Specifications
Dimensions
- Includes one 3VDC lithium battery (CR-2032)
- HL-951T1-SWO may also be powered by an external 4.5-13 VDC output regulated adapter (not included)
- Frequency-917MHz
- Operating range up to 1,800ft (550m)
- LED transmission and low-battery indicator
- Compact size
- Compatible with all SECO-LARM HL-series receivers of the same frequency
- Also available without logo –
- HL-951T1-SWUQ – 917MHz, Wired
- HL-951T1-SDUQ – 917MHz, DIP-Switch
Actual range will vary depending on the installation and operating environment
DIP Switch Coding
- The HL-951T1-SDQ can be programmed to one of 254 unique codes using an 8-pin DIP switch (see PCB diagram and detail right).
- Open the case and set the switch as desired (default, 1- ON, 2-8- OFF).
NOTE: DIP switch cannot be set all ON or all OFF.
Sample Applications
Make any push-to-exit plate wireless
Convert photo beam sensors with dry contacts into an entry alert
Wireless doorbell/ service call button
Installation
Power Connection
The HL-951T1-SWa can be powered by the factory preinstalled 3VDC lithium
battery (CR-2032) or by an external 4.5-13VDC output regulated adapter (not
included). When using an external power adapter with the HL-951T1-SWa, correct
polarity is imperative. Connect the transmitter’s red wire to the adapter’s
positive Output and the black wire to the adapter’s negative output.
NOTES:
- The power input range of the wired transmitter is 4.5-13VDC and is polarity sensitive. Connecting more than 13VDC or reversing the polarity will burn out the unit and void the warranty.
- Use only “regulated” adapters to power the wired transmitter.
- If using an external power adapter, the factory-installed lithium CR-2032 battery will serve as a backup in case of power interruption (Battery must be removed for external inline power-on switch).
- The LED indicator will flash slowly to indicate a low battery.
- If connected to an external power-on switch, it is suggested that you remove the battery to disable the built-in button so that it can only be controlled by the power-on switch (see Fig. 2).
Code Learning a New Transmitter Button:
- Enter programming mode and select the desired channel as described on pg. 1.
- While the LED is flashing, press the desired transmitter button to be leamed one time. The three horizontal bars of the receiver’s LED indicator will flash two times to indicate the transmitter button has been successfully learned and will automatically exit leaming mode. To learn further codes, re-enter programming mode and repeat.
NOTES:
- Do not press the selection button again after entering programming mode as this will take you to output mode programming.
- The indicator LED will fiash a maximum of 15 seconds. If no transmitter button is pressed during this time, the receiver will exit code programming mode, and the LED will turn off.
- If the code has already been learned, the indicator LED will slowly flash two dashes. The code will not be leaned a second time.
- One channel can leam the codes of a maximum of 99 transmitter buttons. If you attempt to lean an additional transmitter code, the earliest code learned will be deleted and the new code will be learned.
External Switch Connection
The wired transmitter can be controlled by its built-in button (see Fig. 1),
by an external N.O. switch” only (button, contact, or sensor, see Fig. 2), or
by both (Fig. 3). To disable the built-in button, the external switch must be
installed inline to the positive terminal of the power source with the battery
removed.
NOTES:
- Any wires not in use must be insulated to avoid a short-circuit.
- Do not let the red wire touch any other wire. Doing so may burn out the transmitter.
- For the HL-9511T1-SDQ, the DIP switches cannot be set to all ON or all OFF.
Switch not included
FCC COMPLIANCE STATEMENT
This device complies with part 15 of the FCC rules. operation is subject to
the following two conditions: (1) this device may not cause harmful
interference and (2) this device must
accept any interference received, including interference that may cause
undesired operation.
Notice: The changes or modifications not expressly approved by the party
responsible for compliance could void the user’s authority to operate the
equipment
IMPORTANT NOTE: To comply with the FCC RF exposure compliance
requirements, no change to the antenna or the device is permitted. Any change
to the antenna or the device.
FCC ID: K4E951T1SW could result in the device exceeding the RF exposure
requirements and void users’ authority to operate the device
California Proposition 65 warning: these products may contain chemicals that
are known to the State of California to cause cancer and birth defects or
other reproductive harm. For more information, go to
wwww.PGSVWarnings.ca.gov
WARRANTY: This SECO-LARM product is warranted against defects in material
and workmanship while used in normal service for one (1) year from the date of
sale to the original customer. SECO-LARM’S obligation is limited to the repair
or replacement of any defective part the unit is returned, transportation
prepaid, to SECO-LARM. This Warranty is void I damage is caused by or
attributed to acts of God, physical or electrical misuse or abuse, neglect,
repair or alteration, improper or abnormal usage, or faulty installation, or
if for any other reason Sedo-LARM determines that such equipment is not
operating properly as a result of causes other than defects in material and
workmanship. The sole obligation of SECO-LARM and the purchaser’s exclusive
remedy shall be limited to the replacement or repair onty, at SECO-LARM’s
option. In no event shall SECO-LARM be liable for any special, collateral,
incidental, or consequential personal or property damage of any kind to the
purchaser or anyone else.
NOTICE: The SECO-LARM policy is one of continual development and
improvement. For that reason, SECO-LARM reserves the right to change
specifications without notice. SECO-LARM is also not responsible for
misprints. All trademarks are the property of SECO-LARM U.SA., Inc. or their
respective owners. Copyright e 2022 SECO-LARM U.S.A., Inc. All rights reserved
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>