NIGHTSTICK VM-5422GMX Dual Light Instruction Manual

June 16, 2024
NIGHTSTICK

Instruction Manual
XPP-5422GMX / XPP-5422GMXA

VM-5422GMX Dual Light

THE XPP-5422GMX/GMXA IS APPROVED FOR USE

CAPACITANCE LIMITATION – INTRINSICALLY SAFE

The capacitance measured on the two magnets and the side clip exceeds 3pF as is required for a Group IIC rating. The user should consider this fact when deciding to use this light in their specific application.

WARNINGS – INTRINSICALLY SAFE

  • Warning: Use only the approved non-rechargeable batteries listed below.
  • Warning: Do NOT attempt to use rechargeable AA batteries with this light.
  • Warning: To prevent ignition of a hazardous atmosphere, do not open the lens bezel in the hazardous environment. This task must ONLY be performed in an area known to be non-hazardous.
  • Warning: When exchanging batteries, use only Duracell PC1500, Energizer EN91 or Energizer L91 batteries.
  • Warning: To prevent ignition of a hazardous atmosphere, the AA batteries must only be exchanged in an area known to be non-hazardous.
  • Warning: To reduce the risk of explosion, do not mix new non-rechargeable batteries with used non-rechargeable batteries, or mix non-rechargeable batteries from different manufacturers.
  • Warning: Substitution of components may impair intrinsic safety.

SPECIAL INSTRUCTIONS FOR INTRINSIC SAFETY

For personal safety, always confirm the rating of any known hazardous or potentially hazardous location where the light is to be used.

BATTERY INSTALLATION

WARNING: In order to maintain the Intrinsically Safe Permissible rating, the only AA batteries certified for use with this light are the Duracell PC1500, Energizer EN91 or Energizer L91 batteries.

  • Do not attempt to use any other brand or model of AA batteries with this light.
  • Do not attempt to use any type of rechargeable AA batteries with this light.

Warning: To prevent ignition of a hazardous atmosphere, do not remove the lens bezel or the reflector / battery carrier in the hazard us environment. This task must ONLY be done in an area known to be non-hazardous.

  • Loosen the locking screw located on the side of the lens cap (ATEX model only). NOTE: Do NOT completely remove the screw. It is not necessary and may damage the threads.
    Loosen enough to allow the lens bezel to unscrew.

  • Unscrew the lens bezel from the housing in a counter-clockwise direction.

  • Turn the light upside down and carefully shake the light in order to remove the reflector / battery carrier. Allow the reflector / battery carrier to slide into your hand. WARNING: Do NOT touch the reflector surface with your finger. Doing so may damage the reflector surface.

  • Using 3 – AA Duracell PC1500, Energizer EN91 or Energizer L91 batteries (make sure that all 3 batteries are of the same model), install the batteries in the carrier paying close attention to the markings on the battery carrier for  proper battery terminal polarity alignment.

  • Align the reflector / battery carrier so that the switches on the carrier are aligned with the switches on the housing. Carefully insert the reflector / battery carrier back into the flashlight housing until it is fully seated in the housing.  WARNING: Be careful to not touch the reflector surface with your finger. Doing so may damage the reflector surface.

  • Replace the lens bezel by screwing it onto the housing in a clockwise direction.

  • Tighten locking screw for ATEX models. CAUTION: Do NOT over-tighten. This may damage the threads and impact the light’s Intrinsic Safety.

OPERATION

THE XPP-5422 HAS FOUR SEPARATE LIGHTING MODES:
Momentary Flashlight Mode
Lightly press the top body switch for momentary operation. Release the switch to turn the light off.
Constant-on Flashlight Mode
Press the top body switch until it clicks and then release for constant-on mode. Press and release the top body switch again to turn the light off.
Floodlight Mode
Press the bottom body switch until it clicks and then release for floodlight mode. Press and release the bottom body switch again to turn the light off.
Dual-Light Mode
Turn on both the flashlight and the floodlight at the same time. Press the top body switch to activate the flashlight and press the bottom switch to activate the floodlight. Press and release both body switches to turn the lights off.
WARRANTY
LIMITED LIFETIME WARRANTY
Bayco Products, Inc. warrants this product to be free from defects in workmanship and materials for the original purchaser’s lifetime. The Limited Lifetime Warranty includes the LEDs, housing and lenses. Rechargeable batteries,  chargers, switches, electronics and included accessories are warranted for a period of two years with proof of purchase. Normal wear and failures which are caused by accidents, misuse, abuse, faulty installation and lightning damage are  excluded.
We will repair or replace this product should we determine it to be defective. This is the only warranty, expressed or implied, including any warranty of merchantability or fitness for a particular purpose.
For a complete copy of the warranty, go to www.baycoproducts.com/bayco- productsupport/warranties. Retain your receipt for proof of purchase.

Bayco Products, Inc. XPP-5422GMX
640 S. Sanden Blvd.
Wylie, TX 75098
ID 4003544
INTRINSICALLY SAFE
SECURITE INTRINSEQUE
CLASS I DIV 1 GRPS A-D T3
CLASS II & III DIV 1 GRPS E-G T135C
CLASS I ZONE 0 IIC T3
CLASS II ZONE 20 IIIC T135C

-20ºC ≤ Tamb ≤ +40ºC
1.5V/Cell AA Alkaline
Bayco Products, Inc. XPP-5422GMXA
640 S. Sanden Blvd.
Wylie, TX 75098
ID 4003544

EU/ UK Declaration of Conformity

Whereby declare that the product identified above meets the requirements of the Directives listed low. Therefore, they qualify for free movement within markets comprising the European Union (EU), the open Economic Area (EEA) and the United Kingdom (UK). This declaration is issued under the sole possibility of the manufacturer.
the following EU harmonized, UK designated standards and technical specifications have been applied and evaluated by:

Directives:| ATEX Directive 2014/34/EU| UKSI 2016 No. 1107| Article 34 of the Industrial Safety and Health Act and Article 58-4.
Paragraph 4 of the Enforcement Rule of the same Act.
---|---|---|---
Notified Body:| INTERTEK ITALIA SPA Via Guido Miglioli, 2/A 20063 Cernuous sulk Naviglio (MI)
Italy| INTERTEK TESTING & CERTIFICATION LTD
Academy Place, 1-9 Brook S Brentwood, Essex, CM14 5N United Kingdom| Korea Occupational Safety and Health Agency
| | |
| | |
Standards:| EN 60079-0: 2018| IEC 60079-0: 2018
|
|
|
Type Approval:| | For 542U6XA / 54226XA / 5422GMXA

These Products are fully compliant and do not contain the restricted substances above levels noted in EU and UK RoHS.
Name: Mark Situ
Title: Quality Director
Date: 9th
August2022

Bayco Products, Inc. • 640 South Sanden Blvd.
• Wylie, TX 75098 • 1-800-233-2155
• 1-469-326-9400www.nightstick.com
INS-XPP-5422GMX-GMXA-DL-24

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

NIGHTSTICK User Manuals

Related Manuals