KOZY HEAT Chaska 34 Direct Vent Insert Instructions
- June 10, 2024
- Kozy Heat
Table of Contents
**KOZY HEAT Chaska 34 Direct Vent Insert
**
Introduction
Please leave these reference guides at the installation location until the installation is finished. See owners manual for full installation and finishing instructions before making final decisions as information is subject to change.
Specifications (all measurements are in inches)
Model| BTU| Front Height| Back Height| Front Width|
Back Width| Depth| Glass Viewing Area
---|---|---|---|---|---|---|---
CSK‐34| 34,000| 23| 17‐3/8| 33‐3/8| 24‐3/8| 16| 29‐7/8 x 17‐1/2
Existing Fireplace Requirements
Dimension | CSK‐34 |
---|---|
A | 23‐1/2 |
B | 33‐1/2 |
C | 16‐3/8 |
D | 24‐1/2 |
Dimension | CSK‐34 |
---|---|
E | 11 |
F | 14 |
Mantel & Hearth Clearances
Dimension | CSK‐34 |
---|---|
G | 55 |
H | 12 |
I | 16 |
This appliance is zero‐clearance to a combustible floor if 7” of non‐combustible flooring is constructed in front of the unit. Otherwise, appliance must be raised 1”
Shroud Sizes
Shroud Part Number | |
---|---|
Dimension | #CK34‐2740 |
J | 27 |
K | 40 |
*Custom Sizes also available
Venting Requirements
Consult manual for approved venting manufacturers
Requirement | CSK‐34 |
---|---|
(NG/LP) Vertical Min | 10 ft. |
(NG/LP) Vertical Max | 50 ft. |
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>