HITACHI R410A Series Ducted Indoor Units Instruction Manual

May 14, 2024
Hitachi

HITACHI-LOGO

HITACHI R410A Series Ducted Indoor Units

HITACHI-R410A-Series-Ducted-Indoor-Units-PRODUCT-IMAGE

Specifications

  • Model : RPIL-(0.4-1.5)FSRE
  • Refrigerants : R32/R410A
  • Revision : PMML0527 rev.3 – 07/2021

Product Usage Instructions

Installation

  1. Ensure the unit is powered off before installation.
  2.  Follow the provided installation manual for proper placement and mounting of the unit.
  3. Connect the necessary ductwork according to the specifications.

Operation

  1. Power on the unit using the designated controls.
  2. Set the desired temperature and fan speed using the remote control.
  3. Monitor the unit for any unusual noises or malfunctions during operation.

Maintenance

  1. Regularly clean or replace air filters to ensure optimal performance.
  2. Schedule professional maintenance checks at least once a year.
  3.  Keep the outdoor unit free from debris and obstructions.

FAQ

  • Q: How often should I clean the air filters?
    A: It is recommended to clean or replace the air filters every 1-2 months depending on usage.

  • Q: Can I install the unit myself?
    A: Installation must be done by a professional installer to ensure proper setup and safety.

  • Q: What should I do if the unit is making unusual noises?
    A: Turn off the unit immediately and contact a certified technician for inspection and repairs.

DUCTED INDOOR UNITS
R32/R410A SERIES

INSTALLATION AND OPERATION MANUAL

HITACHI-R410A-Series-Ducted-Indoor-
Units- \(1\)

  • Specifications in this manual are subject to change without notice in order that Hitachi may bring the latest innovations to their customers.
  • Whilst every effort is made to ensure that all specifications are correct, printing errors are beyond Hitachi’s control; Hitachi cannot be held responsible for these errors.

CAUTION
This product shall not be mixed with general house waste at the end of its life and it shall be retired according to the appropriated local or national regulations in a environmentally correct way.
Due to the refrigerant, oil and other components contained in Air Conditioner, its dismantling must be done by a professional installer according to the applicable regulations. Contact to the corresponding authorities for more information.
The English version is the original one; other languages are translated from English. Should any discrepancy occur between the English and the translated versions, the English version shall pre-vail.

Original Version

WARNING

  • BURST HAZARD
    Do not allow air or any gas mixture containing oxygen into refriger-ant cycle (i.e. piping)

  • WARNING
    This symbol displayed on the unit indicates that this appliance is filled with R32, an odourless flammable refrigerant gas with low burning velocity (A2L class pursuant to ISO 817). If the refrigerant is leaked, there is a possibility of ignition if it enters in contact with an external ignition source.

  • HITACHI-R410A-Series-Ducted-Indoor-Units- \(9\)CAUTION
    This symbol displayed on the unit indicates that this appliance shall be handled by authorized service personnel only, referring to the  Installation Manual.

  • CAUTION

This symbol displayed on the unit indicates that there is relevant information included in the Operation Manual and/or Installation  Manual.

  • CAUTION

For more information, see the Installation and Operation Manual.

RISK OF EXPLOSION
The compressor must be stopped before removing the refrigerant pipes.
All service valves must be fully closed after pumping down operation.

  • Make sure that unit installation and refrigerant piping installation comply with applicable legislation in each country. Also, in Europe, EN378 must be complied, as it is the applicable standard.
  • The supplementary information about the purchased products is supplied in a CD-ROM, which can be found bundled with the outdoor unit. In case that the CD-ROM is missing or it is not readable, please contact your HITACHI dealer or distributor.
  •  PLEASE READ MANUALS AND THE FILES ON THE CD-ROM CAREFULLY BEFORE STARTING WORK ON THE INSTALLATION OF THE AIR CONDITIONING SYSTEM. Failure to observethe instructions for installation, use and operation described in this documentation may result in operating failure including potentially serious faults, or even the destruction of the air conditioning system.
  • Verify, in accordance with the manuals which appear in the outdoor and indoor units, that all the information required for the correct installation of the system is included. If this is not the case, contact your distributor.
Indoor Unit Outdoor Unit
Installation and operation manual Installation manual

CD-ROM
Additional safety manual for R32 refrigerant air conditioner and heat pump according to IEC 60335-2-40:2018

R32 Refrigerant circuit
The unit installation and refrigerant piping should comply with the relevant local and national regulations for the designed refrigerant.
Due to R32 refrigerant and depending on final refrigerant charge amount, a minimum floor area for installation must be considered.

  • If total refrigerant charge amount <1.84kg, there are no additional minimum floor area requirements.
  • If total refrigerant charge amount ≥1.84kg, there are additional minimum floor area requirements to be checked.

Minimum area requirements

In case of total refrigerant amount ≥1.84 kg, the unit should be installed, operated and stored in a room with a floor area larger than the minimum criteria. Use following graphic and table to determine these minimum criteria.

NOTE

  • In case of not achieving the minimum floor area, contact with your dealer.
  • For further information about refrigerant charge refer to the Outdoor
  • Unit Installation Manual.

Refrigerant Amount

HITACHI-R410A-Series-Ducted-Indoor-Units- \(10\)

Minimum room area for installation

HITACHI-R410A-Series-Ducted-Indoor-Units- \(11\)

Total refrigerant amount in the system

DANGER

  • Check to ensure that the number of below is within 0.44kg/m3. Otherwise it may cause danger situation if the refrigerant in the outdoor unit leaks into the room where this indoor unit is installed.
  • (Total refrigerant quantity per one outdoor unit) ≤0.44kg/m3
  • (Volume of the room where this indoor unit is installed) For detail, refer to the Installation Manual for outdoor unit.
  • Make sure that the refrigerant leakage test should be performed. The refrigerant (Fluorocarbon R410A) for this unit is incombustible, non-toxic and odorless. However if the refrigerant is leaked and is contacted with fire, toxic gas will generate. Also because the fluorocarbon is heavier than air, the floor surface will be filled with it, which could cause suffocation.
  • Use the specified non-flammable refrigerant (R410A) to the outdoor unit in the refrigerant cycle. Do not charge material other than R410A into the unit such as hydrocarbon refrigerants (propane or etc.), oxygen, flammable gases (acetylene, etc.) or poisonous gases when in-stalling, maintaining and moving. These flammables are extremely dangerous and may cause an explosion, a fire, and injury.

Johnson Controls-Hitachi Air Conditioning Spain, S.A.U.

  • Ronda Shimizu, 1 – Políg. Ind. Can Torralba
  • 08233 Vacarisses (Barcelona) Spain
  • © Copyright 2021 Johnson Controls-Hitachi Air Conditioning Spain, S.A.U. – All rights reserved.HITACHI-R410A-Series-Ducted-Indoor-Units- \(8\)

Printed in Spain

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals