KOZY HEAT Slayton 36 Direct Vent Fireplace Instructions
- June 10, 2024
- Kozy Heat
Table of Contents
Slayton 36 Direct Vent Fireplace
Please leave these reference guides at the installation location until the
installation is finished. See owners manual for full installation and
finishing instructions before making final decisions as information is subject
to change.
Specifications (all measurements are in inches)
__**Model| __**BTU| Height| Front Width| Back
Width| Depth| Glass Viewing Area
---|---|---|---|---|---|---
Actual| Framing| Actual| Framing| Actual| Framing| Actual| Framing
SLA‐36| 33,000| 28‐13/16| 36‐5/8| 43‐5/8| 48‐3/4| 43‐5/8| 48‐3/4| 15‐13/16|
19| 14 x 36
- GAS LINE OPENING: LEFT/RIGHT SIDES
- ELECTRICAL ACCESS: RIGHT SIDE
Framing Opening
Dimension | SLA‐36 |
---|---|
A | 62‐1/4 |
B | 36‐5/8 |
C | 48‐3/4 |
D | 19 |
E | F | G | H | I | J | K | L | M |
---|---|---|---|---|---|---|---|---|
19 | 48‐3/4 | 19 | 48‐3/4 | 87‐3/4 | 48‐3/4 | 24‐1/4 | 43‐7/8 | 62 |
Finishing Clearances
Dimension | SLA‐36 |
---|---|
N | 50‐1/4 |
O | 38‐1/8 |
Mantel Clearances
Dimension
P| Q| R| S| T| U
40| 14‐1/4| 19‐1/4| 25‐1/4| 33‐3/8| 62‐1/4
Finish Trim Kit
Important!
If you are finishing around the fireplace with tile or stone make sure that
you install the Finishing Trim Kit at the framing stage.
The trim kit allows for your finishing board and your tile/stone to finish up
against, creating a shadowbox for the face to sit inside.
Horizontal Termination Framing
A horizontal Wall Thimble allowing a 1” clearance is required
Dimension | SLA‐36 |
---|---|
V | 19 |
W | 35‐5/8 |
X | 47‐5/8 |
Y | 43 |
Horizontal 5” X 8” Venting Minimum Requirements
Note specific gas type minimums
Requirement | SLA‐36 |
---|---|
(NG) Vertical Min | 90o Elbow |
(NG) Horizontal Min | 9 |
(NG) Horizontal Max | 4 ft. |
Requirement | SLA‐36 |
---|---|
(LP) Vertical Min | 90o Elbow |
(LP) Horizontal Min | 9 |
(LP) Horizontal Max | 9 |
Requirement | SLA‐36 |
---|---|
(LP) Vertical Min | 6 AND 9 |
(LP) Horizontal Min | 9 |
(LP) Horizontal Max | 4 ft. |
Consult venting chart in the manual for all options above minimum requirements
H = Horizontal
V = Vertical
4” x 6‐5/8”
Decreaser Minimum Requirements
Requirement | SLA‐36 |
---|---|
(NG) Vertical Min | 12 |
(NG) Horizontal Min | 9 |
(NG) Horizontal Max | 3 ft. |
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>