COMFIER BSX976 Infrared Thermometer Instruction Manual

June 9, 2024
COMFIER

BSX976 Infrared Thermometer
Instruction Manual

Foreword

Thank you for purchasing the infrared Thermometer.
The Infrared Thermometer is a high quality product incorporating the latest technology and tested in accordance with international standards. With its unique technology, th  Infrared Thermometer can provide a stable, heat- interference  free reading with each measurement infrared thermometer shows the temperature of the subject by measur the heat radiation from the forehead.
Some Helpful Guidelines For Best Results When Using the Infrared Thermometer

  • Call your doctor when your child has diarrhea, vomiting or changes in appetite, lethargy (sluggishness)or is unusually sleep
  • It is important to know each individual’s normal temperature when they are wel This is the only way to accurately diagnoses fever. Take multiple readings when healthy to determine normal temperature
  • A child’s normal temperature can beas highas 377Colas l0was361¢ fe.measure with standard digital thermometer for conformation,especially on infants (/tis recommended to use a digital thermometer rectal/y on infants ad on sleeping infants if there ls a question about the measurement Be sure to note this unit  reads  Cower than a rectal digital measurement)

This productisa Class medical device and belongs to the internal power supply equipment, type BF application part, the protection grade is ordinary equipment, nor- AP/APG, intermittent operation equipment, the EU is classifiedas Class lalease read these instructions carefully before using this instrument andkeep the instructions and  the thermometer inasafe place

Advantaged of the infrared Thermometer

  1. Advantages of the Infrared Thermometer

Quick Measurement

The infrared technology allows measurement of body temperature in within 3 seconds.

Appropriate Medical Application

The infrared thermometer provides either forehead or Object temperature mode.The range of the forehead temperature is from (32.0-43.0)°C 1(93.2-109.4)°F and for the Object temperature is (5.0-95.0)°C 1(41.0-203.0)°F which can meet the application demands normally.

Accurate and Reliable Measurement

Due to the unique probe assembly construction, the advanced infrared sensor, and the complete calibration process this unit can offer a very accurate and reliable temperature measurement comparable to one taken from the oral site with a regular digital thermometer.

Gentle and Easy to Use

  • The Infrared Thermometer is non-invasive. A measurement can be taken even while a child is sleeping.
  • Design is easy to hold and use.
  • The Infrared Thermometer is less threatening to a child than a rectal thermometer and easier to use than other methods.

Multiple Reading Recordings
Users can record the last 20 readings when entering the Memory`” Tracker recall mode, enabling efficient tracking of temperature history and variations.

Safe and Hygienic

  • No risk of broken glass or mercury ingestion.
  • Completely safe for use on children.

Fever Indications
When the measurement reading exceeds 38.0°C (100.4°F), please go to the hospital for medical examination as soon as possible.

  1. How the Infrared Thermometer Measures Body Temperature Objects in the nature radiates infrared rays if it, s temperature above absolute zero (-270 °C). The energy of the its rays and temperature are proportional. With this relationship, The infrared thermometer calculates the temperature by measuring the infrared radiation intensity of the object.

Intended Use/Indications for Use
Infrared thermometer shows the temperature of the subject by measuring the heat radiation from the forehead. It is suitable for people of all ages.
The Infrared thermometer is intended for both professional and consumer, the patient is the intended operator.

Important Safety Instructions

  • Never use the thermometer for purposes other than those it has been intended for. Please follow the general safety precautions when using on children.
  • Never immerse the Infrared Thermometer into water or other liquids (not waterproof).
  • For cleaning and disinfecting please follow the instructions in the “Cleaning and Storage” section.
  • Keep the instrument away from direct exposure to the sun and keep it in a dust-free, dry area at the temperature between (15­40)°C.
  • Do not use the thermometer if there are signs of damage on the measuring sensor or on the instrument itself. If damaged, do not attempt to repair the instrument! Please contact the dealer.
  • This Infrared Thermometer consists of high-quality precision Do not drop the instrument. Protect it from severe impact and shock. Do not twist the instrument or the measuring sensor, otherwise it will not be able to measure body temperature accurately or unable to measure body temperature.

WARNING:

  • Use of this Infrared Thermometer is not intended as a substitute for consultation with your physician or paediatrician.
  • Thermometer is not waterproof! NEVER immerse into liquids!
  • Please consult your doctor if you see symptoms such as unexplained irritability, vomiting, diarrhea, dehydration, changes in appetite or activity, seizure, muscle pain, shivering, stiff neck, pain when urinating, etc., even in the absence of fever or who exhibits a normal temperature, may still need to receive medical
  • People who are on antibiotics, analgesics, or antipyretics should not be assessed solely on temperature readings to determine the severity of their illness.
  • Temperature elevation may signal a serious illness, especially in adults who are old, frail, have a weakened immune system, or neonates and infants. Please seek professional advice immediately when there is a temperature elevation and if you are taking temperature for whom are:
  • Neonates and infants under 3 months;
  • Over 60 years of age;
  • Having diabetes mellitus or a weakened immune system (e.g. HIV positive, cancer chemotherapy, chronic steroid treatment, splenectomy).
  • Bedridden (e.g. nursing home patient, stroke, chronic illness, recovering from surgery)

A transplant patient (e.g. liver, heart, lung, kidney)

  • Fever may be blunted or even absent in elderly patients.
  • This thermometer is not intended for pre-term babies or small­for-gestational age babies. This thermometer is not intended to interpret hypothermic temperatures.
  • Do not allow children to take their temperatures unattended.
  • Do not modify this equipment without authorization of
  • Please do not service and maintain thermometer when it is in use, for example replacing the battery, place something on the forehead etc.
  • This product contains small parts such as(batteries, battery cover and screws)that may cause suffocation if swallowed by

PRECAUTIONS:
To avoid an inaccurate measurement, note the following:

  • 1 hour is required for the infrared thermometer to warm from the minimum storage temperature between uses until the infrared thermometer is ready for its INTENDED USE when the ambient temperature is 20 °C;

  • 1 hour is required for the 1 hour is to cool from the maximum storage temperature between uses until the 1 hour is ready for its INTENDED USE when the ambient temperature is 20 °C;

  • Before and after use, please keep the sensor and probe cavity clean;

  • Please use the thermometer in a stable temperature When the ambient temperature fluctuates greatly (from indoor to outdoor), please leave it for about half an hour to measure;

  • Do not start measuring body temperature immediately after measuring extremely high or low temperature, please leave it for ten minutes to measure;

  • Patients should stay in steady – state room condition for at least 30 minutes.

  • Don’t remove the measurement device from the measuring area before hearing the final beep.

  • Don’t take a measurement while or immediately after nursing a

  • Don’t use the Infrared thermometer in high humidity

  • Patients should not drink, eat, or be physically active before/while taking the measurement.

  • Before placing the thermometer sensor onto the measurement area, remove dirt, hair, or sweat.

  • Always take the temperature in the same location, since the
    temperature readings may vary from different locations.

  • In the following situations it is recommended that three temperatures in the same location be taken and the highest one

Product Description

COMFIER BSX976 Infrared Thermometer - Figure 1

The above picture is only for reference. Please use the material object as standard.

  • Start button: Measuring the forehead temperature and objects
  • Setting: This product supports total four settings options, which are temperature unit, operating sound, fever indication point, temperature offsets.
  • Memory button: Read the 20 measured data lately.

Installation and Use

6.1 Initial settings

6.1.1 Battery installation

Install new battery

  1. Pull out the battery cover on the bottom of the
  2. Install two “AAA” batteries correctly, and pay attention to the direction of the battery’s positive and negative electrodes.
  3. Close the battery cover(as the picture below).

Warning:

  1. Please do not use this thermometer in flammable and explosive anesthetic gas, oxygen, nitrous oxide, etc.
  2. To ensure the performance accuracy of this product and prevent equipment failure, please do not use it in a humid place.
  3. Caution: Do not install waste batteries on the thermometer and do not input external power.
  4. When not in use for a long time, please remove the battery to prevent leakage.
  5. Never dispose of waste batteries in fire.
  6. Please properly dispose of used batteries in accordance with local regulations to avoid contamination.

6.2 Measurement Instructions
6.2.1 Body temperature

  1. Short press the start button to turn on, all the icons are displayed on the screen, the buzzer two beeps to complete the self-test, and enter the temperature measurement state.

  2. Point the thermometer to the center of human forehead in straight angle,at a distance of 0-3 cm.ln about half a second user may hear the sound”beep” and see the temperature value.The measurement is done.
    After the measurement is done, if there is no operation within 30 seconds, it will aut-omatically shut down.

  3. Read the recorded temperature from the LCD display.

NOTE:

  1. Before and after use, please keep the sensor and probe cavity clean;
  2. Please use the thermometer in a stable temperature When the ambient temperature fluctuates greatly (from indoor to outdoor), please leave it for about half an hour to measure;
  3. Do not start measuring body temperature immediately after measuring extremely high or low temperature, please leave it for ten minutes to measure;
  4. When the measurement object comes from a place with a large temperature difference from the measurement environment, it should stay in the test environment for at least half an hour;
  5. Try not to measure with forehead blown, dripping, sweating, or applying cosmetics.
  6. Do not test body temperature within 30 minutes after exercise, bathing, or eating.

6.2.2 Objects temperature

  1. Short press the start button to turn on, all the icons are displayed on the screen, the buzzer two beeps to complete the self-test, and enter the temperature measurement state.
  2. Point the thermometer straight to the object surface under test at a distance of 0-3 cm.Press the Start button, and in about half and the measurement is done.

NOTE:

  1. The temperature here refers to only the surface temperature of the object under test, not its core temperature;
  2. The infrared ray radiation rate of different materials varies, which may affect the measurement results. The defaulted radiation rate of this device is 0.95. For example, the measured temperature of stainless steel may be much lower than the actual temperature. Please take care to prevent from getting burned in such case.

6.3 Function settings
This product supports total five settings options, such as temperature unit, operating sound, fever indication point, temperature offsets and measurement mode.

Warranty

If you have any issue about the product, please feel free to contact us by sending email to supportus@comfier.com We will strive to provide the best service possible within 24 hours.

30 days unconditionally Return
Comfier product can be returned to receive a full refund for any reason within 30 days. Please contact our customers service (supportus@comfiercom), our staff will contact you within 24 hours.
90 days refund/replace
Comfier product can be returned / replaced within 90 days if the product break down in the period of proper use.
12 months Warranty
If the product break down within 12 months in the period of proper use, customers can enjoy the relevant warranty to get them replaced.
Attention!
No warranty will be given to any force majeure and man-made causes to a defective product, such as improper care, personal tear down and willful damage,etc.
Extend Warranty for Free

  1. Enter the following URL or scan the QR code below to find COMFIER facebook page and like it, enter”Warranty” to messenger to extend your warranty from 1 year to 3 years.

https://www.facebook.com/comfiermassager

OR 2) Send message”Warranty” and email us supportus@comfier.com to extend your warranty from 1 year to 3 years.

Have question ?
Tel:248-819-2623
Monday-Friday 9:00AM-4:30PM
Email: supportus@comfier.com

COMFIER TECHNOLOGY CO.,LTD.
Address:573 BELLEVUE RD
NEWARK, DE 19713 USA
www.facebook.com/comfiermassager
supportus@comfier.com
www.comfier.com

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals