KEONJINN Acrylic Framed LED Mirror Installation Guide
- June 17, 2024
- KEONJINN
Table of Contents
KEONJINN Acrylic Framed LED Mirror
Contact Us
After opening the package, please inspect the product immediately and see if there is any damage or missing parts. If there is, please feel free to contact us by sales@keonjinn.com or find us at Amazon by following steps:
- Open “Orders” at Amazon, find the product you have purchased and open the product page;
- Click Sold by “Keonjinn”, and click “Ask a question” on the redirected page ;
- Click “An order I have placed” in the chat with Seller Messaging Assistant ;
- Click in sequence “Your product”, “Other”, and “Troubleshooting” from available options, you will see a message box after that.
Please leave us a message, and we will reply within 24 hours.
Packing List
Instructions For Use
- Please ensure that the product is used within the safe voltage range of 100V-120V.
- Please wrap electrical tape around the wires to prevent electrical leakage.
- Avoid using hard or pointed items to strike the mirror glass so as to prevent damage.
Before Installation
Thank you for choosing Keonjinn products. To ensure the best experience, please read carefully and follow the instructions provided below before assembling and installing the product.
Important Safety Instructions:
- Assemble the product by two or more adults to ensure proper installation.
- To connect the wires to the electrical junction box, a qualified technician or electrician is highly recommended.
- Disconnect power before installing, adding, or changing any components.
- Make sure that the fixing location can support the weight of the entire fixture (e.g. solid stone or brick walls).
- To prevent injury, the mirror must be installed according to the instructions provided.
Pre-assembly:
- Inspect the product immediately upon receipt for any transit damage or missing parts.
- The voltage for your Keonjinn product should be between 100V and 120V. If the voltage exceeds 120V, please use a transformer.
- You can connect the wires directly to your junction box or plug.
Before installation
Please check and make sure that the mirror is functioning properly.
Anti-fog and Radar Motion Sensor Switch
- Single click to turn ON/OFF the defogging function. To prevent the mirror from overheating and save energy, it will automatically turn off after one hour.
- Double click to turn ON/OFF the radar sensor, and the light of radar sensor indicator will be ON/OFF accordingly. The radar sensor also features a memory function, which enables it to remember its last setting (ON or OFF) before the power is cut off.
ON/OFF, Brightness Control, and Color Temperature Selection
- Single click to turn the light ON/OFF.
- Press and hold the button to adjust the brightness.
- Double click to select among three color temperatures.
With the memory function, it will remain the same brightness and color temperature as the last settings before it was turned off.
Radar Motion Sensor Indicator
- The ON/OFF of the light of the button indicates whether the radar sensor is working or not. The light will be automatically on when the radar detecting the presence, stationary and moving of human within a range of 3.6-4.25 ft, and will be off 30 seconds later after this person walk away.
Note: The ON/OFF of radar sensor is not controlled by this button, but by double clicking the radar motion sensor switch at the rightmost.
Installation Instructions
Tools Required
-
Decide the installation method as per your reference. Confirm the locations for drilling holes with the positioning ruler, and use a marker to mark the spots CD@®@ on the wall.
NOTE: Please hang the mirror a few inches above the highest part of the faucet.
How to Use the Positioning Ruler: The positioning ruler makes it easier for you to drill perfect holes for the brackets. -
Decide the location to hang your mirror first, and make sure the positioning ruler is placed against the wall horizontally.
-
The lower line is product size. According to your product size, you can find the corresponding hole spots for the two brackets, which are indicated on the upper line.
-
Use an electric drill to punch holes at the marked spots, and then apply wall anchors with a hammer.
-
Secure the two brackets to the wall with screws.
-
Connect the power. You can use the plug directly or connect the wire to a standard switch lighting circuit.
Plug-in
Before hanging the mirror securely, plug the power cable to a standard socket.
Hardwired:- Cut the head off the plug and hardwire it into an outlet.
- Black wire — power supply L(LIVE)
- White wire — power supply N(NEUTRAL)
- Green wire — power supply E (EARTH)
- WARNING: This mirror must be earthed.
Reminder: Please make sure the power .. is cut off before installation.
WARNING : This mirror must be earthed.
- Place the mirror against the wall, align the hook with the mounted bracket, slowly lower the mirror down, and make sure that it slots into the right position and hangs securely.
Specifications
Size | Dimension | Types of Medicine Cabinet |
---|---|---|
24″ X 36″ | 61 x 91 x 3.6 cm | 36W |
28″ X 36″ | 71 x 91 x 3.6 cm | 36W |
30″ X 36″ | 76 x 91 x 3.6 cm | 36W |
36″ X 36″ | 91 x 91 x 3.6 cm | 36W |
40″ X 24″ | 101 x 61 x 3.6 cm | 36W |
40″ X 32″ | 101 x 81 x 3.6 cm | 36W |
48″ X 30″ | 121 x 76 x 3.6 cm | 48W |
48″ X 36″ | 121 x 91 x 3.6 cm | 48W |
55″ X 36″ | 139 x 91 x 3.6 cm | 48W |
60″ X 36″ | 152 x 91 x 3.6 cm | 48W |
71″ X 36″ | 180 x 90 x 3.6 cm | 60W |
PARAMETER | SPECIFICATION | |
--- | --- | |
Color Temperature | 3000K-6000K | |
Input Voltage | AC100-120V | |
Output Voltage | 12VDC | |
CRI | ;;;;go Ra | |
Working Temperature | -20-45°( | |
Life Span | 50000 hours | |
Anti-fog | Yes | |
IP Rate | IP44 | |
Wiring Method | Hardwired/ Plug In | |
Switch | Touch Sensor & Microwave Inductive |
Warranty: 2 years from the date of purchase