KOZY HEAT Carlton Series Direct Vent Fireplaces Instructions

June 10, 2024
Kozy Heat

**KOZY HEAT Carlton Series Direct Vent Fireplaces

**

Introduction

Please leave these reference guides at the installation location until the installation is finished. See owners manual for full installation and finishing instructions before making final decisions as information is subject to change.

Specifications (all measurements are in inches)

Model

|

BTU

| Height| Front Width| Back Width| Depth| Glass Viewing Area
---|---|---|---|---|---|---
Actual| Framing| Actual| Framing| Actual| Framing| Actual| Framing

CAR‐39

| 40,000 (NG)

41,000 (LP)

|

34‐1/2

|

44‐1/2

|

38‐3/4

|

39‐3/4

|

19‐15/16

|

39‐3/4

|

22

|

22‐1/2

|

28‐1/8 x 32‐7/16

CAR‐46| 45,000| 36| 46| 45‐3/4| 46‐1/4| 22‐38| 45‐3/4| 21‐1/2| 22| 27‐1/2 x 39‐7/16

Framing Opening

Dimension CAR‐39 CAR‐46
A 44‐1/2 46
B 39‐3/4 46‐1/2
C 22 21‐1/2

Framing Opening

Dimension CAR‐39 CAR‐46
D 22 21‐1/2
E 39‐1/4 46‐1/4
F 62‐5/8 64‐3/4
G 39‐3/4 46‐1/4
H 12‐9/16 13‐5/16
I 44‐5/16 45‐3/4
J 31‐5/16 32‐3/8

Finishing Clearances

Dimension CAR‐39 CAR‐46
K 39-3/4 46‐1/2
L 10 10

Mantel Clearances

Mantel Clearances

Dimension CAR‐39 CAR‐46 Dimension CAR‐39 CAR‐46
M 10 10 O 16 16
N 14 14 P 18 18

Finish Trim Kit

Important!
If you are finishing around the fireplace with tile or stone make sure that you install the Finishing Trim Kit at the framing stage.
The trim kit allows for your finishing board and your tile/stone to finish up against, creating a shadowbox for the face to sit inside.
Do not use with RSF fronts, all other fronts apply.

Horizontal Termination Framing

Dimension CAR‐39 (NG) CAR‐46 (NG)
R 22 21
S 46‐1/4 47‐3/4

Dimension| CAR‐39

(LP)

| CAR‐46

(LP)

---|---|---
T| 22| 21
U| 52‐1/4| 53‐3/4

Dimension| CAR‐39

(NG/LP)

| CAR‐46

(NG/LP)

---|---|---
V| 22| 21‐1/2
W| 51‐1/8| 52‐5/8

Horizontal Venting Minimum Requirements

Note specific model number and gas type minimums

Requirement CAR‐39 CAR‐46
(NG) Vertical Min 9 + 90o Elbow 9 + 90o Elbow
(NG) Horizontal Min 6 6
(NG) Horizontal Max 10 ft. 10 ft.

Consult venting chart in manual for all options above minimum requirements

Requirement CAR‐39 CAR‐46
(LP) Vertical Min 12 + 90o Elbow 12 + 90o Elbow
(LP) Horizontal Min 6 6
(LP) Horizontal Max 4 ft. 4 ft.

Horizontal Venting Minimum Requirements

CORNER VENTING|
---|---
Requirement| CAR‐46 (NG ONLY)
Vertical Min| 6 + 90o Elbow
Horizontal Min| 6
Horizontal Max| CAP

Horizontal Venting Minimum Requirements

CORNER VENTING|
---|---
Requirement| CAR‐39| CAR‐46 (LP ONLY)
(NG/LP) Vertical Min| 12 + 90o

Elbow

| 12 + 90o Elbow
(NG) Vertical Min| 12 + 90o

Elbow

| 12 + 90o Elbow
(LP) Horizontal Min| 6| 6
(LP) Horizontal Max| CAP| CAP

Heat Shield Requirements

The vertical vent heat shield must be installed for EVERY type of venting application. The horizontal vent heat shield must be installed when incorporating minimum horizontal venting and is positioned according to the gas type.

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals