SD-7104SGEX1Q Vandal Resistant Push Exit Plates

ENFORCER SD-7104SGEX1Q Vandal Resistant Push Exit
Plates

Features:

  • Switch contact rating: 50A@24VAC
  • Equipped with NO/NC (DPST) switch
  • “EXIT” and “SALIDA” silk-screened on plate (except SD-7304SGEX1Q)
  • Available with slimline, single-gang, and European plates
  • Vandal-resistant 1″ (25mm) pushbutton switch

Installation:

Please read the manual carefully before beginning installation.

  1. Run two wires through the wall to the back box.
  2. Connect wires to either 1-2 (N.C.) or 3-4 (N.O.).
  3. For weather-resistant installation, use a waterproof back box and apply a bead of silicone sealant where the back box contacts the faceplate and around the faceplate mounting screws.
  4. Screw plate to the back-box, using caution not to pinch any wires.

NOTE: Use only low-voltage, power-limited/Class 2 power supply and low- voltage field wiring not to exceed 98.5ft (30m).

Parts List:

1x Push-to-exit button / faceplate
4x Crimp-style connectors
2x Mounting screws
1x Manual

Specifications:

Model SD-7104SGEX1Q SD-7204SGEX1Q SD-7304SGEX1Q
Plate Slimline Single-gang European
Contact rating 50A@24VAC
Switch type NO/NC
Destructive attack level Level I
Line security Level I
Endurance level Level I
Standby power Level I
IP Rating IP65
Operating temperature -40-140° F (-20°-60° C)
Dimensions 41/2″x19/16″x13/16″ (115x39x20 mm) 41/2″x23/4″x213/16″ (115x70x20
mm) 33/8″x33/8″x13/16″ (86x86x20 mm)

Dimensions:

Connections:

Sample Installations:

  1. Installation with an Electromagnetic LockENFORCER SD-7104SGEX1Q Vandal Resistant Push Exit Plates - parts2 NOTE: Use only low-voltage, power-limited/Class 2 power supply and low-voltage field wiring not to exceed 98.5ft (30m).
  2. Installation with an Electromagnetic Lock and KeypadENFORCER SD-7104SGEX1Q Vandal Resistant Push Exit Plates - parts3 NOTE: Use only low-voltage, power-limited/Class 2 power supply and low-voltage field wiring not to exceed 98.5ft (30m).
  3. Installation with an Electric Door StrikeENFORCER SD-7104SGEX1Q Vandal Resistant Push Exit Plates - parts4 NOTE: Use only low-voltage, power-limited/Class 2 power supply and low-voltage field wiring not to exceed 98.5ft (30m).

California Proposition 65 Warning: These products may contain chemicals which are known to the State of California to cause cancer and birth defects or other reproductive harm. For more information, go to www.P65Warnings.ca.gov.
IMPORTANT WARNING: For a weather-resistant installation, ensure that the unit is installed in a waterproof back box, and that the faceplate and faceplate screws are properly sealed. Incorrect mounting may lead to exposure to rain or moisture in the enclosure which could cause a dangerous electric shock, damage the device, and void the warranty. Users and installers are responsible for ensuring that this product is properly installed and sealed.
IMPORTANT: Users and installers of this product are responsible for ensuring that the installation and configuration of this product complies with all national, state, and local laws and codes related to locking and egress devices. SECO-LARM will not be held responsible for the use of this product in violation of any current laws or codes.
WARRANTY: This SECO-LARM product is warranted against defects in material and workmanship while used in normal service for one (1) year from the date of sale to the original customer. SECO-LARM’s obligation is limited to the repair or replacement of any defective part if the unit is returned, transportation prepaid, to SECO-LARM. This Warranty is void if damage is caused by or attributed to acts of God, physical or electrical misuse or abuse, neglect, repair or alteration, improper or abnormal usage, or faulty installation, or if for any other reason SECO-LARM determines that such equipment is not operating properly as a result of causes other than defects in material and workmanship. The sole obligation of SECO-LARM and the purchaser’s exclusive remedy, shall be limited to the replacement or repair only, at SECO-LARM’s option. In no event shall SECO-LARM be liable for any special, collateral, incidental, or consequential personal or property damage of any kind to the purchaser or anyone else.
NOTICE: The SECO-LARM policy is one of continual development and improvement. For that reason, SECO-LARM reserves the right to change specifications without notice. SECO-LARM is also not responsible for misprints. All trademarks are the property of SECO-LARM U.S.A., Inc. or their respective owners. Copyright © 2023 SECO-LARM U.S.A., Inc. All rights reserved.

ENFORCER logoSECO-LARM ® U.S.A., Inc.
16842 Millikan Avenue, Irvine, CA 92606
Phone: 949-261-2999 | 800-662-0800
Website: www.seco-larm.com
Email: sales@seco-larm.com
PITSW1
Order Part# 763-158-6%
MI_SD-7x04SGEX1Q_220909.docx
SECO-LARM U.S.A., Inc.

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

ENFORCER User Manuals

Related Manuals