SALTO CUC1B0 BLUEnet Door Controller Installation Guide
- June 16, 2024
- SALTO
Table of Contents
**SALTO CUC1B0 BLUEnet Door Controller
**
DIMENSIONS
CUC1B0 series
Wireless door controller for 1 door access control with BLE.
Installation
ELECTRICAL CABINET WITH DIN RAIL
ELECTRICAL CABINET WITH DIN RAIL AND TAMPER
In the software, set the connection that you’ve connected the tamper wire to as “Tamper input”.
Wiring
- Input/Output: power input/output and proprietary serial bus for communication with expansion boards. There are two groups of connections that are %100 identical.
- Relay outputs: (1A/30VDC).
- Connection with the wall reader: consult the wall reader installation guide for more detailed information about the type of recommended wiring, connections and maximum distances.
- Inputs: inputs for external configuration (default, IN2, tamper).
- CLEAR button: short press to pair with the connected wall reader and discover and pair devices on the proprietary serial bus; long press will accept a new Portable Programmer (PPD), only in the Space platform.
Factory configuration inputs and relays
FACTORY CONFIGURATION
IN1| Door status *| Unsupervised NC
IN2| Exit| Unsupervised NO
RL1| Door relay|
RL2| Tamper alarms, loss of communication, DLO and intrusion|
CUAPAC or third party readers
| WIEGAND
---|---
IN1| Input D0
IN2| Input D1
POWER | Min | Max | Typ |
---|---|---|---|
Input voltage | 10V | 30V | 12V |
Max Current Consumption* | 700mA | ||
Reader output Voltage | 12V |
* This is the consumption of the CUC1B0 series, installer must calculate the power supply needed
| INPUT
---|---
Electrical characteristics| 5V
Configuration| Via Software
CABLE REQUIREMENTS
EXT BUS| 22 – 16 AWG (≤1m)|
Inputs| AWG24|
Readers| AWG18|
| INPUT
---|---
Electrical characteristics| 5V
Configuration| Via Software
OPERATING CONDITIONS
Temperature| -35ºC| 70ºC
Humidity| 0| 95% (Non condensing)
OUTPUT RELAYS
Rated load (resistive)| 1A – 30Vdc
Applies to CUC1B0 model only!
SALTO BLUEnet CHARACTERISTICS
Frequency Range| 2400 MHz to 2483.5 MHz
Standard| Bluetooth 4.2
TX power| 6dBm
Indoor Range| 5-10m *
*The environment has a direct impact on the BLUEnet range radiation (metal, concrete walls…). The receiver device must be located facing the product antenna.
Please check your product´s BLUEnet antenna position. Recommended connectivity
distance 5-10m.
Installation example
Cable connection
B | Green |
---|---|
A | White |
– | Black |
+ | Red |
- NC Switch Door
- NO Switch RTE
- Electric Strike
- Strike Protection Varistor
Installation example
Signaling
LED STATUS | CUC1B0 | CUCEB122 |
---|---|---|
BLINKING YELLOW | Long press off CLR | Not paired with CUC180 |
OFF | No power | |
SOLID GREEN | All internal communications established and working correctly |
(serial Bus owner WRs)
SOLID RED| After booting device indicates if it was powered correctly. The
light will remain red if there are no internal communications established
BLINKING RED| Communication problems (serial Busowner WR)
Operational test
Once the control unit has been installed, to check it has been installed correctly, make sure that when powering the device, the LED is solid green.
All contents current at time of publication.