ELNUR GABARRON 15703022 R1 Fan Coil FGS-DC Remote Controller Instructions

June 11, 2024
ELNUR GABARRON

15703022 R1 Fan Coil FGS-DC Remote Controller
Instructions
REMOTE CONTROLLER

FAN COIL FGS-DC

IMPORTANT INFORMATION

  • Please read these instructions carefully before installing or using this appliance for the first time.
  • The warranty will not cover any damage caused by non observance of any of these instructions.
  • This guide must be kept and given to any new user. Use this appliance only as described in this manual.
  • Curtain, door or similar objects will prevent the remote signal from being received by the fan coil unit.
  • Do not get the interior of remote controller wet. It is forbidden to expose it to direct sunlight or locate it in the place with high temp.
  • Effective transmitting distance of remote controller is 8 meters.
  • Do not drop or throw the remote control.
  • This a standard remote. Some models do not have all the functions described in this manual, reserves the right not to inform exclusively.

BUTTONS AND FUNCTIONS

ELNUR GABARRON 15703022 R1 Fan Coil FGS-DC Remote Controller - BUTTONS AND
FUNCTIONS

| Name|

Operating Description

---|---|---
1| **MODE| Once pressing, running mode will be selected in the following sequence: Auto, Cool, Dry, Fan, Heat.
**
2| **FAN SPEED| Fan Speed can be selected by pressing this button: Auto, Low, Medium and High.
**
3|


| Decrease the set temperature. Keeping pressed will decrease the temperature with 1ºC per 0.5s.
**** 4|


| Increase the set temperature. Keeping pressed will increase the temperature with 1ºC per 0.5s.
5| ON/OFF| Press this button to turn on / off the fan coil unit.
6| AIR DIRECTION| Press this button to change the angle of the air deflector.
7|


| Vertical Swing. Turn on / off automatic vertical swing of the air deflector.
8| **| Without use.
9|
CLOCK| Display the current time. (12:00 is displayed when resetting or electrifying for the first time). Press CLOCK for 5s, icon indicating hour will flash. Press it again, icon indicating minute will flash. and **are used to adjust the figure.
Setting or modification is effective only by pressing OK button to make confirmation.
10| **TIMER ON| For timer ON setting. Once pressing this button, the time will increase by 0.5 hour. Adjusting the figure to 0.00 will cancel timer ON setting.
**
11| **TIMER OFF| For timer OFF setting. Once pressing this button, the time will increase by 0.5 hour. Adjusting the figure to 0.00 will cancel timer OFF setting.
**
12| **RESET| (Inner located). Press this button with a needle of 1mm to cancel the current setting and reset remote controller.
**
13| **LOCK| (Inner located). Press this button with a needle of 1mm to lock or unlock the current setting.
14|
OK| Used to confirm the time setting and modification.
**
15| **COOL/HEAT| (Inner located). Press this button with a needle of 1mm to shift mode between COOL only and COOL&HEAT. During setting, back light will be lightened.
Factory default mode is COOL &HEAT.
16|
ECO**| Activate or turn off economic operation mode.

INDICATORS AND FUNCTIONS

ELNUR GABARRON 15703022 R1 Fan Coil FGS-DC Remote Controller - INDICATORS
AND FUNCTIONS

| Name|

Operating Description

---|---|---
1| **Temperature| Display the set temperature. Adjust temperature via and **No display in this area if the unit is on FAN mode.
2| Transmitting display| The icon will flash once when the signal is sent by remote controller.
3| ON/OFF| Icon is displayed when the remote controller is turned on, or vice versa.
4| **Running mode| Auto, Cool, Dry, Heat o Fan icon are displayed to indicate the current operating mode.
5|
Time| Display the current set time.
6|
Lock| The icon will be lightened or off when pressing LOCK.
**
7| Timer On / Off| In the state of timer ON, icon ON will be lightened, which is the same to the state of timer OFF.
8| Economic operation| This icon will be lightened or off when pressing ECO button.
9| Fan Speed| It is displayed the current fan speed.

BATTERIES REPLACEMENT

  1. Slide the front cover of the remote controller to access the batteries.
  2. Remove the old batteries.
  3. Insert two new batteries AAA 1,5V and make sure to place them in the right pole.
  4. Slide the front cover back.

Notes:

  1. Do not put the used or different batteries into the remote controller, otherwise remote controller will fail to send signal.
  2. Please remove the batteries before long period unused, otherwise the remote controller may be damaged.
  3. If no receiving sound is heard from indoor unit or on remote controller does not flash, please replace the batteries.
  4. The batteries mut be removed from the remote control before if is disposed. Batteries must be disposed of safely.

OPERATING MODES

Auto Mode
Press MODE button to select the Auto operating mode:
– Adjust the set point temperature by using and **.
– Press ON/OFF button to turn on / off the fan coil unit.
– The fan speed cannot be adjusted in this mode.
Cool / Heat / Fan Mode
Press MODE button to select the desired operating mode: Cool / Heat / Fan.
– Adjust the set point temperature by using and **
.
– Press ON/OFF button to turn on / off the fan coil unit.
– In Fan Mode, the set-point temperature cannot be adjusted. The economic operation cannot be selected in this mode.
Dry Mode
Press MODE button to select the Dry operating mode:
– Adjust the set point temperature by using and ****.
– Press ON/OFF button to turn on / off the fan coil unit.
– The fan speed cannot be adjusted in this mode.

TIMER ON / OFF

TIMER ON and TIMER OFF are used to turn on and turn off the unit at the set time respectively.
Timer ON operation
– Press TIMER ON, icons SET, HOUR and ON are lightened.
– Press TIMER ON again and adjust the time. The time will increase by 0.5 hour.
– When time setting is elapsed, the remote controller will send the ON signal to the fan coil unit.
Timer OFF operation
– Press TIMER OFF, icons SET, HOUR and ON are lightened.
– Press TIMER OFF again and adjust the time. The time will increase by 0.5 hour.
– When time setting is elapsed, the remote controller will send the OFF signal to the fan coil unit.
Timer On and Timer Off simultaneously
– Set TIME ON and OFF according to above procedures.
– Time ON will send the ON signal to the unit when the time setting has been elapsed.
– Time OFF operation will start after the unit has been turned ON. It will send the OFF signal to the unit when the time setting has been elapsed.
Modify and cancel timer
– Press corresponding button (Timer ON or Timer OFF) to readjust the time ON or Time OFF operation.
– Adjust the time figure to 0.0 to cancel the timer operation.

**** The symbol on the product or in its packaging indicates that this product may not be treated as household waste. Instead it shall be handed over to the applicable collection point for the recycling of electrical and electronic equipment. By ensuring this product is disposed of correctly, you will help prevent potential negative consequences for the environment and human health, which could otherwise be caused by inappropriate waste handling of this product. For more detailed information about recycling of this product, please contact your local city office, your household waste disposal service or the shop where you purchased the product. These instructions are only valid in the EU member states.

ELNUR S.A.
Travesía de Villa Esther, 11
28110 Algete – Madrid
Tfno. Atención al Cliente:
+34 91 628 1440
www.elnurgabarron.es
www.elnurgabarron.com
www.elnur.co.ukELNUR GABARRON 15703022 R1 Fan Coil
FGS-DC Remote Controller - icon 5

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

ELNUR GABARRON User Manuals

Related Manuals