American Standard PLA-A18EA8 Advanced Clean AC 3.0 SpaLet Bidet Seat Instruction Manual
- June 17, 2024
- American Standard
Table of Contents
- American Standard PLA-A18EA8 Advanced Clean AC 3.0 SpaLet Bidet Seat
- Product Information
- Product Usage Instructions
- FAQ
- SPECIFICATIONS
- INDOOR UNIT ACCESSORIES
- OUTDOOR UNIT ACCESSORIES
- INDOOR UNIT DIMENSIONS
- OUTDOOR UNIT DIMENSIONS
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
American Standard PLA-A18EA8 Advanced Clean AC 3.0 SpaLet Bidet Seat
Product Information
Specifications
- Model: PLA-A18EA8 & PUZ-A18NKA7
- BTU/H: 18,000
- Ceiling Cassette Size: 3′ x 3′
- Heat Pump Universal Outdoor
Indoor Unit
The indoor unit has the following specifications:
- Operating Temperature Range: test
- BTU/H: 18,000
- W: 18,000
- Pints/h: 8,000
- Indoor Unit Dimensions (W x D x H): In. [mm]
- Width: 33-1/16 [840]
- Depth: 33-1/16 [840]
- Height: 10-3/16 [258]
- Weight: Lbs. [kg]
- Lbs.: 46 [21]
- Kg: 77 [34.8]
Outdoor Unit
The outdoor unit has the following specifications:
-
Operating Temperature Range: test
-
Refrigerant Piping Size: A A A W CFM
-
Outdoor Unit Dimensions (W x D x H): In. [mm]
-
Width: 31-13/16 x 11-13/16 x 24-13/16 [809 (+62) x 300 x
630] -
Depth: 37-1/16 x 16-3/16 x 27-7/16 [941 x 411 x 697]
-
Height: 100 [45]
-
-
Weight: Lbs. [kg]
- Lbs.: 112 [51]
- Kg: 115
Indoor Unit Accessories: PLA-A18EA8
- Control Interface: Remote Sensor Wired Remote Controller (PAC-SF40RM-E)
Outdoor Unit Accessories: PUZ-A18NKA7
- PAC-SJ07SG-E
- PAC-SG63DP-E
- PAC-SG64DP-E
- PAC-SK52ST
- M21EC0397
- M21EC1397
- MAC-871DS
- HG-A5
- PAC-SJ96MA-E
- S144-250
- S144-50
- S164-250
- S164-50
- ULTRILITE1
- QSMS1801M
- QSMS2401M
- QSWB2000M-1
- QSWBSS
- QSMS1201M
- WB-PA4
- WB-RE4
- WB-SD4
Product Usage Instructions
Installation
Follow these steps to install the product:
- Choose a suitable location for the indoor unit.
- Mount the indoor unit on the ceiling using the provided accessories.
- Connect the refrigerant piping between the indoor and outdoor units.
- Install the outdoor unit in a well-ventilated area.
- Connect the electrical wires according to the provided diagram.
- Test the system to ensure proper installation.
Operation
To operate the product, follow these steps:
- Turn on the power supply.
- Select the desired mode (cooling, heating, etc.) using the remote control or wired controller.
- Adjust the temperature and fan speed as desired.
- The product will automatically maintain the set temperature and provide comfortable air conditioning.
FAQ
Q: Can I use a wireless remote controller with the PLA-A18EA8 indoor unit?
A: No, the PAC-SF40RM-E wired remote controller is not compatible with
wireless remote controllers.
Q: What is the recommended ceiling height for the indoor unit?
A: The minimum recommended ceiling height is 118-1/8″ (3000mm) or more.
Q: Can I install the outdoor unit in a small space?
A: No, there should be at least 17-11/16″ (450mm) of space in the ceiling
for proper installation.
INDOOR UNIT FEATURES
- Space-efficient ductless installation
- Equipped with 3D i-see Sensor® for enhanced comfort and energy efficiency
- Airflow settings for high and low ceiling applications
- Individual vane settings for direct/indirect airflow control or variable airflow patterns
- Knockouts for outside-air intake and branch-duct run
- Filter indicator signal
- Easy-to-clean, washable filter (optional high-efficiency filter available – requires multi-function casement)
- Built-in condensate lift mechanism
- Ideal for retail shops, classrooms, office spaces, conference centers, building lobbies, and more
- Multiple control options available:
- kumo cloud® smart device app for remote access
- Third-party interface options
- Wired or wireless controllers
OUTDOOR UNIT FEATURES
- Variable speed INVERTER-driven compressor
- Pre-charged with refrigerant volume for piping length up to 70 ft
- Low ambient cooling down to 0°F providing 100% capacity
- 24-hour continuous operation (cooling mode)
- High pressure protection
- Fast restart
- Superior energy and operational efficiency
- Seacoast protection*
- External Outer Panel: Phosphate coating + Acrylic-Enamel coating
- Fan Motor Support: Epoxy resin coating (at edge face)
- Separator Assembly Valve Bed: Epoxy resin coating (at edge face)
- Blue Fin treatment is an anti-corrosion treatment that is applied to the Heat exchanger coil to protect it against airborne contaminants.
- Heat exchanger coil and base panel rated for 2,000 hours in accordance with ASTM B117 testing
*Seacoast protection standard from 2022 production
SPECIFICATIONS
PLA-A18EA8 & PUZ-A18NKA7
Cooling at 95°F1
| Maximum Capacity| BTU/H| 18,000
---|---|---|---
Rated Capacity| BTU/H| 18,000
Minimum Capacity| BTU/H| 8,000
Maximum Power Input| W| 1,250
Rated Power Input| W| 1,250
Moisture Removal| Pints/h| 2.4
Sensible Heat Factor| 0.85
Power Factor [208V / 230V]| %| 95.3 / 95.3
Heating at 47°F2
| Maximum Capacity| BTU/H| 23,000
Rated Capacity| BTU/H| 19,000
Minimum Capacity| BTU/H| 7,900
Maximum Power Input| W| 1,700
Rated Power Input| W| 1,300
Power Factor [208V / 230V]| %| 95.8 / 95.8
Heating at 17°F3
| Maximum Capacity| BTU/H| 13,500
Rated Capacity| BTU/H| 11,000
Maximum Power Input| W| 1,390
Rated Power Input| W| 1,300
Efficiency
| SEER2| 25.0
EER21| 14.4
HSPF2 [IV]| 9.2
COP at 47°F2| 4.28
COP at 17°F at Maximum Capacity3| 2.85
ENERGY STAR® Certified| Yes
Electrical
| Voltage, Phase, Frequency| 208/230, 1, 60
Guaranteed Voltage Range| V AC| 198 – 253
Voltage: Indoor – Outdoor, S1-S2| V AC| 208/230
Voltage: Indoor – Outdoor, S2-S3| V DC| 24
Short-circuit Current Rating [SCCR]| kA| 5
Recommended Fuse/Breaker Size (Oudoor)| A| 15
Recommended Wire Size [Indoor – Outdoor]| AWG| 14
Power Supply| Indoor unit is powered by the outdoor unit
Indoor Unit
| MCA| A| 1.0
Fan Motor Full Load Amperage| A| 0.28
Fan Motor Type| DC Motor
Airflow Rate at Cooling, Dry| CFM| 460–490–570–600
Airflow Rate at Cooling, Wet| CFM| 380–420–530–560
Airflow Rate at Heating, Dry| CFM| 420–460–570–600
Sound Pressure Level [Cooling]| dB[A]| 28–29–31–32
Sound Pressure Level [Heating]| dB[A]| 28–29–31–32
Drain Pipe Size| In. [mm]| 1-1/4 [32]
Condensate Lift Mechanism, Maximum Distance| In. [mm]| 33-7/16 [850]
Coating on Heat Exchanger| —
External Finish Color| White Munsell 6.4Y 8.9/0.4
Unit Dimensions| W x D x H: In. [mm]| 33-1/16 x 33-1/16 x 10-3/16 [840 x 840 x
258]
Package Dimensions| W x D x H: In. [mm]| 34-19/64 x 35-35/64 x 15 [871 x 903 x
381]
Unit Weight| Lbs. [kg]| 46 [21]
Package Weight| Lbs. [kg]| 77 [34.8]
Indoor Unit Operating Temperature Range| Cooling Intake Air Temp [Maximum /
Minimum]*| °F| 90 DB, 72 WB / 66 DB, 61 WB
Heating Intake Air Temp [Maximum / Minimum]| °F| 77 DB / 59 DB
NOTES
- AHRI Rated Conditions
- 1Cooling (Indoor // Outdoor)
- °F 80 DB, 67 WB // 95 DB, 75 WB
- (Rated data is determined at a fixed compressor speed)
- 2Heating at 47
- °F (Indoor // Outdoor)
- °F 70 DB, 60 WB // 47 DB, 43 WB 3Heating at 17
- °F (Indoor // Outdoor)
- °F 70 DB, 60 WB // 17 DB, 15 WB
- Conditions
- 4Heating at 5
- °F (Indoor // Outdoor)
- °F 70 DB, 60 WB // 5 DB, 4 WB
*Indoor/Outdoor Unit Operating Temperature Range (Cooling Air Temp [Maximum / Minimum]):
- Applications should be restricted to comfort cooling only; equipment cooling applications are not recommended for low ambient temperature conditions.
- Wind baffles required to operate below 23°F DB in cooling mode.
- Heat pump system with wind baffle: 0°F – 115°F.
- Refer to wind baffle documentation for further information.
**Outdoor Unit Operating Temperature Range (Cooling Thermal Lock-out / Re- start Temperatures; Heating Thermal Lock-out / Re-start Temperatures):
- System cuts out in heating mode to avoid thermistor error and automatically restarts at these temperatures.
***Blue Fin Coating Standard from 2022 production:
- PU(Y/Z)-A(12/18)NKA7 – Beginning with serial number 12U*****
- PU(Y/Z)-A(24/30/36/42)NKA7 – Beginning with serial number 1ZU*****
PLA-A18EA8 & PUZ-A18NKA7
Outdoor Unit
| MCA| A| 11.0
---|---|---|---
MOCP| A| 28
Fan Motor Full Load Amperage| A| 0.5
Fan Motor Output| W| 46
Airflow Rate [Cooling / Heating]| CFM| 1590 / 1590
Refrigerant Control| LEV
Defrost Method| Reverse Cycle
Coating on Heat Exchanger| Blue Fin Coating***
Sound Pressure Level, Cooling1| dB(A)| 44
Sound Pressure Level, Heating2| dB(A)| 46
Compressor Type| INVERTER-driven twin rotary
Compressor Model| SNB130FQCMC-L1
Compressor Rated Load Amps| A| 7
Compressor Locked Rotor Amps| A| 12.0
Compressor Oil [Type // Charge]| oz.| FV50S // 16
External Finish Color| Ivory Munsell 3Y 7.8/1.1
Base Pan Heater| N/A
Unit Dimensions| W x D x H: In. [mm]| 31-13/16 (2+7/16) x 11-13/16 x 24-13/16
[809 (+62) x 300 x 630]
Package Dimensions| W x D x H: In. [mm]| 37-1/16 x 16-3/16 x 27-7/16 [941 x
411 x 697]
Unit Weight| Lbs. [kg]| 100 [45]
Package Weight| Lbs. [kg]| 112 [51]
Outdoor Unit Operating Temperature Range
| Cooling Air Temp [Maximum / Minimum]*| °F| 115 DB / 0 DB
Heating Air Temp [Maximum / Minimum]| °F| 70 DB, 59 WB / 12 DB, 14 WB
Heating Thermal Lock-out / Re-start Temperatures**| °F| 8 / 12
Refrigerant
| Type| R410A
Pre-Charged Refrigerant Amount| Lbs, oz| 4.0, 14.0
Maximum Pre-Charged Piping Length| Ft. [m]| 70.0 [21.0]
Additional Refrigerant Charge Per Additional Piping Length| oz./Ft. [g/m]| 0.2
[19]
Piping
| Gas Pipe Size O.D. [Flared]| In.[mm]| 1/2 [12.7]
Liquid Pipe Size O.D. [Flared]| In.[mm]| 1/4 [6.35]
Maximum Piping Length| Ft. [m]| 100 [30]
Maximum Height Difference| Ft. [m]| 100 [30]
Maximum Number of Bends| 15
NOTES
- AHRI Rated Conditions
- 1Cooling (Indoor // Outdoor)
- °F 80 DB, 67 WB // 95 DB, 75 WB
- (Rated data is determined at a fixed compressor speed)
- 2Heating at 47
- °F (Indoor // Outdoor)
- °F 70 DB, 60 WB // 47 DB, 43 WB3Heating at 17
- °F (Indoor // Outdoor)
- °F 70 DB, 60 WB // 17 DB, 15 WB
- Conditions
- 4Heating at 5°F (Indoor // Outdoor)
- °F 70 DB, 60 WB // 5 DB, 4 WB
*Indoor/Outdoor Unit Operating Temperature Range (Cooling Air Temp [Maximum / Minimum]):
- Applications should be restricted to comfort cooling only; equipment cooling applications are not recommended for low ambient temperature conditions.
- Wind baffles required to operate below 23°F DB in cooling mode.
- Heat pump system with wind baffle: 0°F – 115°F.
- Refer to wind baffle documentation for further information.
**Outdoor Unit Operating Temperature Range (Cooling Thermal Lock-out / Re- start Temperatures; Heating Thermal Lock-out / Re-start Temperatures):
- System cuts out in heating mode to avoid thermistor error and automatically restarts at these temperatures.
***Blue Fin Coating Standard from 2022 production:
- PU(Y/Z)-A(12/18)NKA7 – Beginning with serial number 12U*****
- PU(Y/Z)-A(24/30/36/42)NKA7 – Beginning with serial number 1ZU*****
INDOOR UNIT ACCESSORIES
PLA-A18EA8
Control Interface
| 3-Pin Connector| □ PAC-715AD
---|---|---
Airzone ZBS Wired Blueface Principal Controller White| □ AZZBSBLUEFACECB
Airzone ZBS Wired Blueface Principal Controller White| □ AZZBSBLUEZEROCB
Airzone ZBS Wired Lite Controller White| □ AZZBSLITECB
Airzone ZBS Wireless Lite Controller White| □ AZZBSLITERB
Airzone ZBS Wireless Think Controller White| □ AZZBSTHINKRB
CN24 Relay Kit| □ CN24RELAY-KIT-CM3
IT Extender| □ PAC-WHS01IE-E
kumo station® for kumo cloud®| □ TAC-WHS01HC-E
Procon BACnet® and Modbus® Interface| □ PAC-UKPRC001-CN-1
Remote Operation Adapter‡| □ PAC-SF40RM-E
Thermostat Interface| □ PAC-US445CN-1
USNAP Adapter| □ PAC-WHS01UP-E
Wireless Interface for kumo cloud®| □ PAC-USWHS002-WF-2
Remote Sensor
| Flush Mount Remote Temperature Sensor| □ PAC-USSEN002-FM-1
Flush Mount Temperature Sensor| □ PAC-USSEN001-FM-1
Remote Temperature Sensor| □ PAC-SE41TS-E
Wireless temperature and humidity sensor for kumo cloud®| □ PAC-USWHS003-TH-1
Wired Remote Controller
| Deluxe Wired MA Remote Controller†| □ AAR-40MAAU
Simple Ductless Wired Remote Controller| □ PAC-SDW01RC-1
Simple MA Remote Controller†| □ PAC-YT53CRAU-J
Touch MA Controller†| □ PAR-CT01MAU-SB
Wireless Remote Controller
| kumo touch™ RedLINK™ Wireless Controller| □ MHK2
Lockdown bracket for remote controller| □ RCMKP1CB
Wireless MA Receiver| □ PAR-SR32MA-E
Wireless MA Remote Controller| □ PAR-FL32MA-E
Wireless Remote Contoller| □ PAR-SL101A-E
Wireless Signal Receiver Panel| □ PAR-SR4LU-E
Casement| Multi-function Casement| □ PAC-SJ41TM-E
Condensate
| Blue Diamond (Advanced) Mini Condensate Pump w/ Reservoir & Sensor
(208/230V) [recommended]| □ X87-721
Blue Diamond (MicroBlue) Mini Condensate Pump (110/208/230V) up to 18,000
BTU/H| □ X86-003
Blue Diamond Sensor Extension Cable — 15 Ft.| □ C13-103
Refco Condensate Pump (100-240 VAC) up to 120,000 BTU/H| □ COMBI
Disconnect Switch
| (30A/600V/UL) [fits 2” X 4” utility box] – Black| □ TAZ-MS303
(30A/600V/UL) [fits 2” X 4” utility box] – White| □ TAZ-MS303W
Filter| High Efficiency Filter Element**| □ PAC-SH59KF-E
i-see Sensor® Panel| Grille with 3D i-see Sensor®| □ PLP-41EAEU
Lineset
| 100’ x 1/4” x 100’ / 1/2” Lineset (Twin-Tube Insulation)| □ MLS141212T-100
15’ x 1/4” x 15’ / 1/2” Lineset (Twin-Tube Insulation)| □ MLS141212T-15
30’ x 1/4” x 30’ / 1/2” Lineset (Twin-Tube Insulation)| □ MLS141212T-30
50’ x 1/4” x 50’ / 1/2” Lineset (Twin-Tube Insulation)| □ MLS141212T-50
65’ x 1/4” x 65’ / 1/2” Lineset (Twin-Tube Insulation)| □ MLS141212T-65
Shutter Plate| Shutter Plate| □ PAC-SJ37SP-E
Space Panel| Space Panel| □ PAC-SJ38AS-E
NOTES
‡PAC-SF40RM-E (Unable to use with wireless remote controller)
OUTDOOR UNIT ACCESSORIES
PUZ-A18NKA7
Air Outlet Guide | Air Outlet Guide | □ PAC-SJ07SG-E |
---|
Centralized Drain Pan
| Centralized Drain Pan| □ PAC-SG63DP-E
Drain Pan| □ PAC-SG64DP-E
Control/Service Tool
| Control/Service Tool| □ PAC-SK52ST
M- & P-Series Maintenance Tool Cable Set| □ M21EC0397
USB/UART Conversion Cable (Required for all laptop connection)| □ M21EC1397
Drain Socket| Drain Socket| □ MAC-871DS
Hail Guards| Hail Guard| □ HG-A5
M-NET Converter| M-NET Converter| □ PAC-SJ96MA-E
Mini-Split Wire
| 14 Gauge, 4 wire MiniSplit Cable—250 ft. roll| □ S144-250
14 Gauge, 4 wire MiniSplit Cable—50 ft. roll| □ S144-50
16 Gauge, 4 wire MiniSplit Cable—250 ft. roll| □ S164-250
16 Gauge, 4 wire MiniSplit Cable—50 ft. roll| □ S164-50
Mounting Pad| Condensing Unit Mounting Pad: 16” x 36” x 3”| □ ULTRILITE1
Stand
| 18” Single Fan Stand| □ QSMS1801M
24” Single Fan Stand| □ QSMS2401M
Condenser Wall Bracket| □ QSWB2000M-1
Condenser Wall Bracket – Stainless Steel Finish| □ QSWBSS
Outdoor Unit Stand — 12” High| □ QSMS1201M
Wind Baffle
| Front Wind Baffle| □ WB-PA4
Rear Wind Baffle| □ WB-RE4
Side Advanced Wind Baffle| □ WB-SD4
INDOOR UNIT DIMENSIONS
PLA-A18EA8
NOTE
- CHOOSE THE GRILLE AMONG THE DEDICATED GRILLES.
- REINFORCE THE SUSPENSION BOLT FOR EARTHQUAKE-RESISTANCE AS NEEDED.
- FOR THE SUSPENSION BOLT, USE M10 OR W3/8. (PROCURED AT THE LOCAL SITE.)
- FOR DRAIN PIPE, USE VP-25(O.D. n1-1/4*([ 32) PVC TUBE). DRAIN PUMP INCLUSION. RAISE IS MAX 33-7/16 (850mm) FROM THE CEILING.
- ELECTRICAL BOX MAY BE REMOVED FOR THE SERVICE PURPOSE. MAKE SURE TO SLACK THE ELECTRICAL WIRE LITTLE BIT FOR CONTROL/POWER WIRES CONNECTION.
- THE HEIGHT OF THE INDOOR UNIT IS ABLE TO BE ADJUSTED WITH THE GRILLE ATTACHED.
- REQUIRES “E” OR MORE SPACE BETWEEN THE TRANSOM AND CEILING FOR THE INSTALLATION.
- WHEN INSTALLING THE BRANCH DUCTS, BE SURE TO INSULATE ADEQUATELY. OTHERWISE CONDENSATION AND DRIPPING MAY OCCUR. (IT BECOMES THE CAUSE OF DROPLET OR DROPLET DRIPPING.) |
- AS FOR NECESSARY INSTALLATION/SERVICE SPACE, PLEASE REFER TO THE RIGHT AT FIGURE.
- FOR THE INSTALLATION OF THE OPTIONAL HIGH EFFICIENCY FILTER OR MULTI-FUNCTIONAL CASEMENT,REFER TO SPECIAL DRAWING.
OUTDOOR UNIT DIMENSIONS
PUZ-A18NKA7
Free space around the outdoor unit (basic example)
FOUNDATION BOLTS
Please secure the unit firmly with 4 foundation (M10<W3/8>) bolts. (Bolts,
washers and nut must be purchased locally).
PIPING-WIRING DIRECTION
Piping and wiring connections can be made from the rear direction only.
FORM# PLA-A18EA8 & PUZ-A18NKA7 – 202310 © 2023 Mitsubishi Electric Trane HVAC US LLC. All rights reserved
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>