Signify LED GEN 2 FPZ LED Backlit Panel Installation Guide

June 16, 2024
signify

**Signify LED GEN 2 FPZ LED Backlit Panel Installation Guide

**

Safety Information

IMPORTANT : THIS PRODUCT MUST BE INSTALLED IN ACCORDANCE WITH THE APPLICABLE NATIONAL ELECTRICAL CODE AND LOCAL BUILDING CODES BY A PERSON FAMILIAR WITH THE CONSTRUCTION AND OPERATION OF THE PRODUCT AND THE HAZARDS INVOLVED.

SAVE THESE INSTRUCTIONS.

WARNING : Before installation or servicing, turn the power OFF at the circuit breaker or fuse. Place tape over the circuit breaker switch and verify power is OFF at the light fixture.

WARNING : Ground the fixture to avoid potential electric shock

WARNING : Wear gloves when handling the fixture as edges are sharp.

CAUTION : Connect the fixture to a 120/277 Volt, 60 Hz power source. Any other connection voids the warranty.

Specifications

Voltage 120-277Vac 50/60Hz
Dimming 0-10V
Operating Temperature Range -20°C+25°C
Ceiling Type Exposed T-bar ceiling
Light Source Non-replaceable LED

Drawing Dimensions

Pre-Installation (continued)

Mounting Options

  • Recessed

  • Surface
    (requires Surface Mount Kit)

  • Suspension
    (requires Cable Mount Kit)

Mounting Kit Description

Mounting Kit Description

  • 2-Cable Mount Kit
  • 4-Cable Mount Kit
  • 2×2 Surface Mount
  • 2×4 Surface Mount

Tools Required

  • goggles Safety

  • Drill

  • Ladder

  • Electrical tape

  • Phillips screwdriver

  • Flathead screwdriver

  • Wire cutters

  • Wire strippers

  • Hammer

Hardware Included

  • AA – Wire nuts x5

Before You Begin

  1. Turn off the electricity at the circuit breaker or fuse box.
  2. Choose your installation option:
    • Installation Option 1 – Flush Mount
    • Installation Option 2 – Surface Mount (Sold Separately)
    • Installation Option 3 – Cable/ Suspension Mount (Sold Separately)

Installation Option 1 – Recessed Mount

WARNING : Before you begin, turn the power off at the circuit breaker or fuse box to avoid electric shock.

  1. Removing the ceiling panel
    a. Remove the plasterboard panel from the ceiling.

  2. Connecting the wires
    a. Lift the fixture to the ceiling.
    b. Follow the steps in the Making the Electrical Connections section of this manual.

  3. Completing the installation
    a. Slide the fixture into place in the ceiling.
    b. Restore power to the fixture.

Making the Electrical Connections

WARNING : Before you begin, turn the power off at the circuit breaker or fuse box to avoid electric shock.

  1. Open the junction box
    a. Unscrew and remove the junction box cover (1) from the fixture.

  2. Connect the supply wires
    a. Connectthe green ground wire from the fixture to the supply ground wire.
    b. Connect the white wire from the fixture to the supply white wire (neutral wire).
    c. Connect the black wire from the fixture to the supply black wire (live wire).
    d. Secure the three connections using three wire nuts (AA).
    e. Wrap the three wire connections with electrical tape for a more secure connection.

  3. Connect the dimming wires
    a. Connect the purple wire from the fixture to the purple (DIM+) supply wire.
    b. Connected gray wire from the fixture to the gray (DIM-) supply wire.
    c. Secure the two connections using two wire nuts (AA).
    d. Wrap the two wire connections with electrical tape for a more secure connection.

  4. Reinstall the junction box cover
    a. Position the wires back inside the junction box.
    b. Reinstall the junction box cover (1).