KOZY HEAT Callaway 40 Direct Vent Fireplace Instructions

June 10, 2024
Kozy Heat

Callaway 40 Direct Vent Fireplace
Instructions Manual

Callaway 40 Direct Vent Fireplace

Please leave these reference guides at the installation location until the installation is finished. See owners manual for full installation and finishing instructions before making final decisions as information is subject to change.

Specifications

(all measurements are in inches)
– GAS LINE OPENING: LEFT SIDE
– ELECTRICAL ACCESS: RIGHT SIDE

Model| BTU| Height| Front Width| Back Width| Depth| Glass Viewing Area
---|---|---|---|---|---|---
Actual| Framing| Actual| Framing| Actual| Framing| Actual| Framing
CLW‐40| 31,500| 39‐1/4| 60| 49‐1/2| 56‐1/2| 49‐1/2| 56‐1/2| 18‐15/16| 22| 40 x 13

Framing Opening

If installing the Komfort Zone Kit or Heat Transfer Kit(s), please refer to the installation manual included with the corresponding kit

KOZY HEAT Callaway 40 Direct Vent Fireplace - Framing Opening
1

See the KZK‐044 or KZK‐158A manuals or Vented Cavity Installation (in the install manual) for their specific minimum dimension requirements

Dimension CLW‐40
A 57
B 56‐1/2
C 22
D 60

KOZY HEAT Callaway 40 Direct Vent Fireplace - Framing Opening
2

E F G H I J K L M
22 56‐1/2 22 56‐1/2 97‐1/2 56‐1/2 22 48‐3/4 69

Finishing Clearances

KOZY HEAT Callaway 40 Direct Vent Fireplace - Finishing
Clearances

Clearances are for STANDARD installation ONLY

Dimension CLW‐40
N 47‐7/8
O 31‐1/8
P 7‐3/8
Q 10‐1/2
R 3/4

Non‐Combustible Material Only
Combustible Material Allowed
Combustible Material Allowed
See install manual for acceptable screw location usage

Horizontal Termination Framing

KOZY HEAT Callaway 40 Direct Vent Fireplace - Horizontal Termination
Framing

Framing outlined here applies to the minimum for all standard, KZK and vented options when venting with natural draft.
If using Kozy Power Vent (#KPV), reference the manual included with the kit.

Dimension CLW‐40
S 22
T 34‐7/8

Mantel Clearances ‐ Standard Installation (NO optional Komfort Zone Heat Distribution Kit)
 ON‐COMBUSTIBLE ZONE

KOZY HEAT Callaway 40 Direct Vent Fireplace - Mantel
Clearances

No optional Decorative Surround
MANTEL PROJECTION: Each square represents 1” of projection

Dimension CLW‐40
U 9‐7/8
V 26‐5/8
W 16‐3/4
X 20‐3/8
Y 23‐7/8
Z 29‐7/8
AA 22
BB 60

KOZY HEAT Callaway 40 Direct Vent Fireplace - Linear Chimney
2

Dimension CLW‐40
CC 32‐5/8
DD 6
EE 22
FF 60

Mantel & Hearth Clearances

Komfort Zone Kit Installed (#KZK‐158A or #KZK‐044)

KOZY HEAT Callaway 40 Direct Vent Fireplace - Linear Chimney
3

Each square represents 1” of projection

Dimension CLW‐40
GG 9‐7/8
HH 26‐5/8
II 16‐3/4

Below shows where to end masonry finishing materials, when measuring from the finishing edge. This allows the installation of an Optional Surround. This is important, due to the fact that most masonry finishing materials will not fit behind the optional surround if one is installed.

KOZY HEAT Callaway 40 Direct Vent Fireplace - Mantel Clearances
2

Surround JJ KK
CW40‐RS 1‐1/2 1‐1/2
CW40‐RS4 2‐5/8 2‐5/8
CW40‐GS 6 2‐5/8
CW40‐FS 3‐1/8 3‐1/8
  • Measurement ‘JJ’ shows the space to leave on each side
  • Measurement ‘KK’ shows the space to leave on the top and the bottom

Minimum Horizontal NATURAL DRAFT Venting Requirements

KOZY HEAT Callaway 40 Direct Vent Fireplace - NATURAL
DRAFT

H = Horizontal
V = Vertical
Consult venting chart in the manual for all options above minimum requirements

Requirement CLW‐40
(NG/LP) Horizontal Min 45o Elbow + 9”
(NG/LP) Horizontal Max 24”

Minimum Vertical NATURAL DRAFT Venting Requirements

KOZY HEAT Callaway 40 Direct Vent Fireplace - NATURAL DRAFT
2

V = Vertical

Requirement CLW‐40
(NG/LP) Vertical Min 45o Elbow + 3 ft.
(NG/LP) Vertical Max 50 ft.

KOZY HEAT Callaway 40 Direct Vent Fireplace - NATURAL DRAFT
3

Requirement CLW‐40
(NG/LP) Vertical Min 45o Elbow + Reducer + 10 ft.
(NG/LP) Vertical Max 50 ft.

Class ’A’ Chimney Conversion Venting

KOZY HEAT Callaway 40 Direct Vent Fireplace - Chimney
Conversion

Requirement CLW‐40
(NG/LP) Vertical Min 45o Elbow + Reducer + Connector + 10 ft.
(NG/LP) Vertical Max 50 ft.

Coaxial to Co‐Linear Chimney Venting

KOZY HEAT Callaway 40 Direct Vent Fireplace - Linear
Chimney

Requirement CLW‐40
(NG/LP) Vertical Min 45o Elbow + Reducer + Connector + 10 ft.
(NG/LP) Vertical Max 50 ft.

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Kozy Heat User Manuals

Related Manuals