KOZY HEAT Slayton 36 Direct Vent Fireplace Instructions

June 10, 2024
Kozy Heat

KOZY HEAT -logo Slayton 36 Direct Vent Fireplace

Please leave these reference guides at the installation location until the installation is finished. See owners manual for full installation and finishing instructions before making final decisions as information is subject to change.
Specifications (all measurements are in inches)

__**Model| __**BTU| Height| Front Width| Back Width| Depth| Glass Viewing Area
---|---|---|---|---|---|---
Actual| Framing| Actual| Framing| Actual| Framing| Actual| Framing
SLA‐36| 33,000| 28‐13/16| 36‐5/8| 43‐5/8| 48‐3/4| 43‐5/8| 48‐3/4| 15‐13/16| 19| 14 x 36

  • GAS LINE OPENING: LEFT/RIGHT SIDES
  • ELECTRICAL ACCESS: RIGHT SIDE

Framing Opening

Dimension SLA‐36
A 62‐1/4
B 36‐5/8
C 48‐3/4
D 19

KOZY HEAT Slayton 36 Direct Vent Fireplace -

E F G H I J K L M
19 48‐3/4 19 48‐3/4 87‐3/4 48‐3/4 24‐1/4 43‐7/8 62

Finishing Clearances

Dimension SLA‐36
N 50‐1/4
O 38‐1/8

Mantel Clearances

KOZY HEAT Slayton 36 Direct Vent Fireplace - Clearances
1

Dimension

P| Q| R| S| T| U
40| 14‐1/4| 19‐1/4| 25‐1/4| 33‐3/8| 62‐1/4

Finish Trim Kit

Important!
If you are finishing around the fireplace with tile or stone make sure that you install the Finishing Trim Kit at the framing stage.
The trim kit allows for your finishing board and your tile/stone to finish up against, creating a shadowbox for the face to sit inside.

Horizontal Termination Framing

KOZY HEAT Slayton 36 Direct Vent Fireplace - Framing

A horizontal Wall Thimble allowing a 1” clearance is required

Dimension SLA‐36
V 19
W 35‐5/8
X 47‐5/8
Y 43

Horizontal 5” X 8” Venting Minimum Requirements

Note specific gas type minimums

Requirement SLA‐36
(NG) Vertical Min 90o Elbow
(NG) Horizontal Min 9
(NG) Horizontal Max 4 ft.
Requirement SLA‐36
(LP) Vertical Min 90o Elbow
(LP) Horizontal Min 9
(LP) Horizontal Max 9
Requirement SLA‐36
(LP) Vertical Min 6 AND 9
(LP) Horizontal Min 9
(LP) Horizontal Max 4 ft.

Consult venting chart in the manual for all options above minimum requirements

H = Horizontal
V = Vertical
4” x 6‐5/8”
Decreaser Minimum Requirements

KOZY HEAT Slayton 36 Direct Vent Fireplace - Venting3

Requirement SLA‐36
(NG) Vertical Min 12
(NG) Horizontal Min 9
(NG) Horizontal Max 3 ft.