Product Usage Instructions:
Operation Instructions:
APPEARANCE AND KEY FUNCTIONS
1. Probe cover 2. Night light 3. On/Memory button 4.
Manufacturing label 5. Battery cover 6. Probe lens 7. Scan button
8. Bluetooth indicator
Introduction:
Thank you for choosing TD-1261 Forehead thermometer. This
innovative medical device relies on advanced infrared (IR)
technology to measure temperature instantly and accurately through
the surface of the skin over the forehead. TD-1261 Forehead
thermometer is an elegantly designed infrared thermometer meant for
your family.
Intended Use:
TD-1261 thermometer is an infrared thermometer intended for the
measurement of human body temperature in people of all ages without
contact to the body and may be used by medical professionals or by
consumers in a home environment.
How Does It Work:
The thermometer measures the infrared heat generated by the
surface of the skin over the temporal artery. The thermometer then
converts it into a temperature value shown on LCD.
Important Safety Instructions:
READ THIS BEFORE USING AND KEEP THESE INSTRUCTIONS
-
Close supervision is necessary when the thermometer is used by,
on, or near children, handicapped persons or invalids. -
Read this manual thoroughly and carefully prior to using. Use
the thermometer only for the intended use described in this
manual. -
Do not use the thermometer if it is not working properly, or if
it has suffered any damage. -
Do not use accessories which are not supplied or recommended by
the manufacturer. -
Proper maintenance is essential to the longevity of your
device. If you are concerned about your accuracy of measurement,
please contact local customer service. -
This device is a precision optical thermometer. Handle
carefully and do not drop. -
This device is a non-sterile device. Do not use harsh methods
to sterilize the device.
Cautions and Warnings:
LCD SCREEN
- Temperature scanning in progress
- Temperature display
- Memory mode
- Record numbers
- Low battery indicator
- Temperature unit
- Communication symbol
- Skin/Surface temperature indicator
Using the Device:
-
Step 1: Turn on the thermometer by pressing
and releasing the On / Memory button. The thermometer displays the
last measurement. -
Step 2: Put the probe perpendicularly to the
forehead and press and hold the Scan button. Ensure the probe is
perpendicular to the forehead. -
Step 3: Read the result by releasing the
button. A temperature value will be displayed with beeps.
Note:
-
Please ensure the forehead is clean before taking a
measurement. -
If the probe is placed at an angle on the skin/surface scan,
the reading will be affected by surrounding temperature. -
You can perform a forehead scan from 3 cm away.
-
To turn off the thermometer, press the On / Memory button twice
or leave it for 3 minutes after a temperature measurement for
automatic turn-off. -
If you need to take another reading, wait for flashing before
taking another measurement.
Frequently Asked Questions (FAQ):
Q: How do I clean the thermometer?
A: Clean the thermometer with a soft cloth dampened with water
and mild detergent. Do not immerse it in water or use abrasive
cleaners.
Q: Can this thermometer be used to measure room
temperature?
A: No, this thermometer is designed specifically for measuring
human body temperature and should not be used for measuring room
temperature.
Part no.
311-1261500-XXX
Product name
/CLEVER/1261E/EN/Qardio/
Spec
L353*W250mm/
100P/ / /3 (
2+
Designer Color
JF
K100
K75
L88.25*W125mm
Forehead Thermometer 311-1261500-XXX Version 2.0 2020/04
TD-1261
Operation Instructions
APPEARANCE AND KEY FUNCTIONS
1. Probe cover 2. Night light 3. On/Memory button 4. Manufacturing label 5. Battery cover 6. Probe lens 7. Scan button 8. Bluetooth indicator
6 1 2
3 5 4
7 8
INTRODUCTION
Thank you for choosing TD-1261 Forehead thermometer. This innovative medical
device relies on advanced infrared (IR) technology to measure temperature
instantly and accurately through the surface of the skin over the forehead.
TD-1261 Forehead thermometer is an elegantly designed infrared thermometer
meant for your family.
INTENDED USE
TD-1261 thermometer is an infrared thermometer intended for the measurement of
human body temperature in people of all ages without contact to the body and
may be used by medical professionals or by consumers in a home environment.
HOW DOES IT WORK
The thermometer measures the infrared heat generated by the surface of the
skin over the temporal artery. The thermometer then converts it into a
temperature value shown on LCD.
IMPORTANT SAFETY INSTRUCTIONS
READ THIS BEFORE USING AND KEEP THESE INSTRUCTIONS
The following basic safety precautions should always be taken.
1. Close supervision is necessary when the thermometer is used by, on, or
near children, handicapped persons or invalids.
2. Read this manual thoroughly and carefully prior to using. Use the
thermometer only for the intended use described in this manual.
3. Do not use the thermometer if it is not working properly, or if it has
suffered any damage. 4. Do not use accessories which are not supplied or
recommended by the manufacturer. 5. Proper maintenance is essential to the
longevity of your device. If you are concerned about your
accuracy of measurement, please contact the local customer service or place of
purchase for help. 6. This device is a precision optical thermometer. Handle
carefully and do not drop. Do not use if
thermometer has suffered damage. 7. This device is a non-sterile device. Do
not use ethylene oxide gas, heat, autoclave, or any other
harsh methods to sterilize the device.
CAUTIONS AND WARNINGS
As with any thermometer, proper technique is crucial to getting accurate
temperature readings. Please read this manual thoroughly and carefully before
using. Always operate the thermometer in an operating temperature range 50°F
to 104°F (10°C to 40°C), and relative humidity less than 95%. Always store the
thermometer in a cool and dry place: temperatures between -4°F to 140°F (-20°C
to 60°C); relative humidity less than 95%. Avoid direct sunlight. Avoid
dropping the thermometer. Do not disassemble the thermometer. Basic safety
precautions should always be observed, especially when the thermometer is used
on or near children and disabled persons. This thermometer is not intended to
be a substitution for a consultation with your physician. The forehead scan
temperature serves as a reference only. It cannot be a judgment on fever. Do
not use if thermometer has suffered damage. Do not place it on the fireplace,
or near heating/cooling sources. Do not touch the lens.
LCD SCREEN
21
8
7
1. Temperature scanning in progress 2. Temperature display 3. Memory mode 4. Record numbers 5. Low battery indicator
6. Temperature unit 7. Communication symbol 8. Skin/Surface temperature
indicator
USING THE DEVICE
3
4
5
6
Step 1 Turn on the thermometer. Press and release the On / Memory button. The thermometer displays the last measurement.
Step 2 Put the probe perpendicularly to the forehead. Press and hold the Scan button. Make sure the probe is perpendicular to the forehead, not at an angle.
Step 3 Read the result. Release the button and read the result.” ” is shown together with a temperature value and beeps.
NOTE
Please make sure that the forehead is clean before taking a measurement. If
the probe is placed at an angle on the skin/surface scan, the reading will be
affected by surrounding temperature. You can perform a forehead scan from 3 cm
away. Turn off the thermometer by pressing On / Memory button twice. Or leave
for 3 minutes after a temperature measurement, the thermometer will
automatically turn off. If you need to take another reading, wait ” ” flashing
before taking another measurement.
HOW TO CHANGE THE TEMPERATURE UNIT
On the thermometer
Step 1
Keep pressing the scan button.
Step 2
Insert battery while scan button is presed.
Step 3
Release the scan button after you see C (°C) or F (°F) on screen.
Step 4 Reattach the battey cover.
On the app You can also change the temperature unit you will see on the app screen.
Open settings in the Qardio App and select `set up your thermometer’.
Select display unit Celsius Fahrenheit
Save
Then simply select the display unit and save.
You will then see °C or °F on the app screen as per your selection.
Temperature 36.5 °C
2020/11/2, 3:00 PM
Temperature 97.7 °F
2020/11/2, 3:00 PM
RESULT INDICATORS
Message
What it means
Temperature measurement outside the displayed temperature range, skin/surface
scan temperature ranging from 71.6°F~111.2°F (22°C to 44°C), is shown on the
display with red LED.
Hi-temperature 111.3°F (44.1°C) Lo-temperature 71.5°F (21.9°C)
RECALLING THE MEMORY
Your thermometer stores 10 recent readings in the memory.
Step 1 Be sure the thermo-meter is OFF before recalling this memory.
Step 2 Press the On / Memory button to turn on the thermometer.
Step 3 Press the On / Memory button for 3 seconds to enter memory mode. Each
time you press the On / Memory button, a result will be displayed in the order
of dates (latest result shown first), together with ” ” and number ( from 1 to
10 ).
When the memory is full, the new result will overwrite the oldest one. When
you find the result on the display, press On / Memory button again to return
to the first record.
Step 4 Exit the memory. Press the Scan button and LCD will show latest results
with flashing ” ” . Then press On/Memory button again, and then the LCD will
show ” OFF ” to exit memory.
TRANSMITTING DATA VIA BLUETOOTH
You may transmit your temperature data from the meter to your device via
Bluetooth. Please contact your local customer service or place of purchase for
assistance. Please note that you must complete the pairing between the meter
and Bluetooth receiver before transmitting data.
Pairing with your mobile device 1. Turn on the Bluetooth function on your
mobile device. 2. Turn on the meter, press and hold the On and Scan buttons
simultaneously until “CLr” appears on
the display. Your meter is now in pairing mode. 3. Follow the instructions on
your app to pair the meter with your mobile device. (Ex. Search for the
meter and then add it into app.) 4. After you successfully pair up the meter
with your mobile device, the Bluetooth function of meter
will be activated automatically after each measurement. The meter is ready for
transmitting the data to your app.
Bluetooth Indicator
Bluetooth Indicator on the Thermometer
Bluetooth Indicator Flashing indicator
Status
The Bluetooth function is on and waiting for connection.
Solid indicator
The Bluetooth connection is established.
WARNING
· While the meter is in transmission mode, it will be unable to perform a
test. · Make sure your device has the Bluetooth function turned on and the
meter is within
the receiving range before transmitting the data.
REPLACING THE BATTERY
The thermometer comes with two 1.5 V AAA alkaline batteries. Replace it when ” ” appears. Please follow the steps to replace new batteries.
Step 1 Remove the battery cover.
Step 2 Place the new batteries in the battery compartment and press it in until the batteries are secured.
Step 3 Reattach the battery cover.
NOTE
Although the thermometer works when ” ” appears, we still recommend that you
change the batteries to obtain an accurate result. Remove the batteries if
stored for a long period of time. The batteries should be kept out of
children. If they are swallowed, promptly see a doctor for help. Properly
dispose of the batteries according to your local environmental regulations.
ABOUT NORMAL BODY TEMPERATURE & FEVER
Body temperature can vary from one individual/person to next. It also varies
by location on the body and time of day. Below shows the statistical normal
ranges from different sites. Please keep in mind that temperatures measured
from different sites, even at the same time, should not be directly compared.
Fever indicates that the body temperature is higher than normal. This symptom
may be caused by infection, overdressing or immunization. Some people may not
experience fever even when they are ill. These include, but are not limited
to, infants younger than 3 months old, persons with compromised immune
systems, persons taking antibiotics, steroids or antipyretics aspirin /
ibuprofen / acetaminophen, or persons with certain chronic illnesses. Please
consult your physician when you feel ill even if you do not have a fever.
Table *1 Body Site Normal Temperature Range
Body Site Oral Axillary (underarm) Rectal
Normal Temperature Range 95.9°F – 99.5°F (35.5°C – 37.5°C) 94.5°F – 99.1°F (34.7°C – 37.3°C) 97.9°F – 100.4°F (36.6°C – 38.0°C)
Ear
96.4°F – 100.4°F (35.8°C – 38.0°C)
*1. Chamberlain, J. M. Terndrup, T. E., New Light on Thermometer Readings,Contemporary Pediatrics, March 1994.
CARE & CLEANING
Keep the probe lens clean, as grease build up may affect the measurement. The
probe is not waterproof. Please wipe with a clean and dry cotton swab to clean
the probe on the inside. The body of the thermometer is not water-resistant.
Never put the thermometer under a running tap or submerge it into water. Use a
soft and dry cloth to clean it. Do not use abrasive cleaners. Store the
thermometer in a cool and dry location. Free from dust and away from direct
sunlight.
TROUBLESHOOTING
The table below shows problems you may encounter. All error messages below
would be shown together with red backlight. Please follow “what to do” to
resolve problems. If the problem still exists, please call your local dealer
for help.
Message
What it means
Appear when environmental temperature is below or above system operation
range.
What to do
Put the thermometer under operating temperature range of 50°F to 104°F (10°C
to 40°C)
Problem with the thermometer.
Review the instructions and re-start the measurement procedure. If the problem persists, contact your dealer.
Battery is low and ” “appears Please replace new batteries as
on LCD.
soon as possible.
Appears when the batteries can’t provide enough power for a test.
Please replace new batteries immediately.
SPECIFICATIONS
Model no.: TD-1261 Dimension & Weight: 162.2mm x 32.4mm x 38mm, 79g (without batteries) Battery: 2 x 1.5 V alkaline batteries External output: Bluetooth Displayed temperature range: 71.6°F~111.2°F (22°C to 44°C) Display resolution: 0.1°F / 0.1°C Accuracy: Meet the accuracy requirement specified in ASTM E1965-98
TEMPERATURE RANGE 96.8°F to 102.2°F (36.0°C to 39.0°C) <96.8°F (36.0°C)
102.2°F (>39.0°C)
ACCURACY ±0.4°F (±0.2°C)
±0.5°F (±0.3°C)
Temperature unit: °F/°C Operating temperature range: 50°F to 104°F (10°C to 40°C ) Operating humidity: 95% RH or less Storage temperature range: -4°F to 140°F (-20°C to 60°C) Storage humidity: 95% RH or less Memory capacity: 10 measurements Expected service life: 3 years IP classification: IP22
REFERENCE STANDARDS
Device Standard: Device Corresponds to the requirements of the standard for
infrared thermometers ASTM E1965-98 EN 12470-5 EN 60601-1-2:2007/AC:2010 EN
60601-1-4:1996 EN 60601-1-6:2010
Electromagnetic Compatibility:
Device fulfills the stipulations of the standard EN 60601-1-2
FCC STATEMENT
FEDERAL COMMUNICATIONS COMMISION (FCC) STATEMENT
15.21
responsible for compliance could void the user’s authority to operate the
equipment. 15.105(b)
This equipment has been tested and found to comply with the limits for a Class
B digital device, pursuant to part 15 of the FCC rules. These limits are
designed to provide reasonable protection against harmful interference in a
residential installation. This equipment generates, uses and can radiate radio
frequency energy and, if not installed and used in accordance with the
instructions, may cause harmful interference to radio communications. However,
there is no guarantee that interference will not occur in a particular
installation. If this equipment does cause harmful interference to radio or
television reception, which can be determined by turning the equipment off and
on, the user is encouraged to try to correct the interference by one or more
of the following measures:
· Reorient or relocate the receiving antenna. · Increase the separation
between the equipment and receiver. · Connect the equipment into an outlet on
a circuit different from that to which the receiver is
connected.
· Consult the dealer or an experienced radio/TV technician for help.
This device complies with Part 15 of the FCC Rules. Operation is subject to
the following two conditions: 1) This device may not cause harmful
interference and 2) This device must accept any interference received,
including interference that may cause
undesired operation of the device.
FCC RF Radiation Exposure Statement: 1. This Transmitter must not be co-
located or operating in conjunction with any other antenna or
transmitter. 2. When used with an accessory that contains metal may not ensure
compliance with FCC RF
exposure guidelines.
Distributed by: Qardio, Inc. 345 California Street Suite 600 & 700 San
Francisco, CA 94104 support@getqardio.com
Read instructions before use.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>