OUT LED on receiv e r (RX)
The yellow LED ON indicates the presenc e of the object into controlled area.
POWER ON LED on receiv er (RX)
The green LED ON indicates t he optimal dev ice functioning.
The fast blinking of the green LED i ndicates a critical dev ice alignment.
Please refer to “DIAGNOSTICS” paragraph for other indications.
POWER ON LED on emi tter (TX)
The green LED ON indicates t he correct dev ice functioning.
Please refer to “DIAGNOSTICS” paragraph for other indications.
INSTALLATION MODES
General in formation on device positioning
-
Align the two receiver (RX ) and emitter (TX ) units, verify ing that their distance is inside the dev ice operating dist ance, in a parallel manner, plac ing the sensitiv e sides one in front of the other, w i th the connectors oriented on the same side. The critical alignment of the unit w ill be signalled by the fast blinking of the green receiv er LED.
-
Mount the receiver and emitter units on rigid supports which are not subject to strong vibrations, using specific fixing brackets and /or the holes present on the device lids.
Precautions to respect when choosing and installing the device -
Choose the device according to the minimum object to detect and the maximum controlled area requested (= operating distance x controlled height);
-
In agroindustrial applications, the compatibility of light grid housing material and any chemical agents used in the production process has to be verified with the assistance of the DATALOGIC technical sales support department;
-
The AREAscanTM light grids are NOT safety devices, and so MUST NOT be used in the safety control of the machines where installed.
Moreover the following points have to be considered:
– avoid installation near very intense and / or blinking light sources, in
particular near to the receiver unit;
– the presence of strong electromagnetic disturbances can condition the
correct functioning of the device; this condition has to be carefully
evaluated and checked with the DATALOGIC technical sales support department;
– the presence of smoke, fog and suspended dust in the working environment can
reduce the operating distance of the device;
– strong and frequent temperature variations, with very low peak temperatures,
can generate a thin condensation layer on the optics surfaces, compromising
the correct functioning of the device;
– reflecting surfaces near the luminous beam of the AREAscanTM device (above,
under or lateral) can cause passive reflections able to compromise object
detection inside the controlled area.
If different devices have to be installed in adjacent areas, the emitter of
one unit must not interfere with the receiver of the other unit.
General information relative to object detection and measurement
For a correct object detection and / or measurement, the object has to pass
completely through the controlled area; testing the correct detection before
beginning the process is suggested.
CONNECTIONS
- Shielded cables are not foreseen in the standard connection
- Ground connection of the two units is not necessary
- Use the same power supply for both units: for a correct functioning it’s necessary that both units TX and RX have the same voltage reference 0V
FUNCTIONING AND PERFORMANCES
The beam
interruption due to the passage of an object inside the controlled area caused
the closing of the switching output and the variation of the device analogue
output signal.
Small objects can be detected (reaching dimensions of only 5 mm) and determine
linear measurements with a 3 mm error in best cases.
In particular, the switching output is always activated when at least one beam
is obscured. The status variation is signalled by the yellow receiver LED that
turns on.
The analogue output value (0-10 V) is proportional to the number of obscured
beams (0V means that no beam is interrupted, 10V all beams interrupted)
The device does not require calibration; periodical checks of the resolution
and / or measurement are however suggested.
The blinking of the green receiver LED (stability function) signals the
critical alignment of the units and / or the functioning outside or near the
maximum operating distance. In optimal conditions the LED remains on
continuously.
The two units are synchronised via cable (SYNC wire); precarious connections
or induced disturbances on the synchronism line can cause device
malfunctioning or a temporary blocking.
The diagrams, given below, show the typical minimum resolution trend of each
model, SR (standard resolution) and HR (high resolution), in according to the
operating distance (D).
For DS1-LD-SR-XXX-PV, the minimum resolution at a particular operating
distance is to be intended with the trimmer calibrated near commutation
threshold for that distance.
EMISSION POWER REGULATION (only DS1-LD-SR-XXX-PV)
The emitter is equiped with a trimmer which let user change the emission
power. The operating distance increases rotating the trimmer clockwise.
The emission power reduction it is useful to decrease passive reflections when
the maximum operating distance it is not required. Trimmer rotation is limited
to 260°. Do not apply a torque greater than 35 Nmm.
Rotate the trimmer clockwise to the limit (maximum emission), then align RX
and TX at the required operating distance (LED OUT off); decrease emission
power rotating the trimmer counterclockwise until the output switches (LED OUT
off) or the limit is reached (minimum emission); in the first case, rotate the
trimmer clockwise until the output switches again and LED OUT remains off.
TECHNICAL DATA
Power supply: | 24 Vdc ± 15% |
---|---|
Consumption on emitting unit (TX): | 150 mA max. |
Consumption on receiving unit (RX): | 50 mA max without load |
Switching output: | 1 PNP output |
Switching output current: | 100 mA; short-circuit protection |
Output saturation voltage: | ≤ 1.5 V at T=25 °C |
Analogue output: | 0-10V proportional to obscured beams |
Analogue output current: | 10 mA max. (1KW minimum resistive load) |
Minimum resolution: | refer to “Specifications” table |
Measurement precision: | ± 3.5 mm (refer to “Specifications” table) |
Response time: | 1 ms (refer to “Specifications” table) |
Indicators: | RX: OUT LED (yellow) / POWER ON LED (green) |
TX: POWER ON LED (green)
Operating temperature:| 0…+ 50 °C
Storage temperature:| -25…+ 70 °C
Operating distance (typical values):| DS1-SD-XX-XXX-JV : 0.15…0.8 m DS1
-LD-XX-XXX-JV : 0.15…2.1 m DS1-LD-SR-XXX-PV : 0.20…2.5 m DS1-HD-XX-
XXX-JV : 0.20…4.0 m
Emission type:| Infrared (880 nm)
Vibrations:| 0.5 mm amplitude, 10 … 55 Hz frequency, for every axis
(EN60068-2-6)
Shock resistance:| 11 ms (30 G) 6 shock for every axis (EN60068-2- 27)
Housing material:| Black electro-painted aluminium
Lens material:| PMMA
Mechanical protection:| IP65 (EN 60529)
Connections:| M12 4-pole connector for TX M12 5-pole connector for RX
Weight:| 300 g. (DS1-xx-010-xx)
400 g. (DS1-xx-015-xx)
600 g. (DS1-xx-030-xx)
DIAGNOSTICS
RECEIVING UNIT (RX):
Segnal | Status | Cause | Action |
---|---|---|---|
ON | Switching output. | ||
Presence of the object in the controlled area. | |||
OFF | Switching output. | ||
Controlled area free of objects. | |||
ON | Optimal functioning | ||
Fast blinking | Critical alignment of the unit or/and functioning | ||
closed to maximum operating distance. | |||
Slow blinking | Wrong connections and/or malfunctioning. | – Verify the output |
connections and any short- circuits
– Switch OFF and switch ON the device.
– If condition persists, contact Datalogic.
OFF| Device is not powered.| – Verify the connections.
– If condition persists, contact Datalogic.
EMITTING UNIT (TX):
Segnal | Status | Cause | Action |
---|---|---|---|
ON | Normal functioning of emission unit. | ||
Blinking | Unit malfunctioning | – Switch OFF and switch ON the device. |
– If condition persists, contact Datalogic.
OFF| Absence of powering and/or synchronism with receiver| – Verify the
connections and right value of power supply.
– If condition persists, contact Datalogic.
DIMENSIONS
FIXING BRACKET The fixing bracket is supplied with the product.
SPECIFICATIONS
Model| Controlled height (mm)| N°. Beams| Minimum
resolution (mm)| Output analogue
sensitivity (V)| Measurement precision (mm)| Response time
(ms)| Operatine distance (m)
---|---|---|---|---|---|---|---
DS1-LD-HR-010-JV| 100| 32| 5| 0.31| ± 3.5| 2| 0.15…2.1
DS1-LD-HR-015-JV| 150| 48| 5| 0.21| ± 3.5| 2.75| 0.15…2.1
DS1-LD-HR-015-JV| 100| 16| 7| 0.63| ±7| 1| 0.15…2.1
DS1-LD-SR-010-PV| 100| 16| 7| 0.63| ±7| 1| 0.20…2.5
DS1-LD-SR-015-JV| 150| 24| 7| 0.42| ±7| 1.5| 0.15…2.1
DS1-LD-SR-015-PV| 150| 24| 7| 0.42| ±7| 1.5| 0.20…2.5
DS1-LD-SR-030-JV| 300| 48| 7| 0.21| ±7| 2.75| 0.15…2.1
DS1-LD-SR-030-PV| 300| 48| 7| 0.21| ±7| 2.75| 0.20…2.5
DS1-SD-SR-010-JV| 100| 16| 7| 0.63| ±7| 1| 0.15…0.8
DS1-SD-SR-015-JV| 150| 24| 7| 0.42| ±6| 1.5| 0.15…0.8
DS1-SD-SR-030-JV| 300| 48| 7| 0.21| ±7| 2.75| 0.15…0.8
DS1-SD-HR-010-JV| 100| 32| 4| 0.31| ±3| 2| 0.15…0.8
DS1-SD-HR-015-JV| 150| 48| 4| 0.21| ±3| 2.75| 0.15…0.8
DS1-HD-SR-010-JV| 100| 16| 7| 0.63| ±7| 1| 0.20…4
DS1-HD-SR-015-JV| 150| 24| 7| 0.42| ±7| 1.5| 0.20…4
DS1-HD-SR-030-JV| 300| 48| 7| 0.21| ±7| 2.75| 0.20…4
Datalogic S.r.l.
Via S. Vitalino 13 – 40012 Calderara di Reno – Italy
Tel: +39 051 3147011 – Fax: +39 051 3147205 –
www.datalogic.com
Helpful links at www.datalogic.com: Contact Us,
Terms and Conditions, Support.
The warranty period for this product is 36 months. See General Terms and
Conditions of Sales for further details.
**** Under current Italian and European laws, Datalogic is not obliged to
take care of product disposal at the end of its life. Datalogic recommends
disposing of the product in compliance with local laws or contacting
authorised waste collection centres.
© 2009 – 2017 Datalogic S.p.A. and/or its affiliates • ALL RIGHTS RESERVED. •
Without limiting the rights under copyright, no part of this documentation may
be reproduced, stored in or introduced into a retrieval system, or transmitted
in any form or by any means, or for any purpose, without the express written
permission of Datalogic S.p.A. and/or its affiliates. Datalogic and the
Datalogic logo are registered trademarks of Datalogic S.p.A. in many
countries, including the U.S.A. and the E.U. All other trademarks and brands
are property of their respective owners. Datalogic reserves the right to make
modifications and improvements without prior notification.
826003144 Rev . E
References
- Datalogic | Automatic Data Capture and Industrial Automation - Datalogic
- Manual-Hub.com – Free PDF manuals!
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>