IMPORTANT INFORMATION
When using electrical appliances, basic precautions should always be followed to reduce the risk of fire, electric shock, and injury to persons, including the following:
- Keep combustible materials, such as furniture, pillows, bedding, papers, clothes, etc. and curtains at least a foot (30cm) from the front, sides and rear of the heater. It is essential that the indicated minimum clearances are maintained.
- CAUTION — Some parts of this product can become very hot and cause burns. Particular attention must be given where children and vulnerable people are present.
- This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning the use of the appliance in a safe way and understand the hazards involved. Children must not play with the appliance. Cleaning and user maintenance must not be made by children without supervision.
- Children aged from 3 years and less than 8 years shall only switch on/off the appliance provided that it has been placed or installed in its intended normal operating position and they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved. Children aged from 3 years and less than 8 years shall not plug in, regulate and clean the appliance or perform user maintenance.
- Children of less than 3 years should be kept away unless continuously supervised.
- Do not operate any heater after it malfunctions. Disconnect power at service panel and have heater inspected by a reputable electrician before reusing. To disconnect heater, turn controls to off, and turn off power to heater circuit at main disconnect panel.
- Do not insert or allow foreign objects to enter any ventilation or exhaust opening as this may cause an electric shock or fire or damage the heater.
- Do not use this heater to dry clothes. To prevent a possible fire, do not block air intakes or exhaust in any manner. Air inlets and outlets provide proper operation of the appliance and prevent its overheating. DO NOT cover air inlet and outlet grills.
- A heater has hot and arcing or sparking parts inside. Do not use in areas where gasoline, paint, or flammable vapors or liquids are used or stored. The use of these heaters is forbidden in any area where there is a presence of gases, explosives or inflammable objects. Never open a charged heater.
- SAVE THESE INSTRUCTIONS. This guide must be kept and given to any new user. Use this heater only as described in this manual. Any other use not recommended by the manufacturer may cause fire, electric shock, or injury to persons. The warranty of the heater will not cover any damage caused by non observance of any of these instructions.
- Do not use this heater outdoors.
WARNING: In order to avoid overheating do not cover the heater.
OPERATING INSTRUCTIONS
General information
CAUTION: DO NOT USE THIS HEATER TO DRY CLOTHES. Do not cover this heater at any time.
CONNECTION / DISCONNECTION
KEYBOARD :
- Keep pressed the button to access the advanced configuration. Press this button to go back in the different menus.
- Press the button to confirm values in the different menus.
- Press the key to increase the displayed value or to advance through the different options available.
- Press the key to decrease the displayed value or to move through the different options available.
ON/OFF
Once the heater is connected to a main supply you can turn the heater ON by
switching the main ON/OFF switch positioned at the rear right side of the
heater as shown above.
BACKLIGHT
Pressing any button, the display will illuminate with a soft white colour.
After certain time if no buttons are pressed the display backlight will turn
off.
Buttons only will respond when the backlight is on.
KEYBOARD LOCK
During any operation mode, it is possible to lock the keyboard by holding
and
simultaneously for 5 seconds. A pop-up window will confirm the keyboard lock.
To unlock the keyboard, press and
simultaneously for 5 seconds. A pop-up window will confirm the keyboard
unlock.
Commissioning
An easy installation wizard is programmed in Ecombi Solar electronic control. Follow the start wizard instructions when turning your Ecombi Solar on for the first time or after resetting it to the factory settings.
START WIZARD – INITIAL SETTINGS.
The Ecombi Solar electronic control will guide you through the commissioning of the unit. The steps to follow are:
-
a. Select language. Confirm the language in the storage heater electronic control.
-
b. Date & Time. Check and confirm that the default date & time in the unit is correct. If not, please change it.
-
c. Charging periods. 2 different charging periods can be set in Ecombi Solar. Set Charging Periods 1 & 2 according to your electricity low tariff hours.
By default, Ecombi Solar is set to an 8 hours charging period, from 00:00 to 08:00 hours. If this charging time matches your electricity low tariff hours, you do not need to make any changes in the unit configuration. Otherwise, you can change charging Periods 1 and 2 to match your electricity tariff.
If your electricity tariff is 14 hours off-peak, you must modify the charging configuration in the advance settings menu and select 14 hours nominal charging period. -
d. Temperature setting. This is the last step of the start wizard. Select and confirm the room set temperature of your choice.
With the help of the start wizard, you will set you Ecombi Solar storage heater for an autonomous operation. It will charge and store the heat during the charging hours set in c. Charging Periods and it will adjust the charge level and consumption according to the set temperature of your choice.
An incorrect time, charging periods or set temperatures configuration, might result in a high cost of the electricity bill.
Utilization of photovoltaic surplus
PREPARATORY STEPS
Before using the PV surplus utilization function of your Ecombi Solar storage heaters, please perform the following steps:
- a. Installation and setting of the control hub and power meters included in the Solar Box. Please follow the instructions included within.
- b. Download from your market app the Elnur Gabarron Wifi Control app, available for IOS & Android.
- c. Create your user account in the app if you still do not have one.
- d. Register the control hub included in the Solar Box using your user account. Then link also the power meters included in the Solar Box if you still have not.
- e. Link the Ecombi Solar storage heaters to the control hub using the app. (See point 4. Remote Operation using the G-Control Hub for more detail).
To set and activate the PV surplus utilization function it is necessary to install the Solar Box device (1 Solar box per installation).
The PV surplus utilization function is only valid for installations for self- consumption connected to the grid and discharging energy to the network.
ACTIVATION AND SETTING
The activation and setting of the PV surplus utilization function is done exclusively through the app.
Solar Energy activation. Surplus utilization
Once you have completed the aforementioned steps, access the app with your user name and keyword, and complete the following steps:
- Access section “Heating” from the bottom menu.
- Select and access the appliance you want to set.
- Select the option “Setup” from the bottom menu
- Turn on or off the PV surplus utilisation function through the activation or deactivation of the “Activation State” parameter in the “Solar Energy” menu.
Solar Energy settings. Surplus Utilization
When switching on the Solar Energy function, the setting options will be
automatically displayed. Set them according to your needs.
These are the setting options available:
- Charge settings:
- Solar Alone. Ecombi Solar will only consume and store energy when there are photovoltaic surpluses.
- Solar and Off-peak. Ecombi Solar will charge and store energy whenever there is surplus. In addition, it will also charge during the Off-peak period. You can set the off-peak maximum charge (%) using the corresponding option.
- Solar and Grid Adjustment. Ecombi Solar will charge and store energy whenever there is surplus. It will also charge during the Off-peak period. You can also set the off-peak maximum charge (%) using the corresponding option. In addition, this setting mode offers some other functions
- The storage heater can connect the balance heating element to provide immediate heat when the ambient temperature is lower than the setting temperature.
- The appliance will self-regulate the charge level during the off-peak period according to the temperature records in precedent days.
- Solar Power Activation:
- Indicates the percentage of solar Energy required to active the next power level (%).100% by default
- Off-peak maximum charge
- Maximum charge level during the off-peak period (%). 80% by default
- Ambient temperature over heating protection.
- This protection will stop the solar PV charging when the ambient temperature reaches set-point temperature plus ambient temperature over heating protection. Default 3ºC.
- Solar priority:
- Solar PV charging priority. Devices with high priority will charge first in relation to low priority storage heaters when there is PV Solar extra energy
ADVANCED SETTINGS
With the general settings menu, you can make additional changes and
adjustments in device start-up and operation. To access the settings menu of
the device, press and hold the button for 5 seconds in the home
screen of any operating mode of the device with the screen lit. The following
screen appears:
Use or to move up and down. Confirm with to enter the desired setting.
Operating mode
Scroll down to Operating Mode and press to access the operating mode
selection menu. A new screen will appear with the selectable operating modes:
-
Basic mode or 24-hour temperature mode: The storage heater retains the setpoint temperature for 24 hours. In this mode, the device automatically regulates and adjusts its charge day by day in order to maintain the temperature selected with minimum expense. To change the basic mode setpoint temperature value, simply press or when the device is operating in this mode until the desired temperature is displayed. The setpoint temperature and the charge level are displayed on the screen in this mode.
ADJUST SETPOINT TEMPERATURE
-
Weekly programme: The setpoint temperature varies in accordance with the weekly programme set in the unit. 3 temperature levels (Comfort, Eco and Frost Protection) can be selected for each time interval (1 hour) in order to adjust the temperature of the room to the habits and needs of the different users. You can alter the setpoint temperature of each of the 3 temperature levels (See section 3.3.1 Temperatures. Edit Programme) as well as the corresponding temperature level at each hour of the week. (See section 3.3.2 Weekly programme. Edit programme). The horizontal temperature display for the 24 hours of the current day appears on the screen together with the setpoint temperature of the current period.
-
Off: The storage heater does not retain any temperature or follow any programming, as it retains the time setting previously set. The compensation element will be activated if the room temperature is below the Frost Protection in order to prevent freezing. The set point temperature (3ºC) and the Frost Protection message appear on the screen.
Date and time
You can see the device time at any time in the top left corner of the screen. The date can be seen in the “Date and Time” menu.
To change the time or the date, access the advanced settings menu by pressing
for 5 seconds and then access
the “Date and Time” menu. The Date and Time menu will allow you to change the
following values:
- Date: Use or to select the desired day/month/year. Confirm with .
- Time: Use or to select the desired hour/minute. Confirm with .
- Date format: Use or to select the desired format. Confirm with .
- Time format: Use or to select the desired format. Confirm with .
If the device is connected to a G Control hub, the time setting is overridden
and the hub time is set automatically. In this case, the time set menu will
not be accessible.
The Ecombi Solar automatically changes the time from wintertime to summertime
and vice-versa, even if it is not connected to the G Control hub, provided
that the Automatic Time Change parameter is activated. (Activated by factory
setting).
Programme Settings
This menu will only be accessible when the device is operating in the
operating mode Weekly Programme. In this menu, you can change the comfort, eco
and frost protection temperatures and select or change the existing weekly
programming.
To do this, access the advanced settings menu by pressing
for 5 seconds and then go into the “Programme settings” menu.
Temperatures. Programme Settings
You can change the setpoint temperature value of the 3 temperature levels used
in the Programme Mode (Comfort, Eco and Frost Protection) at any time.
To do this, access the “Temperatures” menu and change “Comfort”, “Eco” or
“Frost Protection” as you wish. Press to exit the home menu.
It is possible to change the setpoint temperature temporarily in the home
screen during the current period of the programme mode.
You can do this by simply pressing the or
buttons. The temporary change is retained until the next change of programmed
period.
Weekly Programme. Programme Settings.
In the “Weekly Programme” menu you can select from one of the 3 predefined programmes or you can edit the existing programme from the “Weekly Programme” menu in order to set a customised programme.
PREDEFINED PROGRAMMES
In this section you have the option of selecting one of the 3 operating programmes preset in the device.
Programme 1 (At home)
Monday to Sunday:
- 00:00 – 07:00 Eco ( )
- 07:00 – 22:00 Comfort ( )
- 22:00 – 00:00 Eco ( )
Programme 2 (Work M-F)
Monday to Friday:
- 00:00 – 07:00 Eco ( )
- 07:00 – 08:00 Comfort ( )
- 08:00 – 17:00 Eco ( )
- 17:00 – 22:00 Comfort ( )
- 22:00 – 00:00 Eco ( )
Saturdays and Sundays:
- 00:00 – 07:00 Eco ( )
- 07:00 – 22.00 Comfort )
- 22.30 – 00:00 Eco ( )
Programme 3 (Office hours)
Monday to Sunday:
- 00:00 – 07:00 Eco ( )
- 07:00 – 18:00 Comfort ( )
- 18:00 – 00:00 Eco ( )
WEEKLY PROGRAMME:
If you do not want to use any of the factory preset programmes, you can set a
customised programme from the “Weekly Programme” menu.
To do this, scroll down to the day that you want to programme and press . Select “Edit” and press to programme the day selected.
The first segment of the day of the week corresponding to the period 00:00 → 01:00 starts to flash. The bar diagram at the top part of the screen represents the temperature levels programmed for each hourly period of the day in question.
- 3 bars represent the hourly period with comfort temperature programmed. ( )
- 2 bars represent the hourly period with eco temperature programmed. ( )
- 1 bar represents the hourly period with frost protection temperature programmed. ( )
By pressing you can select the desired temperature level for the current hourly period: Frost Protection , Economy or Comfort .
Press to go to the next hour. When you have set the different hourly periods for the day selected, press and the setting for this day will be recorded.
COPY THE DAILY PROGRAMME, GO TO THE NEXT DAY
You can copy the programme of the current day to the other days of the week.
To do this, scroll down to the day that you want to copy. Press
and select “Copy”.
Select the days you want to copy the programme to.
Scroll down to “Save”, press and the copy of the programme
will have finalised.
If you want this setting to be stored as a preset programme, select “Save” in
the next screen.
Press and a new preset programme will
be generated with the name USER, which you can see and select at any time in
the “Preset Programmes” menu.
Ecombi Solar will not charge at intervals set to Frost Protection . It is recommended to reserve this temperature level solely for complete days on which you do not require heating.
Charge setting
The Charge Setting menu allows you to change the factory preset charging
period of your storage heater to match the off-peak period of your hourly
tariff, as well as the days of the week on which you need the storage heater
to charge. The standard factory preset period is 00:00 to 08:00 and the charge
is active every day of the week.
Charging periods
Go into the “Charging Periods” menu if you want to change the charging periods
for your device.
2 charging periods are selected in Ecombi Solar.
- 1st charging period: Factory setting of 00:00 to 08:00.
- 2nd charging period: (Factory disabled, 00:00 to 00:00)
The factory setting for both periods can be changed as you wish. Enter the period that you want to alter and change the start and end time to adapt to your tariff.
The factory charging period will be from 22:00 to 12:00 in winter and from 23:00 to 13:00 in summer, if the nominal charging time of 14 hours is activated in the Advanced Settings menu (See section 3.5. Advanced Settings)
Charging days in the week
It is possible to select the days of the week on which the Ecombi Solar heater will charge and those on which it will not. Access the “Charging Days” menu and select the days on which you want the storage heater to charge.
If a day of the week is selected as a non-charging day, the Ecombi solar heater automatically sets the Frost Protection setpoint for this day in the Programme mode and automatically assigns this temperature to the 24 hours of the non-charging day in the Basic mode.
Initial charge
The initial factory setting charge is 100%. It is the charge value of the device at the start of an extended period of inactivity or from its installation. Subsequently, during its operation, the device self-regulates the day-to-day level of charge so that it operates efficiently in accordance with energy needs.
To change the charge percentage, from the “Initial Charge” menu, go into “Edit”, select the desired charge value and select “Save”.
If the balancing heating element is disabled, Ecombi Solar will not automatically calculate the day-to-day charge and will always retain the maximum charge value that has been set in the initial charging parameter as the target charge.
Advanced settings
With the advanced settings menu, you can change general settings in the
device, as well as its advanced operating settings. To access the advanced
settings menu, press for 5 seconds and then select
the “Advanced” menu. The Advanced Settings menu comprises the following parts:
- General settings.
- Operating settings.
- Reset.
- Parameters (Reserved for installer and factory settings. Any change can alter the behaviour of the device).
General settings
- LANGUAGE: Select the language that you want.
- UNITS: Choose between “Celsius” and “Fahrenheit”, according to the temperature unit that you want.
- AUTOMATIC TIME CHANGE: Activate or disable the automatic time change, from winter to summer and viceversa.
- AMPLIFIER: Activate or disable the sound of the keystrokes on the keyboard.
- SCREEN:
- Time on: selects the time it takes for the display to turn off after you stop using the keyboard.
- Brightness activated: selects the percentage of brightness when the screen is on.
- Brightness disabled: selects the percentage of brightness when the screen is off.
- Style: select the screen design style.
- Light B/W: white background and black letters.
- Dark B/W: black background and white letters.
- Colour: Home screen with coloured icons.
Operating settings
- BLANCING HEATING ELEMENT:
- Status: Balancing heating element active or inactive.
- Maximum peak times: Maximum operating time of the balancing heating element during tariff on-peak periods. Set this value to “0” to disable the operation of the balancing heating element in tariff on-peak periods; in this case the charge correction will not work and the same level of charge will apply to every day. (Factory setting: 5 hours for nominal charge of 8 hours, 3 hours for nominal charge of 14 hours).
- Weekend restriction: Restricted operation of the balancing heating element at weekends. If this is activated, the restriction set in “Maximum peak times” for the maximum operating times also applies to weekends. If it is disabled, this restriction does not apply to weekends. (Factory setting: On). Only available if the device is set to 8 hours nominal charging time.
- FROST PROTECTION: Activate or disable the frost protection mode if the device is operating in Off mode.
- OVERLOAD PROTECTION: Protection against excessive temperature whilst charging. Degrees above the comfort setpoint at which the storage heater stops charging. (Selectable values 0,1,2,3,4 and 5).
- CONTROL TYPE: Select the temperature control type. A PID device with default settings programmed is recommended.
- OPEN WINDOW DETECTION: Activates when open windows detected (On/Off).
- INTELLIGENT START-UP: Adaptable start-up activation (On/Off).
- COMPENSATION: Correction of room temperature (Values from -5ºC to 5ºC).
- NOMINAL CHARGE: Ecombi Solar can operate with hourly discrimination tariffs of 8 or 14 off-peak hours. Set the device for 8 or 14 hours according to the number of off-peak hours of your tariff.
Reset and default factory settings
You can reset the unit and restore factory setting configuration.
Default Values
Parameter | 8 hours setting | 14 hours setting |
---|---|---|
Sun : Comfort temperature | 21ºC | 21ºC |
Moon : Economic temperature | 18ºC | 18ºC |
Frost protection temperature | 3ºC | 3ºC |
UP01 : Initial % of storage charge | 100% | 100% |
UP02 : Starting time off peak period 1 | 00:00 | 22:00 |
UP03 : Ending time off peak period 1 | 08:00 | 12:00 |
UP04 : Starting time off peak period 2 | 00:00 | 00:00 |
UP05 : Ending time off peak period 2 | 00:00 | 00:00 |
UP06 : Charging days of the week | Charging 7 days of the week. | Charging 7 |
days of the week.
UP07: Ambient sensor Offset| 0ºC| 0ºC
UP08 : Max. Balancing element – working period| 5 hours| 3 hours
UP09 : Overtemperature protection| 2ºC| 2ºC
UP10 : Temperature Unit| ºC| ºC
UP11 : Open Window Detection Function| Off| Off
UP12: Adaptive Start Control| Off| Off
UP13: Kind of temperature control| PID| PID
UP14 : Weekend Balancing Element restriction| On| N/A
Incorrect time settings, erroneous programming of the reduced rate time and too high temperature settings may result in a high cost of your electricity bill.
Emitter Mode
This operation mode is used when it is necessary to heat the room temporarily and there is no need for storage heating. To set this mode, turn off the unit by pressing the main switch on the back-side panel and keep pressed at the same time you turn on the unit by pressing the main switch until the message 19.0E is displayed on the display.
- Emitter mode is a temporary operation mode. You cannot access from this mode to general setting menu, operation mode menu or any other settings.
- Use and to modify the set-point temperature for this operation mode. The unit will turn on the balancing heating element if required in order to provide instantaneus heat to the room.
- The unit will not charge within this mode.
To exit emitter mode and go back to the commom operation mode, just turn off and turn on the unit again by pressing the main switch on the back-side panel.
REMOTE OPERATION USING THE G-CONTROL HUB
It is possible to control the full operation of the unit remotely with the Elnur Gabarron Wifi Control app or the app-web (https://remotecontrol.elnur.es). The unit must be connected to a G-Control Hub connected to the internet to use this feature.
To associate the ECOMBI SOLAR unit to the G-Control Hub, follow the instructions of the installation wizard of the app.
- Open the application and login with your user and password.
- Access the heating menu in the top menu in the app.
- Press the button (+) and select the type of heater that you are going to connect (Storage heater).
- Press Start Search and follow the instructions of the installation wizard.
When required, keep pressed button during 3 seconds until the
symbol is displayed in the storage heater display.
You can control now and adjust the settings of your storage heater using the
Elnur Gabarron Wifi Control app or the app-web
https://remotecontrol.elnur.es.
TROUBLESHOOTING
ECOMBI SOLAR does not heat.
| ****
Please check it is connected and switched on.
Make sure the device is not covered or the lower air inlets are not obstructed. The LR safety limit may be activated; in this case it is necessary to reset it manually. Please contact technician.
---|---
ECOMBI SOLAR does not reach set up temperature| Make sure that
adequate temperature is selected.
Make sure the storage heater is sized correctly for heat loss.
Error messages in display
| ****
Please contact technician.
ECOMBI SOLAR does not communicate with the G Control Hub.| Check the unit is associated, the symbol must be shown on the display.
For distances greater than 30 metros and 2-3 walls, associate first the closest units. Each unit can work as signal extender.
If symbol is flashing, check the G Control Hub connexion to the network, and if any other device in the RF Net that could be working as signal extender has been removed.
CLEANING MAINTENANCE INSTRUCTIONS
Before cleaning, make sure the power has been turned off at the circuit
breaker panel and that the heating element of the heater is cool.
Occasionally, clean dust with a dry, soft cloth. Do not use any solvent or
abrasive product for cleaning.
When the Heating season is finished, please disconnect the device by turning
off the power switch located at the right back of the unit or at the circuit
breaker.
Any other servicing should be performed by an authorized technician.
ECOMBI SOLAR has been manufactured under a fully assured quality system and using environmentally friendly processes. Once its useful life is finished please take the device to a recycling depot so that its components can be recycled in an appropriate way.
MAIN COMPONENTS LIST
-
Storage Heating Element (All except ECO15 Solar)
Ref. 15190091 -
Power PCB & Fixing Bracket
Ref. 15191890 -
Storage Heating Element (ECOI5 Solar)
Ref. 15190875 -
Keyboard PCB ECO Solar
Ref. 15190298 -
350W Balancing Heating Element (ECOI5/20 Solar)
Ref. 15190111 -
Room Sensor
Ref. 46102195 -
450W Balancing Heating Element (ECO30 Solar)
Ref. 15190121 -
110ºC Balancing Element Limiter
Ref. 15190725 -
600W Balancing Heating Element (ECO40 Solar)
Ref. 15190131 -
135ºC Cut Out Manually Limiter
Ref. 10190460 -
Switch
Ref. 15190055 -
Core Sensor
Ref. 15192140
THECNICHAL FEATURES
ECO15 Solar | ECO20 Solar | ECO30 Solar | ECO40 Solar | |
---|---|---|---|---|
Connection | 220 – 240V ~ | 220 – 240V ~ | 220 – 240V ~ | 220 – 240V ~ |
Balancing Element Output | 350W | 350W | 450W | 600W |
Insulation | Class I | Class I | Class I | Class I |
Length | 55cm | 66cm | 89cm | 111cm |
Height | 73cm | 73cm | 73cm | 73cm |
Depth | 18cm | 18cm | 18cm | 18cm |
Weight | 59kg | 77kg | 112kg | 147kg |
Number of bricks | 4 | 8 | 12 | 16 |
Brick Package | 11072 | 11016 | 11016 | 11016 |
8 Hours Configuration
Storage Heater Output| 975W| 1300W| 1950W| 2600W
Charge Period| 8h| 8h| 8h| 8h
Charging| 7.8 kWh| 10.4 kWh| 15.6 kWh| 20.8 kWh
14 Hours Configuration
Storage Heater Output| 975W| 650W| 1300W| 1300W
Charge Period| 14h| 14h| 14h| 14h
Charging| 9.5 kWh| 9.1 kWh| 15.5 kWh| 18.2 kWh
Storage heater elements and balancing heating element will never operate at the same time.
The symbol on the product or in its packaging indicates that this product may
not be treated as household waste.
Instead it shall be handed over to the applicable collection point for the
recycling of electrical and electronic equipment. By ensuring this product is
disposed of correctly, you will help prevent potential negative consequences
for the environment and human health, which could otherwise be caused by
inappropriate waste handling of this product. For more detailed information
about recycling of this product, please contact your local city office, your
household waste disposal service or the shop where you purchased the product.
These instructions are only valid in the EU member states.