SHOWVEN Sparkular MiniFall 130 Watt Waterfall DMX Cold Spark Machine User Manual

June 5, 2024
Showven

SHOWVEN Sparkular MiniFall 130 Watt Waterfall DMX Cold Spark Machine

Safety Considerations

  • Never touch the nozzle of SPARKULAR miniFALL, the danger of getting burnt;
  • Never touch the sparks which shoot out from the nozzle.
  • Unauthorized repair are prohibited, it may cause a serious incident.
  • Keep SPARKULAR miniFALL dry and do NOT use in rain or snow.
  • Make sure lid of feeding hopper are well covered when use SPARKULAR miniFALL. Accidentally burning of Composite Ti can only use sands to extinguish. Composite Ti should keep away from moisture and stored in a dry sealed environment.
  • Keep audience and flammable material at a minimum distance of 1m from SPARKULAR miniFALL and the sparks it generated. Make sure sparks shoot out from Sparkular miniFALL can NOT touch any objects.
  • After the show, please stop preheating or powering off and move the SPARKULAR miniFALL only after it cools down for more than 5 minutes.
  • The SPARKULAR miniFALL power supply cable (SPARKULAR miniFALL power supply EX-cable) maximum allowed cascade for SPARKULAR miniFALL is 12pcs, exceeded connecting may result in damage.
  • For better heat dissipation, block the air intake and air outlet is prohibited.
  • Cover of nozzle of SPARKULAR miniFALL is prohibited.

Sparkular miniFALL Model No.BT14

| Parameter
Size| 150×160×240mm
Hopper capacity| 280g
Material Consumption| 15g/min
Weight| 3kg
Input| 220 -240VAC, 50/60Hz
Working Power| 130w
Working Temperature| -10 °C ~ 50 °C
Casing| Anti-flame ABS
Fall Length| 3-4m (large), 2-3m (medium)
Interface| Double DMX input interfaces, double AC power interfaces

Feature

  • D-Quiet technology, no noisy
  • Ultra-light weight
  • Low power consumption

Operation Panel

LCD information display area, showing operate menu and working status of machine.

Light-emitting diode display area

  • READY : After turning on machine, it will automatically preheat around 6 minutes, when the “READY” green light turns from flashing into long on, indicates that the machine is ready to work. When it flashes slowly, it indicates some error.
  • DMX : Flashing shows that DMX signal is connected, otherwise is without signal.
  • FAULT : When any malfunction , the light turns on.
  • HEAT : When the machine is heating, signal light turns on.

Bottom Indication Light:

  • Quick Flashing: Preheating

  • Long on: Finish preheating and ready to work

  • Slow Flashing: Error warning

  • MENU: Short press to switch interface, press for 3 seconds can switch to the advanced setup interface.

  • – : Parameters down

  • + : Parameters up

  • ENTER: Confirm and save parameters.

Radiofrequency identification area:

Composite Ti with RFID card, swiping cards used to identify parameters and types of granules. Please note that granules RFID card can increase the single machine specific working time. The card is disposable, can only use once.

Interface

Main Interface:

  • First line: Display DMX address is “1”.
  • Second line: Display the present inner core temperature and the temperature progress bar, displays the remaining time is 7 minutes and 24 seconds.

Error informational display table

Error Information Explanation
E0 System IC System error.
E2 Temp. Sensor The temperature sensor was damaged.
E3 P Temp. Over Machine stops working due to the chassis temperature is too

high
E4 Time Remain| Insufficient granules or remaining time, please swiping RFID card.
E5 K Temp. Over| Machine stops working due to the inner core temperature is too high
E6 Heat Fail| Heating failed.

Setting interface:

Press “MENU” to enter the Setting interface, press the “MENU” button to enter different options until you return to the main interface.

Options Range Instructions
Set DMX Address 1-512 Set the DMX address.
Wireless Control ON/OFF Wireless function switch. you can match code When

shows “ON”
Manual Fountain| ON/OFF| Manual fountain switch , for testing purposes only.

Advanced menu:

Press “MENU” 3 seconds to enter the advanced setup interface, press MENU key to enter different options, wait 3 seconds to return to the main interface.

Options Range Explanation
Set Temperature 500-620 Setup inner Core temperature. Please don’t change

default value without engineer’s suggestion from SHOWVEN.
Auto Heat| ON/OFF| Auto preheat function switch after turning on machine
Density| 70-100| Adjust the sparks density. Please don’t change default value without engineer’s suggestion from SHOWVEN.
Mode Selection| Factory Mode/ User Mode| Factory Mode is factory debugging mode, User Mode is using mode
DMX Channel Mode| 2 DMX Channel/ 4 DMX Channel| 2 DMX Channel is standard mode, 4 DMX Channel is special mode.
Default Parameter| | Press “ENTER” to restore all parameters to the factory settings.
Standby Switch| On/Off| When it’s on, the machine can only generate spark when pre-heating finish.

Cable DMX mode:

When using the DMX controller, the system takes 2 channels

The First channel Functions
0-15 Fountain OFF
16-255 Fountain ON
The second channel Functions
60-80 Clear Material
20-40 Emergency Stop
0-10 Pre-heat OFF (Disable in Auto-heat)
240-255 Pre-heat ON (Disable in Auto-heat)

Please don’t set the same DMX address when controlling with host controller ZK6200/ZK6300. Host controller can reduce the performance risk by monitor the working status of each machine.

Warranty Instructions

  • Sincere thanks for your choosing our products, you will receive quality service from us.
  • The product warranty period is one year. If there is any quality problems, we can exchange a brand new same model machine to you within seven days after receive the product.
  • We will offer free of charge maintenance service for machines which with hardware malfunction (except for the instrument damage caused by human factors) in warranty period. Please don’t repair machine without factory permission.

NOTE: Below situations NOT included in warranty service:

  • Damage caused by improper transportation, usage, management, and maintenance, or damage caused by human factors.
  • Disassemble, modified or maintenance products without Showven’s permission.
  • Damage caused by external reasons (lightning strike, power supply etc).
  • Damage caused by improper installation or use;

For product damage not included in warranty range, we can provide paid service.
NOTE: Invoice and warranty card are necessary when asking for service from SHOWVEN.

Warranty Card

Showven Technologies Co., Ltd.
Add : Building B1, Changsha E-center No.18, Xiangtai Road, Economic & Technology
Development Zone, Hunan, China.
Tel: +86-731-83833068
Fax: +86-731-83833069
Web : www.showven.com
E-mail: [email protected]

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Showven User Manuals

Related Manuals