Specifications
- Model: EPS-120 series
- Power Output: 120W
- Compliance: UL62368-1, BS EN/EN62368-1, GB4943.1, IEC62368-1 TPTC004
Frequently Asked Questions
- Q: Can I use this power supply with multiple devices simultaneously?
- A: It is recommended to use the power supply with one device at a time to ensure optimal performance and safety.
- Q: What should I do if the power supply overheats?
- A: If you notice overheating, immediately disconnect the power supply from the device and power source and allow it to cool down before further use.
Product Usage Instructions
Power Supply Connection:
- Ensure the power supply is unplugged before making any connections.
- Connect the power supply to the appropriate power source following the manufacturer’s instructions.
Device Connection:
- Connect your device to the power supply using the provided cables.
- Make sure the connections are secure and properly seated.
Powering On/Off:
- To power on the supply, flip the power switch to the ON position.
- To turn off, switch it to the OFF position. Always unplug the power supply when not in use.
Safety Precautions:
- Do not expose the power supply to water or moisture.
- Keep it away from heat sources and ensure proper ventilation around the unit.
Features
- 4″x2″ miniature size
- Universal AC input / Full range
- EMI Class B for both Class I (with FG) and Class Il (without FG) configuration
- No load power consumption<0.3W
- High efficiency up to 91%
- Protections: Short circuit / Overload / Over voltage / Over temperature
- Cooling by free air convection for 84W and 120W with 10CFM forced air
- Built-in 12V/0.5A fan supply
- LED indicator for power on
- Operating altitude up to 5000 meters
- 3 years warranty
Applications
- Industrial automation machinery
- Industrial control system
- Mechanical and electrical equipment
- Electronic instruments, equipments or apparatus
GTIN CODE
- MW Search: https://www.meanwell.com/serviceGTIN.aspx
Description
EPS-120 is a 120W highly reliable green PCB type power supply with a high power density on the 4″ by 2″ footprint. It accepts 80~264VAC input and offers various output voltages between 12V and 48V. The working efficiency is up to 91% and the extremely low no load power consumption is down below 0.3W. EPS-120 is able to be used for both Class I (with FG) and Class II (no FG) system design. EPS-120 has the complete protection functions; it is complied with the international safety regulations such as TUV BS EN/EN62368-1, UL62368-1 and IEC62368-1. EPS-120 series serves as a high price-to-performance power supply solution for various industrial applications.
Model Encoding
SPECIFICATION
MODEL| EPS-120-12| EPS-120-15| EPS-120-24|
EPS-120-27| EPS-120-48
---|---|---|---|---|---
OUTPUT
| DC VOLTAGE| 12V| 15V| 24V| 27V| 48V
CURRENT
| 10CFM| 10A| 8A| 5A| 4.5A| 2.5A
Convection| 7.0A| 5.6A| 3.5A| 3.15A| 1.75A
RATED POWER| 10CFM| 120W| 120W| 120W| 121.5W| 120W
Convection| 84W| 84W| 84W| 85W| 84W
RIPPLE & NOISE (max.) **Note.2| 120mVp-p| 120mVp-p| 150mVp-p|
150mVp-p| 200mVp-p
VOLTAGE ADJ. RANGE| 11.4~12.6V| 14.3~15.8V| 22.8~25.2V| 25.6 ~ 28.4V|
45.6 ~50.4V
VOLTAGE TOLERANCE Note.3| ±2.0%| ±2.5%| ±1.0%| ±1.0%| ±1.0%
LINE REGULATION| ±0.5%| ±0.5%| ±0.5%| ±0.5%| ±0.5%
LOAD REGULATION| ±1.0%| ±1.0%| ±1.0%| ±1.0%| ±1.0%
SETUP, RISE TIME| 500ms, 30ms/230VAC 500ms, 30ms/115VAC at full
load
HOLD UP TIME (Typ.)**| 50ms/230VAC 10ms/115VAC at full load
INPUT
| VOLTAGE RANGE Note.4| 80 ~ 264VAC 113 ~ 370VDC
FREQUENCY RANGE| 47 ~ 63Hz
EFFICIENCY (Typ.)| 88%| 88.5%| 90%| 90%| 91%
AC CURRENT (Typ.)| 2.1A/115VAC 1.2A/230VAC
INRUSH CURRENT (Typ.)| COLD START 30A/115VAC 60A/230VAC
LEAKAGE CURRENT| <0.75mA / 240VAC
PROTECTION
| ****
OVERLOAD
| 115~150% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is
removed
OVER VOLTAGE
| 13.2 ~ 15.6V| 16.5 ~ 19.5V| 26.4 ~ 31.2V| 29.7 ~ 35V| 52.8 ~ 62.4V
Protection type : Shut down o/p voltage, re-power on to recover
OVER TEMPERATURE| Protection type : Shut down o/p voltage, re-power on
to recover
FUNCTION| FAN SUPPLY| 12V@0.5A for driving a fan ; tolerance -15% ~
+10% at main output 40% rated current (10CFM)
ENVIRONMENT
| WORKING TEMP.| -30 ~ +70℃ (Refer to “Derating Curve”)
WORKING HUMIDITY| 20 ~ 90% RH non-condensing
STORAGE TEMP., HUMIDITY| -40 ~ +85℃, 10 ~ 95% RH
TEMP. COEFFICIENT| ±0.03%/℃ (0 ~ 50℃)
OPERATING ALTITUDE Note.6| 5000 meters
VIBRATION| 10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes
SAFETY & EMC
(Note 5)
| SAFETY STANDARDS| UL62368-1, TUV BS EN/EN62368-1, IEC62368-1, CCC
GB4943.1, EAC TP TC 004 approved
WITHSTAND VOLTAGE| I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC
ISOLATION RESISTANCE| I/P-O/P, I/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH
EMC EMISSION| Compliance to BS EN/EN55032 (CISPR32) Class B, BS
EN/EN61000-3-2,-3, GB9254.1 Class B,GB17625 Class A, EAC TP TC 020
EMC IMMUNITY
| Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11, BS EN/EN55035, BS EN/EN61000-6-2, heavy industry level, criteria A, EAC TP TC 020
OTHERS
| MTBF| 3746.9K hrs min. Telcordia SR-332 (Bellcore) ; 491.2K hrs
min. MIL-HDBK-217F (25℃)
DIMENSION| 101.650.829mm (LWH)
PACKING| 0.15Kg; 72pcs/11.8Kg/0.82CUFT
NOTE| 1. All parameters NOT specially mentioned are measured at 230VAC
input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12″ twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance: includes set up tolerance, line regulation and load regulation.
4. Derating may be needed under low input voltages. Please check the derating curve for more details.
5. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on a 360mm*360mm metal plate with 1mm of thickness. The final equipment must be re- confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.” (as available on http://www.meanwell.com)
6. The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitude higher than 2000m(6500ft).
※ Product Liability Disclaimer: For detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx
Diagrams
Block Diagram
Derating Curve
Output Derating VS Input Voltage
Mechanical Specification
AC Input Connector (CN1): JST B3P-VH or equivalent
Pin No. | Assignment | Mating Housing | Terminal |
---|---|---|---|
1 | AC/N | JST VHR or equivalent | JST SVH-21T-P1.1 or equivalent |
2 | No Pin | ||
3 | AC/L |
: Grounding required
- HS1,HS2 cannot be shorted.
- HS1 must have safety isolation distance with system case.
DC Output Connector (CN2): JST B4P-VH or equivalent
Pin No. | Assignment | Mating Housing | Terminal |
---|---|---|---|
1,2 | +V | JST VHR or equivalent | JST SVH-21T-P1.1 or equivalent |
3,4 | -V |
FAN Connector(CN101): JST B2B-PH-K-S or equivalent
Pin No. | Assignment | Mating Housing | Terminal |
---|---|---|---|
1 | +12V | JST PHR-2 or equivalent | JST SPH-002T-P0.5S or equivalent |
2 | DC COM |
Note
- The FAN SUPPLY is designed to serve as the source of the additive external fan for the cooling of the power supply, enabling the full load delivery and assuring the best life span of the product. Please do not use this FAN SUPPLY to drive other devices.
- The PCB type(Blank type)model delivers EMI Class B for both conducted emission and radiated emission for the power supply, when configured into either ClassⅠ(with FG) or ClassⅡ(without FG) system.
Installation Manual
Please refer to: http://www.meanwell.com/manual.html
User’s Manual
Documents / Resources
| MEAN
WELL EPS-120-12 120W Single Output Switching Power
Supply
[pdf] Instructions
EPS-120-12 120W Single Output Switching Power Supply, EPS-120-12, 120W Single
Output Switching Power Supply, Output Switching Power Supply, Switching Power
Supply, Power Supply, Supply
---|---
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>