Sinum PS-08 Relay 8 way 230V User Manual

June 16, 2024
Sinum

Sinum PS-08 Relay 8 way 230V

Sinum-PS-08-Relay-8-way-230V-product

Product Information

Specifications

  • Power supply: PS-08 230V
  • Max. power consumption: 0.3A
  • Potential contacts 1-8 max. output load
  • Operation temperature
  • Acceptable ambient relative humidity
  • Operation frequency
  • Max. transmission power

Product Usage Instructions

Power Supply

The product requires a power supply of PS-08 230V. Please ensure that the power supply is connected properly before use.

Potential Contacts

The product has potential contacts labeled as 1-8. These contacts are used for various purposes and can handle a maximum output load. Please refer to the user manual for detailed information on how to use each contact.

Operation Temperature and Ambient Relative Humidity

The product has a specific operating temperature and acceptable ambient relative humidity requirements. Please ensure that the product is operated within the specified temperature range and under acceptable humidity conditions to maintain optimal performance.

Operation Frequency and Transmission Power

The product operates at a specific frequency and has a maximum transmission power. Please ensure that the product is operated within the specified frequency range and transmission power limits for proper functioning.

Frequently Asked Questions (FAQ)

Q: How do I register the device to the Sinum system?

A: To register the device to the Sinum system, please follow the registration instructions provided in the user manual.

Q: Where can I find technical support and service contacts?

A: You can find technical support and service contacts for different regions in the user manual. Please refer to the respective contact details based on your location.

OVERVIEW

The PS-08 230V module is an electronic device equipped with 8 independent voltage relays enabling the user to control 8 independent devices. It is designed to be mounted on a DIN rail. It communicates with the Sinum central device using a radio signal.

Description

  • Power supply
  • Communication – a single signal indicates a radio signal
  • 1-8 – Current status of the voltage output (ON/OFF)

Manual mode

In order to switch to the manual operation mode, press the manual operation button 1. The registration button 2 is used to switch between the controlled outputs in the manual mode. Using the button 1 (pressing it once), the user forces a change of the status (ON / OFF) – if the process has been successful, it is confirmed by a light signal from the LED labeled 1-8. When the manual mode is on, it is impossible to control the contact via the website or the application. To disable the manual mode, press the button 1 again and hold it for 1-2 seconds. Once the manual mode has been switched off, all the output status LEDs go off and resume the state set in the Sinum application.

How to register the device in the sinum system

Enter the address of the Sinum central device in the browser and log in to the device. In the main panel, click Settings > Devices > Wireless devices > + Then briefly press the registration button 2 on the device. After a properly completed registration process, an appropriate message will appear on the screen. Additionally, the user can name the device and assign it to a specific room.

Technical data

  • Power supply 230V ±10% /50HzM
  • Max. power consumption 4,5W
  • Potential contacts 1-8 max. output load 0,3A
  • Operation temperature 5°C ÷ 50°C
  • Acceptable ambient relative humidity <80% REL.H
  • Operation frequency 868 MHz
  • Max. transmission power 25 mW

Notes

  • TECH Controllers is not responsible for any damages resulting from improper use of the system. The range depends on the conditions in which the device is used and the structure and materials used in the object construction. The manufacturer reserves the right to improve devices and update software and related documentation. The graphics are provided for illustration purposes only and may differ slightly from the actual look. The diagrams serve as examples. All changes are updated on an ongoing basis on the manufacturer’s website.
  • Before using the device for the first time, read the following regulations carefully. Not obeying these instructions may lead to personal injuries or controller damage. The device should be installed by a qualified person. It is not intended to be operated by children. It is a live electrical device. Make sure the device is disconnected from the mains before performing any activities involving the power supply (plugging cables, installing the device, etc.). The device is not water resistant.
  • The product may not be disposed of in household waste containers. The user is obliged to transfer their used equipment to a collection point where all electric and electronic components will be recycled. EU Declaration of Conformity

Tech Sterowniki II Sp. z o.o. , ul. Biała Droga 34, Wieprz (34-122)
Hereby, we declare under our sole responsibility that the PS-08 230V is compliant with Directive 2014/53/EU. Wieprz, 01.06.2023

The full text of the EU Declaration of Conformity and the user manual are available after scanning the QR code or at www.tech- controllers.com/manuals

tel: +48 33 875 93 80
[email protected]

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Sinum User Manuals

Related Manuals