KOZY HEAT SP-34 Direct Vent Fireplace Instructions

June 10, 2024
Kozy Heat

KOZY HEAT -logo SP‐34 Direct Vent Fireplace

Please leave these reference guides at the installation location until the installation is finished. See owners manual for full installation and finishing instructions before making final decisions as information is subject to change.
Specifications (all measurements are in inches)

Model| BTU| Height| Front Width| Back Width| Depth| Glass Viewing Area
---|---|---|---|---|---|---
Actual| Framing| Actual| Framing| Actual| Framing| Actual| Framing
SP‐34| 20,500| 30‐7/8| 33‐1/2| 34| 34‐1/2| 27| 34‐1/2| 14| 14‐1/2| 27‐1/4 x 19‐3/4

  • GAS LINE OPENING: RIGHT SIDE
  • ELECTRICAL ACCESS: LEFT SIDE

Framing Opening

KOZY HEAT SP 34 Direct Vent Fireplace -

Dimension SP‐34
A 33‐1/2
B 34‐1/2
C 14
Dimension SP‐34
D 14
E 34‐1/2
F 14
G 34‐1/2
H 54‐7/16
I 34‐1/2
J 13‐1/8
K 27‐1/4
L 38‐1/2

Finishing Clearances

Dimension SP‐34
M 4‐1/2
N 12
O 42

Mantel Clearances

MANTEL PROJECTION: 1” UP FOR EVERY 1” DEEPER (After ini al 37”)

KOZY HEAT SP 34 Direct Vent Fireplace - Clearances1

Dimension

P| Q| R| S| T| U
37| 6| 1| 33‐1/2| 12| 42

Finish Trim Kit
Important!
If you are finishing around the fireplace with tile or stone make sure that you install the Optional
Finishing Trim Kit at the framing stage.
The trim kit allows for your finishing board and your le/stone to finish up against, creating a shadowbox.

Horizontal Termination Framing

Dimension SP‐34
V 14
W 35‐1/4
X 14
Y 42

KOZY HEAT SP 34 Direct Vent Fireplace - Framing1

A Kozy Heat #700‐WPT series wall pass thru is required with use of the flex‐vent kit.

Horizontal Venting Minimum Requirements

Requirement SP‐34
(NG/LP) Vertical Min 90o Elbow
(NG/LP) Horizontal Min 6
(NG/LP) Horizontal Max 4

Consult venting chart in manual for op ons above minimum requirements

Requirement SP‐34
(NG/LP) Vertical Min 6
(NG/LP) Horizontal Min 6
(NG/LP) Horizontal Max 4

Heat Shield Requirements

KOZY HEAT SP 34 Direct Vent Fireplace - Heat

The vertical vent heat shield must be installed for EVERY type of venting application.
The horizontal vent heat shield must be installed when incorporating minimum horizontal venting.

KOZY HEAT -logo

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals