INTRODUCTION

  1. temperature sensor
  2. display
  3. battery compartment
  4. on/off button
  • This Fysic FT09 thermometer is a digital thermometer developed to  take your temperature as simply  and accurately as possible. In order to get the most reliable results,  these instructions must be followed accurately. For the most accurate temperature reading, we recommend using the thermometer rectally. Although the generally accepted  ‘normal’ temperature is 37.0°C, body temperature can vary from 36.1°C to 37.2°C.
  • Fluctuations in temperature can be due to activities such as sports, smoking, eating and drinking, and also depend on the part of the body where the temperature is taken. When measured orally, the body temperature is generally 0.5°C lower than when measured rectally, while a temperature measured under the armpit is 1.0°C lower. Your temperature is lower in the morning than in the evening.

SPECIFICATIONS

  • Temperature range: 32.0°C – 42.9°C
  • Low temperature display: (≤ 32°C): Lo°C
  • High temperature display: (≥ 42,9°C): HI°C
  • Display resolution: 0.1°C
  • Accuracy: 37°C – 39°C = ±0.1°C <35.3°C + >41°C = ±0.3°C 35.3°C – 36.9°C + 39.1°C – 41°C = ±0.2°C
  • Normal temperature: ≤ 37.4°C: 3 beeps
  • Fever alarm: ≥ 37.5°C: 8 fast beep
  • Auto-OFF: 60 seconds
  • Battery: CR-2032, 3V
  • Dimensions: 136 x 35 x 21 mm
  • Weight: ±20 gr (batt incl.)
  • Conditions for use: 10°C – 35°C, ≤75% RH
  • Storage conditions: -20°C – 55°C, ≤83% RH

CHANGE THE MEASURING UNIT

To switch the unit between °C and °F, turn the thermometer off. Press and hold the ON/OFF button until the LCD shows “C or F”, then release the button. And press the button to choose the unit, the chosen unit will flash. After a few seconds the display will turn off.

MEASURING YOUR TEMPERATURE

  1. Take the thermometer out of the holder.
  2. Press the ON/OFF key once to activate the thermometer. You will hear a beep.
  3. The display shows in succession:
    • ‘188.8°C’ / ‘188.8°F’
    •  the last measured temperature
    • ‘LO’ and flashing ‘°C’ / ‘°F’ (*)
  4. Place the thermometer in the chosen body part to measure your temperature.
  5. When you hear beeps, your temperature has been recorded.
    • if your body temperature is normal, you will hear 3 beeps
    • if your body temperature is above normal (≥37,8°C), you will hear 9 rapid beeps
    • Press the ON/OFF key to switch off the thermometer.
      (The thermometer will switch off automatically after approx. 60 seconds).
      If the room temperature is higher than 32.0°C, the room temperature will be shown instead of ‘Lo’.

Measurement under the tongue:

  • Place the mometer under the tongue, as far back as possible to the left or right.
  • A temperature taken under the tongue is approx. 0.5°C lower than when taken rectally.

Measurement under the arm

  • Make sure the armpit is dry and place the thermometer under the arm. The sensor must touch the skin. Keep your arm crossed in front of your chest.
  • A temperature taken under the tongue is approx. 1.0°C lower than when taken rectally.

Rectal measurement
Insert the thermometer sensor gently
(maximum 1.25 cm).

BATTERY REPLACEMENT

The battery is empty and needs replacing when the symbol appears on the left of the LCD.

  1. using a philips screwdriver unscrew the battery cover.
  2. Open the battery cover, and remove the battery.
  3. Put a new CR2032 battery in, screw the battery cover back in place Please note: The “+” sign up and “-” sign down.

Do not throw away empty or leftover batteries, but instead hand them in to your local depot for Household Chemical Waste.

ADVICE AND WARNINGS

  • Keep the thermometer and battery out of the reach of children.
  • Do not talk or walk around while taking your temperature.
  • Store the thermometer in the holder.
  •  Do not expose the thermometer to direct sunlight, dust or moisture.
  • Do not dismantle the thermometer.

STORAGE AND CLEANING

Clean the thermometer before and after use, using a soft cloth and alcohol, or cold soapy water. The thermometer may be briefly immersed in water or alcohol (do not soak or sterilise). Store the thermometer in the special case.

CE

The declaration of conformity is available at: http://DOC.hesdo.com/FT09-DOC.pdf

ATTENTION

  • Ensure that button cell batteries are NEVER swallowed by babies or young children. Keep (button cell) batteries far away from babies and children at all times and always discard used batteries at a dedicated collection point.
  • If you have any doubt about your baby or child having swallowed a button cell battery, immediately consult your doctor.

WARRANTY

  • For the Fysic FT09 thermometer you have a warranty of 24 months from the date of purchase. During this period, we guarantee the free repair of defects caused by material and workmanship errors. All this subjected to the final assessment of the importer.
  • HOW TO HANDLE: If you notice any defect, first refer to the user’s manual. Please contact the supplier of this thermometer or contact customer service of Alecto via the Internet www.alecto.nl
  • THE WARRANTY BECOMES NULL AND VOID: In case of improper use, incorrect connections, leaking and/ or incorrectly installed batteries, use of unoriginal parts or accessories, negligence and in case of defects caused by moisture, fire, flooding, lightning and natural disasters.
  • In case of unauthorised modifications and/or repairs performed by third parties. In case of incorrect transportation of the device without adequate packaging and when the device is not accompanied by this warranty card and proof of purchase. All further liability, especially concerning any consequential damages, is excluded.

Service Help

  • WEB
  • PH:
    • NL 073 6411 355 (Lokaal tarief)
    • BE 03 238 5666 (Lokaal tarief) (Tarif local)
    • DE 0180 503 0085 Lokale Festnetzkosten
  • ADD:
    • Hesdo, Australiëlaan 1 5232 BB, ‘s-Hertogenbosch
    • The Netherlands

ABOUT COMPANY

  • Dong Guan City Good Health Electronic Technology Co., Ltd. 3&4 Floor, B Building, Chang Huang Road, Qiaoli village, Changping Town, Dong Guan City, Guangdong Province, China Model: HK-909
  • Shanghai International Holding Corp. GmbH, Eiffestrasse 80, 20537 Hamburg Germany
  • Imported by: Hesdo bv. Azielaan 12, 5232BA ‘s-Hertogenbosch The Netherlands

References