KOZY HEAT NDK-48-DV Direct Vent Gas Fireplace Instruction Manual

June 17, 2024
Kozy Heat

KOZY HEAT logo HUSSONG MANUFACTURING CO., INC.
P.O. BOX 557 204 INDUSTRIAL PARK DRIVE
LAKEFIELD, MINNESOTA USA 56150-0577
INSTALLATION AND
OPERATION MANUAL

NDK-48-DV Direct Vent Gas Fireplace

Nordik 48 DV
Model #NDK-48-DV
Direct Vent Gas Fireplace
Evolution of Fire™
with the EVO Elevated Burner™
English and French installation manuals are available through your local dealer or website. Visit our website www.kozyheat.com. KOZY HEAT NDK-48-DV Direct Vent
Gas Fireplace

WARNING: FIRE OR EXPLOSION HAZARD
Failure to follow safety warnings exactly could result in serious injury, death, or property damage.
Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.

WHAT TO DO IF YOU SMELL GAS

  • Do not try to light any appliance.
  • Do not touch any electrical switch; do not use any phone in your building.
  • Leave the building immediately.
  • Immediately call your gas supplier from a neighbor’s phone. Follow the gas  supplier’s Instructions.
  • If you cannot reach your gas supplier, call the fire department.

Installation and service must be performed by a qualified installer, service agency or the gas supplier

This appliance may be installed in an aftermarket, permanently located, manufactured home (USA only) or mobile home, where not prohibited by local codes.
This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases, unless a certified kit is used.

DANGER

HOT GLASS WILL
CAUSE BURNS
DO NOT TOUCH GLASS
UNTIL COOLED
NEVER ALLOW CHILDREN
TO TOUCH GLASS
A barrier designed to reduce the risk of burns from the hot viewing glass is provided with this appliance and shall be installed for the protection of children and other at-risk individuals.

INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future reference.

HOMEOWNER REFERENCE INFORMATION

CONGRATULATIONS!
Hussong Manufacturing welcomes you as a new owner of a Kozy Heat gas fireplace. Kozy Heat products are designed with superior components and materials, assembled with care by trained craftsmen who take pride in their work. To ensure you receive a quality product, the burner and valve assembly are 100 percent test-fired, and the complete fireplace is thoroughly inspected before packaging. Our commitment to quality and customer satisfaction has remained the same for over 40 years. We offer a complete line of gas, wood, and electric fireplaces, along with stylish accessories to complement any decor. Adding a fireplace is one of the best ways to increase the value of your home, and we are proud to offer a network of dealers throughout the country to help make your experience everything you imagine. We pride ourselves in being dedicated not only to functionality and reliability, but also customer safety. We offer our continual support and guidance to help you achieve the maximum benefit and enjoyment from your Kozy Heat gas fireplace.

|
---|---

Read this manual before installing or operating this appliance
Please retain this owner’s manual for future reference.

Homeowner Reference Information
We recommend you record the following Information:

Model Name: …………………………………….. Date Purchased / Installed: ……………………………………………………………..
Serial Number: …………………………………….Location of fireplace: …………………………………………………………
Dealership purchased from: …………………………………. phone number: …………………………………………
Notes: …………………………………………………………………….

Introduction

1.1 Appliance Certification
Laboratory: PFS in Cottage Grove, Wisconsin Standards:

  • ANSI Z21.88-2019/CSA 2.33-2019, Vented Gas Fireplace Heaters
  • CSA 2.17 2017, Gas-Fired Appliances for Use at High Altitudes

This installation must conform with local codes, or in the absence of local codes, with the National Fuel Gas Code, ANSI Z223.1/NFPA 54, or the Natural Gas and Propane Installation Code, CSA B149.1.

1.2 California Proposition 65 Warning
WARNING: This product can expose you to chemicals including Carbon Monoxide, that is an externally vented by- product of fuel combustion, which is [are] known to the State of California to cause birth defects or other reproductive harm.  For moreinformation, visit www.P65Warnings.ca.gov.
1.3 Requirements for the Commonwealth of Massachusetts
The following requirements reference various Massachusetts and national codes not contained in this manual.
For all sidewall horizontally vented gas fueled equipment installed in every dwelling, building or structure used in whole or in part for residential purposes, including those owned or operated by the Commonwealth and where the side wall exhaust vent termination is less than (7) feet above finished grade in the area of the venting, including but not limited to decks and porches, the following require- ments shall be satisfied:
1.3.1 Installation of Carbon Monoxide Detectors
At time of installation of side wall horizontally vented gas fueled equipment, the installing plumber or gas-fitter shall observe that a hard wired carbon monoxide detector with an alarm and battery back-up is installed on the floor level where the gas equipment is to be installed. In addition, the installing plumber or gas-fitter shall observe that a battery operated or hard wired carbon monoxide detector is installed on each additional level of the dwelling, building or structure served by the side wall horizontal vented gas fueled equipment. It shall be the responsibility of the property owner to secure the services of qualified licensed professionals for the installation of hard wired carbon monoxide detectors.
In the event that the side wall horizontally vented gas fueled equipment is installed in a crawl space or attic, the hard wired carbon monoxide detector with alarm and battery back-up may be installed on the next adjacent floor level. In the event that the requirements of this subdivision can not be met at the time of completion of installation, the owner shall have a period of thirty (30) days to comply with the above requirements; provided, however, that during said thirty (30) day period, a battery operated carbon monoxide detector with an alarm shall be installed.
1.3.2 Approved Carbon Monoxide Detectors
Each carbon monoxide detector as required in accordance with the above provisions shall comply with NFPA 720 and be ANSI/UL 2034 listed and IAS certified.
1.3.3 Signage
A metal or plastic identification plate shall be permanently mounted to the exterior of the building at a minimum of eight (8) feet above grade directly in line with the exhaust vent terminal for the horizontally vented gas fueled heating appliance or equipment. The sign shall read, in print no less the one- half inch (½) in size, “GAS VENT DIRECTLY BELOW. KEEP CLEAR OF ALL OBSTRUCTIONS”.
1.3.4 Inspection
The state or local gas inspector of the side wall horizontally vent- ed gas fueled equipment shall not approve the installation un- less, upon inspection, the inspector observes carbon monoxide detectors and signage installed in accordance with the provisions of 248 CMR 5.08 (2) (a) 1 through 4.
1.3.5 Exemptions
The following equipment is exempt from 248 CMR 5.08 (2) (a) 1 through 4: The equipment listed in Chapter 10 entitled “Equipment Not Required To Be Vented” in the most current edition of NFPA 54 as adopted by the Board; and Product Approved side wall horizontally vented gas fueled equipment installed in a room or structure separate from the dwelling, building or structure used in whole or in part for residential purposes.
1.3.6 Manufacturer Requirements
1.3.6.1 Gas Equipment Venting System Provided
When the manufacturer of Product Approved side wall horizon- tally vented gas equipment provides a venting system design or venting system components with the equipment, the instructions provided by the manufacturer for installation of the equipment and
the venting system shall include:

  • Detailed instructions for the installation of the venting system design or the venting system components; and
  • A complete parts list for the venting system design or venting system.

1.3.7 Gas Equipment Venting System NOT Provided
When the manufacturer of Product Approved side wall horizontally vented gas equipment does not provide the parts for venting the flue gases, but identifies “special venting systems”, the following requirements shall be satisfied by the manufacturer:

  • The referenced “special venting systems” instructions shall be included with the appliance or equipment installation instructions and;
  • The “special venting systems” shall be Product Approved by the Board, and the instructions for that system shall include a parts list and detailed installation instructions.

A copy of all installation instructions for all Product Approved side wall horizontally vented gas fueled equipment, all venting instructions, all parts lists for venting instructions, and/or all venting design instructions shall remain with the appliance or equipment at the completion of the installation.

Specifications

2.1 Heating Specifications

| Natural Gas| Propane
---|---|---
Maximum Input Rating| 48,000 Btu/h (14.07 kW)| 48,000 Btu/h (14.07 kW)
Orifice Size (DMS)| Left: #43
Right: #43
Rear: #53| Left: #1.40mm Right: #1.40mm Rear: #69
Minimum Input Rating| 32,000 Btu/h (9.38 kW)| 39,000 Btu/h (11.43 kW)
Minimum Inlet Pressure| 5” WC (1.25 kPa)
7” WC (1.74 kPa)
recommended| 11”WC (2.74 kPa)
Maximum Inlet Pressure| 10”WC (2.49 kPa)| 13”WC (3.24 kPa)
Manifold Pressure (High)| 3.5” WC (0.87 kPa)| 10” WC (2.49 kPa)
Manifold Pressure (Low)| 1.6” WC (0.40 kPa)| 6.4” WC (1.59 kPa)
Venturi Opening Settings| Left : 1/16” (1.5mm) Right: 1/16” (1.5mm)
Rear: 5/16” (8mm)| Left: 1/4” (6mm) Right: 1/4” (6mm)
Rear: 5/16” (8mm)
*There are two venting scenarios where the left and right burner venturi openings must be adjusted to 3/8” (10mm). The first scenario is mini- mum horizontal 5×8 coaxial venting. The second scenario is when the fireplace is reduced down to 4”x6-5/8” coaxial pipe. See Section 8.5 for more venting information. Applies to Propane ONLY.

2.1.1 Altitude Adjustment
This appliance may be installed at higher altitudes. Please refer to National Fuel Gas Code ANSI Z223.1/NFPA 54, CSA-B149.1 Natural Gas and Propane Installation Code, local authorities, or codes having jurisdiction in your area regarding derate guidelines.
2.1.1.1 US Installations
Refer to the American Gas Association guidelines for the gas designed appliances derating method. For elevations above 2,000’ (610m), input ratings are to be reduced by 4% for each 1,000’ (305m) above sea level.
2.1.1.2 Canadian Installations
When the appliance is installed at elevations above 4,500’ (1,372m), the certified high-altitude rating shall be reduced at the rate of 4% for each additional 1,000’ (305m). 2.2 Electrical Specifications

  • The junction box in this appliance requires 120VAC, 60Hz, and 6 Amps.
  • Verify the household breaker is shut off prior to working on any electrical lines.
  • The AC power supply to this appliance must be hot at all times and shall not have a switch installed in it.

2.3 Appliance Dimensions ![KOZY HEAT NDK-48-DV Direct Vent Gas Fireplace

2.4 Safety Barrier Information
WARNING: A barrier designed to reduce the risk of burns from the hot viewing glass is provided with this appliance and shall be installed for the protection of children and other at-risk individuals.
If the barrier becomes damaged, the barrier shall be replaced with Hussong Mfg.’s barriers for this appliance.
Please refer to Section 5.3 Safety Barrier Installations for mounting and installation options.
IMPORTANT: Consider the height of hearth finish material when building a fireplace platform. Proper installation of safety barriers require the bottom of the fireplace to be level with finished hearth.
NOTE: The finishing trim kit is highly recommended as it ensures proper fitment of safety screen barrier along with an edge to stop finishing material against. This ensures proper ventilation air flow and accessibility for fireplace servicing. See Section 5.2.KOZY HEAT NDK-48-DV Direct Vent Gas
Fireplace - Figure 2 IMPORTANT: The NK48-PSF and NK48-FRSF (Figure 2.3) are ONLY approved for use when the Nordik 48 DV is installed with an approved Komfort Zone Kit (#KZK-045).
The other (4) safety barriers shown in Figure 2.2 are approved in all installation scenarios.

Framing

3.1 Appliance Placement Considerations
Read all documentation for your specific installation and design options prior to appliance installation.
WARNING: Due to high temperatures, the appliance should be located out of traffic and away from furniture and draperies.
FIRE HAZARD: Do NOT install this appliance directly on carpeting, vinyl, or any other combustible material other than wood.
Note: Unless otherwise noted all clearances / images in this manual are based off of nominal 2” x 4” framing being used.

  • This appliance must be installed on a level surface capable of supporting the fireplace and venting. If possible, place the fireplace in a position where the vent terminates between two studs, eliminating the need for any additional framing.
  • This fireplace may be installed in a bedroom.
  • Please be aware of the large amount of heat this fire- place will produce when determining a location.

3.2 Appliance Installation Options
This appliance offers several design options for managing the heat produced by this fireplace.
Note : When deciding on which design option suites your application please review all sections throughout this manual as different design options have different framing, facing, and finishing options and requirements.

  • Standard Installation will be outlined in this manual in sections marked ‘standard installation’ and must be followed if no design options (Komfort Zone Kit) are to be used. The fireplace chamber and ceiling minimum height must be 80” (2032mm) for standard installations. Only the safety barriers shown in Figure 2.2 are allowed for this installation scenario.
  • Komfort Zone Kit (KZK) offers the option to redistribute radiant heat through a plenum. This option allows for combustible facing materials above the fireplace, heat reduction for a TV above the fireplace, and lower mantel clearances. See section 4.0, Heat Management on page 21. If installing a Komfort Zone Kit (#KZK-045), the framing requirements may be different than the standard dimensions listed in this section. Please reference the manual included with your kit before completing all fireplace framing and other installation considerations. The fireplace chamber and ceiling minimum height must be 86” (2184mm) for KZK options. Safety barriers shown in Figure 2.2 and Figure 2.3 are allowed for installation when using an approved Komfort Zone Kit. Safety barriers shown in Figure 2.3 are only allowed for use with an approved Kozy Zone Kit.
  • Kozy Power Vent is a fan-powered mechanical draft vent system (horizontal terminations only) for use with any of the design options listed previously in this section (Standard or Komfort Zone Kit). Reference the #KPV manual for all system requirements. Utilizing the Kozy Power Vent system will not change facing and finishing requirements or safety barrier requirements from the Standard or Komfort Zone Kit design options.

3.3 Floor Support and Protection

  • Floor protection in front of the fireplace is not required. Combustible material may be used if installing a hearth extension. Consider the thickness of the hearth extension finishing material if building a fireplace platform. The bottom of the fireplace must be level with finished hearth extension for proper fit of a safety barrier.
  • If this appliance is to be installed directly on carpeting, tile, or other combustible material other than wood flooring, this appliance shall be installed on a metal or wood panel extending the full width and depth of the appliance.
  • If the appliance is to be installed above floor level, a solid, continuous platform must be constructed below the appliance.

3.4 Setting the Appliance

  • This section outlines information on setting the appliance in the framed opening and starting the installation process.
  • Decide on your appliance installation option mentioned in Sec- tion 3.2 before setting the appliance. Your framing requirements, clearance to combustibles, and vent configuration will depend upon this decision.

IMPORTANT: If you are using a KZK appliance installation option refer to Section 2.4 for important safety barrier information and Section 4.0 for additional preparation steps that must be completed before setting the appliance in the framed opening.
General Procedure

  1. Frame your opening based on your selected appliance installa- tion option. Refer to Section 3.8 for information for the framed opening of the standard installation option. If you are using a KZK installation option refer to the KZK manual for framing.

  2. Lay out the path for your vent run before installing appliance.

  3. We recommend installing the finishing trim kit. This provides a shadow box around the required safety barrier. Your finishing material will butt up against the finishing trim. Refer to Section 5.2 for installation of finishing trim kit. If you are using the finishing trim kit, this must be installed before the following steps.

  4. Install the nailing flanges on the appliance. Refer to Section 3.6 for assembly and installation. The nailing flanges are where you secure your appliance to the framed opening. The framing will be flush with the appliance when it is installed.

  5. Assemble and install the top stand-off assembly. Refer to Section 3.5 for more information on the top stand-off assembly.
    This stand-off assembly provides the necessary thermal protection of the header.

  6. Place the fireplace inside the framed opening and secure the appliance into the framing. The fireplace will be flush with the framing. If you use the finishing trim kit, the trim kit will stick past the framing as the finishing material will butt up against the trim.

  7. The next steps would involve installing the KZK (if applicable), vent pipe, connect gas line, connect electrical wiring, and finally finishing material.

3.5 Stand-Off Assembly and Installation
WARNING: The top stand-offs provide the 8” (203mm) minimum clearance to the header. Use only non-combustible material in this area for the entire width of the fireplace. DO NOT use wood, sheetrock, et cetera, in this zone.
Top stand-off brackets must be formed and attached prior to positioning fireplace into framed opening.
Note: If installing trim kit assembly #NK48-FTK, please refer to Section 5.2 Finishing Trim Kit Assembly before installing stand-offs.
Note: If installing KZK-045 complete the necessary preparation work before assembling the stand-off assembly.

Installation:

  1. Remove and save (2) screws securing stand-off heat shields and stand-off brackets on top of the fireplace.
  2. Form each top stand-off bracket by bending at perforations, as shown.
  3. Align the holes in the formed top stand-offs with the holes in the fireplace top. Secure with the (2) screws previously removed along with (2) screws located on top of the fireplace.
  4. Form stand-off heat shields as shown. The flange will face up and to the back of the fireplace.
  5. Align the in the stand-off heat shields with the holes in the top stand-off brackets Secure with (8) screws provided in the fireplace components packet.

KOZY HEAT NDK-48-DV Direct Vent Gas Fireplace - Figure
3 3.6 Nailing Flange Assembly and Installation
Note: If installing the Finishing Trim Kit (recommended) please complete that prior to installing the nailing flanges.
CAUTION: Never permanently remove these assemblies from the fireplace. They must be secured regardless of finish material used.

  1. Remove (2) nailing flanges from the right and left side of the fireplace.
  2. Align nailing flange with holes on outside corners of fireplace, with the stand-off flanges on the nailing flanges facing away from the fireplace
  3. Secure the nailing flanges to the fireplace with screws (provided) through the slots in nailing flanges.
  4. Bend perforation on nailing flange until parallel with fireplace face. Do not bend toward fireplace face.
  5. Position framing stud against the small stand-off (located on backside of nailing flange). Secure with nails or screws.

When installed, the nailing flanges provide the minimum 9/16” (14mm) clearance from the sides of the fireplace to framing.KOZY HEAT NDK-48-DV Direct Vent
Gas Fireplace - Figure 3.2

3.7 Clearances to Combustibles

  • See Table 3.1 below for minimum clearances for the standard installation option.
  • See Figure 3.3 on the following pages for typical standard installation options.
  • Unless otherwise noted all clearances / images in this manual are based off of nominal 2” x 4” framing being used.

IMPORTANT: Clearances may change when utilizing the Komfort Zone Kit (Part# KZK-045). Please reference the manual included with that kit. Minimum height of fireplace enclosure increases to 86” (2184mm).

Table 3.1, Minimum Fireplace Clearances to Combustible Material


Minimum height of fireplace enclosure| 80”| 2032mm
Base of the fireplace to ceiling| 80”| 2032mm
Fireplace top to ceiling| 39”| 991mm
From fireplace top stand-off brackets| 0”| 0mm
From fireplace left and right stand-off brackets (nailing flanges)| 0”| 0mm
From fireplace back stand-off brackets| 0”| 0mm
From fireplace corners| 1”| 25mm
From fireplace front| 36”| 914mm
Fireplace sides to adjacent sidewall| 1”| 25mm
Mantel 3/4” (19mm) trim from the top of the fireplace| 9”| 229mm
Mantel 3/4” (19mm) trim from the base of the fireplace| 50”| 1270mm
Mantel 6” (152mm) deep from the top of the fireplace| 12-1/2”| 317mm
Mantel 6” (152mm) deep from the base of the fireplace| 53-1/2”| 1359mm

Minimum Vent System Clearances To Combustibles Inside Minimum Enclosure

Horizontal venting within minimum fireplace enclosure – Top surface of vent pipe| 15-7/8”| 403mm
Horizontal venting within minimum fireplace enclosure – Left, right, and bottom surfaces of vent pipe| 1”| 25mm
Vertical venting within minimum fireplace enclosure – All surfaces| 1”| 25mm

KOZY HEAT NDK-48-DV Direct Vent Gas Fireplace - Figure
3.3 3.8 Wall Enclosure Rough Framing
Note: Unless otherwise noted all clearances / images in this manual are based off of nominal 2” x 4” framing being used.
3.8.1 Rough Framing
WARNING: Provide adequate clearances around air openings into the combustion chamber. Provide adequate clearance in front of the fireplace for barrier removal, component access, gas line installation, service access, etc.
CAUTION: Cold air transfer area. The surround fireplace chase must comply with all clearances as outlined in this manual, and be constructed in compliance with local building codes. Outside walls should be insulated to prevent cold air from entering room.
Rough-in dimensions outlined in FIGURE 3.4 below are the same for all design options and must be followed.

  • Floor protection in front of the fireplace is not required. Combustible material may be used if installing a hearth extension. Consider the thickness of the hearth extension finishing material if building a fireplace platform. The hearth may be flush with the bottom finishing edge of the fireplace.
  • The bottom of the fireplace must be placed directly on a wood or non-combustible surface (not linoleum or carpet). If this appliance is to be installed directly on carpeting, tile, or other combustible material other than wood flooring, this appliance shall be installed on a metal or wood panel extending the full width and depth of the appliance.
  • Framing dimensions should allow for wall covering thickness and fireplace facing materials.
  • If masonry (optional) is to be used, prepare the foundation necessary for the full masonry load. A lintel must be used over the top of the appliance to support the added weight of the masonry construction above the fireplace.

3.8.2 Mounting a Television Above a Fireplace and Television Recess Construction
WARNING: All clearances to venting must be maintained.

  • Mounting a television above a fireplace is a common practice. Mantel depth, ceiling heights, and wall and mantel construction material all affect television surface temperatures. Most television manufacturers specify in their  instructions that a television should not be installed on, near, or above a heat source.
  • If you want a Television above a fireplace it is highly recommended install the fireplace with the KZK installation design option. Refer to Section 3.2 for more information on the KZK design. Install the plenum discharge above the location of a television. This will help distribute heat from below the TV to above the TV. We also recommend the use of a mantel to deflect heat away from the television.
  • Television location rests solely on the homeowner. It is the home owner’s responsibility that the preferred TV mounting and mantel design will not exceed the listed maximum operation temperature of their electronic goods.
  • The allowed TV recess of 4-1/4” (108mm) measures from the front of the nominal 2×4 framing to the backside of the finishing material of the pocket.

KOZY HEAT NDK-48-DV Direct Vent Gas Fireplace - Figure
3.4 3.9 Vent Termination Framing
The following information applies to all standard, and Komfort Zone Kit design options.
If using Kozy Power Vent #KPV, please reference the manual included with the kit.

3.9.1 Vent Termination Location

  • Natural Draft: Exterior vent termination location must be in compliance with section 7.0, TERMINATION LOCATIONS on page 33.
  • Power Vent System: See the #KPV manual that came with the power vent system for termination location requirements

3.9.2 Clearances

  • A minimum of 1” (25mm) clearance on all sides of the vertical vent pipe must be maintained.
    Refer to FIGURE 3.5 below for the following clearances

  • A minimum of 1” (25mm) clearance from the top surface on the horizontal pipe must be maintained.

  • When the fireplace is installed at the minimum chamber height any horizontal venting must have a minimum clearance of 15-7/8” (403mm) from the top of the chamber. The horizontal pipe after the wall pass-through must maintain a 1” (25mm) clearance to combustibles on all surfaces of the pipe.

  • A minimum of 1” (25mm) clearance on the sides and bottom surfaces on the horizontal pipe must be maintained.

KOZY HEAT NDK-48-DV Direct Vent Gas Fireplace - Figure
3.5

3.9.3 Vertical Terminations

  • Follow vent pipe manufacturer’s installation instructions for vertical terminations.
  • Attic insulation shields may be insulated using unfaced insulation products listed as noncombustible per ASTM E 136

3.9.4 Horizontal Terminations
WARNING: Do not recess the vent cap into wall or siding.
IMPORTANT: Horizontal vent sections require 1/4” (6mm) rise for every 12” (305mm) of travel for natural draft applications.
Wall thimble products that comply with the required 1” (25mm) top clearance to combustibles must be installed for all horizontal vent runs that pass through interior or exterior walls. These wall thimble products may be insulated using unfaced insulation products listed as noncombustible per ASTM E 136.
Elbows listed with approved vent systems for this appliance vary in vertical length. Please consult the vent manufacturer’s instructions to determine the elbow dimension used for installation. Adjust the wall pass-through rough opening dimensions to maintain clearance requirements.

3.9.5 Wall Pass Through Framing Instructions
Follow FIGURE 3.6 below for minimum rough-in dimensions.

  1. Measure from floor level of the fireplace to the center of where the vent pipe will penetrate the wall. The dimension in FIGURE 3.6 is used with a Simpson DuraVent elbow.
  2. Cut and frame an opening in the wall to allow the vent system to run level through the wall pass-through.
  3. Follow the vent pipe manufacturer’s installation instructions for natural draft vent installation.

KOZY HEAT NDK-48-DV Direct Vent Gas Fireplace - Figure
3.6

3.10 Outdoor Covered Fireplace Installation
A outdoor covered fireplace installation allows a fireplace to be installed in an outdoor covered area, where the appliance is protected from direct precipitation.
Follow the instructions and illustrations in this section for installation procedures.
3.10.1 Safety Screen Barriers
Hussong Mfg. highly recommends to use black painted safety barriers in outdoor installations. Other screen barriers that incorporate a plated or patina finish are highly susceptible to oxidation and discoloration.

3.10.2 Requirements

  • The continuous insulated building envelope and weatherproof membrane are not to be interrupted by fireplace installation.
  • Fireplace operation is approved from 40°F to 110°F.
  • All wiring connections shall be in accordance with out- door requirements of NECA NFPA 70.
  • All clearances and requirements in your appliance manual must be adhered to.

KOZY HEAT NDK-48-DV Direct Vent Gas Fireplace - Figure
3.7KOZY HEAT NDK-48-DV Direct Vent Gas
Fireplace - Figure 3.8

Heat Management

The Komfort Zone Kit (KZK) offers the option to redistribute radiant heat through plenum(s). This option allows for combus- tible facing materials above the fireplace, heat reduction for a TV above the fireplace, and lower mantel clearances.

  • If installing a Komfort Zone Kit (#KZK-045), the clearance to combustible requirements may be different than the stand- ard dimensions listed in this section. Please reference the manual included with your kit before completing all fireplace framing and other installation considerations.

  • Important: The minimum height of fireplace enclosure increases to 86” (2184mm) when using the #KZK-045..
    The Komfort Zone Kits have specific framing requirements, mantel requirements, and exterior trim dimensions.

  • All minimum required dimensions must be maintained after all finishing materials are installed.

  • The appliance convection plates and insulation must be removed for Komfort Zone Kit installations, as shown in FIGURE 4.1 & Figure 4.2.

Important safety barrier information for the Nordik 48 DV when using a Komfort Zone Kit (#KZK-045). Only use the approved safety barriers in Figure 2.3.

4.1 Appliance Preparation for Komfort Zone Kit
Preparation Instructions

  1. Remove the (13) sheet metal screws that secure the top outer shell assembly. Pull this assembly straight up around the exhaust stack to remove it from the appliance. See the first image in Figure 4.1.
  2. Remove the (4) cover plates where each cover plate is secured with (4) sheet metal screws. See the second image in Figure 4.1. Discard these cover plates.
  3. Remove (3) sheet metal screws from the top of the assembly (see close up in Figure 4.2) and (2) sheet metal screws on the side of the assembly (one screw on each side shown in the second image of Figure 4.1). You are now able to separate the two sections of the top outer shell assembly. Remove and discard both the insulation and the bottom section of the top assembly. Additionally discard the (4) cover plates shown in the second image of Figure 4.1.
  4. Reinstall the top outer shell piece on the appliance with the previously removed (13) sheet metal screws.

KOZY HEAT NDK-48-DV Direct Vent Gas Fireplace - Figure
4.2

Facing and Finishing

5.1 Standard Installation – Facing and Finishing Requirements
WARNING: Maintain all minimum clearances to combustibles from the appliance and vent system.
Utilizing the Kozy Power Vent system will not change mantel, hearth, sidewall, facing and finishing requirements from the standard design option.
Ensure finishing material does not inhibit the installation and removal of the safety barrier (See Section 2.4).
Finishing material cannot obstruct ventilation air.
5.1.1 Combustible Hearth and Mantel Requirements
WARNING: All minimum clearances to combustible material MUST be maintained.

Screen Barriers: NK48-PSF, NK48-FRSF:

  • See the KZK manual (#KZK-045) associated to the Kozy Zone Kit you used with the Nordik 48 DV for hearth, mantel, and sidewall projections.

Screen Barriers: NK48-PSVF, NK48-RSVF, NK48A-MSF, NK48R-MSF

  • Combustible Mantel Projections: As referenced in FIGURE 5.2 the 3/4″ mantel trim can start at 9″ (229mm) above the top finishing edge with a 6″ (152mm) mantel starting at 12-1/2″ (317mm) above the top finishing edge. Mantel projections can increase 1″ (25mm) of depth for every 1″ (25mm) of height starting at the 6″ (152mm) mantel.
  • Combustible Hearth: Combustible flooring can run underneath this appliance which would then allow an unlimited combustible hearth projection. The hearth projection cannot be elevated (vertically) past the base of the fireplace / enclosure floor.
  • Mantel Leg: Follow “Side Combustible Clearance” below. See FIGURE 5.4.
  • Combustible Sidewall Clearance: the adjacent sidewall projection is unlimited and starts at 1” (25mm) from the side of the fireplace. See FIGURE 5.4.

5.1.2 Non-combustible Mantel or Surround Requirements

  • Noncombustible Mantel Projections: As referenced in FIGURE 5.3, the 8” noncombustible mantel projection can start at 41-3/4” (1060mm) from the base of the fireplace. This measurements places the noncombustible mantel flush with the top piece of the
    finishing trim kit (#NK48-FTK) when installed.

  • Noncombustible Surround (top and sides of fireplace opening): As referenced in FIGURE 5.3, the 8” noncombustible surround can be installed flush at the side and top finishing edge of the finishing trim kit.
    The drawing shows a 1” gap from the top and sides of the fireplace which allows for the installation of the finishing trim kit (#NK48-FTK).

  • Follow projection 1” (25mm) up for every 1” (25mm) deeper.

5.1.3 Non-Combustible Zone

  • A 50-1/4” x 8-3/4” non-combustible board is supplied with this fireplace. This board cover more than the minimum non-combustible finishing material requirements. See Figure 5.5, Non-Combustible Finishing Zone for the minimum requirement of noncombustible finishing material.
  • Paper faced gypsum board, commonly known as drywall; including Type X Fire Rated board is not a noncombustible material. This material is not approved for use as a non-combustible material around the fireplace.
  • WonderBoard brand boards are commonly used as a backerboard for tile. WonderBoard backerboard is not a non-combustible material and is not approved for use in the non-combustible material is required around the fireplace.

5.1.4 Finishing Recommendations
NOTE: The surface area above the appliance may be affected by high temperatures emitted from this appliance. To help avoid or reduce the possibility of the sheetrock to crack, Hussong Mfg. recommends the following methods:

  • Ensure the non-combustible material and sheetrock is dry and dust free.
  • For taping and mudding seams, we recommend heat resilient tape, mesh and joint compounds, such as Durabond. Mud must be cured as per manufacturers recommendations.
  • For a painted surface, use a high quality acrylic latex primer and finish coat. Avoid flat or light-colored paints to prevent discoloring.

Disclaimer: Kozy Heat does not guarantee any materials used around the fireplace. Kozy Heat disclaims any and all liability for any damage to finishing materials including warping, discoloring, cracking, peeling or flaking. This also includes any off-gassing or unpleasant smells from materials when they are heated.

5.1.5 Recommended Installation of Marble and other stone materials
Kozy Heat recommends the following statements when using marble, granite, or other stone finishing materials

  • Never use a one-piece marble, granite or natural stone that is cut in a U-shape for finishing material to cover the sides and top areas around the fireplace opening.
  • If you use a one piece U-shaped piece of marble, or stone finishing material the material is susceptible to cracking due to thermal expansion
  • efer to the manufacturer and supplier of your finishing material for use in high heat applications like around a fire- place. Ensure the material can be exposed to temperatures greater than 160°F. Kozy Heat does not assume any liability for discoloring, cracking, or other heat related damage.

KOZY HEAT NDK-48-DV Direct Vent Gas Fireplace - Figure
5.1KOZY HEAT NDK-48-DV Direct Vent Gas
Fireplace - Figure 5.2KOZY HEAT NDK-48-DV
Direct Vent Gas Fireplace - Figure 5.3 Note: Sidewall clearance of 3/4” (19mm) is shown from the side of the fireplace.
Important: The unlimited sidewall projection has a clearance of 0” (0mm) with the side of the finishing trim kit when installed, see Section 5.2. Use of the finishing trim kit is recommended.KOZY HEAT NDK-48-DV Direct Vent Gas
Fireplace - Figure 5.4KOZY HEAT NDK-48-DV
Direct Vent Gas Fireplace - Figure 5.5

5.2 Finishing Trim Kit Assembly
Finishing Trim Kit (#NK48-FTK) is included with the fireplace.
NOTE: The finishing trim kit is highly recommended as it ensures proper fitment of safety screen barrier along with an edge to stop finishing material against.
IMPORTANT: This trim kit assembly must be attached before fireplace installation.
NOTE: The top trim panel must be installed before assembly & installation of the top stand  off bracketsand nailing flanges.

  1. Remove and save (8) screws securing the side heat shields (1 per side). Remove and save (4) screws securing the nailing flanges from the sides of the unit (1 per side).
  2. Install the side finishing trim pieces. Align the holes in the side panels with the holes in the side of the unit as shown below. The side heat shields and nailing flanges will be reinstalled on top of the side trim pieces. Secure with screws previously removed from the heat shields and nailing flanges. Additional information on the nailing flanges are in section 3.6.
  3. Remove the screws securing the top stand-offs. You will need to assemble the top stand-off assembly on top of the finishing trim piece. Refer to section 3.5 for instructions on the top stand-off assembly. Align the holes in the top trim panel with the front holes in the stand-offs and attach to fireplace top. Secure with previously removed screws.
  4. If installed, remove and discard the existing bottom front frame portion. Install the new bottom finishing trim piece, supplied with this kit, into the slots in the bottom corners of the unit. The installation should match the image below.

KOZY HEAT NDK-48-DV Direct Vent Gas Fireplace - Figure
5.6

5.3 Safety Barrier Installations
5.3.1 Overlap Fit – Hanging Installation
Screen Barrier: NK48A-MSF, NK48R-MSF

  1. Center the screen front over the glass frame assembly, allowing the screen front’s mounting brackets to fit inside the air openings.
  2. Align the notched tabs (located on the back) with the slots in the fireplace. Raise slightly and push back to desired position.
  3. Lower the screen front until the notched tabs are firmly in position, verifying the depth accommodates finish material.
    Note: To remove safety screen: lift the screen up and out of slots

5.3.2 Overlap Fit – Hanging Installation with Adjustable Louver (Closed Brackets)
Models #NK48-RSVF, NK48-PSVF, NK48-PSF and #NK48 FRSF
The listed safety barriers are equipped with the louver built into the safety screen face. The hanging brackets  located on the back of screen front are equipped with notches to allow the louver to be adjusted to accommodate facing material thickness.
The safety barrier is shipped with the louver in the first notch position.
To adjust louver position:

  1. Locate the (3) screws on each hanging bracket at the back of the screen front.

  2. Loosen (6) screws on both hanging brackets. This will allow you to bend the bracket outward to adjust the louver to the desired position.
    NOTE: The position of the louver should match with the desired position of the notched tabs needed for your installation. The louver in the first notch position will match with the first notch position in the notched tabs, the louver in the second notch position will match the second notch in the notched tabs, etc.

  3. Adjust the louver to the desired notch in order to accommodate facing material and to cover the control compartment as you see fit. Re-tighten screws on hanging brackets.

  4. Install safety barrier. Center the screen front over the glass frame assembly, allowing the hanging brackets to fit inside the air openings.

  5. Align the notched tabs with the slots in the fireplace.
    Raise slightly and push back to desired position.

  6. Lower the screen front until the notched tabs are firmly in position. Verify the depth accommodates finish material, and the notched tabs position matches the louver notch position.

  7. To remove safety screen: lift the screen up and out of slots.

KOZY HEAT NDK-48-DV Direct Vent Gas Fireplace - Figure
5.7

Gas Line Connection

6.1 Gas Conversion
Note: Stepper Motor sold separately to complete gas conversion
ATTENTION: The conversion shall be carried out in accordance with the requirements of the provincial authorities having jurisdiction and in accordance with the requirements of the ANSI Z223.1 installation code.
This fireplace is manufactured for use with natural gas. Follow the instructions included with the conversion kit if con- verting to propane.
6.2 Gas Line Installation
CAUTION: Installation of the gas line must only be done by a qualified person in accordance with local building codes, if any. If not, follow ANSI 223.1. Commonwealth of Massachusetts installations must be done by a licensed plumber or gas fitter.
NOTE: The appliance and its individual shutoff valve must be disconnected from the gas supply piping system during any pressure testing of that system at pressures in excess of ½ psi (3.5 kPa). For test pressures equal to or less than ½ psi (3.5 kPa), the appliance must be isolated from the gas supply piping system by closing its individual manual shut-off valve.

  • A listed (and Commonwealth of Massachusetts approved) ½” (13mm) tee handle manual shut-off valve and flexible gas connector are to be connected to the ½”(13mm) control valve inlet. If substituting for these components, please consult local codes for compliance.
  • This fireplace is equipped with a 3/8” (10mm) x 18” (457mm) long flexible gas connector and manual shut-off valve.
  • Run gas line into fireplace through gas line hole provided. The gas line should be run to the point of connection where the shut-off valve and flexible gas line will connect. See Figure 2.1, Appliance Dimensions on page 9 for gas line access.
  • Do not run gas line in a manner that would obstruct fan operation.
  • For high altitude installations, consult the local gas distributor or the authority having jurisdiction for proper rating methods.

Table 6.1, Inlet Gas Supply Pressures


| Natural Gas| Propane
Minimum Pressure| 5” WC (1.25kPa)
7” WC (1.74 kPa)
recommended| 11” WC (2.74 kPa)
Maximum Pressure| 10” WC (2.49 kPa)| 13” WC (3.24 kPa)

Termination Locations

7.1 Vertical Vent Cap Termination
Note: Natural Draft Applications only.

  • Refer to Figure 7.1 below for vertical vent terminations clearances.
  • Refer to Figure 7.2 below for clearance between two vertical terminations.

7.1 Vertical Vent Cap Termination
Note: Natural Draft Applications only.

  • Refer to Figure 7.1 below for vertical vent terminations clearances.
  • Refer to Figure 7.2 below for clearance between two vertical terminations.

KOZY HEAT NDK-48-DV Direct Vent Gas Fireplace - Figure
7.1

7.2 Minimum Termination Clearances
Refer to Figure 7.3 and the table below for natural draft vent termination clearance locations.KOZY HEAT NDK-48-DV Direct Vent Gas Fireplace - Figure
7.3

| Canadian Installations| US Installations
---|---|---
A| Clearance above grade, veranda, porch, desk, or balcony.| 12” (30cm)| 12” (30cm)
B| Clearance to window or door that may be opened| 12” (30cm)| 9” (23cm)
C| Clearance to permanently closed window (recommended to prevent condensation on window)| 12” (30cm)| 12” (30cm)
D| Vertical clearance to ventilated soffit located above the terminal within a horizontal distance of 2 feet (61cm) from the edge of the terminal| 24” (61cm)| 24” (61cm)
E| Clearance to unventilated soffit| 12” (30cm)| 12” (30cm)
F| Clearance to outside corner| 0” (0cm)| 0” (0cm)
G H| Clearance to inside corner| 3” (8cm)| 3” (8cm)
Clearance to each side of center line extended above meter/regulator assembly| 3’ (91cm) within a height 15’ (4.5m) above the meter/regulator assembly|

I| Clearance to service regulator vent outlet| 3’ (91cm)|
J| Clearance to non-mechanical air supply inlet to building or the combustion air inlet to any other appliance| 12” (30cm)| 9” (23cm)
K| Clearance to mechanical air supply inlet| 6’ (1.83m)| 3’ (91cm) above [Massachusetts: 10’ (3m) above] if within 10’ (3m) horizontally
L| Clearance above paved sidewalk or paved driveway located on public property| 7’ (2.13m)†|

M| Clearance under veranda, porch deck, or balcony| 12” (30cm)‡| 12” (30cm)
N| Clearance between two horizontal terminations| 12” (30cm)| 12” (30cm)
O| Clearance between two vertical terminations (may be same height)| 12” (30cm)| 12” (30cm)
P| Above furnace exhaust or inlet| 12” (30cm)| 12” (30cm)

  • Clearance in accordance with local installation codes and the requirements of the gas supplier
    †A vent shall not terminate directly above a sidewalk or paved driveway that is located between two single family dwellings and serves both dwellings.
    ‡ Permitted only if veranda, porch, desk, or balcony is fully open on a minimum of two sides beneath the floor
    VINYL SOFFIT, VINYL CEILING, AND VINYL OVERHANG DISCLAIMER: Clearances to heat resistant material (i.e. wood, metal). This does not include vinyl. Hussong Manufac- turing Co., Inc. will not be held responsible for heat damage caused from terminating under vinyl overhangs, vinyl ceilings, or vinyl ventilated/unventilated soffits.

Venting

8.1 Approved Vent Systems
This appliance is equipped for use with a 5” (127mm) exhaust by 8” (203mm) air intake co-axial vent pipe system.
This appliance is approved for use with Kozy Heat Power Vent System #KPV (sold separately). Power Vent configurations and requirements are located in the

KPV manual.

This appliance is approved for use with manufacturers (horizontal and vertical terminations): American Metal Prod- ucts (Ameri-Vent), BDM, ICC, Metal Fab*, Olympia Chimney Supply, Inc., Selkirk, and Simpson DuraVent. See sections 8.1.1 and 8.1.2.
This appliance can be adapted to use 4” diameter aluminum flexible pipe by any listed vent manufacturer when used in combination with an existing minimum 7” ID Class A metal/ masonry chimney. Refer to section 8.6 on page 41 for more information.
Refer to the vent manufacturer’s installation manual for com- plete installation instructions. Installation must conform with the requirements and restrictions specified in this manual.
8.1.1 Approved 5” x 8” Vent Systems

Table 8.1, Approved 5” x 8” Vent Systems


Vent Manufacturer| Vent Cap Part Number
American Metal Products (Ameri-Vent)| 5DHCS
5DHC
5DVC
5D36S
BDM| DVR8-HCP DVR8-HC DVR8-VCLP DVR8-SNK14 DVR8-SNK36
Simpson DuraVent| 58DVA-HC
58DVA-HSCH
58DVA-VCH
58DVA-VC
58DVA-VCS
ICC| TM-5HT TM-5SVT
TM-5ST36
Metal Fab| 5DHT
5DVT
5DST14
5DST36
Olympia Chimney Supply, Inc.| VDV-HC05 VDV-HSC05 VDV-VC05 VDV-VCH05
Vent Manufacturer| Vent Cap Part Number
Selkirk| 5DT-HC
5DT-VT
5DT-VC

8.1.2 Approved 4” x 6-5/8” Vent Systems
This appliance may be reduced from a 5” x 8” to a 4” x 6-5/8” vent system using a vent reducer from an approved vent sys- tem. Refer to the vent pipe manufacturer’s installation manual for more information.

Table 8.2, Approved 4” x 6-5/8” Vent Systems


Vent Manufacturer| Vent Cap Part Number
American Metal Products (Ameri-Vent)| 4DHCS
4DHC
4DVC
4D36S
BDM| DVR6-HCP DVR6-HC DVR6-VCLP DVR6-SNK14
DVR6-SNK36
Simpson DuraVent| 46DVA-HC
46DVA-HSCH
46DVA-VCH
46DVA-VC
46DVA-VCE
46DVA-HTC
ICC| TM-4HT TM-4SVT
TM-4ST36
Kozy Heat| KPV
Metal Fab| 4DHT
4DVT
4DST14
4DST36
Olympia Chimney Supply, Inc.| VDV-HC04
VDV-HSC04 VDV-VC04
Selkirk| 4DT-HC
4DT-VT
4DT-VC

8.2 Venting Requirements
8.3 Vent Restriction
NOTE: Consult the local and national installation codes to assure adequate combustion and ventilation air is availa- ble. Venting requirements apply to both natural gas and propane.

  • Flame height and appearance will vary depending upon venting configuration and the type of fuel used.
  • Provide a means for visually checking the vent con- nection to the appliance after the fireplace is in- stalled.
  • A minimum of 1” (25mm) clearance on all sides of the vertical vent pipe must be maintained. Attic insulation shields may be insulated using unfaced insulation products listed as noncombustible per ASTM E 136.
  • A minimum of 1” (25mm) clearance on the top, sides, and bottom of the horizontal vent pipe must be main- tained. Wall thimble products that comply with the required clearances to combustibles must be installed for all horizontal vent runs that pass through interior or exterior walls. These wall thimble products may be insulated using unfaced insulation products listed as noncombustible per ASTM E 136.
  • The provided vent heat shield is required to be in- stalled in all venting scenarios. See Figure 8.1. The stand off assembly and heat shields are cut away in this image to show the vent heat shield better.
  • The gas appliance cannot be connected to a chimney flue that is serving a separate solid-fuel burning appli- ance.
  • Horizontal vent sections require at least 1/4” (6mm) rise for every 12” (305mm) of travel.

8.3 Vent Restriction

  • Burner flame appearance and characteristics are affected by altitude, fuel quality, venting configuration, and other factors. To achieve desirable flame appearance, the vent exhaust may be restricted by the restrictor plate (included in components packet).
  • The restrictor plate is shipped with all inner rings intact, and when installed, provides the most vent restriction. There are (2) inner rings that can be knocked out. As you knock out and remove an inner ring you have less vent restriction where removing both inner rings you will have the least amount of vent restriction.
  • Follow FIGURE 8.1 for restrictor plate installation before attaching venting or through the baffle if venting is already attached. For vent restriction plate recommendations and adjustments, see section 12.2.3, Vent Re- striction (after installation).

8.4 Use of Flexible Venting Outside the Appliance Enclosure

  • If an approved venting manufacturer offers flexible venting options that can replace rigid vent pipe follow the vent manufacturer’s instructions.
  • Flexible vent pipe can only be used outside of the appliance enclosure.
  • Flexible vent pipe cannot be used to terminate the vent system horizontally or vertically.

KOZY HEAT NDK-48-DV Direct Vent Gas Fireplace - Figure
8.1

8.5 Natural Draft Co-Axial Pipe Installations
8.5.1 Vertical Terminations
Note: Natural Gas and Propane Installations
(i) Minimum / Maximum Vertical Terminations: 3’ (914mm) minimum vertical length / 50’ (15.24m) maximum vertical length + termination cap
(ii) Minimum / Maximum Vertical Terminations with Reducer*: 4” x 6-5/8” reducer + 3’ (914mm) minimum vertical length / 50’ (15.24m) maximum vertical length + termination cap
To use any 45° elbow for vertical terminations with a reducer, the total minimum vertical vent run must be 10’ (3.05m). A total of (4) 45° elbows may be used. No 90° elbows are allowed. For every 45° elbow used, 18” (457mm) must be subtracted from maximum
venting allowed.

KOZY HEAT NDK-48-DV Direct Vent Gas Fireplace - Figure
8.3

8.5.2 Horizontal Terminations
Note: Natural Gas and Propane Installations
IMPORTANT: Horizontal vent sections require 1/4” (6mm) of rise for every 12” (305mm) of travel.
(i) Minimum 12” Vertical Vent Pipe/ Minimum Horizontal: 12” (305mm) vertical vent pipe + 90° horizontal elbow + termination cap
NOTE: If you are installing the fireplace at this vent option and it is converted to Propane adjust the left and right burner venturi openings to to 3/8” (10mm)
(i) Minimum 12” Vertical Vent Pipe / Maximum Horizontal: 12” (305mm) vertical vent pipe + 90° horizontal elbow + 24” (610mm) maximum horizontal + termination cap
NOTE: If you are installing the fireplace at this vent option and it is converted to Propane adjust the left and right burner venturi openings to to 3/8” (10mm)
(ii) Minimum 24” Vertical Vent Pipe / Minimum Horizontal: 24” (610mm) vertical vent pipe + 90° horizontal elbow + termination cap
(ii) Minimum 24” Vertical Vent Pipe / Maximum Horizontal: 24” (610mm) vertical vent pipe + 90° horizontal elbow + 8’ (2.44m) maximum horizontal + termination cap
(iii) Minimum 36” Vertical Vent Pipe / Minimum Horizontal: 36” (914mm) vertical vent pipe + 90° horizontal elbow + termination cap
(iii) Minimum 36” Vertical Vent Pipe / Maximum Horizontal: 36” (914mm) vertical vent pipe + 90° horizontal elbow + 12’ (3.66m) maximum horizontal + termination cap
(iv) Maximum 25’ Vertical / Minimum Horizontal:  25’ (7.62m) maximum vertical vent length + 90° horizon- tal elbow + termination cap
(iv) Maximum 25’ Vertical / Maximum Horizontal: 25’ (7.62m) maximum vertical + 90° horizontal elbow + 25’ (7.62m) maximum horizontal + termination cap
(v) Basement Install – Minimum Vertical / Maximum Horizon- tal 36” (914mm) minimum 5” x 8” vertical vent pipe + 4” x 6- 5/8” reducer + 90° horizontal elbow + 24” (610mm) maximum horizontal + termination cap
NOTE: If you are installing the fireplace at this vent option and it is converted to Propane adjust the left and right burner venturi openings to to 3/8” (10mm)KOZY HEAT NDK-48-DV Direct Vent Gas Fireplace - Figure
8.4KOZY HEAT NDK-48-DV Direct Vent Gas
Fireplace - Figure 8.6

8.5.3 Combination Venting
Note: Natural Gas and Propane Installations Vent termination must be within the shaded area in FIGURE 8.7.

  • 25’ (7.62m) maximum vertical rise + 25’ (7.62m) maximum horizontal run = 50’ (15.2m) of total length
  • Maximum of (5) 90° elbows. For each additional 90° elbow used after the first elbow, 3’ (914mm) must be subtracted from maximum venting allowed.
  • (2) 45° degree elbows may be used in place of (1) 90° elbow. For each 45° elbow used, 18” (457mm) must be subtracted from maximum venting allowed.

KOZY HEAT NDK-48-DV Direct Vent Gas Fireplace - Figure
8.7

8.6 Class A Chimney / Masonry Chimney Conversion

This appliance is approved to be adapted for Class A/ Masonry Chimney conversion with kits utilizing a 4” (102mm) flexible exhaust by any vent manufacturers listed in section 8.1, APPROVED VENT SYSTEMS.
Before conversion, have the existing installation inspected by a qualified chimney sweep or professional installer. The existing chimney system must be in serviceable condition, and functionally sound.
Before proceeding with following installations, check with local building jurisdiction to verify this type of   installation is allowed in your area.
Follow Figure 8.8 for allowable venting configura- tions for installation in existing through-the-ceiling, Class A/Masonry chimney. Route the exhaust gases and intake air through the existing Class A/Masonry chimney.
The gas appliance cannot be connected to a chimney flue that is serving a separate solid-fuel burning appliance.

8.6.1 4” Flex Pipe Venting Configurations
IMPORTANT: Horizontal vent sections require at least 1/4” (6mm) rise for every 12” (305mm) of travel.
IMPORTANT: The vent heat shield assembly must be installed when incorporating minimum horizontal venting off the top of the appliance.
IMPORTANT: Care should be taken when installing flexible pipe to avoid a tight bend that may cause abrasion or damage to the flexible pipe.
The vent option listed below allow for a minimum of 0” (0mm) to a maximum of 24” (610mm) horizontal run using rigid or flexible pipe.
(1) Minimum / Maximum Vertical Terminations 4” x 6-5/8” reducer + retro connector + 10’ (3.05m) minimum length of 4” aluminum flexible pipe / 50’ (15.24m) maximum length of 4” aluminum flexible pipe + top adapter + termination cap KOZY HEAT NDK-48-DV Direct Vent Gas Fireplace - Figure
8.8

Fireplace Setup

9.1 Glass Frame Assembly
WARNING: Do not operate this fireplace with the glass removed, cracked, or  broken. Replacement of the glass assembly, should be done by a licensed or qualified ervice erson.
9.1.1 Remove Glass Frame Assembly
WARNING: Do not remove the glass assembly when hot.

  1. Remove safety barrier..
  2. Locate (2) spring-loaded latches securing the glass as- sembly at the top of the firebox.
  3. Pull the spring-loaded latches out and up to release the top of the glass assembly.
  4. Tilt the top glass assembly towards you and lift off of the (2) support rails located at the bottom of the firebox.

9.1.2 Install Glass Frame Assembly

  1. Tilt the top of the glass frame assembly as shown in Figure 9.1. Align the slots on bottom of the glass assembly on top of the rails at the bottom of the firebox while tilting the top of the glass assembly into position.
  2. Pull the spring-loaded latches out and up to secure the top of glass to the top of the fireplace.
  3. Reinstall safety barrier.KOZY HEAT NDK-48-DV Direct Vent Gas Fireplace - Figure 9.1

9.2 Bottom Frame Removal and Installation
To access the control module housing, the bottom frame will need to be removed. It must be reinstalled after servicing to maintain clearances.

  1. Remove safety barrier.
  2. Pull the bottom frame piece up and out to gain access below the fireplace. See Figure 9.2.KOZY HEAT NDK-48-DV Direct Vent Gas Fireplace - Figure 9.2

9.3 Light Kit
ATTENTION: If converting to propane do so now before installing any light kit components. Follow instructions included with the conversion kit (sold separately).
CAUTION: Disconnect all electric power from fireplace before performing any of these tasks.
NOTE: To avoid damage and prolong the life of halogen bulbs, never touch with bare hands. Always use a soft cloth when handling.
ATTENTION: If converting to propane do so now before installing any light kit components. Follow instructions included with the conversion kit (sold separately).
CAUTION: Disconnect all electric power from fireplace before performing any of these tasks.
NOTE: To avoid damage and prolong the life of halogen bulbs, never touch with bare hands. Always use a soft cloth when handling.

9.3.1 Install Light Bulbs – Front Bottom Light Kit
Note: The front bottom light kit will not have the halogen bulb installed from the factory. Follow the instruction below for initial installation as well as bulb replacement.

  1. Remove the safety barrier and glass frame assembly.
  2. Remove log set, crushed glass media, and lava rock (if installed).
  3. Remove and retain (4) screws from the log rack/ember media tray. Lift tray up and out of firebox. See Figure 9.3.
  4. nstall (5) halogen bulbs (included in components packet) into the lamp bases.
  5. Reinstall log rack/media tray using screws previously removed.
  6. Reinstall all components previously removed.

9.3.2 Install Light Bulbs – Back Bottom Light Kit
• Halogen bulb is preinstalled from the factory. See instructions below for bulb replacement.

  1. Remove the safety barrier and glass frame assembly.

  2. Remove log set, crushed glass media, and lava rock (if in- stalled).

  3. Remove and retain (4) screws from the log rack/media tray. Lift tray up and out of firebox. See Figure 9.3.

  4. Loosen (2) 7/16” nuts for left and right burners. Remove burners. See Figure 9.4.

  5. Remove and retain (4) screws from the back media tray.
    Remove media tray. See Figure 9.5.

  6. Install (3) halogen bulbs (included in components packet) into the lamp base.

  7. Reinstall all components previously removed.

9.3.3 Install Light Bulbs – Top Light Kit
Note: The top light kit will have the halogen bulb installed from the factory. Follow the instruction below for bulb replacement.

  1. Remove the safety barrier and glass frame assembly.
  2. Remove the light kit cover and roped glass (4) screws.
  3. Install (1) halogen bulb into the lamp base.
  4. Reinstall all components previously removed.

KOZY HEAT NDK-48-DV Direct Vent Gas Fireplace - Figure
9.4

9.4 NK48-500 Log Set Installation
NOTE: Log numbers are located on the bottom or side of each log. Refer to the following instructions and illustration for proper placement. Your components may look different than the ones shown.
CAUTION: Do not place logs directly over burner port holes. Improper log placement may affect flame appearance and may cause excessive soot to build upon the glass.

  • If converting to propane, complete the conversion before installing the log set. Follow the conversion instructions included with the kit.
  • If installing a panel set, complete installation of panel set before log installation
  • Install all light bulbs into the front ember bed light kit before log installation.
    1. Remove valance from fireplace. Remove and retain (4) screws from the log rack/ember media tray. Lift tray up and out of firebox. See Figure 9.3. Loosen (2) 7/16” nuts for left and right burners. Remove the (2) sheet metal screws that secure the left and right burners to the rear burner. Remove burners. See Figure 9.4.
    2. Place log #N48-1 on the far left and log #N48-2 on the far right. There are corresponding pins on floor that hold these in position(pins not shown). Logs must lie flat on media tray. Failure to do so will negatively affect the flame
    3. Make sure the light bulbs for the rear light kit are installed. Install the crushed media on the rear light kit. Place log #N48-5 and log #N48-6 on top of the crushed glass as shown.
    4. Install klinkers on rear burner as shown. Do not cover burner ports.KOZY
HEAT NDK-48-DV Direct Vent Gas Fireplace - Figure 9.7

5. Install log #N48-3. Position log #N48-3 so it sits on top of log #N48-1 and the metal platform above the air chute opening as shown. Secure the log on the studs. See Figure 9.8.
6. Install log #N48-4. Position log #N48-4 so it sits on top of log #N48-2 and the metal platform above the air chute opening as shown. Secure the log on the studs. See Figure 9.8.
7. Install the left and right burner assemblies. Slide each burner over the burner orifice. Tighten the flange nut on the bracket at the bottom of the burner tube. Secure each burner with (1) sheet metal screw through the tab into the rear burner. See Figure
9.14.
8. Ensure light bulbs are installed in the front light kit. Install the log rack / ember bed media tray. Secure with (4) sheet metal screws. Install the crushed glass on top of the media tray. Install the lava rock on the solid media section to the left and right of the media tray.
9. Install the logs #N48-7 and #N48-8 on the left and right burner assemblies via the PEM studs. Shown in Figure 9.9.
10. Install logs #N48-9 thru #N48-13 as shown in Figure 9.10.
11. Use a stiff or steel bristle brush to distribute rockwool embers onto the burners and logs.

KOZY HEAT NDK-48-DV Direct Vent Gas Fireplace - Figure
9.8KOZY HEAT NDK-48-DV Direct Vent Gas
Fireplace - Figure 9.10

9.4.1 Rockwool Installation

  • After installation of the log set you can apply rockwool across logs N48-7, N48-8, left & right burner screen and rear burner.
  • Use a small brush to brush the rockwool across the locations referenced above. Rockwool will provide a glow as the fireplace operates.
  • DO NOT place the rockwool in excessively large pieces that would block large sections of burner ports. Excessive use of rockwool that blocks burner porting can create undesired flame characteristics and/or a possible delayed ignition.
  • Make sure no rockwool is blocking the pilot flame or around the pilot assembly.

KOZY HEAT NDK-48-DV Direct Vent Gas Fireplace - Figure
9.11

9.5 Control Board Removal and Installation
WARNING: If burner and/or pilot have been burning, use appropriate protection to avoid burns or damage to personal property before removing any components.
DO NOT OPERATE THIS APPLIANCE WITHOUT THE SEALING GASKET (LOCATED UNDER THE CONTROL BOARD) IN PLACE. IF GASKETING IS DAMAGED, IT MUST BE REPLACED.
CAUTION: Check all connections for leaks with soapy water, whether field or factory made.
9.6.1 Control Board Removal

  1. Disconnect electrical power. Locate the main shut-off valve upstream of the appliance connector and close valve.
  2. Remove the (4) screws securing the log rack/media tray.
  3. Remove front light kit (2) screws. Loosen (2) 7/16” nuts to remove left and right burner assemblies.
  4. Remove rear burner assembly (2) screws and remove rear burner assembly.
  5. Remove the (4) screws that secure the back media tray that covers the back bottom light kit.
  6. Remove the (8) screws securing the control board. Lift the control board out of the firebox, being careful not to damage the sealing gasket underneath.
  7. Pull out control board out to reveal gas line to disconnect the gas line flex tube from fireplace valve.

9.6.2 Control Board Installation

  1. Place control board in the firebox, aligning the holes in the control board with the holes in the firebox bottom. VERIFY SEALING GASKET IS IN PLACE.
  2. Secure the control board to the firebox using (8) screws previously removed.
  3. Reinstall the back media tray using the (4) screws previously removed.
  4. Reinstall the rear burner assembly using the (2) screws previously removed.
  5. Reinstall left burner assembly pushing it towards center until it stops against the rear burner, then secure. Repeat this process with the right burner assembly. Tighten previously loosened burner nuts.
  6. Reinstall front light kit with (2) screws previously removed.
  7. Reinstall log rack/media tray with the (4) screws pre- viously removed.
  8. Reconnect electrical power.
  9. Verify proper log placement, operation of fireplace, and any electrical components.KOZY HEAT NDK-48-DV Direct Vent Gas Fireplace - Figure 9.14KOZY HEAT NDK-48-DV Direct Vent Gas Fireplace - Figure 9.17

Electrical Information

WARNING: Do not use this fireplace if any part has been under water. Immediately call a qualified service technician to inspect this appliance and to replace any part of the control system and any gas control which has been under water.
WARNING – Electrical  rounding Instructions: This appliance is  equipped with a three-prong (grounding) plug for your protection against shock hazard and should be plugged directly into a properly grounded three-prong receptacle. Do not cut or remove the
grounding prong from this plug
10.1 Electrical Specifications
This appliance, when installed, must be electrically grounded in accordance with local codes, or in the absence of local codes, with the National Electrical Code, ANSI/NFPA 70, or the Canadian Electrical Code, CSA C22.1.

10.2 Wiring Requirements

  • The system requires 120 VAC of electricity and/or batteies to operate.
  • Using the battery backup will operate flame modulationof the burner.
  • Fan and light components will not function on battery back up power

Figure 10.1 – 10.3
Note: Spade connectors are labeled “M” for male connectors and “F” for female connectors. KOZY HEAT NDK-48-DV Direct Vent Gas Fireplace - Figure
9.18

  • Figure 10.2 shows a close up of the wiring diagram. This figure shows the main power cord, fan kit, top light kit, and ember bed light kit.KOZY HEAT NDK-48-DV Direct Vent Gas Fireplace - Figure 10.2
  • Figure 10.3 shows a close up of the wiring diagram. This figure shows the pilot assembly, on / off rocker switch, battery back -up, valve, and SW1 Remote Learn Button.KOZY HEAT NDK-48-DV Direct Vent Gas Fireplace - Figure 10.3

Operating Instructions

FOR YOUR SAFETY READ BEFORE OPERATING
WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury, or loss of life.

A. This appliance is equipped with an ignition device which automatically lights the pilot. Do not try to light the pilot by hand.
B. BEFORE OPERATING smell around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor.

WHAT TO DO IF YOU SMELL GAS

  • Donottry to light any appliance

  • Do not touch any electric switch; do not use any phone in your building.

  • Immediately call your gas supplier from a neighbor’s phone.
    Follow the gas supplier’s instructions.

  • If you cannot reach your gas supplier, call the fire department.
    C. Use only your hand to turn the gas contro! manual valve. Never use tools. If the valve will not turn by hand, do not try to repair it; call a qualified service technician. Force or attempted repair may result in a fire or explosion.
    D. Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control that has been under water.

WARNING

Do not operate appliance with the glass front removed, cracked, or broken. Replacement of the glass should be done by a licensed or qualified service person.
Under no circumstances should any solid fuel (wood, coal, paper, cardboard, etc.) be used in this appliance.
Children and adults should be alerted to the hazards of high surface ternperature and should stay away to avoid bums or clothing ignition.
CAUTION

Clothing or other flammable material should not be placed on or near the appliance.
Young children should be carefully supervised when they are in the same room as the appliance. Toddlers, young children and others may be susceptible to accidental contact bums. A physical barrier is recommended if there are at risk individuals in the house. To restrict access to a fireplace or stove, install an adjustable safety gate to keep toddlers, young children and other at risk individuals out of the room and away from hot surfaces.

OPERATINGINSTRUCTIONS

  1. STOP! Read all the safety information above on this page.

  2. Press the wireless remote OFF button.

  3. Tum off all electric power to the appliance.

  4. This appliance is equipped with an ignition device which automatically lights the pilot. Do not try to light the pilot by hand.

  5. Locate the manual valve installed by your qualified service technician.

  6. Tum the manual valve clockwise to the OFF position.

  7. Wait five (5) minutes to clear out any gas Then, smell for gas, including near the floor. If you smell gas, STOP!
    Follow B’ in the safety information above. If you do not smell gas, go to the next step.

  8. Tum the manual valve counterclockwise to the ON position.

  9. Turn on all electric power to the appliance.

  10. Press the wireless remote ON button.

  11. If the appliance will not operate, follow the instructions, “To Tur Off Gas To Appliance’ and call your service technician or gas supplier.

TO TURN OFF GAS TO APPLIANCE

  1. Press the wireless remote OFF button.
  2. Tum off all electric power to the appliance if service is to be performed.
  3. Locate the manual valve installed by your qualified service technician.
  4. Tumthe manual valve dockwise to OFF position.

NOTE
When this fireplace is initially lit, condensation will appear on the glass. This is normal in all gas fireplaces and will disappear after several minutes. A paint smell will occur during the first few hours of burning. It is recommended to leave the fan off during this period to help speed the paint curing process.
This fireplace may produce noises of varying degree as it heats and cools due to metal expansion and contraction. This is normal, and does not affect the performance or longevity of the fireplace.

11.1 Setup Proflame 2 IFC Module

  1. Set the main ON/OFF rocker switch in the OFF position.
  2. Install (4) AA batteries (not included) into backup battery holder on the control module.
  3. Install (3) AAA batteries (included in the components packet) in the remote control battery bay, located at the base of the remote.
  4. Connect the IFC Module to an AC power supply.

11.2 Initialize the Control System
IMPORTANT: Remove all packaging and combustible material from the firebox before initializing the control system.
NOTE: Performing the next steps will initiate pilot start- up in manual mode, where the pilot igniter will spark repeatedly. The pilot will ignite if gas is supplied to the fireplace.

  1. To access the ON/OFF toggle switch and remote learn button on, remove the safety barrier screen by lifting up and out of its slots.
  2. Remove the bottom frame piece (See Section 9.2). Locate the remote sync button by sliding out the control module.
  3. Press the remote sync button. The IFC module will BEEP (3) times and illuminate an amber LED. This indicates the receiver is ready to synchronize with the transmitter.
  4. Within (5) seconds, push the ON/OFF button on the remote control. The receiver will BEEP (4) times to indicate the transmitter’s command is accepted, and is set to the transmitter’s particular code. The pilot will automatically ignite.
  5. Press the remote control ON/OFF button again. The pilot will extinguish, confirming the remote control command. The control system is now initialized.
  6. Set the main ON/OFF rocker switch to ON position for remote control operation of the main burner and fireplace features. Reinstall safety barrier screen.

11.3 Reset the System for Manual Operation

  1. Access the toggle switch and remote learn button on the left side of the unit by removing the safety barrier screen by lifting up and out of its slots.
  2. Remove the bottom frame piece (See Section 9.2). Locate the remote sync button by sliding out the control module.
  3. Set the ON/OFF rocker switch to OFF position.
  4. Press and hold the remote sync button until it emits (3) beeps and an amber LED is illuminated.
  5. Within (5) seconds, press the remote sync button again.
    This will close synchronization with the remote control.
    The pilot will automatically light.
    • Turn the main burner ON by setting the ON/OFF switch in ON position. The main burner will only operate on HI.
    • Turn the main burner OFF by setting the ON/OFF switch in the OFF position. The pilot will remain lit even if burner is turned off, provided CPI mode is turned on.

11.4 Automatic Safety Turn-off

  • This system will execute an automatic turn OFF command for approximately (5) seconds within (24) hours of a continued pilot flame ignition to perform a safety check. This allows the system to verify correct safety functions.
  • After the turn OFF sequence is completed, the IFC module will re-execute the latest command.

11.5 Backup Battery Operation
This appliance will operate on the backup battery pack when electric power is interrupted, or in a power outage. During the power outage, the appliance burner and flame height adjust- ment will function. The fan and accent light kit will not func- tion.

  • The lifespan of the backup batteries depend on various factors, such as the quality of the batteries, number of ignitions, etc.
  • When the backup battery pack is low, the IFC module will emit a double-beep while receiving an ON/OFF command. No commands will be accepted after this alert until the back up batteries are replaced. Once replaced, the IFC module will emit a ‘beep’ as soon as it is powered.

11.6 Control System 7 Day Timeout

  • If you have your Proflame 2 system set to CPI (continuous pilot ignition) with 7 consecutive days without ignition of the main burner, the pilot will turnoff. This a standard safety feature of the SIT Proflame2 system.
  • Once you turn CPI on, the 7 day timer will start. If at any time during the following 7 days your main burner ignites, it will reset the timer back to 7 days.
  • See section 11.9.3 PILOT IGNITION SELECTION (page 55) for more information.

How to check if your system is set to CPI:
The LCD screen will display the snowflake icon.
To select the preferred pilot ignition feature,

  1. With the system in the OFF position, press the mode key to index the CPI mode icon.
  2. Press the up arrow key to activate CPI.
  3. Press the down arrow key to return to IPI. A single ‘beep’ will confirm reception of the command.

To Turn ON the appliance

  1. With the system in the OFF position, press the remote control ON/OFF key to turn ON the appliance.
    A single ‘beep’ will emit from the IFC module to confirm reception of the command.

The LCD screen will display all active icons, and the IFC module will start the ignition sequence.

11.7 IFC Module Ignition Sequence
The IFC module will try (2) times for ignition, each lasting approximately (60) seconds, with approximately (35) sec- onds between each attempt.

  1. With the system in OFF position, press the remote control ON/OFF key. Approximately (4) seconds after this key is depressed, the IFC module will generate sparks to the pilot hood.
  2. First ignition attempt will generate sparks for (60) seconds.
  3. If there is no flame ignition (rectification) within the (60) second time frame, the IFC module will stop generating sparks for approximately (35) seconds.
  4. After (35) seconds of wait time, the IFC module will generate sparks for another (60) seconds for the second ignition attempt.
  5. If there is no positive rectification after (60) seconds, the IFC module will go into a lock out. The red LED will blink (3) times, in intervals, until the system is reset.

11.7.1 Reset IFC Module after Lockout
11.7.1.1 ON/OFF Rocker Switch

  1. Set the ON/OFF rocker switch to the OFF position.
  2. After approximately (2) seconds, move the switch to the ON position. The ignition sequence will start again.

11.7.1.2 Remote Control ON/OFF Key

  1. Press the remote control ON/OFF key to turn the system OFF.
  2. After approximately (2) seconds, press the ON/OFF key again. The ignition sequence will start again.

11.7.1.3 Cycling Flame

  1. Press the remote control down arrow key during flame adjustment mode to reduce the flame to OFF (indicated by OFF displayed on the LCD screen).
  2. After approximately (2) seconds, press the up arrow key. The ignition sequence will start again.

11.8 Additional Diagnostic Information
Low Battery Condition (<4V) Remote Control:

  • Battery Icon will appear on LCD remote control dis- play.
  • Replace batteries.

Low Battery Condition ( <4V) Battery Backup:

  • The red LED Indicator will blink (1) time in intervals.
  • A low double-beep emits from the IFC control module when it receives an ON/OFF command from the remote control.
  • Replace Batteries.

Pilot Flame Error Condition:

  • Red LED Indicator will blink (2) times in intervals. Con tact your dealer if this occurs.

System Lock Out Condition:

  • Red LED Indicator will blink (3) times in intervals.
  • Verify gas is turned on.
  • Verify sensor is not shorted.
  • Follow section 11.2, INITIALIZE THE CONTROL SYSTEM on page 52.

11.9 Remote Control Operation

KOZY HEAT NDK-48-DV Direct Vent Gas Fireplace - Figure
11.1

11.9.1 Temperature Display

  1. With the system in the OFF position, simultaneously press the thermostat key and the mode key to change degrees from °F to °C
  2. Visually check the LCD screen to verify either °F or °C is displayed on the right side of the room temperature display.

KOZY HEAT NDK-48-DV Direct Vent Gas Fireplace - Figure
11.2

11.9.2 Key Lock
This function locks the keys to avoid unsupervised opera- tion. Once activated, a lock icon will appear on the LCD screen.

  1. Simultaneously press the mode key and the up arrow key to activate or deactivate this function.

11.9.3 Pilot Ignition Selection (IPI/CPI)
This system has the option of a continuous (standing) pilot. This features allows the system to change from a spark-to-pilot system to the standing pilot option. The standing pilot will keep the firebox warm and establish a draft in the vent, which allows the main burner to ignitewith less air-flow disruption.
When the system is OFF, the LCD screen will display the snowflake icon during the setup of either IPI or CPI modeTo select the preferred pilot ignition feature,

  1. With the system in the OFF position, press the modekey to index the CPI mode icon.
  2. Press the up arrow key to activate CPI.
  3. Press the down arrow key to return to IPI. A single ‘beep’ will confirm reception of the command.

When the system is ON,
IPI mode: LCD screen will not display the snowflake icon
CPI mode: LCD screen will display the snowflake icon KOZY HEAT NDK-48-DV
Direct Vent Gas Fireplace - Figure 11.4

11.9.4 Turn ON the Appliance

  1. With the system in the OFF position, press the remote control ON/OFF key to turn ON the appliance. A single ‘beep’ will emit from the IFC module to confirm reception of the command.

The LCD screen will display all active icons, and the IFC module will start the ignition sequence.
11.9.5 Turn OFF the appliance

  1. With the system in the OFF position, press the remote control ON/OFF key to turn ON the appliance. A single ‘beep’ will emit from the IFC module to confirm reception of the command.

The LCD screen will only display the room temperature and its icon, and the IFC module will turn off the main burner.

11.9.6 Remote Control Flame Adjustment
This control system has (6) flame levels. If the smart thermostat operation is activated, then the manual adjustment of the flame height will be disabled.

  1. Verify the system is in the ON position and the flame level is set at maximum.
  2. Press the down arrow key once to reduce flame height by one level until the flame is turned off.
  3. Press the up arrow key once to increase flame height by one step. If the up arrow key is pressed while the system is on, but the flame is off, the flame will ignite on HI.
  4. A single ‘beep’ will confirm reception of the command.

KOZY HEAT NDK-48-DV Direct Vent Gas Fireplace - Figure
11.5

11.9.6.1 Deactivate Flame Modulation

  1. Verify all (3) AAA batteries are installed in the remote control battery bay.
  2. Remove (1) AAA battery.
  3. Press and hold the on/off key and the mode key at the same time.
  4. Reinsert (1) AAA battery.
  5. While still holding the on/off key, let go of ONLY the mode key.
  6. Index over to the flame graphic on the LCD screen to edit. Use the up or down arrow key to choose ‘SEL’ or ‘CLR’. “SEL” means flame modulation is turned on and “CLR” means flame modulation is turned off.KOZY HEAT NDK-48-DV Direct Vent Gas Fireplace - Figure 11.6

11.9.7 Remote Control Thermostat Operation
11.9.7.1 Room Thermostat
The remote control can operate as a room thermostat.
The thermostat can be set to a desired temperature to control a room’s comfort level. To activate this function,

  1. Press the thermostat key. The LCD screen will display a temperature bulb graphic, the room temperature and set temperature.
  2. To adjust the set temperature, press the up or down arrow keys until the desired temperature is displayed on the LCD screen.KOZY HEAT NDK-48-DV Direct Vent Gas Fireplace - Figure 11.7

11.9.7.2 Smart Thermostat
The smart thermostat function will adjust the flame height based on the set temperature and the actual room temperature. The smart thermostat function automatically adjusts the flame down when the room temperature reaches the set point. To activate this
function,

  1. Press the thermostat key until the ‘SMART’ appears on LCD screen on the right side of the temperature bulb graphic.
  2. To adjust the set temperature, press the up or down arrow keys until the desired temperature is displayed on the LCD screen.

KOZY HEAT NDK-48-DV Direct Vent Gas Fireplace - Figure
11.8

11.9.7.3 Deactivate Remote Control Thermostat Operation
The thermostat operation function can be deactivated. The remote control will still operate the main burner on and off, and function flame, fan, and light modulation. To deactivate this function,

  1. Verify all (3) AAA batteries are installed in the remote control.
  2. Remove (1) AAA battery.
  3. While reinserting the battery, push and hold the thermo- stat key. You will see “CLR” across the screen. This means the thermostat function is turned off. The temperature bulb graphic will not be displayed on the LCD screen.
    • To reactivate remote thermostat operation, follow the same key sequence procedure above. The screen will then say “SEL” which means the thermostat function is turned on. The temperature bulb graphic will reappear on the LCD screen.

KOZY HEAT NDK-48-DV Direct Vent Gas Fireplace - Figure
11.9

11.9.8 Fan Speed Control
Fan speed can be adjusted through (6) speeds. To activate this function,

  1. Press the mode key to index to the fan control icon.
  2. Press the up or down arrow keys to turn on, off, or to adjust fan speed.

Thermostat mode: Fan(s) have a (5) minute delay time when the fireplace is lit. This allows time for heat to build in fireplace before fan operation. The fan will continue to operate for approximately (12) minutes after the fireplace has been turned off.
Manual mode: Fan(s) will operate at previous setting.
There is no delay in start up or stop time.KOZY HEAT NDK-48-DV Direct Vent
Gas Fireplace - Figure 11.10

11.9.8.1 Deactivation Fan Speed Control
Fan speed can be adjusted through (6) speeds. To activate thisfunction,

  1. Verify all (3) AAA batteries are installed in the remote control battery bay.
  2. Remove (1) AAA battery.
  3. Press and hold the on/off key and the mode key at the same time.
  4. Reinsert (1) AAA battery.
  5. While still holding the on/off key, let go of ONLY the mode key.
  6. Index over to the fan control icon on the LCD screen to edit. Use the up or down arrow key to choose ‘SEL’ or ‘CLR’.

KOZY HEAT NDK-48-DV Direct Vent Gas Fireplace - Figure
11.11

11.9.9 Top Accent Light Kit
The top light intensity can be adjusted through (6) levels.

  1. Press the mode key to index to the light icon.
  2. Press the up or down arrow keys to adjust the intensity level.
  3. A single ‘beep’ will confirm reception of the command.

KOZY HEAT NDK-48-DV Direct Vent Gas Fireplace - Figure
11.12

11.9.9.1 Deactivation Light Kit Modulation

  1. Verify all (3) AAA batteries are installed in the remote control battery bay.
  2. Remove (1) AAA battery.
  3. Press and hold the on/off key and the mode key at the same time.
  4. Reinsert (1) AAA battery.
  5. While still holding the on/off key, let go of ONLY the mode key.
  6. Index over to the bulb graphic on the LCD screen to edit. Use the up or down arrow key to choose ‘SEL’ or ‘CLR’.

KOZY HEAT NDK-48-DV Direct Vent Gas Fireplace - Figure
11.13

11.9.10 Activate Ember Bed Light Kit (auxiliary)
The auxiliary function controls ON/OFF function the ember bed light kit. To activate this function,

  1. Verify all (3) AAA batteries are installed in the remote control battery bay.
  2. Remove (1) AAA battery.
  3. Press and hold the on/off key and the mode key at the same time.
  4. Reinsert (1) AAA battery.
  5. While still holding the on/off key, let go of ONLY the mode key.6. Index over to the hand graphic on the LCD screen to edit. Use the up or down arrow key to choose ‘SEL’ or ‘CLR’.

To turn on the Ember Bed Light Kit

  1. Press the mode key to index to the AUX icon.
  2. Press the up arrow key to turn the ember bed light kit ON.
  3. Press the down arrow key to turn the ember bed light kit OFF.
  4. A single ‘beep’ will confirm reception of the command.

KOZY HEAT NDK-48-DV Direct Vent Gas Fireplace - Figure
11.14

11.9.10.1 Adjust Ember Bed Light Kit Intensity (after turning “ON”)
The ember bed light kit intensity can be adjusted by using the ember bed light kit modulator knob located underneath the firebox (FIGURE 11.15). To adjust,

  1. Remove the safety barrier screen by lifting the screen up and out of the slots.
  2. Turn the knob counterclockwise to decrease the light intensity.
  3. Turn the knob clockwise to increase the light intensity.
  4. Reinstall safety barrier screen when finished.

KOZY HEAT NDK-48-DV Direct Vent Gas Fireplace - Figure
11.15

11.9.10.2 Deactivation AUX (Ember Bed Light Kit)

  1. Verify all (3) AAA batteries are installed in the remote control battery bay.
  2. Remove (1) AAA battery.
  3. Press and hold the on/off key and the mode key at the same time.
  4. Reinsert (1) AAA battery.
  5. While still holding the on/off key, let go of ONLY the mode key.
  6. Index over to the hand graphic on the LCD screen to edit.
    Use the up or down arrow key to choose ‘SEL’ or ‘CLR’.

KOZY HEAT NDK-48-DV Direct Vent Gas Fireplace - Figure
11.16

11.9.11 Remote Control Low Battery Detection
Remote control battery lifespan depends on various factors including battery quality, number of ignitions, chang- es to room thermostat set point, etc.

  • When the remote control batteries are low, a battery icon will appear on the LCD display before all battery power is lost.
  • When the batteries are replaced, this icon will disappear.

Pressure Testing and Burner Adjustments

12.1 Pressure Testing
NOTE: The appliance and its appliance main gas valve must be disconnected from the gas supply piping system during any pressure testing of the system at test pressures in excess of 1/2 psi (3.5 kPa).
IMPORTANT: Pressure check taps for manifold (outgoing) and inlet (incoming) pressure have been incorporated into the valve. The pressure tap marked OUT measures outgoing pressure. The pressure tap marked IN measures incoming pressure.
12.1.1 Inlet Pressure Test
NOTE: Make sure to apply these incoming pressure test with all other gas appliances on, or at full capacity, in the house for proper pressure reading.
IMPORTANT: If the inlet pressure reading is too high or too low, contact the gas company. Only a qualified gas service technician should adjust incoming gas pressure.

  1. Loosen the inlet (IN) pressure tap by turning screw counter-clockwise. See (A) in FIGURE 12.1.

  2. Attach manometer using a 1/4” (6mm) I.D. hose.

  3. Light pilot and burner. Check pressure to ensure it is between the minimum and maximum recommended pressure settings (TABLE 12.1).

  4. Turn off burner and pilot.

  5. Disconnect hose and tighten the inlet (IN) pressure tap by turning screw clockwise. Screw should be snug.
    Do not over tighten.

  6. Relight pilot and burner. Then reattach manometer to the inlet pressure tap (A) to verify the tap is com- pletely sealed. Manometer should read no pressure.

Table 12.1 Inlet Pressures


Fuel| Natural Gas| Propane
Gas Supply| Min – Max| Min – Max
Inlet Pressure Tap (A)| 5” – 10.0” WC  (1.25 – 2.49 kPa)7” WC (1.74 kPa) recommended| 11”-13” WC  (2.74 – 3.24 kPa)

Table 12.2 Manifold Pressures


Fuel| Natural Gas| Propane
Gas Supply| Low – High| Low – High
Inlet Pressure Tap (A)| 1.6” – 3.5” WC (0.40 – 0.87 kPa)| 6.4” – 10” WC (1.59 – 2.49 kPa)

12.1.2 Manifold Pressure Test

  1. Light pilot.
  2. Loosen manifold (OUT) pressure tap by turning screw counter-clockwise. See (B) in FIGURE 12.1.
  3. Attach manometer to pressure tap using a 1/4” (6mm) I.D. hose.
  4. Light burner. Check manometer reading. Refer to TABLE 12.2.
  5. Turn burner and pilot off.
  6. Disconnect manometer hose and tighten the manifold (OUT) pressure tap by turning screw clockwise. Screw should be snug. Do not over tighten.
  7. Attach the manometer to the manifold pressure tap (B) to verify it is completely sealed. The manometer should read no pressure when pilot and burner are on.

KOZY HEAT NDK-48-DV Direct Vent Gas Fireplace - Figure
12.1

12.2 Flame Appearance Adjustment
WARNING: To avoid property damage or personal injury, allow the fireplace ample time to cool before making any adjustments.
Burner flame appearance and characteristics are affected by altitude, fuel quality, venting configuration, and other factors. After installation, this appliance may need additional adjustments to achieve optimum flame appearance and visual aesthetics.
12.2.1 Burner Venturis
WARNING: VENTURI ADJUSTMENT MUST BE DONE BY A QUALIFIED SERVICE TECHNICIAN.
NOTE: Burner venturi air shutter settings have been factory set. Refer to TABLE 12.3.
When this appliance is first lit, the burner flames will appear blue.
During the first 15 minutes of operation, flame appearance will grad- ually turn to the desired yellow appearance. If the flames remain blue or become dark orange with evidence of sooting (black tips), adjustment of the air shutter opening may be necessary. Regardless of venturi orientation, closing the air shutter will achieve a desired yellow flame, but may produce soot on the glass. Opening the air shutter will cause a short, blue flame that may lift off the burner.
12.2.2 Venturi Opening Adjustments
IMPORTANT: Slight adjustments to the venturi opening will create dramatic results. Adjust at slight increments until desired look is achieved.

  1. Remove the safety barrier, glass frame assembly, glass media, and lava rock (if installed). Remove media tray.
  2. Loosen the screw on burner venturis and adjust as necessary. Retighten screws.
  3. Reinstall all components previously removed.

Table 12.3 Factory Set Venturi Openings


Fuel| Natural Gas| Propane
Left Burner| 1/16” (1.5mm)| 1/4” (6mm)
Right Burner| 1/16” (1.5mm)| 1/4” (6mm)

Rear Burner| 5/16” (8mm)| 5/16” (8mm)
Note: There are two venting scenarios where the left and right burner ven- turi openings must be adjusted to 3/8” (10mm). The first scenario is mini- mum horizontal 5×8 coaxial venting. The second scenario is when the fire- place is reduced down to 4”x6-5/8” coaxial pipe. See Section 8.5 for more venting information.

Table 12.4 Flame Appearance Venturi Adjustment


Flame Characteristics| Cause| Solution
Dark, orange flame with black tips| Venturi closed too far| Open venturi slightly
Short, blue flames| Venturi open too far| Close setting slightly
Lifting (ghosting) flames| Gas pressure too high and/ or venturi closed too far| Check manometer settings and/ or open venturi setting slightly

KOZY HEAT NDK-48-DV Direct Vent Gas Fireplace - Figure
12.3

12.2.3 Vent Restriction (after installation)
WARNING: To avoid property damage or personal injury, allow the fireplace ample time to cool before making any adjustments.
WARNING: Improper vent installation may cause the burner flames to lift or “ghost.” Perform a visual check on flame appearance after restriction adjustment to ensure proper performance.
Vertical terminations may display an active, compact flame. If this appearance is not desirable, a restrictor plate may need to be installed or modified after vent termination installation. Access to the vent exit for restriction can be reached through the fireplace
baffle. See Figure 12.4
Refer to TABLE 12.4 and FIGURE 12.3 for flame appearance adjustments. Allow the fireplace to burn for 15 minutes before making any adjustments.

Restrictor Plate Installation

  1. Remove the safety barrier and glass frame assembly.
  2. Remove refractory (if installed) and log set.
  3. Remove (4) screws securing the fireplace baffle.
  4. Bend the tabs on the restrictor (included in fireplace components packet) to approximately 80° angles. This will create tension when the restrictor is inserted into the exhaust pipe.
  5. Insert restrictor into the 5” (127mm) exhaust pipe with the tabs pointing towards you.
  6. Reinstall the fireplace baffle with (4) screws previously removed.
  7. Reinstall all components previously removed.

Table 12.5 Restrictor Plate Adjustment Guidelines


Flame Appearance| Draft Problem| Solution
Short, flickering| Excessive draft and/or not enough restriction| Add restrictor plate
Lifting or ghosting| Insufficient draft| Remove inner ring(s) on re- strictor plate or remove re- strictor plate
*If flames continue to lift or ghost after opening the restrictor plate and verify- ing correct vent installation, shut off the gas supply and call a qualified service technician.

Restrictor Plate Modification

  1. Remove the safety barrier and glass frame assembly.
  2. Remove refractory (if installed) and log set.
  3. Remove (4) screws securing the fireplace baffle.
  4. Remove the restrictor from the 5” (127mm) exhaust pipe by pulling the restrictor down and out.
  5. Make necessary modifications to achieve desired flame appearance.
  6. Insert restrictor into the 5” (127mm) exhaust pipe with the tabs pointing towards you.
  7. Reinstall the fireplace baffle with (4) screws previous- ly removed.
  8. Reinstall all components previously removed.

KOZY HEAT NDK-48-DV Direct Vent Gas Fireplace - Figure
12.4

Troubleshooting

ATTENTION: Troubleshooting must be performed by a qualified technician. Before proceeding with the steps in the following troubleshooting guide,

  • Verify proper 120VAC power supply to the control module.
  • Verify the control module back-up battery pack and the remote control batteries are fresh and installed with correct polarity.
  • Verify all connections between the wire harnesses and the system components are proper and positive.
  • Verify inlet pressure meets the recommended inlet pressure. If necessary, adjust line pressure regulator.
  • Verify the communication link is established between the remote control and the IFC module.
  • CAUTION: Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation. Verify proper operation after servicing.
Issue Cause Solution
Pilot will not light Electrical power interrupted or disconnected Restore

electrical power to appliance or use battery back-up
Wiring disconnection| Ensure batteries are fully charged if using battery back- up as power source.
Use wiring schematic in this manual to determine that all wiring connections are secure and correct.
Gas supply turned off| Check remote shut-off valves from the appliance. Usu- ally there is a valve near the main gas line. There may be more than (1) valve between the appliance and main gas line.
Pilot will not stay lit| No propane in tank| Check propane tank. Refill if necessary.
Low gas pressure| Consult a plumber or gas supplier Can be caused by situation such as a bent line, too nar- row diameter or pipe, or a low line pressure
Pilot adjustment screw not sealed| Seal pilot adjustment screw. Do not over- tighten.
Pilot flame not making contact with the flame rectification sen- sor on the pilot assembly| Verify the pilot envelopes the top of the flame sensor and extends far enough onto the burner for ignition
Pilot flame always on, or will not extinguish| Control system set to CPI mode.| Set control system to IPI mode.
Issue| Cause| Solution
---|---|---
Burner flame will not light| ON/OFF rocker switch in OFF position| Switch rocker switch to ON position.
Gas supply turned off| Check for multiple shut-offs in the supply line. Verify gas supply is turned on.
Low gas supply| Consult with plumber or gas supplier.
Check propane tank. Refill if necessary.
Wiring disconnection or improper wiring| Check for faulty or incorrect wiring. Refer to FIG- URE 10.1, Electrical Diagram.
Plugged burner orifice| Remove blockage.
Pilot flame| Verify the pilot flame is properly directed to ignite burner. See pilot flame troubleshooting in this section.
Remote control not working| Replace Batteries.
No call for heat| Verify remote control is powered ON and thermo- stat operation is turned OFF.
Pilot and burner extinguish while in operation| No propane in tank| Check propane tank, Refill if necessary.
Incorrect glass assembly installation| Refer to section 9.1, GLASS ASSEMBLY.
Incorrect vent cap installation| Adjust if necessary.
Vent cap blockage| Remove debris if necessary.
Improper pitch on horizontal venting| 1/4” (6mm) rise for ever 12” (305mm) of travel is required on horizontal venting.
Exhaust vent pipe leaking exhaust gases back into firebox| Check for leaks and repair if necessary.
Excessive draft| A restrictor may need to be installed or modified. Refer to section 12.2.3 Vent Restriction.
Soot appears on glass| Improper log placement| Refer to section 9.5, LOG SET INSTALLATION.
Improper venturi settings| Venturi air shutters may need to be opened slight- ly to allow more air into the gas mix. Refer to sec- tion 12.2.1, BURNER VENTURIS.
Incorrect vent cap installation| Adjust if necessary.
Vent cap blockage| Remove debris if necessary.
Issue| Cause| Solution
---|---|---
Flame burns blue and lifts off burner| Improper venturi setting| The venturi air shutter may need to be close slightly to allow less air into the gas mix. Refer to section 12.2.1, BURNER VEN- TURIS.
Incorrect vent cap installation| Adjust if necessary.
Blockage or leakage of the vent system| Check the vent pipes for leaks and the vent cap for debris. Repair the vent pipes or remove debris from vent cap, if necessary.
No reaction to command| Battery backup batteries or remote control batteries low| Replace the batteries.
No communication between remote con- trol and control module| Reprogram remote control to IFC module
A maximum number of failed ignitions or flame restorations has been reached.| Reset IFC module

Maintenance

ATTENTION: Installation and repair should only done by a qualified service person. The appliance should be inspected before use and at least annually by a professional service person. More frequent cleaning might be required due to excessive lint from carpeting, bedding material, et cetera. It is imperative that control compartments, burners, and circulating air passageways of the appliance be kept clean. Use a vacuum to clean all components.
WARNING: The appliance area must be kept clear and free from combustible materials, gasoline and other flammable vapors and liquids.

14.1 Firebox
Performed by: Qualified Service Person
Frequency: Annually
Action:

  • Vacuum and clean any debris in the firebox that is not supposed to be there.
  • Inspect and operate the bottom latch assembly. Verify the assembly is free from obstruction to operate. The handles must have spring tension but be able to moveforward freely

14.2 Fan
CAUTION: Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation. Verify proper operation after servicing.
Performed by: Qualified Service Person
Frequency: Annually
Action:

  • Disconnect the fan from electrical current and vacuum.
  • The bearings are sealed and require no oiling.

14.2.1 Fan Kit Removal

  1. Disconnect electrical power.
  2. Remove the safety barrier screen and glass valance.
  3. Remove optional panel set and log set.
  4. Remove the control board – refer to Section 8.5.2. As you remove the control board disconnect the fan kit wiring from the control module
  5. After the control board is removed you can reach through the control board opening to remove (4) 7/16 flange nuts that secure the fan kit to the bottom of the fireplace.
  6. Remove the fan kit and service.
  7. Reinstall in reverse order. Reinstall all previously re- moved components

14.3 Vent System
NOTE: If the vent-air intake system is disassembled for any reason, reinstall per instructions provided with installation. If installing Kozy Power Vent (#KPV), please reference the manual included with the kit. For natural draft vent installation, refer to section
8.0, VENTING.
Performed by: Qualified Service Person
Frequency: Annually
Action:

  • Examination of the vent system is required.
  • Inspect the condition of vent and vent terminal for sooting or obstruction and correct if present.
  • The flow of combustion and ventilation air must not be obstructed.

14.4 Glass Assembly
CAUTION: Do not operate appliance with the glass assembly removed, cracked, or broken. Use protective gloves to handle any broken or damaged glass assembly components.
WARNING: Do not use substitute materials.
WARNING: Avoid striking or slamming glass assembly. Avoid abrasive cleaner. DO NOT clean glass while it is hot.
IMPORTANT: Any safety screen, guard, or barrier removed for servicing the appliance must be replaced prior to operating the appliance.
Performed by: Homeowner
Frequency: Annually
Action:

  • Prepare a work area large enough to accommodate the glass assembly on a flat, stable surface.
  • Remove safety screen and glass frame assembly.
  • Clean glass window with a suitable fireplace glass cleaner using a soft cloth. Abrasive cleaners must not be used. Be careful not to scratch the glass when cleaning.
  • Reinstall glass assembly and safety screen. Do not operate fireplace without safety screen.

Performed by: Qualified Service Person
Frequency: Annually
Action:

  • Clean glass window with a suitable fireplace glass cleaner using a soft cloth. Abrasive cleaners must not be used. Be careful not to scratch the glass when cleaning.
  • Inspect the glass for cracks, scratches, and nicks.
  • Verify the glass assembly is properly intact and not dam- aged.
  • Replace the glass and the assembly #701-067T as neces- sary.
  • Only Hussong Mfg. Co., Inc. will supply the replacement of glass assembly as a complete unit.

14.5 Burner and Pilot System
The burner assembly may be removed for easier access to the control compartment. See Section 9.6 Control Board Removal and Installation for instructions.
Verify gas supply is turned on and filled. Consult with plumber or gas supplier as necessary.
Performed by: Qualified Service Person
Frequency: Annually
Action:

  • Vacuum all components of the burner system.
  • Check all accessible gas-carrying tubes, connections, pipes and other components for leaks.
  • Inspect the operation of the flame safety system Pilot or Flame rectification device. Visually check pilot light when in operation.
  • Inspect and ensure the lighting of the main burner occurs within (4) seconds of the main gas valve opening. Check for faulty or incorrect wiring and correct or replace as necessary. Inspect primary air openings (burner ports) for blockage, especially near the pilot.
  • Visually check burner flame pattern when in operation. Flames should be steady, not lifting or floating.
  • Test and measure the flame failure response time of the flame safety system. It must de-energize the safety shutoff in no more than (30) seconds.

KOZY HEAT NDK-48-DV Direct Vent Gas Fireplace - Figure
14.1KOZY HEAT NDK-48-DV Direct Vent
Gas Fireplace - Figure 14.2

Replacement Parts List

P.O. BOX 557 204 INDUSTRIAL PARK DRIVE LAKEFIELD, MINNESOTA USA 56150-0577

Replacement parts are available through your local dealer. Contact your local dealer for availability and pricing. The following warning is for replacement parts for this appliance.
WARNING: This product can expose you to chemicals including Lead, which is [are] known to the State of California to cause cancer, birth defects or other reproductive harm. For more information, visit www.P65Warnings.ca.gov.

Control Board and Parts


S.I.T. Complete Board Assembly –

Natural Gas

| NK48-130| | Natural Gas – Valve Stepper Motor| 700-503
S.I.T. Complete Board Assembly –

Propane

| NK48-131| | Propane – Valve Stepper Motor| 700-503-1
S.I.T. IPI Gas Valve – Natural Gas| 700-660| | Burner Orifice – #43 (Left and Right) –  Natural Gas| 700-243
S.I.T. IPI Gas Valve – Propane| 700-660-1| | Burner Orifice – #53 (Rear) – Natural Gas| 700-253
Main Power Wire Harness| 700-350| | Burner Orifice – #1.40mm (Left and Right) –  ropane| 700-140M
Proflame 2 IFC Module| 700-652| | Burner Orifice – #69 (Rear) – Propane| 700-2692
IFC Wire Harness Assembly| 700-653| | Left Burner Assembly| NK48-350
Fan / Light Kit Wire Harness| 700-655| | Right Burner Assembly| NK48-351
ON/OFF Wire Harness| 700-656| | Rear Burner| NK48-035
Ember Bed AUX Harness| 800-AUX| | Left Burner Rockwool Screen| NK48-350S
S.I.T. IPI Pilot Assembly – Natural Gas| 700-551| | Right Burner Rockwool Screen| NK48-351S
S.I.T. IPI Pilot Assembly – Propane| 700-551-1| | 18” Black Flex Tube| 700-213B
Pilot Orifice – Natural Gas #62| 700-166| | 7” Flare x Brazed Fitting| 700-223F
Pilot Orifice – Propane #35| 700-168| | S.I.T. Transmitter (Remote Control)| 700-408
S.I.T. Conversion Kit – Natural Gas| NCK-NK48-S30| | |
S.I.T. Conversion Kit – Propane| LCK-NK48-S30| | |

Glass and Glass Parts


Glass with Gasket – 43-1/4” x 34-5/8”| 701-067T
1 1/8” Glass Gasket with Adhesive| 900-006
Replacement Valance| NK48-005

Safety Barriers


Full Rectangle Screen Front| NK48-FRSF
NK48-FRSF Replacement Screen| NK48-ES2
Prairie Screen Front| NK48-PSF
NK48-PSF Replacement Screen| NK48-ES2
Rectangle Screen Vented Front| NK48-RSVF
NK48-RSVF Replacement Screen| NK48-ES3
Prairie Screen Vented Front| NK48-PSVF
NK48-PSVF Replacement Screen| NK48-ES3
Arched Mission Screen Front| NK48A-MSF
NK48A-MSF Replacement Screen| NK48-ES
Rectangle Mission Screen Front| NK48R-MSF
NK48R-MSF Replacement Screen| NK48-ES

Additional Components


5” (127mm) Restrictor Plate| 900-086
Manual Gas Shut-off Valve| 700-203
Bottom Frame| NK48-201B
Finishing Trim Kit| NK48-FTK

Light Kits


20W Halogen Bulb| 600-676
Light Kit – Ember Bed| NK48-LKT
Light Kit – Top| NK48-TLK
1.5lb. (0.68kg) Ember Bed Crushed Glass| 600-697

Log Set


13 Piece Log Set| NK48-500
Log #1| NK48-1
Log #2| NK48-2
Log #3| NK48-3
Log #4| NK48-4
Log #5| NK48-5
Log #6| NK48-6
Log #7| NK48-7
Log #8| NK48-8
Log #9| NK48-9
Log #10| NK48-10
Log #11| NK48-11
Log #12| NK48-12
Log #13| NK48-13

Fan Kit


Fan Kit| IPI-028

Limited Lifetime Warranty

Warranty Coverage
Hussong Manufacturing Company, Inc. (Hussong Mfg.) warrants this Kozy Heat gas appliance from the date of purchase to the original purchaser, that it is free of defects in materials and workmanship at the time of manufacture.
Registering your fireplace warranty does not require any documents to be sent in to Hussong Mfg. Please retain your proof of purchase reflecting the date of purchase along with the serial number and model of your fireplace for any future warranty claims.
If a defect is noted within the warranty period, the customer should contact their authorized dealer for service within 30 days.

**30 Days: Parts & Labor***

  • Paint
  • Light bulbs
  • Gasket material
  • Glass media and media dam

**Year 1: Parts & Labor**
All parts and material except the items listed in the 30 day warranty and any exclusions or limitations that may apply
Hussong Mfg. will issue labor reimbursement to an authorized dealer only. Hussong Mfg. will not be liable for charges occurred as a result of any service performed by a nonauthorized service provider, without pre-authorization.

Years 2 through Lifetime: Parts Only

  • Firebox
  • Heat Exchanger
  • Logs
  • Burner tube or pan
  • Outer shell
  • Heat shield(s)
  • Front Viewing Glass (thermal shock only)
  • Refractory Firebox liner (excluding enamel and glass pan- els)

EXCLUSIONS AND LIMITATIONS

  1. This appliance must be installed by a licensed, authorized service technician or contractor. It must be installed, operated and maintained at all times in accordance with the instructions in the owner’s manual or the warranty is void.
  2. This warranty is nontransferable and is made to the original purchaser only.
  3. This warranty excludes standard wear and tear of the appliance which is considered normal usage over time.
  4. Discoloration and some minor expansion, contraction or movement of certain parts, resulting in noise, is normal and not a defect.
  5. Warranty is automatically voided if the appliance’s serial number and/or testing label is removed or if the appliance is al- tered or tampered with in any way.
  6. Warranty is void if the appliance is subject to submersion in water or prolonged periods of dampness or condensation. Any damage to any part of the appliance due to water or weather damage which is the result of, but not limited to, improper chimney/venting installation will also render this warranty void.
  7. This warranty does not cover installation and operational related problems such as environmental conditions, nearby trees, buildings, hilltops, mountains, inadequate venting or ventilation, excessive offsets, negative air pressures caused by any mechanical systems.
  8. Chimney components and other Non-Hussong Mfg. accessories used in conjunction with the installation of this appliance are not covered under this warranty.
  9. Damage to plated surfaces or accessories, if applicable, caused by scratches, fingerprints, melted items or other external sources left on the surfaces from the use of cleaners is not covered under this warranty.
  10. It is expressly agreed and understood that this warranty is Hussong Mfg.’s sole obligation and purchaser’s exclusive reme- dy for defective fireplace equipment. Hussong Mfg. is free of liability for any damages caused by this appliance, as well as inconvenience expenses and materials. Incidental or consequential damages are not covered by this warranty. In some states, the exclusion of incidental or consequential damage may not apply. Hussong Mfg. shall not be held to implied warranties and this warranty shall replace all previous warranties.
  11. This limited lifetime warranty is the only warranty supplied by Hussong Mfg. Any warranties extended to the purchaser by the dealer/distributor, whether expressed or implied, are hereby disclaimed and the purchaser’s recourse is expressly limited to the warranties set forth herein.
  12. Any part repaired or replaced during the limited warranty period will be warranted under the terms of the limited warranty for a period not to exceed the remaining term of the original limited warranty.
  13. Any replacement part repaired after the warranty period will include a 90 day parts coverage
  14. Hussong Mfg. may require the defective part to be returned using a pre-authorized RGA number or a photo of the defec- tive component. Failure to provide either can result in a denied claim.
  15. This warranty does not cover the appliances ability to heat a desired space, as there are many factors that can impact the heating performance in each home. Consideration should be implied to the appliance’s location, room size, home design, environmental conditions, insulation, and tightness of the home.
  16. Hussong Mfg. reserves the right to make changes at any time, without notice, in design, material, specifications, and prices. Hussong Mfg. reserves the right to discontinue models and products.

KOZY HEAT logoHussong Mfg. Co, Inc.
NDK-48-DV – PFS Report No. 23-196
Rev. 1 – November 2023
Starting Serial Number: 24 N48DV00001 04

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Kozy Heat User Manuals

Related Manuals