ELNUR GABARRON IFF-2600 Long-Wave Slim Panel Infrared Heater User Manual

June 2, 2024
ELNUR GABARRON

ELNUR GABARRON IFF-2600 Long-Wave Slim Panel Infrared Heater User Manual

1.  IMPORTANT INFORMATION

  • The warranty of the heater will not cover any damage caused by non-observance of any of these
  • The instructions should be retained for future This guide must be kept and given to any new owner.
  • This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning the use of the appliance in a safe way and understand the hazards Children must not play with the appliance. Cleaning and user maintenance must not be made by children without supervision.
  • Children aged from 3 years and less than 8 years shall only switch on/off the appliance provided that it has been placed or installed in its intended normal operating position and they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards Children aged from 3 years and less than 8 years shall not plug in, regulate and clean the appliance or perform user maintenance.
  • Children of less than 3 years should be kept away unless continuously Please check that the voltage in the rating label fits the power supply.
  • Please check that the voltage in the rating label fits the power
  • The use of these heaters is forbidden in any area where there is a presence of gases, explosives or inflammable
  • Do not use this heater to dry
  • Do not put objects as clothes, fabrics or any combustible materials in contact with the
  • Neither the connecting cable nor any other object must come into contact with the
  • This heater should be switched off at the isolating switch before any repair work is carried
  • The installation must be carried out in accordance with the current electrical
  • The heater should not be installed just below an electrical socket-outlet or dripping
  • The heater is to be installed so that switches and other controls cannot be touched by a person in the bath or Never touch the heater with wet or humid hands or barefoot.
  • IFF heater is an IP65 rated appliance enabling it mounting outdoors. Anyway, the heater is not intended for installation in locations that are permanently wet or humid or exposed to rainfall or snowfall. It should be installed in a location where it is sheltered from the effects of
  • The supply circuit to the heater must incorporate a double pole isolating switch having a contact separation of at least 3
  • If the flexible power cable for this unit is damaged, it may only be replaced by a repair workshop recognised by the manufacturer, as special tools are
  • WARNING: This appliance must be
  • The presence of air particles of smoke, dust and other pollutants could, in time, discolour the walls and surfaces around the
  • Any improper use is Do not sit on the heater.
  • It is important to maintain a minimum distance of 80 cm between the heater and curtains, or any other combustible materials that will be affected by the radiated
  • Do not touch the fireguard or reflecting cover when the heater is in use; do not insert any objects into the fireguard to prevent high temperature
  • The infrared heater is designed to only work in a horizontal Never operate your appliance if it has fallen over.
  • This movable appliance is designed for use Although the heater may be used outdoors, the main plug must only be connected to the supply indoors.
  • Do not use the heater while Never leave the heater unattended while it is operated.
  • Do not let the cable hang over the edge of a table or counter or let it come into contact with any hot
  • Do not use extension This could overheat and cause fires.
  • The heater must be disconnected during installation and
  • Never rotate the heating part of the appliance during To change the tit angle of the heating part, we advise you to wait for 15 minutes after the appliance has been switched off.
  • Never dismantle the components of the heater or replace the components with the ones that do not meet the safety

WARNING: The surface of this heater can be hot. Parts of the heater may exceed 200ºC.
CAUTION: Some parts of this product can become very hot and cause burns. Particular attention must be given when children and vulnerable people are present.
WARNING: Ensure that the supply cables is well mounted and that it does not come in contact with thev reflector of the heater or that it does not trail into a heated area.
WARNING : IN ORDER TO AVOID OVERHEATING, DO NOT COVER THE HEATER.
The symbol on the product or in its packaging indicates that this product may not be treated as household waste. Instead, it shall be handed over to the applicable collection point for the recycling of electrical and electronic equipment. By ensuring this product is disposed of correctly, you will help prevent potential negative consequences for the environment and human health, which could otherwise be caused by inappropriate waste handling of this product. For more detailed information about recycling of this product, please contact your local city office, your household waste disposal service or the shop where you purchased the product.These instructions are only valid in the EU member states.

2.  INSTALLATION WARNINGS

The ideal mounting position for this IFF infrared heater i son the ceiling, directly above the area to be heated. If this is not possible, IFF can be mounted on a wall and angled downwards. In this situation, ensure the mounting height is in the range 2,1 to 2,7 meters and the table is within 2,5 meters from the wall. The minimum clearances are shown in the picture below:

For mounting heights more than 2,7 meters, we recommend the installation using chains or other external brackets to reduce the height of the heater to 2,3 – 2,5 meters. This will increase the effectiveness of your infrared panel heater IFF.
Electrical connections should not be located at the back of the heater. If the heater is to be mounted on a slight incline Surface, ensure the Electrical connection is located at the lowest point of the heater.

3.  INSTALLATION

Wall/ceiling installation brackets are provided with the heater which has been specifically designed to allow this product to be fitted to a wall or ceiling with adequate clearances at the back of the unit. Do not install the heater with any other bracket except those provided.

1 Sliding Brackets 2 units
2 Handle Screws 2 units
3 Expansion Screw 4 units
4 Bracket 4 units
5 Screws 8 units
6 Gasket 8 units
7 Nut 4 units

Before drilling ensure that there are no wires or water pipes in the area where the heater is to be installed.
IFF unit is supplied with a pair of standard mounting brackets. These adjustable brackets allow direct ceiling or wall mount, and come with preset angle options.
Step 1: Assembly the adjusting bracket to sliding bracket.

Step 2: Installation of sliding bracket and heater as arrow pointed.

Step 3: Fix adjusting bracket into the wall by expansion screws.

Step 4: Installation of two adjusting bracket, make sure lock brackets tight by screws.

4.- OPERATION

**** IFF unit can be turned on without the remote control using the push button, located on the right end of the heater.

REMOTE CONTROLLER OPERATION

** Infrared IFF-2600 is operated using the remote control supplied with the heater. Insert 2 x AAA Alkaline batteries into the remote control.
Note** : All IFF2600 units and their remote controls have the same frequency, so it is possible to control several IFF2600 units with just one remote control.

Timer Setting

Press Timer button (5) and use the Up and Down buttons (2) and (3) to select the number of hours the heater will be working.The heater will be working providing the selected heat level during these hours.When the time has finished, the heater will automatically disconnect the heating elements.

Inserting Batteries

Insert 2 AAA/ Alkaline type batteries into your remote control

  1. Flip the backside of your remote control and pull out battery Insert the batteries in accordance with the instructions and polarity of the batteries.
  2. Change the batteries in the same way described

Warning:

  1. Replace the old batteries with the same type Otherwise, your heater may not function well.
  2. Pull out the batteries in case of long terms of disuse to prevent leakage which may impair your remote
  3. Do not allow water or liquid to get into the remote

5.- CLEANING AND MAINTENANCE

Disconnect the heater for your safety before cleaning your applicance and make sure the heater is cool before continuing.
Clean and dust with a dry, soft cloth only when the unit is disconnected and cold. Do not use solvents or abrasive products for cleaning.
This thermal heater has been manufactured under an assured quality system using environment friendly processes.
Please take the heater to a clean point once their useful life is finished, in order to recycle their materials in the right way.

Warning:

When the appliance is not operated for a long period of time, cleaning or maintenance is conducted or when the location of the heater is changed, the heater should be turned OFF and unplugged from the electrical connection.

6.- THECNICAL DATA. ERP FICHE

Model IFF-2600
Power 2600 W
Power Levels 2 levels (2600 – 1300 W)
Voltage 220 – 240 V~
Weight 9,5 kg
Dimensions 151 x 16 x 4,5 cm
IP Code IP65
Remote Control Yes
Information Symbol
--- ---
Heat Output Type of heat output / room temperature control
Nominal heat output Pnom

Electronic control plus daily timer

| ****

Yes

Minimum heat output| Pmin| 1.3| kW
Maximum continuous heat output| Pmax,c| 2.3| kW| Other Control Options
Auxiliary electricity consumption| ****

With working time limitation

| ****

Yes

At nominal heat output| elmax| 0.000| kW
At minimum heat output| elmin| 0.000| kW| ****

With black bulb sensor

| ****

Yes

In standby mode| elSB| <0.0005| kW


Contact details

| ELNUR, S.A.

Travesía de Villa Esther, 11 28110 – Algete (Madrid), Spain

---|---

Commission Regulation (UE) 2015/1188 of 28 April 2015. Ecodesign requirements for electric radiant local space heater.

ELNUR S.A.

Travesía de Villa Esther, 11 28110 Algete – Madrid
Tfno. Atención al Cliente:

+34 91 628 1440 ****


Read More About This Manual & Download PDF:

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

ELNUR GABARRON User Manuals

Related Manuals