BEGA 50 657 Ceiling and Wall Luminaire for Indoor Use Instruction Manual

June 12, 2024
BEGA

BEGA 50 657 Ceiling and Wall Luminaire for Indoor Use Instruction Manual

BEGA

Decken- und Wandleuchte für die Verwendung im Innenbereich
Ceiling and wall luminaire for indoor use Plafonnier et applique pour utilisation à l’intérieur

Instructions for use

Application

Ceiling and wall luminaire · indoor luminaire made of hand-blown opal glass, satin matt and aluminium alloy housing, for all lighting tasks. They are ideal for places where a soft and uniform lighting distribution is required.

Luminaire with a high protection class.


Product description

Luminaire made of aluminium alloy Finish Colour white

Hand-blown opal glass, satin matt,

with sliding-bolt closure

2 mounting holes ø 5.5 mm Distance apart 280 mm

2 cable entries for through-wiring for mains cable up to ø 10,5 mm max. 5 x 1.5@ Connection terminal 2.5@

Earth conductor connection

2-pole connecting terminal for digital control

LED power supply unit 220-240 V x 0/50-60 Hz DC 170-276 V

DALI-controllable

Basic insulation is provided between the mains and control cables

BEGA Thermal Control®

Temporary thermal regulation to protect temperature-sensitive components without switching off the luminaire

Safety class I Protection class IP 44

Protected against granular foreign bodies

³ 1 mm and splash water Impact strength IK06 Protection against mechanical impacts < 1 joule

r – Safety mark c – Conformity mark Weight: 4.2 kg

This product contains light sources of energy

efficiency classes D

Safety

The installation and operation of this luminaire are subject to national safety regulations.

Installation and commissioning may only be

carried out by a qualified electrician.

The manufacturer accepts no liability for damage caused by improper use or installation.

If subsequent modifications are made to the luminaire, the person responsible for these modifications shall be considered the manufacturer.


Overvoltage protection

The electronic components installed in the luminaire are protected against overvoltage in accordance with DIN EN 61547.

To achieve an additional protection against

e. g. transients, etc. we recommend separate overvoltage protection components.

You can find them on our website at

www.bega.com.

Lamp

Module connected wattage                  40.4 W

Luminaire connected wattage                      45 W

Rated temperature                            ta = 25 °C

Ambient temperature                    ta max = 40 °C

50 657 K27

Module designation                 4x LED-0262/927

Colour temperature                              2700 K

Colour rendering index                           CRI > 90

Module luminous flux                             6560 lm

Luminaire luminous flux                          4383 lm Luminaire luminous efficiency         97,4 lm / W

50 657 K3

Module designation                 4x LED-0262/930

Colour temperature                              3000 K

Colour rendering index                           CRI > 90

Module luminous flux                             6660 lm

Luminaire luminous flux                          4324 lm Luminaire luminous efficiency         96,1 lm / W


Installation

LED are high-quality electronic components! Please avoid touching the light output opening of the LED directly during installation or relamping.

Lead mains supply cable through the cable entry into the luminaire housing.

Fix the luminaire housing with enclosed or any other suitable fixing material onto the mounting surface.

It is imperative to use the enclosed gaskets. Make earth conductor connection.

Push silicone sleeves over the lines and make electrical connection.

For digital control please use the connecting

terminal DA, DA.

In case this terminal is not used the luminaire will be operated at full light output.

Insert the opal glass into the luminaire housing with sliding bolt glass closure and turn the glass clockwise up to the stop.

Place glass to the luminaire housing and observe that the holding springbolts fit into the notches of the glass.

Turn the glass clockwise until it is locked. Thus, you reach a safe and vibration-resistant holding of the glass.

To release the glass from the luminaire housing, turn it counter-clockwise.

Replacement of the LED module ·

Maintenance

The designation of the LED module is noted on a label in the luminaire.

The light colour and light output of BEGA replacement modules correspond to those of the modules originally fitted. The module can be replaced by qualified persons using standard tools.

Disconnect the system.

Unscrew glass from luminaire housing by turning it counter-clockwise.

Clean glass and luminaire regularly with solvent-free cleansers from dirt.

Please follow the installation instructions for the LED module.

Screw in glass by turning it clockwise as far as it will go.

A broken glass must be replaced.


Spares

Spare glass                                                    11 002 126 .0R G
LED power supply unit                            DEV-0391/1050
LED module 2700 K                                 LED-0262/927

LED module 3000 K                                 LED-0262/930

Read More About This Manual & Download PDF:

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

BEGA User Manuals

Related Manuals