KOZY HEAT Callaway 50 Direct Vent Fireplace Instructions

June 10, 2024
Kozy Heat

KOZY HEAT Callaway 50 Direct Vent Fireplace

KOZY HEAT Callaway 50 Direct Vent Fireplace 

Please leave these reference guides at the installation location until the installation is finished. See owners manual for full installation and finishing instructions before making final decisions as information is subject to change.

Specifications (all measurements are in inches)

• GAS LINE OPENING: LEFT SIDE • ELECTRICAL ACCESS: RIGHT SIDE+

__

Model

| __

BTU

| Height| Front Width| Back Width| Depth| Glass Viewing Area
---|---|---|---|---|---|---
Actual| Framing| Actual| Framing| Actual| Framing| Actual| Framing
__

CLW‐50

| 35,500 (NG)

35,000 (LP).

| __

39

| __

44‐1/2

| __

59‐1/2

| __

64‐1/2

| __

59‐1/2

| __

64‐1/2

| __

18‐15/16

| __

22

| __

49‐7/8 x 13‐3/8

Framing Opening

Dimension CLW‐50
A 44‐1/2
B 48
C 64‐1/2
D 22
E F G H I J K L M
22 64‐1/2 22 64‐1/2 106‐13/16 64‐1/2 25‐7/8 53‐7/16 75‐9/16

Framing Opening

Finishing Clearances

Dimension CLW‐50
N 66
O 48‐3/4

Finishing Clearances

Mantel Clearances

Dimension


P| Q| R| S| T| U
48| 18| 21‐1/2| 27‐1/2| 22| 48

Mantel Clearances

Horizontal Termination Framing

Dimension CLW‐50
V 22
W 34‐3/8
X 44‐3/4
Y 42

Horizontal Termination Framing

A Kozy Heat #800‐WPT series wall pass thru is required with use of the flex‐vent kit.

Horizontal Termination Framing

Horizontal 5” X 8” Venting Minimum Requirements

Requirement CLW‐50
(NG/LP) Vertical Min 45o Elbow
(NG/LP) Horizontal Min 6
(NG/LP) Horizontal Max 24

Horizontal 5” X 8” Venting Minimum Requirements

Consult venting chart in the manual for all options above minimum requirements

H = Horizontal
V = Vertical

Requirement* CLW‐50
(NG/LP) Vertical Min 45o Elbow + 90o Elbow
(NG/LP) Horizontal Min 6
(NG/LP) Horizontal Max 48

Horizontal 5” X 8” Venting Minimum Requirements
*Requirement when initially using 45o Elbow Vertically

4” x 6‐5/8” Decreaser Minimum Requirements

Requirement CLW‐50
(NG/LP) Vertical Min 45o Elbow + 24 + Decreaser
(NG/LP) Horizontal Min 90o Elbow
(NG/LP) Horizontal Max 48

4” x 6‐5/8” Decreaser Minimum Requirements

Requirement CLW‐50
(NG/LP) Horizontal Min 45o Elbow + Decreaser
(NG/LP) Vertical Min 10
(NG/LP) Vertical Max 50 ft.

CO‐LINEAR 3” X 3” FLEX PIPE VERTICAL VENTING

4” x 6‐5/8” Decreaser Minimum Requirements

Heat Shield Requirements

*The horizontal vent heat shield must be installed when using a horizontal 45° elbow of the back of the appliance.