KOZY HEAT Bellingham 44 Direct Vent Fireplace Instructions
- June 10, 2024
- Kozy Heat
Table of Contents
KOZY HEAT Bellingham 44 Direct Vent Fireplace Instructions
Please leave these reference guides at the installation location until the installation is finished. See owners manual for full installation and finishing instructions before making final decisions as information is subject to change.
Specifications (all measurements are in inches)
- GAS LINE OPENING: LEFT SIDE
- ELECTRICAL ACCESS: LEFT SIDE
Model| BTU| Height| Front Width| Back Width| Depth| Glass Viewing Area
---|---|---|---|---|---|---
Actual| Framing| Actual| Framing| Actual| Framing| Actual| Framing
BHM‐44| 49,500| 35‐1/4| 46‐1/4| 50‐5/8| 57‐5/8| 50‐5/8| 57‐5/8| 20| 22| 44‐7/16 x 24‐7/8
Framing Opening
Dimension | BHM‐44 |
---|---|
A | 88 |
B | 46‐1/4 |
C | 57‐5/8 |
D | 22 |
E | 60‐1/2 |
HORIZONTAL TERMINATION
VERTICAL TERMINATION
CORNER INSTALLATION
F | G | H | I | J | K | L | M | N |
---|---|---|---|---|---|---|---|---|
22 | 57‐5/8 | 22 | 57‐5/8 | 88‐1/2 | 57‐5/8 | 22‐1/2 | 44‐1/4 | 62‐1/2 |
Finishing Clearances
Dimension
O| P| Q| R| S
60‐5/8| 45‐3/16| 8‐1/16| 44‐1/2| 24‐15/16
COMBUSTIBLE MATERIAL ALLOWED
NON‐COMBUSTIBLE ZONE
NON‐COMBUSTIBLE ZONE ‐NO SCREWS ALLOWED ‐
Mantel Clearances
Each square represents 1” of mantel projection
Dimension
T| U| V| W| X
27‐1/2| 16| 19‐1/2| 25‐1/2| 25
Horizontal Termination Framing
Minimum Natural & LP Gas
Dimension | BHM‐44 |
---|---|
Y | 22 |
Z | 67‐3/4 |
Horizontal Venting Minimum Requirements
2 options shown here. Consult venting chart in manual for additional options & above minimum requirements
H = Horizonta
V = Vertical
Requirement | BHM‐44 |
---|---|
(NG/LP) Vertical Min | 24 + 90o Elbow |
(NG/LP) Horizontal Min | 6” |
(NG/LP) Horizontal Max | 24” |
Requirement | BHM‐44 |
---|---|
(NG/LP) Vertical Min | 36 + 90o Elbow |
(NG/LP) Horizontal Min | 6” |
(NG/LP) Horizontal Max | 8 ft. |
Vertical Venting Minimum Requirements
Requirement | BHM‐44 |
---|---|
(NG/LP) Vertical Min | 3 ft. |
(NG/LP) Vertical Max | 50 ft. |
Vertical Terminations with Reducer
Requirement | BHM‐44 |
---|---|
(NG/LP) Vertical Min | 4” x 6‐5/8” Reducer + 3 ft. |
(NG/LP) Vertical Max | 50 ft. |
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>