Sinum PS-08 Din Rail Relay User Manual

June 16, 2024
Sinum

Sinum PS-08 Din Rail Relay

Sinum-PS-08-Din-Rail-Relay-fig-1

Specifications

  • Power Supply: [Napicie zasilania]
  • Nominal Load of Voltage-Free Contact 1-8 : [Nominalne obcienie styku beznapiciowego 1-8]
  • Operation Temperature: [Temperatura pracy]
  • Acceptable Ambient Relative Humidity: [Dopuszczalna wilgotno wzgl. otoczenia]

Product Usage Instructions

Power Supply
The device requires a power supply of [Napicie zasilania]. Ensure that the power supply meets the specified requirements.

Connecting the Device
To connect the device, follow these steps:

  1. Ensure that the power supply is connected properly.
  2. Connect the device to the desired output by using the voltage-free contacts 1-8.

Setting up Communication
The device supports wireless communication. To set up communication, follow these steps:

  1. Go to the “Devices” menu on your device.
  2. Select “Wireless devices”.
  3. Press the registration button 2 on the device briefly.
  4. After a properly completed registration process, an appropriate message will appear on the screen.
  5. Optionally, you can name the device and assign it to a specific room.

FAQ

  • What is the power consumption of the device?
    The maximum power consumption of the device is [Max. power consumption].

  • What is the maximum transmission power of the device?
    The maximum transmission power of the device is [Max. transmission power].

INTRODUCTION

The PS-08 module is an electronic device equipped with 8 independent voltagefree relays enabling the user to control 8 independent devices. It is designed to be mounted on a DIN rail. It communicates with the Sinum central device using radio signal.

Description

  •  – Power supply
  •  – Communication – a single signal indicates a radio signal
  •  – Current status of the voltage-free output (ON/OFF)

Manual mode

Sinum-PS-08-Din-Rail-Relay-fig-2

In order to switch to the manual operation mode, press the manual operation button 1 . The registration button 2 is used to switch between the controlled outputs in the manual mode. Using the button 1 (pressing it once), the user forces a change of the status (ON / OFF) – if the process has been successful, it is confirmed by a light signal from the LED labelled 1-8. When the manual mode is on, it is impossible to control the contact via the website or the application. To disable the manual operation mode, press and hold the button 1 again and hold it for 1-2 seconds. Once the manual mode has been switched off, all the output status LEDs go off and resume the state set in the Sinum application.

How to register the device in the sinum system

Enter the address of the Sinum central device in the browser and log in to the device. In the main panel, click the Settings > Devices > Wireless devices > + Then briefly press the registration button 2 on the device. After a properly completed registration process, an appropriate message will appear on the screen. Additionally, the user can name the device and assign it to a specific room.

Technical data

  • Power supply 230V ±10% /50Hz
  • Max. power consumption 3W
  • Rated load of the voltage-free contact 1-8
    • 230V AC / 0,5A (AC1)*
    • 24V DC / 0,5A (DC1)**
  • Operation temperature 5°C ÷ 50°C
  • Acceptable ambient relative humidity <80% REL.H
  • Operation frequency 868 MHz
  • Max. transmission power 25 mW
    • AC1 load category: single-phase, resistive or slightly inductive AC load
    • DC1 load category: direct current, resistive or slightly inductive load.

NOTE

  • TECH Controllers is not responsible for any damages resulting from improper use of the system. The range depends on the conditions in which the device is used and the structure and materials used in the object construction. The manufacturer reserves the right to improve devices, update software and related documentation. The graphics are provided for illustration purposes only and may differ slightly from the actual look. The diagrams serve as examples. All changes are updated on an ongoing basis on the manufacturer’s website.
  • Before using the device for the first time, read the following regulations carefully. Not obeying these instructions may lead to personal injuries or controller damage. The device should be installed by a qualified person. It is not intended to be operated by children. It is a live electrical device. Make sure the device is disconnected from the mains before performing any activities involving the power supply (plugging cables, installing the device etc.). The device is not water resistant.

DISPOSAL

The product may not be disposed of to household waste containers. The user is obliged to transfer their used equipment to a collection point where all electric and electronic components will be recycled.

EU Declaration of conformity

  • Tech Sterowniki II Sp. z o.o. , ul. Biała Droga 34, Wieprz (34-122)
  • Hereby, we declare under our sole responsibility that the PS-08 is compliant with Directive 2014/53/EU.

Sinum-PS-08-Din-Rail-Relay-fig-4

WEB:www.tech-controllers.com/manuals

Service

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Sinum User Manuals

Related Manuals