American Standard 7390.723 Bidet Faucet and Tranfer Valve Instruction Manual

June 17, 2024
American Standard

Installation Instructions
7390.703 7390.713 7390.723 7390.733

Certified to comply with ANS A112.18.1
M96s781ev.1.1

7390.723 Bidet Faucet and Tranfer Valve

HAMPTON
Bidet Faucet and Transfer Valve with Ever Clean m pinfish & Speed Connect™ Drain
Congratulations on purchasing your American Standard faucet with Ever Clean finish and Speed Connect drain, two features found only on American  Standard faucets.

Ever Clean Finish

  • One wipe effortlessly removes spots
  • Eliminates the need for cleaners and scrubbing
  • Permanent surface protectant remains beautiful for the life of the faucet
  • Ever Clean n available on: Polished Chrome, Satin Nickel, Stainless Steel, Polished Brass (or any combination of these finishes)

Speed Connect Drain

  • Fewer parts, installs in less time
  • Never needs adjustment
  • Guaranteed to seal properly the first time, every time.

Your new American Standard faucet is designed to work only with the Speed Connect drain. Helpful tips for removing your current drain can be found in the Troubleshooting section of these instructions.
To ensure that your installation proceeds smoothly-please read these instructions carefully before you begin.

BIDET FAUCET INSTALLATION

CAUTION Turn off hot and cold water supplies before beginning.

  • Place RUBBER ING  (10)  into ESCUTCHEON  (4)

  • Install LOCKNUT  (1)  and RUBBER WASHER (2) onto VALVE BODIES  (3, 3a).  From under side of mounting surface, install VALVE BODY  (3, 3a]  through valve mounting holes. Threads of VALVE BODY  (3, 3a)  should extent at least  5/16 of a inch above mounting surface top. Fig. A. Thread ESCUTCHEON (A) onto VALVE BODIES  (3, 3a) until snug against internal stop. If necessary, adjust LOCKNUT  (1)

  • Tighten LOCKNUTS  (1)  with WRENCH ( 5 ) (supplied) to secure VALVE BODIES (3, 3a)

  • Remove ESCUTCHEON  (6),  WASHER  (7)  and UPPER GASKET  (B)  from TRANSFER VALVE  (9).  Insert TRANSFER VALVE  (9] into the center forward hole of BIDET.

  • Replace UPPER GASKET  (8)  and WASHER  (7)  and ESCUTCHEON  (6]  until it. locks against internal stop Position the side threaded outlet rearward and secure MOUNTING NUT  (11)

SPRAY INSTALLATION

  • Assemble SPRAY BODY  (1)  to BIDET. Using putty, seal underside of SPRAY BODY FLANGE  (2)  and secure with NUT  (3)
  • Thread SPRAY HOSE  (4)  with SEAL WASHER (SJ to SPRAY BODY  (1)  Connect other end of HOSE  (4]  with SEAL WASHER (6] to side outlet NIPPLE  (7)  of the TRANSFER VALVE  (8)
  • Thread SPRAY CAP  (9)  onto SPRAY BODY  (1).

POP-UP DRAIN

  • Remove CLEA PLASTIC COVER  (1)
  • Remove CARDBOARD SPACER (2 from under DRAIN POP-UP  (3).
  • Tighten TAIL PIECE  (A)  on DRAIN BODY before installing DRAIN BODY.  Fig. B.

REMOVE FLANGE

  • Thread FLANGE  (1)  counter-clockwise and remove FLANGE  (1)  and FOAM GASKET (2) from drain body.  Fig. A.
  • Thread LOCKNUT  (3)  clock-wise to bottom of drain body. Push GASKET  (4]  down against LOCKNUT  (3).   Fig. B.

INSTAU DRAIN FROM BELOW FIXTURE

  • From under side of BIDET install DRAIN BODY  (1)  up through drain outlet.
    Note:  No plumber’s putty or caulk is required. The CABLE ATTACHMENT POINT  (2]  must face towards the rear of the BIDET

  • Install FOAM GASKET  (3)  and FLANGE  (4]  onto drain body from above BIDET and tighten FLANGE  (4)  firmly

TIGHTEN LOCKNUT

  • Tighten LOCKNUT  (1)  firmly with Adjustable Wrench or Channel Locks

FLANGE GASKET

  • Check DRAIN FLANGE in BIDET to ensure that WHITE FOAM GASKET (1 is fully compressed and not visible Fig. A.
    pop-Up OD ASSEMBLY

  • Insert LIFT ROD GUIDE (1) and CABLE CONNECTOR (2J through rear hole, making sure SEAL WASHER  (3) is properly seated. Fig. B.

  • From below slip slot in MOUNTING NUT  (4)  over CABLE  (5).  Thread NUT  (4)  onto lift rod guide shank to secure ROD GUIDE  (1)  to bidet. Hand tighten only.  Fig. B.

M9S68781Rev.1.1

ATTACH CABLE CONNECTOR

  • POP-UP KNOB  (1)  must be fully down. Fig. A.
  • Thread CABLE CONNECTOR  (1)  clockwise onto DRAIN BODY CONNECTION (2) and hand tighten. Fig. B.
    Your new PO.U DAIN installation is now complete  Fig. C.
    Note:  Tailpiece on pop-up drain is 1-1/40.D.  Fig. C.

CHECK OPERATION OF POP-UP

  • Operate LIFT KNOB  (1)  to verify that STOPPER  (2) 0pens and closes.
    Note:  If 8TOPE  (2) does not open and close properly then refer to the “troubleshooting section” of these instructions
    INSTALL DIVERTER KNOB

  • Push DIVERTER KNOB  (1) onto HANDLE ADAPTER 121

  • Push on ING (3)  and tighten with SCREW  (4.)

  • Press on KNOB CAP  (5)
    Note:  Screwdriver gap is for disassembling and should point downwards

TEE AND HOSE CONNECTION

  • Insert SEAL  (1)  into ADAPTER  (2)  and tighten ADAPTER  (2)  to side of TRANSFER VALVE  (3)
  • lnstall SEAL  (4)  into coupling nut of TEE  (5)  and tighten connection to ADAPTER  (2.)
  • Connect HOSE COUPLING NUTS  (6)  to Hot and Cold valve bodies and securely tighten.

WATER SUPPLY CONNECTION
NOTE: FLEXIBLE SUPPLIES OR BULL-NOSE RISERS NOT INCLUDED AND MUST BE PURCHASED SEPARATELY.

  • Connect water supply to VALVE BODIES  (7, 7a)  with /2 IPS FLEXIBLE SUPPLIES  (8)  0r 3/8 0.D. BULL-NOSE RISES  (9). Use adjustable wrench to tighten connections. Do not over tighten. Be careful not to kink copper supply  when bending. Use tubing cutter to cut to proper length.
  • Connect HOT water supply to inlet of left SHANK and COLD water supply to right SHANK using sealant, appropriate connectors and COUPLING NUTS
  • Connect 1-1/4″ 0.D. tailpiece on POP-UP DRAIN to waste outlet

INSTALL HANDLES (Lever]

  • Turn VALVE into OFF position

  • Push ADAPTER  (1)  into HANDLE BASE  (2)  in a @gy,that the pale square on the ADAPTER  (1)  fits n the temple sager of the HANDLE BASE  (2)

  • Push HANDLE BASE  (2)  and ADAPTER  (1)  onto VALVE STEM  (5)

  • Check alignment, if not satisfactory aligned;

    • push Out ADAPTER (1) carefully
    • Turn ADAPTER (1) either 45 or 90′ so that male square on ADAPTER (1] catches different female square in HANDLE BASE (2)
  • Secure HANDLE BASE (2) with HANDLE SCREW (3

  • Push INDEX CAP (A) in hole of LEVE BALL (6)

INSTALL HANDLES (Cross]

  • Turn VALVE into OFF position.
  • Push ADAPTER (1) into HANDLE  BASE (2) in ,a way that the mole square on the )ATER (1) fits in the female  square of the HANDLE BASE 2)
  • Push HANDLE BASE (2) and ADAPTER (1) onto VALVE STEM (5)
  • Check alignment, if not satisfactory aligned;
    • Push out ADAPTER (1) carefully.
    • Turn ADAPTER (1) either 45′ or 90° so that male square on ADAPTER (1) catches different female square in HANDLE BASE (2).
  • Secure HANDLE BASE (2) and METAL CROSS (6) or PORCELAIN CROSS (7) with HANDLE SCREW (3).
  • Push INDEX CAP (4) in hole of METAL CROSS (6) or PORCELAIN CROSS (7).

TEST INSTALLED FITTING

  • With HANDLES (1) in OFF position, turn on WATER SUPPLIES (2) and check all connections for leaks.
  • Operate both HANDLES (1) to flush water lines thoroughly.
  • Rotate TRANSFER VALVE (5) from rim wash to spray several times to check operation.

CHECK DRAIN CONNECTIONS

  • Pull up POP-UP KNOB (3) and fill Bidet with water. Check that DRAIN STOPPER (4) makes a good seal and retains water in Bidet. If STOPPER (4) does not seal properly, please refer to “Troubleshooting Guide” in these instructions.
  • Push POP-UP KNOB (3) down and check all drain connections and “P” trap for leaks. * Tighten if necessary.

Ever Clean me finish Care Instructions

American Standard’s Ever Clean finish will wipe clean with a soft, dry cloth,
A soft cloth with clean water may also be used, if desired. No additional cleaning products are required.
DO NOT USE: Soaps, acid, polish, abrasives, harsh cleaners, or a cloth with a coarse surface.

Speed Connect™ Drain Troubleshooting Guide **

**

If sink does not hold water even though Stopper is in the “down” position:
• Follow CABLE ADJUSTMENT PROCEDURE
If Stopper does not raise up fully or sink drains too slowly
• Follow CABLE ADJUSTMENT PROCEDURE
lf you need to remove the Stopper:
• Follow STOPPER REMOVAL PROCEDURE
lf you would like the ability to remove your Stopper simply by lifting it out of the drain:
• Follow STOPPER INSTALLATION PROCEDURE for “Unlocked” mode

CABLE ADJUSTMENT PROCEDURE

  • Disconnect the Cable from the Drain by threading the Cable Connector (1] counter-clockwise. Fig. A.
  • Look at the area on the Drain Body where the Cable was attached and locate the component labeled as Cam” in the illustration. Fig. B.
  • Use a small screwdriver to rotate the Cam in the clockwise direction as far as it will go. At this point the Stopper should be in the UP position. Fig. B, C.
  • Push DOWN on the Lift-Knob to make sure it is fully down. Fig. C.
  • Re-attach the Cable to the Drain Body Connection (2] by threading the Cable Connector (1) clockwise onto the Drain Body Connection (2) and hand-tighten. Fig. A.

STOPPER REMOVAL PROCEDURE

  • Disconnect the Cable from the Drain by threading the Cable Connector (1) counter-clockwise. Fig. A.

  • Look at the area on the Drain Body where the Cable was attached and locate the component labeled as Cam” and Cam Cap” in the illustration.  Fig. B.

  • Use fingers or small screwdriver under either side of the Cam Cap to pry it out from the Drain.  Fig. D.

  • Remove the Cam by pulling it straight out while wiggling gently to loosen the Rubber Seal.  Fig. E.

  • The Stopper can now be removed by lifting it out of the Drain.  Fig. F.

STOPPER INSTALLATION PROCEDURE

The Stopper can be installed two ways, “Locked” Mode (Stopper cannot be removed) or “Unlock” Mode (Stopper is removable).
Locked Mode:

  • Look at the Plastic Loop at the bottom of the Stopper and notice that the Loop is on one side of the Stopper.  Fig. G.
  • To install the stopper in “Lacked” mode, insert the Stopper into the Drain so that the Plastic Loop is facing toward the rear of the Sink and the American Standard logo is facing front. Rotate Stopper slightly if necessary so that the  Stopper slides all the way down.  Fig. G.
  • Re-install the Cam into the Drain, rotating the Cam if necessary to make sure it is fully inserted.  Fig. J.
  • Re-install the Cam Cap, making sure the guide teeth are facing outward. If the Cam Cap does not “snap” into place, then rotate the Cam to make sure it is fully inserted. Fig. K.
  • Re-attach Cable. See “CABLE ADJUSTMENT PROCEDURE” in Troubling Shooting Guide to complete installation. Stopper will be in “Lacked” mode and not be removable.

Unlocked Mode:

  • Look at the Plastic Loop at the bottom of the Stopper and notice that the Loop is on one side of the Stopper. Fig. H.
  • To install the stopper in “Unlocked” mode, insert the Stopper into the Drain so that the Plastic Loop is facing toward the front of the Sink and the American Standard logo is facing rear. Rotate Stopper slightly if necessary so that the  Stopper slides all the way down.  Fig. H.
  • Re-install the Cam into the Drain, rotating the Cam if necessary to make sure it is fully inserted.  Fig. J.
  • Re-install the Cam Cap, making sure the guide teeth are facing outward. If the Cam Cap does not “snap” into place, then rotate the Cam to make sure it is fully inserted. Fig. K.
  • Re-attach Cable. See “CABLE ADJUSTMENT PROCEDURE” in “Troubling hooting Guide” to complete installation. Stopper will be in “Unlocked” mode and removable.

M968781 Rev.1.1
https://manual-hub.com/

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

American Standard User Manuals

Related Manuals