American Standard 7755.1xx NextGen Selectronic Integrated Faucet
CAUTION: Use only American Standard supplied transformers and cable sets. Using non-AS supplied cables, or cutting, splicing or modifying any components will void the warranty.
Product No’.s & Options
NOTE TO INSTALLER: Please give this manual to the customer after installation.
To learn more about American Standard Selectronic® Products visit our website
at: www.americanstandard-us.com or
e-mail us at: sensor@lixil.com For Parts, Service,
Warranty or other Assistance, please call (844) CRT-TEAM /
844-278-8326 (In Canada:
1-800-387-0369)
Thank you for selecting American-Standard…the benchmark of fine quality for
over 100 years. To ensure that your installation proceeds smoothly–please read
these instructions carefully before you begin.
UNPACKING
All American Standard Products Are Water Tested At Our Factory. Some Residual Water May Remain In The Valve During Shipping. Remove the fitting and loose items from the carton. The illustration below shows all the fittings and loose items after they have been removed from the carton. Some items may be packaged partially assembled to other items.
- Installation Instructions
- Spout Assembly (less mixing) 2a. Spout Assembly (mixing)
- Mounting Kit
- 4″ and 8″ Deck plate (optional, must be ordered separately)
- Inline Filter/Check Valve Assembly
- Assembly Parts
POWER KITS SOLD SEPARATELY
Roughing-in Dimensions
Note: All plumbing and electrical wiring must be installed in accordance
with applicable codes, regulations and stan-dards.
CAUTION: Use only American Standard supplied transformers and cable sets.
Using non-AS supplied cables, or cutting, splicing or modifying any components
will void the warranty.
**RECOMMENDED TOOLS
**
- 2.5 mm Hex Wrench (Included)
- Adjustable Wrench
- Plumbers’ Putty or Caulking
- Flat Blade Screwdriver
- Tape Measure
- 2.0 mm Hex Wrench (Included)
SPOUT ASSEMBLY INSTALLATION; Fig. 1
CAUTION Turn ofsupplies beforf hot and cold water e beginning
-
Make sure O-RING (1) is installed in spout base.
IMPORTANT: Do not use putty when installing faucet without escutcheon. -
If installing DECK PLATE (2) (optional): Apply a bead of putty to bottom edge of PUTTY PLATE (2). Install SCREW (11) into the MOUNTING BASE OF THE FAUCET (13) and allign SCREW (11) with HOLE (12).
-
Insert SUPPLY HOSES (3), SHANK (4) and SENSOR CABLE (5) (only included in base model) through hole in DECK PLATE with PUTTY PLATE (2) and mounting surface.
-
Assemble RUBBER WASHER (7), BRASS WASHER (8) and THREADED LOCKNUT (9) onto SHANK (4) from underside of sink or mounting surface. Hand tighten LOCKNUT (9).
-
Use a screwdriver to tighten SCREWS (10) on LOCKNUT (9). Work your way around LOCKNUT (9), tightening the screws slightly each time until all are snug to ensure even pressure.
ELECTRICAL INSTALLATION
Product | Page |
---|---|
PWRX Power Kit (PK00.WRK) | **** |
4
Plug-In AC Power Kit (PK00.PAC)| 5
Hard-Wired AC Power Kit (PK00.HAC)| 5
Multi-AC Power Kit (PK00.MAC)| 5
Important: All 7755 faucets with CR-P2 battery come with electrical connections preaseambled at the factory. No further action necessary.
PWRX 10 YEAR BATTERY SYSTEM; Fig. 1
PWRK™ VERSION;
- Connect PWRX BATTERY PACK (1) to SENSOR CABLE (2).
- Secure the connections by installing into CONNECTOR LOCKING DEVICE (3) as shown. Rotate the END CAPS (4) to secure the connection within the CONNECTOR LOCKING DEVICE (3).
- Determine the mounting location of the PWRX BATTERY PACK (1) by marking center lines as shown.
- Place the BRACKET (5) on the horizontal center line and mark the location of the mounting holes to be drilled.
- Using 1/4″ diameter drill bit, drill two mounting holes aproximately 1″ deep.
- Install the two ANCHORS (6) provided into the mounting holes.
- Place the BRACKET (5) over the ANCHORS (6) and secure with the SCREWS (7) provided. Do not overtighten.
- Insert PWRX BATTERY PACK (1) into BRACKET (5).
AC VERSIONS (HARD-WIRED / PLUG-IN POWER SUPPLY); Fig. 2
Important: Turn off power to outlet or electrical box. FOR PLUG-IN VERSION;
- Connect PLUG-IN AC POWER SUPPLY (2) to one end of the SINGLE AC ADAPTER (6).
- Connect SENSOR CABLE (4) to the other end of the SINGLE AC ADAPTER (6).
- Connect PLUG-IN AC POWER SUPPLY (2) to wall outlet.
FOR HARD-WIRED VERSION;
- Connect HARD-WIRED AC TRANSFORMER (3) to AC-DC CONVERTER (7).
- Connect 10’ EXTENSION CABLE (1) to AC-DC CONVERTER (7).
- Connect SENSOR CABLE (4) to the other end of the 10′ EXTENSION CABLE (1).
- Make Black and White power line connections to HARD-WIRED AC TRANSFORMER (3) and mount on ELECTRICAL BOX (5).
CAUTION: Use only American Standard supplied transformers and cable sets. Using non-AS supplied cables, or cutting, splicing or modifying any components will void the warranty.
MULTI-AC VERSION (DAISY-CHAIN); Fig. 3
Important: Disconnect the first unit’s Multi-AC Adapter from power supply
before making daisy-chain connections.
Note: For Unit #1 electrical instructions, refer to Figure 2 (above). For
subsequent Units, refer to instructions below…
- Connect one end of the 10′ EXTENSION (1) to the available terminal of the previous unit’s MULTI-AC ADAPTER (2), and the other end to the single terminal of the current unit’s MULTI-AC ADAPTER (3).
- Connect SENSOR CABLE (4) to either of the two available terminals of MULTI-AC ADAPTER (3).
- Repeat Steps above for each additional Unit, for a Max. of 15 Units on one AC POWER SUPPLY.
MAKE WATER SUPPLY CONNECTIONS; Fig. 4
- Turn off hot and cold water supplies before beginning.
- Install INLINE FILTER (3) on each wall supply outlet. Be sure that INLINE FILTER (3) is inserted in the correct direction. (See Illustration)
- Connect HOT FLEXIBLE SUPPLY (marked with red stripe) (1) to INLINE FILTER (3) on hot water control stop (4). Connect COLD FLEXIBLE SUPPLY (marked with blue stripe) (2) to INLINE FILTER on cold water control stop (5). Use adjustable wrench to tighten connections. Do not over tighten.
- Faucet supplies are 24″ long from faucet base.
Note; If additional supply length is required, installer must purchase those parts separately.
Important; If SUPPLY HOSES (1, 2) are too long, loop as illustrated to avoid kinking.
REMOVE MIXING HANDLE
FOR FAUCETS PURCHASED AFTER OCTOBER 2019 (FIG. 6)
Note: Before removing the handle, preset the desired water temperature
and while disassembling make sure to keep the SHAFT EXTENSION (8) in place.
-
Unthread SET SCREW (3) and remove HANDLE (5).
-
Remove LIMIT STOP (1).
-
Using a Slotted screwdriver unthread SCREW (7) and remove SHAFT EXTENSION (8).
Note: Hold the extension in place while unthreading the screw. -
Install CAP (9) onto the Body and press until you hear a click.
Note: Sharper side faces towards the back of the body.
HAND WASH SENSOR OPERATION; Fig. 1
REMOVE PROTECTIVE FILM FROM SENSOR EYE WHEN INSTALLATION IS COMPLETE.
When the Sensor detects a user, the water immediately starts to flow. Water
flow will stop 1.5 seconds after user is out of sensor range. This Comfort
delay allows the user to comfortably move their hands without the water
turning off. As a precaution, a Safety Timer will turn off the water, after
the sensor has been blocked for 59 seconds. The water will stay off until the
blockage is removed from the detection zone. The Comfort and Safety time
settings can be adjusted using the Optional Remote Control (605XRCT).
MAINTENANCE
B REPLACE BATTERY; Fig. 5, 6
- Remove COVER SCREW (1) and lift COVER (15) off.
- Disconnect SENSOR CABLES (6) and (7) from the BATTERY and SOLENOID VALVE. (Fig. 6)
- Push BATTERY (17) forward and Pull it out. (Fig. 5)
- Replace the new battery with the same placement.(Insert terminal side first)
CHANGE SENSOR RANGE; Fig. 5, 6
- Remove the COVER SCREW (1).
- Remove the COVER (15).
- Disconnect the BLACK POWER SUPPLY CONNECTOR (7) and reconnect. Fig. 6.
- While the SENSOR CONTROL LED (9) is blinking slowly, place your hand 1 – 2 in. (25.4-50.8mm) in front of the sensor.
- When the LED stops blinking and stays “ON”, move your hand to the desired position and hold in place until the LED begins to blink again.
- Once the SENSOR CONTROL LED (9) begins to blink again, remove your hand from the detection zone. When the flashing stops, the detection distance is set.
- Reassemble the COVER (15) and secure it with COVER SCREW (1).
D ADJUST HOT LIMIT STOP; Fig. 7, 9
To reduce the amount of hot water that can mix with cold, the installer can adjust hot limit stop (Four different settings).
- Rotate LEVER HANDLE (3) counter-clockwise to its stop position (100% cold).
- Remove LEVER SCREW (5) and pull off the LEVER HANDLE (3).
- Pull out LIMIT STOP (1) from the VALVE STEM (5).
- Rotate LIMIT STOP (1) between the shaded area and insert back onto VALVE STEM (5).
- Each notch on the LIMIT STOP (1) will reduce the amount of hot water by approximately 3%. For example, the 2nd notch will have 97% of maximum temp, the 3rd notch will have 94% and the fourth will be 91%.
- Replace LEVER HANDLE (3), LEVER HANDLE SCREW (5) and tighten.
ADJUST OR REPLACE MAXIMUM OUTLET TEMPERATURE; Fig. 8
- With the COVER off, the installer can reduce the maximum mixed water temperature by turning the THERMO VALVE (4) clockwise with a screwdriver.
- Remove SCREW (6) and unthread THERMO VALVE (4). Replace with new THERMO VALVE (4).
WARNING
- Do not turn the THERMO VALVE (4) More than 1 turn.
- The maximum mixed water temperature can not be increased due to ASSE 1070 requirements.
F GENERAL CLEANING
- Only use a damp, soft cloth to clean the spout and the sensor.
- For tougher dirt, use a soft cloth with diluted dish washing detergent. Wipe the area using a wet cloth and dry using a soft cloth.
CAUTION Do not scratch the sensor when cleaning. Avoid using any abrasives or harsh detergents or chemicals.
TROUBLESHOOTING FLOW CHARTS
UNIT DOES NOT FUNCTION
HOT LINE FOR HELP
For toll-free information and answers to your questions, call: (844) CRT-TEAM
/ 844-278-8326
Mon. – Fri. 8:00 a.m. to 8:00 p.m. EST Saturday 10:00 a.m. to 4:00 p.m. EST IN
MEXICO 01-800-839-1200
IN CANADA 1-800-387-0369 (TORONTO
1-905-306-1093)
Weekdays 8:00 a.m. to 7:00 p.m. EST
Product names listed herein are trademarks of AS America, Inc. ©2018
To learn more about American Standard Selectronic® Products visit our website
at: www.americanstandard-us.com or
e-mail us at: CRTTEAM@lixilamericas.com
NextGen Selectronic®
Integrated Faucet with Optional Above-Deck Mixing & SmarTherm® Temperature
Limiter
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>