SALTO WRDx0A4 Series Wall Reader Keypad Entry System Installation Guide

June 4, 2024
SALTO

SALTO WRDx0A4 Series Wall Reader Keypad Entry System Installation Guide

Card reader installation guide

installation

GANG ELECTRICAL STANDARD BOX

Electrical characteristics

Operation conditions
  Min. Max.   Unit
Temperature WRD0B – WRD0S – WRD0BK -35

-31

| +66          °C

+150   °F

Temperature WRD0J – WRD0GK – WRD0JK| -25| +66| °C
-13| +150| °F
Temperature WRD0BF – WRD0JF| -20| +66| °C
-4| +150| °F
Humidity| 35| 85           %

RF characteristics
Min Cen. Max Unit

RFID frequency

Bluetooth Smart 2.4 frequency

| 13.56

2.445

|

2.4835

| Mhz

Ghz

Power Consumption Note 1
Min Max Unit
Reader 150 mA
Reader+Keyboard 250 mA
Reader+Keyboard+Fingerprint 300 mA

Note 1: Installer must take this data into account to dimension the CU42xx power supply.
Readers only for use with the SALTO Control Units.
Note 2: Not use with Scotchlok butt connector UY2 SALTO recommends to use one cable per wall reader

Cable type and max. Distances

Cable type

|

Reader

| Reader Keypad| Reader

Keypad Fingerpint

---|---|---|---
UTP Cat5e

2 pairs AWG24

| 328ft

100m

| 196ft

60m

| 164ft

50m

UTP Cat5e

4 pairs AWG24 SP224861/SP224895

| 820ft 250m| 492ft 150m| 328ft 100m
Twisted pairs AWG18 Note2| 1312ft

400m

| 918ft

280m

| 756ft

200m

Note: UL tested at 24 AWG at 100m.

Installation example: CU42xx:

Cable connection

Eng Esp Fra Deu Ned Sve

B

A

__

| Green

Yellow Black

| Verde

Amarillo Negro

| Vert

Jaune Noir

| Grün

Gelb Schwarz

| Groen

Geel Zwart

| Grön

Gul Svart

+V| Red| Rojo| Rouge| Rot| Rood| Röd

Installation example CU42xx with RJ45:

Minimum distance between readers 20in (50cm).

UL Statements

Tested by UL with Mifare (DESFIRE, ULTRALIGHT C) and HID iCLASS RFID communication, and with Mobile APP (JustIN Movile version 2.x) through Bluetooth version 4.2. Minimum Operating System version for Android: 4.3 or later and for iOS: 10.0 or later. Ameans of verification shall be employed by the user to enable access to the wireless electronic device such as a PIN or biometric feature.
The wireless electronic device is not capable of command, control, programming, or any other system manipulation and it is only to be used in the same manner as a physical credential. Wiring methods that shall be in accordance with the National Electrical Code, ANSI/NFPA 70 or CSA C22.1-02 – Canadian Electrical Code, Part 1, Safety Standard for Electrical Installations.

UL294 performance level:

FEATURE LEVEL
Destructive attack I
Line Security I
Endurance IV
Standby power Per rating of the power supply

Comply with ULC-S319 Class I

This device complies with Industry Canada license-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Changes or modifications not    expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.