ELNUR PH-075 Plus Smart Panel Heater PH Instruction Manual
- June 17, 2024
- ELNUR
Table of Contents
ELNUR PH-075 Plus Smart Panel Heater PH Instruction Manual
WARNING Please read these instructions before installing or using this appliance for the first time.
- The warranty of the heater will not cover any damage caused by non-observance of any of these instructions.
- The instructions should be retained for future reference. This guide must be kept and given to any new owner.
- This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning the use of the appliance in a safe way and understand the hazards involved. Children must not play with the appliance. Cleaning and user maintenance must not be made by children without supervision.
- Children aged from 3 years and less than 8 years shall only switch on/off the appliance provided that it has been placed or installed in its intended normal operating position and they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved. Children aged from 3 years and less than 8 years shall not plug in, regulate and clean the appliance or perform user maintenance.
- Children of less than 3 years should be kept away unless continuously supervised.
- Please check that the voltage in the rating label fits the power supply.
- The use of panel heaters is forbidden in any area where there is a presence of gases, explosives or inflammable objects.
- Do not use this heater to dry clothes. Do not cover this heater or put objects in contact with it.
- Neither the connecting cable nor any other object must come into contact with the hot unit.
- Do not cover this heater at any time.
- The air outlet at the top of the thermal radiator and the air inlet at the bottom are provided to ensure the most efficient operation of the appliance. They also protect the heater from overheating; therefore, it is essential that at no time are they covered.
- This heater should be switched off at the isolating switch before any repair work is carried out.
- The installation must be carried out in accordance with the current electrical regulations.
- Should the heater be moved and reinstalled it is essential that the work is carried out by a fully qualified technician.
- The heater should not be installed just below an electrical socket.
- The appliance must be installed in such a way that it is impossible for anyone using a bath or shower, to touch the controls.
- The heater is fitted with a flexible cable size 3 x 1.00 mm² for electrical connection. It may be used to connect the heater to the fixed wiring of the premised through a suitable connection box positioned adjacent to the heater.
- This appliance must be connected to the supply by fixed wiring. The supply circuit to the heater must incorporate a double pole isolating switch having a contact separation of at least 3 mm.
- If the flexible power cable for this unit is damaged, it may only be replaced by a repair workshop recognised by the manufacturer, as special tools are necessary.
- This appliance must be earthed.
- All models are supplied with an electrical interrupt cut-out. This will switch off the heater if, for any reason, it overheats. Should the cut-out operate, turn the heater off and remove the cause for the overheating. The cut-out will be reset automatically.
- Please, if included, complete the enclosed warranty card and return it to the manufacturer to enable registration to take place.
- The presence of air particles of smoke, dust and other pollutants could, in time, discolour the walls and surfaces around the heater.
- CAUTION — Some parts of this product can become very hot and cause burns. Particular attention must be given when children and vulnerable people are present.
INSTALLATION INSTRUCTIONS
- Open the package and check that it is the correct model and it is in good condition.
- To obtain optimum performances it is necessary to maintain a minimum clearance of 50 cm between the panel heater and any inflammable material as furniture, curtains etc.
- The studs and screws to attach the supports are in the accessories bag.
- Fix the two square brackets to the back of the heater by using the two smalls screws. ( **see Fig.1)
**
-
Position and fix the top bracket at the correct distance from the floor ( see Fig.2 ) and hang the unit on the hooks of the top bracket
-
Mark the fixing points on the wall using a pencil. Use the heater fixing holes as a template and mark the wall through the two fixing holes in the square brackets. Fix the heater to the wall.
USING THE PANEL HEATER
DIGITAL CONTROL WITH DAILY AND WEEKLY PROGRAMMING
-
SUN indicator
-
SUN key: Press once to see the SUN temperature value. Pressor-keys to modify the value
-
MOON key:
Press once to see the MOON temperature value. Press + or -keys to modify the value. -
MOON indicator
-
Press this key for more than two seconds to set the time or day of the week
-
Digital DISPLAY:
It shows the time, temperature and other messages. – -
Heating indicator:
This small dat will be lit when the heater is consuming energy. -
Frost protection key:
If the display shows the time the heater is in frost protection mode. Press this key to shift from frost protection mode to standard mode and vice versa -
Key “+”:
It increases the values. -
Key “.”:
it decreases the values. -
PRG key:
Allows you to create check or modify programs. Move forward with or-keys and allocate the SUN, MOON, or temperature to any of the 48 intervals of 30 minutes of the day by means of the relevant key
Main switch:
All models are equipped with one switch on the right surface allowing the
panel heater disconnection.
Ph Plus panel heaters have built in an electronic thermostat with a sensibility of 0.1 ºC. It is possible to set temperatures with an accuracy of 0.5ºC.
The daily or weekly programmer (selectable) allows you to allocate three different temperature levels to any of the 48 intervals of 30 minutes of the day.
WITCHING ON THE PANEL HEATER
Once the heater is connected to a main supply, switch on the heater by setting
the switch marked I-O positioned at the rigth side of the panel heater to “I”.
The off position is marked “O”.
SETTING THE TIME
Press the key more than two seconds. The display will show the time
intermittently. Set the hours by pressing + and – keys and press the . Set the
minutes the same way. Press once more the key to store the time. If at any
time it is necessary to set the time press the key and repeat the above steps.
FROST PROTECTION MODE
With this mode on, if the room temperature drops below 3ºC the heater will
connect itself automatically. If the display shows the time the panel heater
is in frost protection mode. Press the **key to shift from frost protection
mode (time is shown in the display) to standard mode (temperature is shown in
the display) and vice versa.
PROGRAMMING THE PANEL HEATER
The panel heater operates in programming mode maintaining the SUN, MOON or
**temperatures as per the introduced program. If the display shows the time,
the panel heater is in frost protection mode.
SUN, MOON AND TEMPERATURES
The electronic programmer is able to handle three temperature levels during
the 24h of the day. Press the key to set the SUN temperature. The display
will show the SUN temperature value blinking. Set the SUN temperature value by
means of the + o – keys and press the key to store the value. If the display
shows the time the heater is in frost protection mode. Press the key to
shift from frost protection mode (time is shown in the display) to standard
mode (temperature is shown in the display) and vice versa
Repeat the above steps with the key to set the MOON temperature.
The temperature level is 3ºC and it is a fix value. This temperature level
can be used as off selection when setting the temperatures during curtain
times of the day.
SUN, MOON, or ****temperatures can be allocated to any of the 48 intervals of
30 minutes of the day.
DAILY PROGRAMMES
It is basic to visualize the day split into 48 intervals of 30 minutes each;
SUN, MOON, or ****temperatures can be allocated to any of them.
The default settings include daily mode so that the heater will repeat the program every day. If different programmes are required along a week, please see the next step WEEKLY PROGRAMMES. To check a programme or to make a new one, follow these steps:
Press the PRG key and the display will show 00:00 intermittently. Press one of the three keys to allocate SUN, MOON or OFF (frost protection) from 00:00h to 00:30h. If SUN or MOON temperatures are selected the relevant luminous indicator will be lit. If OFF temperature ****is selected both luminous indicators will be off.
Press the + key to go to the next interval. The display will show 00:30
intermittently and, again, press one of the three keys to allocate SUN, MOON
or OFF (frost protection) from 00:30h to 01:00h or press + key directly if the
existing temperature level is ok.
Repeat these steps allocating the desired temperatures levels over the 24
hours of the day. Press the – key at any time to modify a previous period. By
reaching the 23:30 in the display and pressing + key, the controller will
store the program and will return to the previous mode. At any time PRG key
can be used also to store the program and return the previous mode.
EXAMPLE
Let’s see an example of how to introduce a program with the above distribution
of temperatures.
OFF from 24:00h to 7:30h in the morning. The heater will be on only if the
temperature drops to 3ºC.
SUN temperature from 7:30h to 9:00h.
MOON temperature from 9:00h to 13:00h.
SUN temperature from 13:00h to 15:00h.
MOON temperature from 15:00h to 19:30h.
SUN temperature from 19:30h to 24:00h
WEEKLY PROGRAMMES
It is possible to allocate different programs to different days of the week.
To do this, the controller has to be upgrade from 24hr mode (factory default)
to 24hr/7days mode as follows:
Switch off the panel heater by turning off the main switch at the right side
of the heater, the display will be Off. Press the key and at the same time
turn on the main switch maintaining the key at least five seconds. The display
will show P-SE which means that weekly mode has been set.
SETTING THE DAY: Press the key more than two seconds and the display will show
the number of the day. Set the correct number, if required, by pressing + or –
keys. Press the key and the display will show now the time. Press again the
key and new values will be stored.
To check a programme or to make a new one press PRG key: The display will
show dia1. Press again PRG key and the display will show 00:00
intermittently. Follow now the steps from DAILY PROGRAMMES section until the
display shows again dia1. Repeat this process with the 7 days of the week.
When the display shows dia7 the weekly program will be stored by pressing +
key.
If the display shows dia1 then, pressing + key more than three seconds will
copy the day 1 program to day 2 and so on.
It is possible to allocate any of the three temperature levels to all the
intervals of any day maintaining the relevant key until an audible signal is
heard
To turn back a controller from 24hr/7days to a single 24hr press PRG key more
than six seconds. This will restore the factory default settings.
KEYBOARD LOCK
Press the key more than six seconds and the keyboard will be locked. The
display will show and the controller will keep on working internally. To
unlock the keyboard, press again the key more than six seconds.
SUN MANUAL OVERRIDE
Maintain the SUN Key pressed for 4 seconds to set the Sun Manual Override. The
heater will maintain the sun temperature set
point and will ignore the pre-set program until the next change in programming
temperature level.
Both luminous indicators SUN and MOON will be lit. This function could be
useful when SUN temperature is required and we do not want to modify the
program.
By pressing the SUN key for 4 seconds with Sun Manual Override activated, the
function will be removed and the heater will follow the programme again.
ADVANCED FUNCTION
OPEN WINDOW DETECTION
With open window detection activated, the heating element will be disconnected
automatically when a sharp decrease in temperature in the room is detected
avoiding energy wastage. After this period of time, the panel heater returns
to the prior operation mode. When Open Window Detection is working, the word
Open will be displayed alternating with the status of the current mode.
Note: To activate the open window detection please refer to ADVANCED FUNCTION
ACTIVATION section.
ADAPTIVE START CONTROL
PH Plus electronic control analyses the heating requirements of the room where
the panel heater is installed using this information to turn on the heating
element in advance in order to reach the set point temperature at the desired
time. When Adaptive Start Control is working, the word AdAP will be displayed
alternating with the status of the current mode.
Note: To activate the adaptive start control please refer to ADVANCED FUNCTION
ACTIVATION section.
ADVANCED FUNCTION ACTIVATION
Advanced functions Open Windows Detection and Adaptive Start Control are
disabled by default. To enable / disable these functions, the following steps
must be followed:
Switch off the panel heater by turning off the main switch at the right side
of the heater, the display will be Off. Press the key and at the same time
turn on the main switch maintaining the key at least five seconds.
The display will show OPEn alternating with the status of the function (On or
OFF). Use the navigation keys + or – to enable / disable Open Windows
Detection function. Confirm the new value for the function by pressing the PRG
key. The next function (AdAP) is shown alternating with its status (On or
OFF). Use the navigation keys + or – to enable / disable Adaptive Start
Control function. Confirm the new value for the function by pressing the
PRG key.
UNIT RESET
The panel heater reset establishes the factory configuration of the heater removing the programming, establishing the daily programming and disabling the advanced functions. To reset the unit, hold the PRG key for 4 seconds, the display will show InIC to indicate the heater has been reset.
CLEANING AND MAINTENANCE
The panel heaters do not precise any special maintenance providing thermal
comfort during large periods. Clean dust with a dry, soft cloth only when the
unit is disconnected and cold. Do not use solvents or abrasive products for
cleaning. This panel heater has been manufactured under an assured quality
system using environment friendly processes. Please take the panel heaters to
a clean point once their useful life is finished, in order to recycle their
materials in the right way
TROUBLESHOOTING
The panel heater radiator does not heat.| Check the heater or the air inlets
are not covered.If the display shows the time, press the key to switch on the
heater. Check that the DAY or NIGHT temperatures are right.
---|---
The room does not reach the requiredtemperature.| Check the selected
temperature is in accordance with the desiredtemperature. Maybe the room needs
more heating power.
DAY and NIGHT luminous indicators arelit at the same time| Sun Manual Override
has been configured.Hold the Sun key for 4 seconds to return to the
programming.
The display shows “Err1” or “Err2”| Contact the after sales service.
Only daily programmes| The controller is in single 24hr mode (factory
default). See WEEKLYPROGRAMMES section to switch to 24hr/7days mode.
The keyboard does not respond.| If the display shows| **** | , the
keyboard is locked. To unlock it, press
the key more than six seconds.
SPECIFICATIONS
M odels | PH-075 Plus | PH-125 Plus | PH-150 Plus | PH-200 Plus |
---|---|---|---|---|
Length (cm) | 41 | 56 | 63 | 78 |
Width (cm) | 8 | 8 | 8 | 8 |
Height (cm) | 41 | 41 | 41 | 41 |
Weight (kg) | 3.5 | 4 | 4.5 | 5.5 |
Voltage | 230 – 240 V ~ | |||
Isolation | Class I | |||
Power (W) | 700 – 750 | 1150 – 1250 | 1400 – 1500 | 1850 – 2000 |
MAIN COMPONENTS LIST
Main PCB | ref. 30100084 | 750 W Heating Element | ref. 40491755 |
---|---|---|---|
Keyboard | ref. 40491702 | 1250 W Heating Element | ref. 40491757 |
85ºC thermal limiter | ref. 30100040 | 1500 W Heating Element | ref. 40491759 |
Main Switch | ref. 46100530 | 2000 W Heating Element | ref. 40491761 |
WIRING
PRODUCT FICHE
MODEL(S): ELNUR GABARRON PH-075 Plus, PH-125 Plus, PH-150 Plus, PH-200 Plus
Item
| **Symbol| Value| ****Unit
---|---|---|---
PH-075 Plus| PH-125 Plus| PH-150 Plus| PH-200
Plus
Heat Output
Nominal heat output| Pnom| 0.75| 1.25| 1.5| 2.0| kW
Minimum heat output| Pmin| N.A.| N.A.| N.A.| N.A.| kW
Maximum continuous heatoutput| Pmax,c| 0.75| 1.25| 1.5| 2.0| kW
Auxiliary electricity consumption
At nominal heat output| elmax| 0.000| 0.000| 0.000| 0.000| kW
At minimum heat output| elmin| 0.000| 0.000| 0.000| 0.000| kW
In standby mode| elSB| <0.0005| <0.0005| <0.0005| <0.0005| kW
Item| Value. All models
---|---
Type of heat output / room temperature control
Electronic room temperature control plus week timer| Yes
Other control options**
Room temperature control, with open window detection| Yes
With distance control option| No
With adaptive start control| Yes
Contact details
| ELNUR, S.A.Travesía de Villa Esther, 11 28110 – Algete (Madrid), Spain
---|---
Commission Regulation (UE) 2015/1188 of 28 April 2015. Ecodesign requirements for electric fixed local space heater
The symbol on the product or in its packaging indicates that this product may not be treated as household waste. Instead it shall be handed over to the applicable collection point for the recycling of electrical and electronic equipment. By ensuring this product is disposed of correctly, you will help prevent potential negative consequences for the environment and human health, which could otherwise be caused by inappropriate waste handling of this product. For more detailed information about recycling of this product, please contact your local city office, your household waste disposal service or the shop where you purchased the product. These instructions are only valid in the EU member states.
WARNING: In order to avoid overheating do not cover the heater