TOPPING E50 High Performance DAC with Three Digital Input User Manual
- June 13, 2024
- TOPPING
Table of Contents
E5O
User manual
E50 High Performance DAC with Three Digital Input
Thank you for purchasing E50!
The E50 s a high-performance DAC with three digital inputs, one RCA unbalanced
output and one TRS balanced output. It can be used as a simple DAC or DAC +
pre-amplifier, we hope it could bring you more fun at enjoying music. Now we
recommend you read this manual so that you can use all the features of E50
correctly.
Introduction to MQA
MQA (Master Quality Authenticated)
MQAIs an award-winning British technology that delivers the sound of the
original master recording. The master MQAfile is fully authenticated and is
small enough to stream or download.
E50 adopts MQA technology to receive and decode MQA audio and provide master-
level sound
Visit mqa.co.uk for more information.
Contents list
ES50 | x 1 |
---|---|
Remote control | x 1 |
USB cable | x 1 |
DC cable | x 1 |
User manual | x 1 |
Warranty card | x 1 |
Note: You can download the drivers and user manual on http://www.topping.audio/.
Attribute
Measured | 15.5cm x 12.9cm x 4.1cm |
---|---|
Weight | 4459 |
Power input | DC5V/A |
Signal input | USB/OPT/COAX |
Line Outoutput | BAL/SE |
Display | LED |
Power consumption in normal usage | <2.5W |
Front panel
1-1 LED screen
1- 2 Remote control receiver
1-3 Multi-function touch button
Display
2-1 Input channel
2-2 Output channel
23 Mute indiCation (It always lights up when muted and disappears when it is
not muted)
2-4 PCM/DSD format indication
2-5 Sample rate/volume display area
2-6 MQA format indication*
*Note: There are three forms of MQA operation modes.
- “MQA”: Indicates that the product is decoding and playing an MQA stream or file, and denotes provenance to ensure that the sound is identical to that of the source material.
- “MQA.”: Indicates itis playing an MQA Studio file, which has either been approved i the studio by the artist/producer orhas been verified by the copyright owner.
- “OFS”: Confirms that the product is receiving an MQA stream or file. This delivers the final unfold of the MQA file and displays the original sample rate
Rear panel
3-1 Right channel 6.35mm TRS balanced output.
3-2 Left channel 6.35mm TRS balanced output
3-3 Right channel single-ended RCA output
3-4 Leftchannel single-ended RCA output
3-5 Coaxial SPDIF input
3-6 Optical SPDIF input
3-7 USB input
3-8 Powerinput
Remote control
4-1 Standby
4-2 Volume up
4-3 Switch to previous input
4-4 Invalid button
4-5 Filter setting
4-6 Automatic standby
47 Mute
4-8 OK button
4-9 Switch to next input
4-10 Volume down
4-11 Output channel switching
4-12 Invalid button
4-13 Brightness*
*Note:
“L-1″,”L-2” and “L-3” respectively indicate low, medium and high brightness
“L-A” has the same brightness as “L-2”. The differences lie in when there is no operation after 30 seconds under “L-A” mode, the screen will be automatically turned off, only displays the current input. For example, when it is in USB input, E50 displays as follow. You can press any button to light up the screen.
Input range
USB IN | PCM 44.1kHz-768kHz/16bit-32bit |
---|
DSD DSD64-DSD512 (Native) , DSD64-DSD256 (DoP)
MQA Full Decode
COAX/OPT IN| PCM 44.1kHz-192kHz/16bit-24bit
DSD DSD64(Dop)
MQA Renderer Decode
Specifications
E50 Decoding parameters (USB In©96kHz)
| SE| BAL
(A-w THD+Nt)| <0.00010% @1kHz| <0.00009% @1kHz
THD
(No-wt 90kBw)| <0.0003% @20-20kHz| <0.0003% @20-20kHz
SNR(A-wt)| 124dB @1kHz| 126dB @1kHz
Dynamic range(A-wt)| 124dB @1kHz| 126dB @1kHz
Frequency Response| 20Hz-20kHz(±0.1dB)| 20Hz-20kHz(±0.1dB)
20Hz-40kHz(±0.3dB)| 20Hz-40kHz(±0.3dB)
Output Level| 2Vrms @OdBFS| 4Vrms @OdBFS
Noise(A-wt)| <1.3uVrms| < 2.3uVrms
Crosstalk| -130dB @1 kHz| -139dB @1 kHz
Channel Balance| 0.3 dB| 0.3 dB
Output Impedance| 200| 1000
Operation
Power on & off / standby operation :
- Power on: When connects to power supply, E50 goes into the standby state, the screen displays a bright dot.
- Standby setting:
When it is working, press and hold the multi-function touch button on the front panel to enter standby state and short press to exit standby state when it is in standby. Or you can directly press the standby button on remote control to enter or exit standby state
Note:
When the automatic standby function is on, if the current input
is not connected or input signal is invalid in 1 minute, it will
automatically enter the standby state.Once having detected
valid signal, it will automatically return to working state
Volume setting:
- The enter and exit of mute state: Press the mute button on the remote control to set mute, press the mute button again or adjust the volume to exit mute state.
- Volume adjusting: Adjust volume by pressing the up/down button on the remote control. Press and hold the up/down button will quickly adjust the volume, so please be careful in order to protect your hearing.
Note: Volume is fixed to 0dB in DAC mode and volume adjusting is invalid
in this mode.
Input channel switching : Press the multi-function touch button on the
front panel or the “Switch to previous input button” and the “Switch to next
input button” on the remote control to switch the input in cycle.
Output channel switching : Press the “Output channel switching” button on
the remote control or double press the touch button on the front panel to
switch the output channel. “0-1” indicates only RCA output; “0-2” indicates only TRS output; “0-3” indicates that RCA and TRS are output at the same time.
Setup Menu
Enter the setup menu:
In the standby state, press and hold the multi-function touch button on the
front panel for 3 seconds to enter the setup menu of E50
Change and save of settings:
- The touch button on the front panel: press the touch button to enter the next setting item, double press the touch button to set different parameters. Press and hold the touch button until “8-8” is displayed on the screen to save the settings.
- The remote control: press the volume up/down button to enter the previous/next setting item, press the left/right button to set different parameters. Press and hold the “OK button” until “8-8” is displayed on the screen to save the settings
Setting descriptions:
PCM filter setting (available for remote control setting, set PCM filter mode when playing PCM)
Description | Description |
---|---|
F-1 | Fast roll off linear(Default) |
F-2 | Slow roll off linear |
F-3 | Fast roll off minimum |
Screen brightness setting (Available for remote control setting)
Screen display | Description |
---|---|
L-1 | Low |
L-2 | Mid (Default) |
L-3 | High |
L-A | Mid brightness and screen will be turned off |
automatically after 30 seconds of no operation
Automatic standby s etting (avaiast orarmots contlsoting)
Screen display | Description |
---|---|
A-O | Auto on(Defaul) |
A-C | Auto off |
Line Out channel setting (Available for remote control setting)
Screen display | Description |
---|---|
o-1 | RCA Outputonly |
o-2 | TRS Outputonly |
o-3 | RCASTRS Output simultaneously (Defaut] |
Output mode setting
Screen display | Description |
---|---|
m-p | Per-Amp MOde(Volume adjustable) (Default) |
m-d | DAC mode(Volume nonadjustable) |
Factory reset:
In standby mode, press the Volume down, Volume up and Mute buttons on the
remote control in sequence to restore the factory settings.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>