.7

8.1

9

6.1

6.5

6.1

7.4

8.2

7.4

5.6

6.2

5.6

10 4.6

4.9

4.6

4.3

4.7

4.3

Photometric Multipliers (Nominal Lumen Values)

500 Lumen

750 Lumen

1000 Lumen

1500 Lumen

0.33

0.44

0.54

0.74

2000 Lumen 1.00

2500 Lumen 1.12

3000 Lumen 1.46

3500 Lumen 1.76

4000 Lumen

4500 Lumen

5000 Lumen

5500 Lumen

1.81

2.17

2.28

2.38

Multipliers for relative lumen values with other series models.

6000 Lumen 2.65

Color Finish Multipliers

Finish code

C

H

W/WB

BB

Finish

Specular Clear

Semi-Specular

Multiplier

1.00

0.92

Multipliers for relative lumen values with other color finishes.

Matte White White Baffle
0.91

Black Baffle 0.82

CCT Multipliers ­ 80CRI

2700K

3000K

3500K

4000K

0.92

0.98

1.00

1.03

Multipliers for relative lumen values with other series color temperatures.

5000K 1.03

CCT Multipliers ­ 90CRI

2700K

3000K

3500K

4000K

0.77

0.84

0.89

0.90

Multipliers for relative lumen values with other series color temperatures.

5000K 0.90

Note: Refer to IES files for more product data.

PS517016EN page 7
March 8, 2024 6:07 PM

Energy & Performance Data

COLOR METRICS – TM-30-15 & CRI/CIE (3500K) 80 CRI Color Metric Summary – 3500K*

TM-30-15

Rf = 86 Rg = 95.5

CRI/CIE

Ra = 83.8 R9 = 10.3

2700K 3000K 3500K 4000K 5000K

HC6 | HM6 | 61 | 61PS

90 CRI Color Metric Summary – 3500K*

TM-30-15

Rf = 91.1 Rg = 99

CRI/CIE

Ra = 92.4 R9 = 55.1

2700K 3000K 3500K 4000K 5000K

Reference Illuminant

Test Source

55° 60°
narrow medium Nominal Beam

65°
wide

ENERGY DATA
Series Input Voltage 120-277VAC Input Current (A) Input Power (W) In-rush (A) Inrush duration (µs) THD (%) PF

500 lumen

120V

277V

0.051

0.026

6.1

6.5

1.9

8.4

251

135

6.2

13.5

0.99

0.9

750 lumen

120V

277V

0.067

0.036

7.9

8.3

2

8.4

237

133

7.4

8.8

0.98

0.92

Reference Illuminant

Test Source

55° 60°
narrow medium Nominal Beam

65°
wide

  • Color values are based on 61WDWB reflector, other finishes and field results may vary.

1000 lumen

120V

277V

0.083

0.039

10

10.4

2.2

8.5

250

134

5.4

10.3

0.99

0.95

1500 lumen

120V

277V

0.119

0.053

14.5

14.5

2.7

8.5

250

139

10

6.7

0.99

0.97

2000 lumen

120V

277V

0.171

0.077

20.9

20.6

2.1

9.7

245

131

6.5

7.9

0.99

0.96

Series Input Voltage 120-277VAC Input Current (A) Input Power (W) In-rush (A) Inrush duration (µs) THD (%) PF

2500 lumen

120V

277V

0.23

0.103

27.5

27.5

2.5

5.6

232

123

6.5

8.1

0.99

0.96

3000 lumen

120V

277V

0.24

0.107

28.6

28.5

2.5

11.6

216

111

7.8

8.3

0.99

0.96

3500 lumen

120V

277V

0.292

0.152

34.6

35.1

3.4

13.9

183

95

5.6

10

0.99

0.93

4000 lumen

120V

277V

0.351

0.159

42.1

42.1

3.1

14.7

200

98

4.1

9.5

0.99

0.94

4500 lumen

120V

277V

0.384

0.172

45.9

45.6

3.1

14.8

202

100

4.5

8.5

0.99

0.95

Series Input Voltage 120-277VAC Input Current (A) Input Power (W) In-rush (A) Inrush duration (µs) THD (%) PF

5000 lumen

120V

277V

0.419

0.186

50.1

49.5

3.1

15

202

117

5.5

7.6

0.99

0.96

5500 lumen

120V

277V

0.457

0.201

54.6

53.7

3.2

14.8

196

131

7

7.2

0.99

0.96

Minimum starting temperature -30°C (-22°F)* (Nominal input 120-277VAC & 100% of rated output power)
Sound Rating: Class A standards

Notes: * Emergency Battery packs are rated for a minimum starting temperature of 0°C.

6000 lumen

120V

277V

0.489

0.214

58.4

57.4

3.4

14.8

192

121

8.1

7.2

0.99

0.97

PS517016EN page 8
March 8, 2024 6:07 PM

Dimensional and Mounting Details
NEW CONSTRUCTIONS – LOW LUMEN 500 ­ 2500 LUMENS

NEW CONSTRUCTION – LOW LUMEN 500 ­ 2500 LUMENS

max module height
(see table)

4.2″ [107.34mm] hanger bar bracket

LED height (see table)

3.42″ [86.77mm]

height (removable)

(driver height)

.5″ [12.70mm] (ceiling thickness)

6.06″ [153.92mm] (reflector inner aperture)
7.25″ [184.15mm] (ceiling cut out)
7.75″ [196.85mm] (trim flange)

NEW CONSTRUCTIONS – MID LUMEN 3000 ­ 4000 LUMENS

NEW CONSTRUCTION – MID LUMEN 3000 AND 4000 LUMEN
max module height (see table)

LED height (see table) 3.42″
[86.77mm] (driver height)

.5″ [12.70mm] (ceiling thickness)

6.06″ [153.92mm] (reflector inner aperture)
7.25″ [184.15mm] (ceiling cut out)
7.75″ [196.85mm] (trim flange)

NEW CONSTRUCTIONS – HIGH LUMEN 4500 ­ 6000 LUMENS

NEW CONSTRUCTION – HIGH LUMEN 4500 ­ 6000 LUMEN
max module height (see table)
LED height (see table) 3.42″
[86.77mm] (driver height)
.5″ [12.70mm] (ceiling thickness)

6.05″ [153.72mm] (reflector inner aperture)
7.25″ [184.15mm] (ceiling cut out)
7.75″ [196.85mm] (trim flange)

HC6 | HM6 | 61 | 61PS

Low Lumen (500 ­ 2500 Lumens)*

trim height (see table)

Distribution Narrow Medium Wide

Max. Module Height

Trim Height

4.5″

3.4″

4.6″

3.5″

4.4″

3.3″

LED Height 3.8″ 3.9″ 3.7″

Baffle

4.4″

3.3″

3.7″

*Max. height w/removable hanger bar bracket 4.2″

Low Lumen Module

trim height (see table)

Mid Lumen (3000 ­ 4000 Lumens)

Distribution Narrow Medium Wide

Max. Module Height

Trim Height

6.6″

3.4″

6.7″

3.5″

6.5″

3.3″

Baffle

6.5″

3.3″

LED Height
3.8″ 3.9″ 3.7″ 3.7″

Mid Lumen Module

trim height (see table)

High Lumen (4500 ­ 6000 Lumens)

Distribution Narrow Medium Wide Baffle

Max. Module Height

Trim Height

6.9″

3.4″

7.0″

3.5″

6.8″

3.3″

6.8″

3.3″

LED Height 3.8″ 3.9″ 3.7″ 3.7″

High Lumen Module

PS517016EN page 9
March 8, 2024 6:07 PM

Connected Solutions WaveLinx LITE – WTK Tilemount Sensor

HC6 | HM6 | 61 | 61PS

· Intuitive AndroidTM or Apple® iOS® app for basic system code compliant set up and configuration via Bluetooth · Up to 28 unique areas per project site (WaveLinx LITE Bluetooth network) · Up to 50 devices for an area, any one of 16 control zones, up to 6 occupancy sets, and custom lighting scenes · Automatic occupancy or vacancy, sensor sensitivity, daylight dimming, etc. configurable through the app · Refer to the WaveLinx system specifications for details

Device Security

Manual Dimmer

Occupancy Sensor

Daylighting Control

Manually Switched ON/OFF

Tuning Control

Lumen Maintenance Control

Scenes

WaveLinx LITE WTK Tilemount Wiring Diagram

WaveLinx LITE Bluetooth Enabled System

120-277 VAC

Black (Hot) White (Neutral)

Control module (MSP3IVMVDC1EP)

Pink (Dimming) Purple (Dimming) Blue (Not Switched) White (Neutral)

Includes switchleg (Blue load out wire) and 0-10V to each fixture controlled

0-10V DImming Driver

120-277 VAC 3A downlights with 0-10V control

WaveLinx LITE Tilemount Sensor Kit control module
(MSP3IVMVDC1EP) (included)

54″ Plenum cable (5140-000123-00)
(included)

ceiling tile

ceiling tile ceiling cutaway view

WaveLinx LITE Sensor and Mounting Trim (included)

MyApps
Secure Portal
Site Initiation, Data Backup & Site Transfer
WaveLinx LITE Mobile Application

WaveLinx LITE Ambient

WaveLinx LITE Integrated Ambient

WaveLinx LITE Tilemount Sensor Kit

WaveLinx LITE Wallstation

WaveLinx LITE Integrated Industrial

WaveLinx LITE Integrated
Parking Garage

WaveLinx PRO ­ WTA Tilemount Sensor

· WaveLinx PRO tilemount functionality configures zones and customizes settings from one secure mobile app · Automatic code commissioning that meets the strictest codes · Fixtures and sensors integrate with Wireless Area Controller, Wall Stations, and Control Devices · Stand-Alone Offices or Entire Building Network Installations

  • Downlights with tilemount sensor wireless communication
    Highly efficient LED fixtures

++

WaveLinx Area Controller
Provides centralized coordination of multiple
area control options

Wireless Wall Station/Receptacle
Provides customized wireless control of each area

Mobile Applications
Provides personalized, local control from a tablet or smartphone

WaveLinx mobile app settings

Manual Dimmer

Occupancy Sensor

Lumen Maintenance Control

Daylighting Control

Receptacle Control

Tuning Control

Scheduling

Manually Switched ON/OFF

Demand Response

WaveLinx WTA Tilemount Wiring Diagram

120-277 VAC

Black (Hot) White (Neutral)

Control module (MSP3IVMVDC1EP)

Pink (Dimming) Purple (Dimming) Blue (Not Switched) White (Neutral)

Includes switchleg (Blue load out wire) and 0-10V to each fixture controlled

0-10V DImming Driver

120-277 VAC 3A downlights with 0-10V control

WaveLinx Tilemount Sensor Kit control module
(MSP3IVMVDC1EP) (included)

54” Plenum cable (5140-000123-00)
(included)

ceiling tile

ceiling tile

WaveLinx Sensor and Mounting Trim (included)

WaveLinx CORE Building Management Integration

BACnet/IP Public (REST) API

Desktop/Laptop
with web browser (hardware provided
by user)

WaveLinx CORE

Third Party system (hardware provided by others) Building LAN
Touchscreen

BACnet Router1 (hardware provided by others)
PoE Power

WaveLinx Area
Controller

Smartphone with WaveLinx app

used for system

setup and

personal control

Area or Room

(49 + 1 construction area)

Area or Room
(49 + 1 construction area)

Area or Room
(49 + 1 construction area)

120-347V 20A PRO Dimming Switchpacks

PRO Occupancy Ceiling Sensor

WaveLinx PRO controlled devices
(up to 200 devices per WAC2 – 150 devices best practice) – see Note

PRO Controlled Receptacle

PRO Wallstation

WaveLinx PRO enabled Indoor Fixture

WaveLinx PRO enabled Outdoor Fixture

KEY
Wi-Fi Signal
IEEE 802.15.4
Note: Performance based on second generation WaveLinx Area Controller (WAC2). WaveLinx CORE Pro shown in this illustration. WaveLinx CORE hardware can be either Pro, Enterprise or Virtual. 1 BACnet Router only required if WaveLinx CORE and third party BACnet client are on different subnets.

PS517016EN page 10
March 8, 2024 6:07 PM

HC6 | HM6 | 61 | 61PS

Connected Solutions

WaveLinx LITE Wireless Node – WLN

· Intuitive AndroidTM or Apple® iOS® app for basic system code compliant set up and configuration via Bluetooth
· Up to 28 unique areas per project site (WaveLinx LITE Bluetooth network)

· Up to 50 devices for an area, any one of 16 control zones, up to 6 occupancy sets, and custom lighting scenes
· Refer to the WaveLinx system specifications for details

WaveLinx mobile app settings

  • Downlights with wireless communication
    Highly efficient LED fixtures

++

WaveLinx Area Controller
Provides centralized coordination of multiple
area control options

Wireless Wall Station/Receptacle
Provides customized wireless control of each area

Mobile Applications
Provides personalized, local control from a tablet or smartphone

Device Security

Manual Dimmer

Occupancy Sensor

Daylighting Control

Manually Switched ON/OFF

Tuning Control

Lumen Maintenance Control

Scenes

WaveLinx LITE Wireless Node (WLN) Wiring Diagram

WaveLinx LITE Bluetooth Enabled System

WPN Grey (GND)

MyApps
Secure Portal
Site Initiation, Data Backup & Site Transfer

Yellow (Aux-) Grey (Aux-) Pink (Dim-) Purple (Dim+)

Gree n (GND) White (AC -N) Black (AC-L)

D010

Red (LED+) Blue (LED-)

WaveLinx LITE Mobile Application

WaveLinx PRO Wireless Node – WPN

WaveLinx LITE Ambient

WaveLinx LITE Integrated Ambient

WaveLinx LITE Tilemount Sensor Kit

WaveLinx LITE Wallstation

WaveLinx LITE Integrated Industrial

WaveLinx LITE Integrated
Parking Garage

· WaveLinx Wireless functionality configures zones and customizes settings from one secure mobile app
· Automatic code commissioning that meets the strictest codes

· Fixtures and sensors integrate with WaveLinx Area Controller, Wall Stations, and Control Devices
· Stand-Alone Offices or Entire Building Network Installations

  • Downlights with wireless communication
    Highly efficient LED fixtures

++

WaveLinx Area Controller
Provides centralized coordination of multiple
area control options

Wireless Wall Station/Receptacle
Provides customized wireless control of each area

Mobile Applications
Provides personalized, local control from a tablet or smartphone

WaveLinx mobile app settings

Manual Dimmer

Occupancy Sensor

Lumen Maintenance Control

Daylighting Control

Receptacle Control

Tuning Control

Scheduling

Manually Switched ON/OFF

Demand Response

WaveLinx PRO Wireless Node (WPN) Wiring Diagram

WaveLinx CORE Building Management Integration

WPN Grey (GND)

BACnet/IP Public (REST) API

Desktop/Laptop
with web browser
(hardware provided
by user)

Trellix Core

Yellow (Aux-) Grey (Aux-) Pink (Dim-) Purple (Dim+)

Gree n (GND) White (AC -N) Black (AC-L)

D010

Red (LED+) Blue (LED-)

Third Party system
(hardware provided by others)
Building LAN
Touchscreen

BACnet Router1
(hardware provided by others)
PoE Power

WaveLinx Mobile App used for system setup and personal control

Wireless Area Controller

Cooper Lighting Solutions 1121 Highway 74 South Peachtree City, GA 30269 P: 770-486-4800 www.cooperlighting.com

© 2024 Cooper Lighting Solutions All Rights Reserved.
Specifications and dimensions subject to change without notice.

PS517016EN page 11
March 8, 2024 6:07 PM

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals