KEONJINN JG-01 Bathroom LED Medicine Cabinet Instruction Manual

June 17, 2024
KEONJINN

KEONJINN JG-01 Bathroom LED Medicine Cabinet

Product Specifications

  • Dimensions:
    • 20×26
    • 20×32
    • 24×32
    • 30×26
    • 30×32
    • 36×32
    • 40×32
    • 48×32
  • Material : Tempered Glass Plate
  • Number of Shelves : 2, 3, 6
  • Components included : Lower Bracket, Upper Bracket, Shelf Clips, Spout Plug, Anchors, Screws

Product Usage Instructions

Inspection and Setup

Upon receipt, inspect the product for any damage or missing parts. Contact customer support if needed.

Electrical Safety

Ensure the product is used within the voltage range of 100V-120V. Use electrical tape to prevent leakage. Connect wires to a junction box or plug.

Cleaning Instructions

Use a soft, non-abrasive cloth to clean the mirror. Avoid harsh materials and cleaning agents that may damage the surface.

Warranty

A one-year warranty is provided from the date of purchase.

FAQ

  • Q: How do I adjust the brightness of the mirror?
    • A : The button on the mirror controls the light switch and brightness. Tap to turn on/off and long-press to adjust brightness.
  • Q: What is the purpose of the anti-fog function?
    • A : The anti-fog function helps keep the mirror clear from fog for a better reflection image. It automatically turns off after one hour to save energy.
  • Q: How should I hang the cabinet in relation to the faucet?
    • A : Hang the cabinet at least 3 inches above the faucet to avoid water damage.
  • Q: What tools are needed for installation?
    • A : Tools required include a marker, hammer, tape measure, electric drill, Phillips screwdriver, and safety goggles.

HOW TO USE AND CLEAN

In order to keep the LED mirror in perfect condition, we suggest a proper use and regular cleaning.

How to Use

  • Please ensure that the product is used within the safe voltage range of 100V-120V.
  • Please wrap electrical tape around the wires to prevent electrical leakage.
  • Avoid using hard or pointed items to strike the mirror glass so as to prevent damage.

How to Clean

When cleaning the mirror, please follow these steps:

  • Use a soft, non-abrasive cloth to clean the mirror. Avoid using rough or abrasive materials that may damage the surface.
  • Do not use any cleaning agents that may cause irritation or damage to the mirror’s finish. Instead, use any of the recommended cleansers to remove dirt and grime.

Warranty
A one-year warranty from the date of your purchase.

PACKING LIST

KEONJINN-JG-01-Bathroom-LED-Medicine-Cabinet-FIG1

BEFORE INSTALLATION

Thank you for choosing our products. To ensure the best experience, please read carefully and follow the instructions provided below before assembling and installing the product.

Important Safety Instructions

  • Assembly by two or more adults is highly recommended, so as to ensure proper installation.
  • To connect the wires to the electrical junction box, a qualified technician or electrician is highly recommended.
  • Disconnect power before installing, adding, or changing any components.
  • Make sure that the fixing location can support the weight of the entire fixture (e.g. solid stone or brick walls).
  • To prevent injury, the mirror must be installed as per the instructions provided.
  • The medicine cabinet should be installed on a wood panel wall thicker than 16mm, or a concrete wall thicker than 8mm.

Pre-assembly

  • Inspect the product immediately upon receipt for any transit damage or missing parts.
  • The voltage for your product should be between 100V and 120V. If the voltage exceeds 120V, please use a transformer.
  • You can connect the wires directly to your junction box or plug.

Before Installation

  • Please check and make sure that the mirror is functioning properly.

KEONJINN-JG-01-Bathroom-LED-Medicine-Cabinet-FIG2

ON/OFF/ Brightness

The button controls the light switch and brightness. Tap the button to turn on the light and tap again to turn it off. The brightness can be adjusted with a long press on the button. After turning off the mirror light, you can turn off the light of the touch switch as well by long pressing the ON/OFF button.

Anti-fog

The anti-fog function helps resist the troubling fog and keeps a clear reflection image. To save energy, it will automatically turn off after one hour. By following these steps, you can ensure that your mirror is working properly before installation. If there are any problems, please contact us for support.

INSTALLATION

  • Installation Tools

KEONJINN-JG-01-Bathroom-LED-Medicine-Cabinet-FIG5

Before installation

KEONJINN-JG-01-Bathroom-LED-Medicine-Cabinet-FIG6

  1. Before installation, release the cable that connects the door and the cabinet (1). Press the lever under the hydraulic hinge (2), detach, and slide the door to the frame (2)).KEONJINN-JG-01-Bathroom-LED-Medicine-Cabinet-FIG6KEONJINN-JG-01-Bathroom-LED-Medicine-Cabinet-FIG7
  2. Place the medicine cabinet against the wall and mark the placement of the cabinet. Draw a line on the wall with a level and marker to indicate where the cabinet bottom is and mark snots (12)) for the lower brackets
  3. Use an electric drill to punch holes at the marked spots (1), then apply the 4 wall anchors with a hammer (2).
  4. Place the medicine cabinet securely onto the lower bracket and hold it upright (1). Secure two upper brackets in the groove on top of the cabinet (2) and mark the spots on the wall (3).
  5. Use an electric drill to punch holes at the marked spots (1), secure the upper brackets in the groove (2), and mount them to the wall with screws 1(3).KEONJINN-JG-01-Bathroom-LED-Medicine-Cabinet-FIG8
  6. Connect the power. You can use the plug directly or connect the wire to a standard switch lighting circuit.
  7. Insert the provided shelf clips into the round holes on both sides of the cabinet (1). After installing the shelf clips, insert the glass shelve (2).
  8. Attach the cabinet door back after installing the shelves (1) plug the cable back to the top of the cabinet and screw it securely (2).

HOW TO ADJUST HYDRAULIC HINGES

Open the “DTC” cover in the direction of the arrow.

  • Turn screw I to adjust the depth of the door overlay;
  • Turn front screw 2) to adjust the gap between the door and cabinet;
  • Turn the eccentric screw 3) to release the mounting plate from the cabinet, allowing the door to be moved up and down.

CONTACT US

After opening the package, please inspect the product immediately and see if there is any damage or missing parts. If there is, please feel free to contact us by CRM@ZRItechservice.com, and we will reply within 24 hours.

If you have any questions, please feel free to contact us on CRM@ZRItechservice.com

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>