signify ZF4RDL EasyLyte Flex Down Lighting Instruction Manual

June 17, 2024
signify

signify ZF4RDL EasyLyte Flex Down Lighting

signify-ZF4RDL-EasyLyte-Flex-Down-Lighting-product

Specifications

  • Product Name: EasyLyte Flex Downlighting
  • Model Numbers: ZF4RDL and ZF6RDL
  • Sizes: 4” and 6” Round downlight
  • Manufacturer: Signify

Product Usage Instructions

Caution and Safety

CAUTION: THE INSTALLATION AND SERVICING OF THIS PRODUCT SHOULD BE PERFORMED BY A QUALIFIED ELECTRICIAN OR SERVICE PERSONNEL. Read and understand these instructions before installing the luminaire.

To ensure safety, follow all local electrical codes and regulations. Turn off electricity at the fuse box before proceeding with installation. Allow the fixture to cool before handling.

Installation Steps:

  • Step 1: Cut Ceiling Opening
    • Cut an opening in the ceiling as per the provided dimensions for the remodeler. Ensure there are no obstructions in the ceiling.
  • Step 2: Wire Connection
    • Connect the wires to the supply leads – white wire to neutral, black wire to hot, and bare copper/green wire to ground. Use wire nuts for connections and place them in the j-box.
  • Step 3: Install Driver and Trim
    • Feed the driver from the light engine through the aperture hole in the ceiling. Squeeze the trim springs while pushing the trim reflector up into the ceiling cutout. Adjust as needed.

Frequently Asked Questions

  • Q: Can I use trims from other manufacturers with this downlight?
    • A: No, it is recommended to only use LED light engines and reflector trims provided by Signify to maintain safety and compliance with regulations.
  • Q: How do I remove the trim for maintenance?
    • A: The trim can be removed by grasping the reflector flange and pulling it straight down.

INSTRUCTION

CAUTION: THE INSTALLATION AND SERVICING OF THIS PRODUCT SHOULD BE PERFORMED BY A QUALIFIED ELECTRICIAN OR SERVICE PERSONNEL

NOTE: This equipment has been tested and found to comply with the limits for a Class A digital service, under Part 15 of the FFC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used by the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.

Read and understand these instructions before installing the luminaire (fixture)

This luminaire is intended for installation by the National Electrical Code and local regulations. To ensure full compliance with local codes and regulations, check with your local electrical inspector before installation. To prevent electrical shock, turn off the electricity at the fuse box before proceeding. Allow mixture to cool before handling.

Retain these instructions for maintenance reference

Installation for

  • ZF4RDL
  • ZF6RDL

Caution (RISK OF FIRE)

Use only with LED light engines and reflector Trims provided by Signify. Use of other manufacturers’ trims may void the Underwriters Laboratories listing and could constitute a fire hazard.

INSTALLATION

Step 1
Cut an opening in the ceiling to accommodate the remodeler to be installed as shown in figure 1. Ensure that there is nothing in the ceiling to obstruct the installation.signify-ZF4RDL-EasyLyte-Flex-Down-Lighting-fig
\(2\)

Note: For 4” Series use 4.5” and 6’’ use 6.5’’ Hole Cutout

Step 2
Wire to supply leads. White wire to neutral supply lead, black wire to hot supply lead, and bare copper and/or green wire must be connected to supply ground. Use wire nuts (local hardware item). Place all electrical connections in the J-box and close the J-box door.signify-ZF4RDL-EasyLyte-Flex-Down-
Lighting-fig \(3\)

Note: For luminaires with 0-10V dimming, or digital dimming, wire violet and pink leads to appropriate control.

Step 3
Feed Driver from Light Engine through the aperture hole in the ceiling. Squeeze the two Trim Springs upward while pushing the Trim Reflector up into the ceiling cutout. As shown in figure 2 and figure 3.
Note: Trim can be removed by grasping the reflector flange and pulling straight down.signify-ZF4RDL-EasyLyte-Flex-Down-Lighting-fig
\(4\)

2019 Signify Holding. All rights reserved. This document may be subject to change. No representation or warranty as to the accuracy or completeness of the information included herein is given and any liability for any action in reliance thereon is disclaimed. All trademarks are owned by Signify Holding or their respective owners. Signify North America Corporation

  • 400 Franklin Square Drive, Somerset, NJ 08873
  • Telephone 855-486-2216

Signify Canada Ltd.

  • 281 Hillmount Road.
  • Markham, ON, Canada L6C 2S€
  • Telephone 800-668-9008