Sinum FR-S2 Room Regulator User Guide

June 13, 2024
Sinum

Sinum FR-S2 Room Regulator

Sinum-FR-S2-Room-Regulator-product

Product Information

The FR-S2 room regulator is a device equipped with a temperature and air humidity sensor. It is designed to measure and display current temperature and humidity readings. The device communicates with the Sinum Central device through a wired connection. It is mounted to an electrical box with a diameter of 60 mm.

Product Usage Instructions

  1. To identify the device in the Sinum system, follow these steps:
    • Go to Settings > Devices > SBUS Devices > + > Identification Mode tab on the Sinum Central device.
    • Hold the registration button on the FR-S2 room regulator for 3-4 seconds.
    • The device will be highlighted on the screen of the Sinum Central device.
  2. To operate the FR-S2 room regulator in the Sinum Central device:
    • If the regulator is assigned to a virtual thermostat, the icon on the display will indicate the heating or cooling mode.
    • A steady icon indicates the room is being heated (heating mode).
    • A blinking icon indicates the room is being cooled (cooling mode).
    • No icon indicates no need for heating or cooling.
    • To change the desired temperature, use the navigation buttons to select the desired temperature range.
    • Press the Menu button to confirm the selection.
    • If the regulator is assigned to a virtual thermostat, after changing the temperature, use the navigation buttons to specify the time range for which the desired temperature should apply.
    • Press the Menu button to confirm the selection or wait for approximately 5 seconds.
    • Simultaneously holding the Main button and the Navigation buttons locks or unlocks the buttons.
  3. To set the position of the terminating resistor on the transmission line with the Sinum Central device:
    • Locate the terminating resistor connector (labeled as 5) on the FR-S2 room regulator.
    • Set the terminating resistor switch to either ON (regulator at the end of the line) or 1 (regulator in the middle of the line).

If you need further assistance or have any questions, please contact our customer service.

The FR-S2 room regulator is equipped with a temperature and air humidity sensor. Current measurements are displayed on the device and sent to the Sinum Central device, where they can be freely used to create various automations. Communication with the Sinum Central device, is done by wire. The regulator is mounted to an electrical box with a diameter of 60 mm.

Opis

  1. Registration button
  2. Main button
  3. Navigation buttons
  4. SBUS communication connector
  5. Terminating resistor

Sinum-FR-S2-Room-Regulator-fig- \(17\)

How to register the device in the sinum system

The device should be connected to the Sinum central device using the SBUS connector 4 , and then enter the address of the Sinum central device in the browser and log in to the device. In the main panel, click the Settings > Devices > SBUS devices > > Add device. Then briefly press the registration button 1 on the device. After a properly completed registration process, an appropriate message will appear on the screen. Additionally, the user can name the device and assign it to a specific room. INFO: When registering the regulator, the humidity sensor will also be registered automatically.

How to identify the device in the Sinum system

To identify the device in the Sinum Central, activate the Identification Mode in the Settings > Devices > SBUS Devices > > Identification Mode tab and hold the registration button on the device for 3-4 seconds. The device used will be highlighted on the screen.

Operation

  • Heating/cooling control * (icon ) is possible after assigning the controller in the Sinum Central device to a virtual thermostat. On the display, the icon can have different meaning:
    • the icon is on permanently – heating of the room (heating mode)
    • the icon is blinking – room cooling (cooling mode)
    • no icon – no need for heating/cooling
  • Changing the preset temperature with the and buttons and confirming with the Menu button . The set temperature will be permanent. If the regulator is assigned to a virtual thermostat, after changing the temperature, use the and to specify the time range of the set temperature [0 ÷ 24h, Con (permanently) or Off (inactive change)], confirm with the Menu button .
  • Button lock – pressing the Menu button will activate the function ; use the or to select „yes” or „no” (automatic lock on/off). Confirm with the Menu button or wait approx. 5 sec. Holding and simultaneously until the padlock icon disappears unlocks the buttons.
  • Controller connection – the system has a terminating connection. The position of the regulator on the transmission line with the Sinum Central is determined by the position of the terminating switch 5 . Set to ON position (regulator at the end of the line) or position 1 (regulator in the middle of the line).

Option available depending on the program version

Hold down the Menu buttton until appears option. change options with and , confirm with Menu button. Options available:

  • temperature sensor calibration,
  • activation/deactivation of the button lock; to unlock, hold down the and buttons simultaneously for 3 seconds,
  • device registration,
  • software information,
  • service menu,
  • factory reset,
  • exit from the Menu,

Technical data

  • Power supply 24V DC ±10%
  • Max. power consumption 0,1W
  • Humidity measurement range 10 – 95%
  • Room temperature setting range 5 ÷ 35°C

Safety Notes

TECH Controllers is not responsible for any damages resulting from improper use of the system. The manufacturer reserves the right to improve devices, update software and related documentation. The graphics are provided for illustration purposes only and may differ slightly from the actual look. The diagrams serve as examples. All changes are updated on an ongoing basis on the manufacturer’s website. Before using the device for the first time, read the following regulations carefully. Not obeying these instructions may lead to personal injuries or controller damage. The device should be installed by a qualified person. It is not intended to be operated by children. It is a live electrical device. Make sure the device is disconnected from the mains before performing any activities involving the power supply (plugging cables, installing the device etc.). The device is not water resistant.

  • The product may not be disposed of to household waste containers.
  • The user is obliged to transfer their used equipment to a collection point where all electric and electronic components will be recycled.

Declaration of conformity

EU Declaration of conformity

Tech Sterowniki II Sp. z o.o. , ul. Biała Droga 34, Wieprz (34-122) Hereby, we declare under our sole responsibility that the room regulator FR-S2 is compliant with Directive:

  • 2014/35/UE
  • 2014/30/UE
  • 2009/125/WE
  • 2017/2102/UE

For compliance assessment, harmonized standards were used:

  • PN-EN IEC 60730-2-9:2019-06
  • PN-EN 60730-1:2016-10
  • EN IEC 63000:2018 RoHS

Wieprz, 01.07.2023

The full text of the EU declaration of conformity and the user manual are available after scanning the QR code or at www.tech- controllers.com/manuals.

TECH STEROWNIKI II Sp. z o.o.
ul. Biała Droga 31 34-122 Wieprz

Service

Made in Poland.