ELNUR GABARRON RD4W Wifi Thermal Radiators Instruction Manual

June 9, 2024
ELNUR GABARRON

INSTALLATION INSTRUCTIONS AND USER GUIDE
WIFI THERMAL RADIATORS
INGENIUM

ELNUR GABARRON RD4W Wifi Thermal Radiators

MODELS
RD4W RD10W/RD6W RD12W
RD8W RD14W

Please read these instructions carefully before installing or using this appliance for the first time.

WARNING

Please read these instructions before installing or using this appliance for the first time.

  • The warranty of the heater will not cover any damage caused by non-observance of any of these instructions.
  • The instructions should be retained for future reference. This guide must be kept and given to any new owner.
  • This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning the use of the appliance in a safe way and understand the hazards involved. Children must not play with the appliance. Cleaning and user maintenance must not be made by children without supervision.
  • Children aged from 3 years and less than 8 years shall only switch on/off the appliance provided that it has been placed or installed in its intended normal operating position and they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved. Children aged from 3 years and less than 8 years shall not plug in, regulate and clean the appliance or perform user maintenance.
  • Children of less than 3 years should be kept away unless continuously supervised.
  • Please check that the voltage in the rating label fits the power supply.
  • The use of these heaters is forbidden in any area where there is a presence of gases, explosives or inflammable objects.
  • Do not use this heater to dry clothes. Do not cover this heater or put objects in contact with it.
  • Neither the connecting cable nor any other object must come into contact with the hot unit.
  • Do not cover this heater at any time.
  • The air outlet at the top of the thermal radiator and the air inlet at the bottom are provided to ensure the most efficient operation of the appliance. They also protect the heater from overheating; therefore, it is essential that at no time are they covered.
  • This heater should be switched off at the isolating switch before any repair work is carried out.
  • The installation must be carried out in accordance with the current electrical regulations.
  • Should the heater be moved and reinstalled it is essential that the work is carried out by a fully qualified technician.
  • The heater should not be installed just below an electrical socket.
  • The appliance must be installed in such a way that it is impossible for anyone using a bath or shower, to touch the controls.
  • The heater is fitted with a flexible cable size 3 x 1.00 mm² for electrical connection. It may be used to connect the heater to the fixed wiring of the premised through a suitable connection box positioned adjacent to the heater.
  • The supply circuit to the heater must incorporate a double pole isolating switch having a contact separation of at least 3 mm.
  • If the flexible power cable for this unit is damaged, it may only be replaced by a repair workshop recognised by the manufacturer, as special tools are necessary.
  • This appliance must be earthed.
  • All models are supplied with an electrical interrupt cut-out. This will switch off the heater if, for any reason, it overheats. Should the cut-out operate, turn the heater off and remove the cause for the overheating. The cutout will be reset automatically.
  • This heater is filled with a precise quantity of special oil. Repairs requiring opening of the oil container are only to be made by the manufacturer or his service agent who should be contacted if there is an oil leakage.
  • Regulations concerning the disposal of oil when scrapping the appliance have to be followed.
  • The presence of air particles of smoke, dust and other pollutants could, in time, discolour the walls and surfaces around the heater.
  • CAUTION — Some parts of this product can become very hot and cause burns. Particular attention must be given when children and vulnerable people are present.

INSTALLATION INSTRUCTIONS

– Open the package and check that it is the correct model and it is in good condition- To obtain optimum performances it is necessary to maintain a minimum clearance of
15 cm between the radiator and any inflammable material as furniture, curtains etc.
– The rest of clearances required to maintain are indicated on the following figure:

ELNUR GABARRON RD4W Wifi Thermal Radiators - Fig 1Position and fix the brackets at the correct distance from the floor. It is possible to use the radiator as measuring unit by positioning it on two polyester package elements and
placing two supports above as indicated on the figure:

ELNUR GABARRON RD4W Wifi Thermal Radiators - Fig 2

– The studs and screws to attach the supports are in the accessories bag.
– Hang the unit on the hooks of the brackets.
– By turning the screw the metallic square will go downwards, retaining the heater. Repeat this on the other bracket.

USING THE THERMAL RADIATOR

ELNUR GABARRON RD4W Wifi Thermal Radiators - Fig 3

BACKLIGHT
Pressing any button the display will illuminate with a soft white colour. After certain time if no buttons are pressed the display
backlight will turn off.

OPERATING MODES
Press , the operation modes are displayed, with the selected one flashing. Use or to select the desired operation mode. Confirm with .
The heater has three different operation modes: Auto, Manual override and OFF.

ELNUR GABARRON RD4W Wifi Thermal Radiators - Fig 4

3.1. ON/OFF
Once the heater is connected to a main supply you can turn the heater ON by switching the main ON/OFF switch positioned at the rear right side of the heater as shown above.

3.2. SETTING THE TIME
We start by first setting the Day and Time.

3.2.1 You can do this by Press & Holding the Config/Prog. button until the following is shown.
Press & Release the Config/Prog button 7 times again to advance through the 7th days programming.

3.2.2. When pressing Config/Prog button when the 7th day programming is displayed, you enter in the Time Setting. The day of the week starts to flash. Using the “+” and “-” buttons select today’s date. 1=Monday, 2=Tuesday, Etc. and Press the OK/Mode button.

3.2.3 Now the hours start to flash. Press the “+” and “-” button until you reach the correct time (hour) and Press the OK/Mode button.

3.2.4 Now the minutes start to flash. Press the “+” and “-” button until you reach the correct time (minutes) and Press the OK/Mode button.

If the device is associated with a G-Control Hub, the adjustment of time is removed and the time in the G-Control Hub is configured in the heater automatically.

3.3. PROGRAMMING
Select Auto Mode. Within this mode, the setpoint temperature varies according to the weekly schedule setup in the unit.
Default programming is: Comfort: 07:00 to 22:00 / Eco: 00:00 to 07:00 & 22:00 to 00:00.
3.3.1 Press & Hold the Config/Prog. button until the following is shown. The first segment will start to flash. By pressing the
OK/Mode button you can select whether you want a Frost setting (5°C), Background setting (17°C) or Comfort setting (19°C). Now press the “+” button to move to the next 1 hour time interval.
Note: These temperatures can be changed later without adjusting the times.

ELNUR GABARRON RD4W Wifi Thermal Radiators - Fig 9

3.3.2 Once you’ve gone through all the time intervals for day 1, you will automatically start on day 2. Repeat the above steps until you go through all 7 days. If you do not desire to modify the programming of a specific day, use the Config/Prog button to advance to the next day programming. Once you have configured the desired programming, press Config/Prog button to exit programming in the 7th day programme.

3.3.3. After going through all the days the display will show and start to run the program and will flash between the set temperature for the current day, time interval and the word Pro to indicate the heater is running the set program.

ELNUR GABARRON RD4W Wifi Thermal Radiators - Fig 11

3.4. TEMPERATURE LEVELS
In the AUTO mode, you can temporary change the set temperature for the time period. You can increase or decrease this temperature simply by pressing the “+” or “-” buttons. Once the time period finishes, the temperature will revert back to the programmed set temperature.

You can modify the set temperatures within the program permanently too, to do this, Press & Release the Config/Prog. button until the display shows the flashing  temperature symbol . Now press the OK/Mode button to select the temperature you want to change, COMFORT or ECONOMIC, and use the “+” or “-” button to select the desired temperature.

COMFORT: Recommended for the periods of time when the user is at home and the maximum comfort is required. Default value 19ºC.
ECONOMIC: Recommended for nights and small away periods of time. Default value 17ºC.
FROST PROTECTION: Recommended for long away periods of time. Default value 5ºC.

It is possible to exit of temperature level configuration by pressing the Config/Prog button at any time.

3.5. MANUAL OVERRIDE
In manual mode, the heater will maintain the temperature set point and will ignore the pre-set program. By default, the initial temperature set point is 19°C.
3.5.1 To modify the temperature set point, Press the “+” or “-” button until the desired temperature is shown. The heater will now cycle on and off and maintain this temperature setting. If the room temperature goes below the set temperature, then the heaters element will turn on and the symbol will be shown. If the room  temperature is higher than the set temperature, then the heaters element won’t turn on and the heating symbol won’t be displayed.

3.6. OFF MODE
It is possible to put the heater in standby mode where the heater doesn’t maintain any set temperature or run any programs, keeping the time settings configured previously. When in this mode, the heater will display the current time and the word .
3.6.1 To select the OFF mode, Press , operation modes are displayed, with the selected one flashing. Use or to select mode. Confirm with .

3.6.2 If the heater is turned off via the main switch at the back of the heater or if the power to the heater is removed and the heater is not connected to a Wifi G- Control Hub then the time setting within the heater will be lost.
3.7. OPEN WINDOW DETECTION
With open window detection activated, the heating element will be disconnected automatically when a sharp decrease in temperature in the room is detected avoiding energy wastage. After this period of time, the radiator returns to the prior operation mode.
It will be shown in the display as follows:

Note: To activate the window detection please refer to C5 in 3.10. ADVANCED CONFIGURATION section.

3.8. ADAPTIVE START CONTROL
Ingenium electronic control analyses the heating requirements of the room where the radiator is installed using this information to turn on the heating element in advance in order to reach the set point temperature at the desired time.
It will be shown in the display as follows:

3.9. KEYBOARD LOCK
In every operation mode, it is possible to lock the keyboard by holding “+” and “-” buttons simultaneously for 3 seconds. When the keyboard is locked, the message Lock will be displayed.
When the keyboard is locked, if any button is pressed, the display will show “Lock” and the unit will not respond.

To unlock the keyboard, press the “+” and “-” buttons simultaneously for 3 seconds.

3.10. ADVANCED CONFIGURATION

3.10.1 To access to advanced configuration menuPress & Release Config/Prog button until the follow is displayed:

3.10.2 Hold the Config/Prog button for 5 seconds, the first parameter (C1) will be displayed. To select the next parameter, press the “+” button.

To modify the value of the parameters, press the OK/Mode button. Then use the “+” and “-” buttons to select the different options. Press the Ok/Mode button again to set the value.

Use the same procedure to modify the others parameters where necessary. It is possible to exit of advanced configuration by pressing the Config/Prog button at any time.

Parameters
– C1. Fahrenheit or Celsius Degrees.
The LCD displays the temperature unit selected: ºC or ºF.
– C2. Control Adjustment.
The kind of temperature control can be modified with this parameter:
• PID, Hysteresis 0,25ºC, Hysteresis 0,35ºC, Hysteresis 0,50ºC, Hysteresis 0,75ºC.
– C3. Correction of ambient temperature measures.
If there is a difference between an external thermometer and the temperature displayed by the unit, with C3 parameter it is possible to influence on the sensor in order to balance the difference. (-3ºC to +3ºC in 0,1 steps).
– C4. Firmware version.
Information about the current firmware version of the unit.
– C5. Open Window Activation
ON/OFF. With the parameter in ON, the open window detection is activated.
– C6. Adaptive Start Control
ON/OFF. With the parameter in ON, the adaptive start control is activated.

REMOTE OPERATION USING THE WIFI G-CONTROL HUB

It is possible to control the full operation of the unit remotely with the Elnur Gabarron Wifi Control app or the app-web (https://remotecontrol.elnur.es). The unit must be connected to a G-Control Hub connected to the internet to use this feature.
To associate the INGENIUM unit to the G-Control Hub, follow the instructions of the installation wizard of the app.
– Open the application and login with your user and password.
– Access the heating menu in the top menu in the app.
– Press the button (+) and select the type of heater that you are going to connect (Heater).
– Press Start Search and follow the instructions of the installation wizard.

ELNUR GABARRON RD4W Wifi Thermal Radiators - Fig 20

When required, keep pressed OK/Mode button during 3 seconds until the symbol is displayed in the storage heater display.
You can control now and adjust the settings of your storage heater using the Elnur Gabarron Wifi Control app or the app-web https://remotecontrol.elnur.es.

UNIT RESET AND DEFAULT VALUES

The heater reset removes the programming and disassociates the device from the RF network if the unit was associated with a G-Control Hub. Default values are established. To reset the unit, hold the OK/Mode and Config/Prog buttons simultaneously for 10 seconds, the next figure will show the following to indicate the heater has been reset.

To confirm the reset of the unit, press OK/Mode button, to cancel it any other button can be pressed.

Operation mode OFF
Comfort temperature 19°C
Economic temperature 17°C
Frost protection temperature 5°C
Ambient sensor Offset 0°C
RF associated No
Temperature Unit °C
Open Window detection Disabled
Adaptive Start Control Disabled
Control mode PID
Default Programming in AUTO Mode Comfort: 07:00 to 22:00.

Eco: 00:00 to 07:00 & 22:00 to 00:00.

CLEANING AND MAINTENANCE

The radiators do not precise any special maintenance providing thermal comfort during large periods. Clean dust with a dry, soft cloth only when the unit is disconnected and cold.
Do not use solvents or abrasive products for cleaning.
After the heating season disconnect the radiator with the switch located on the back surface of the radiator.
This thermal radiator has been manufactured under an assured quality system using environment friendly processes.
Please take the heaters to a clean point once their useful life is finished, in order to recycle their materials in the right way.

TROUBLESHOOTING

The radiator does not heat.| Check the heater or the air inlets are not covered.
---|---
The room does not reach the required temperature.| Check the selected temperature is in accordance with the desired temperature. Maybe the room needs more heating power.
“OC”, “SC” message is displayed.| Sensor wrong connection. Contact the after sales service.
“Err I “, “Err2”, “Err3”, “Err4” message is displayed| Contact the after sales service.
Time settings are lost.| There was electric supply shortage or the unit has been disconnected by the main switch.
The keyboard does not respond.| If the Lock message is displayed, the thermal radiator keyboard is locked. Hold “+” and “-” buttons simultaneously for 3 seconds to unlock the keyboard.
The radiator does not communicate withthe G Control Hub.| Check the unit is associated, the symbol Link must be shown on the display LCD.
For distances greater than 30 metros and 2-3 walls, associate first the closest unit because of each unit can work as repeater.
If Link symbol is blinking, check the G Control Hub connexion to the network, and if any other device in the RF Net that could be working as repeater has been removed.

MAIN COMPONENTS LIST

Right side plastic case
Left side plastic case
Electronic Control PCB (Except RD14W model)
Electronic Control PCB (Only RD14W model)
Main Switch
Temperature sensor
85ºC thermal limiter| ref. 46102362
ref. 46102364
ref. 46102300
ref. 46102310
ref. 46100530
ref. 46102195
ref. 30100040| 500 W Heating Element
750 W Heating Element
1000 W Heating Element
1250 W Heating Element
1500 W Heating Element
2000 W Heating Element| ref. 30100142
ref. 30100152
ref. 30100162
ref. 30100172
ref. 30100182
ref. 30100202
---|---|---|---

**** The symbol on the product or in its packaging indicates that this product may not be treated as household waste. Instead it shall be handed over to the applicable collection point for the recycling of electrical and electronic equipment. By ensuring this product is disposed of correctly, you will help prevent potential negative consequences for the environment and human health, which could otherwise be caused by inappropriate waste handling of this product. For more detailed information about recycling of this product, please contact your local city office, your household waste disposal service or the shop where you purchased the product. These instructions are only valid in the EU member states.

WARNING: In order to avoid overheating do not cover the heater.

WIRING

ELNUR GABARRON RD4W Wifi Thermal Radiators - Fig 22

ELNUR GABARRON RD4W Wifi Thermal Radiators - Fig 23

TECHNICAL SPECIFICATIONS

Model| RD4W| RD6W| RD8W| RD10W| RD12W| RD14W
---|---|---|---|---|---|---
Elements| 4| 6| 8| 10| 12| 14
Length (cm)| 42| 58| 74| 90| 106| 122
Width (cm)| 8 cm plus 2 cm clearance| | | | |
Height (cm)| | | | 58| |
Weight (kg)| 8| 11| 14| 16.5| 19.5| 22.5
Voltage| | | 220 – 240 V~| | |
Isolation| | | Clase I /Class I| | |
Power (W)| 500| 750| 1000| 1250| 1500| 2000
Electronic Control| Triac| Triac| Triac| Triac| Triac| Relay

All models are equipped with control function trough G-Control Hub connected to the network.

PRODUCT FICHE

MODEL(S): ELNUR GABARRON RD4W, RD6W, RD8W, RD10W, RD12W, RD14W

Item Symbol Value Unit
RD4W 1 RD6W RD8W RD I OW

Heat Output
Nominal heat output| Pnom| 0.5| 0.75| 1.0| 1.0| 2.0| 2.0| kW
Minimum heat output| Pmin| N.A.| N.A.| N.A.| N.A.| N.A.| N.A.| kW
Maximum continuous heat output| Pmax,c| 0.5| 0.75| 1.0| 1.0| 2.0| 2.0| kW
Auxiliary electricity consumption
At nominal heat output| elmax| 0.000| 0.000| 0.000| 0.000| 0.000| 0.000| kW
At minimum heat output| elmin| 0.000| 0.000| 0.000| 0.000| 0.000| 0.000| kW
In standby mode| elSB| <0.0005| <0.0005| <0.0005| <0.0005| <0.0005| <0.0005| kW
Item| Value. All models
---|---
Type of heat output / room temperature control
Electronic room temperature control plus week timer| Yes
Other control options|
Room temperature control, with open window detection| Yes
With distance control option| Yes
With adaptive start control| Yes

Contact details
ELNUR, S.A.
Travesía de Villa Esther, 11
28110 – Algete (Madrid), Spain

Commission Regulation (UE) 2015/1188 of 28 April 2015. Ecodesign requirements for electric fixed local space heater.

ELNUR S.A.
Travesía de Villa Esther, 11
28110 Algete – Madrid
Tfno. Atención al Cliente:
+34 91 628 1440
www.elnurgabarron.es
www.elnurgabarron.com
www.elnur.co.uk

As a part of the policy of continuous product improvement Elnur, s.a. reserves the right to alter specifications without notice.

46102370 R3

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>