DELL MXL System Release Notes OS Version 9.14 1.12 User Guide

June 12, 2024
Dell

DELL-LOGO

DELL MXL System Release Notes OS Version 9.14 1.12

DELL-MXL-System-Release-Notes-OS-Version-9.14 1.12-PRODUCT-
IMAGE

Product Information

Document Revision Rev. A00 May 2022
Current Release Version 9.14(1.12)
Release Date 2022-05-20
Supported Hardware MXL 10/40GbE Switch IO Module: base module

4-Port 10-Gigabit Ethernet SFP+ module
2-Port 40-Gigabit Ethernet QSFP+ module
4-Port 10GBASE-T module
4-port 2/4/8G FC Flex IO Module
New Features in Version 9.14(1.12)| None
Restrictions| Fanning out SM4 optics is not supported. If you want to
downgrade from Dell Networking OS version 9.14(1.12) to an earlier
version, you must power cycle the I/O modules using CMC.

QSFP+ High-Power Optics Usage:

  • High-Power Optics is Inserted and Peer Port has No Optics: The
    peer port is disabled. The peer port gets enabled right after the
    high-power optics are removed.

  • High-Power Optics is Inserted and Peer Port has High/Low Power
    Optics: The current port will be locked as the peer port is already
    in use. The user can remove any one of these optics based on their
    requirement.

Product Usage Instructions

  1. Ensure that you have the Dell Technologies Chassis Management Controller (CMC) version 4.11 or later installed in a Dell Technologies PowerEdge M1000e Enclosure to use an MXL 10/40GbE Switch IO module running Dell Networking OS version 8.3.16.3 or later.

  2. Use the CMC out-of-band management interface to access and manage an MXL Switch using the Dell Networking OS command-line interface. For more information, refer to the Dell
    Chassis Management Controller Firmware User’s Guide on the Dell Support website.

  3. To configure server-facing ports, follow these steps:

  4. On each server-facing port, enter the following commands in Interface Configuration mode:

                   Dell# interface tenGigabitEthernet 0/1
           Dell(conf-if-te-0/1)# portmode hybrid
           Dell(conf-if-te-0/1)# switchport
           Dell(conf-if-te-0/1)# protocol lldp
           Dell(conf-lldp)# dcbx port-role auto-downstream
           Dell(conf-lldp)# dcbx version cee
           Dell(conf-lldp)# exit
           Dell(conf-if-te-0/1)# spanning-tree pvst edge-port
           Dell(conf-if-te-0/1)# no shutdown
           Dell(conf-if-te-0/1)# exit
           Dell#
  5. Configure server-facing ports with the shutdown and no shutdown commands as needed.

Dell MXL System Release Notes, OS Version 9.14(1.12)
This document contains information on open and resolved caveats, and operational information specific to the Dell Networking OS software and the MXL platform.

  • Current Release Version: 9.14(1.12)
  • Release Date: 2022-05-20
  • Previous Release Version: 9.14(1.10)

Topics:

  • Document Revision History
  • Prerequisites
  • Supported Hardware
  • New Dell Networking OS Version 9.14(1.12) Features
  • Restrictions
  • Changes to Default Behavior and CLI Syntax
  • Documentation Corrections
  • Deferred Issues
  • Fixed Issues
  • Known Issues
  • MXL Upgrade Procedures: Overview
  • Upgrading the Dell Networking OS Image, Boot Flash and Boot Selector Images
  • Upgrading the CPLD
  • VLT Upgrade Procedure
  • Support Resources

Caveats are unexpected or incorrect behavior, and are listed in order of Problem Report (PR) number within the appropriate sections.
For more information on hardware and software features, commands, and capabilities, refer to the Dell Networking support website at: https://www.dell.com/support

Document Revision History
Table 1. Revision History

Date Description
2022–05 Initial release.

Prerequisites
The Dell Technologies Chassis Management Controller (CMC) version 4.11 or later is required in a Dell Technologies PowerEdge M1000e Enclosure to use an MXL 10/40GbE Switch IO module running Dell Networking OS version 8.3.16.3 or later.
You can use the CMC out-of-band management interface to access and manage an MXL Switch using the Dell Networking OS command-line interface. For more information, refer to the Dell Chassis Management Controller Firmware User’s Guide on the Dell Support website at http://support.dell.com/support/edocs/systems/pem/en/index.htm.

Supported Hardware
The following hardware is supported with this platform:

Hardware

MXL 10/40GbE Switch IO Module: base module
4-Port 10-Gigabit Ethernet SFP+ module
2-Port 40-Gigabit Ethernet QSFP+ module
4-Port 10GBASE-T module
4-port 2/4/8G FC Flex IO Module

New Dell Networking OS Version 9.14(1.12) Features

The following features have been added to the MXL with Dell Networking OS version 9.14(1.12):
None.

Restrictions

  • Fanning out SM4 optics is not supported.

  • If you want to downgrade from Dell Networking OS version 9.14(1.12) to an earlier version, you must power cycle the I/O modules using CMC.

  • QSFP+ High-Power Optics Usage — Scenarios

    • High-Power Optics is Inserted and Peer Port has No Optics — The peer port is disabled. The peer port gets enabled right after the high-power optics are removed. Both ports are available in the case of low power optics (40G SR4/CR4). The system generates the following syslog:
      INSERT_OPTICS_HP_QSFP_PEER_PORT_DISABLE: Optics 40GE High power QSFP+ is inserted in port 0/33 and peer port 0/37 is disabled for Optics as only one High power optic can be enabled.
      High-Power Optics is Inserted and Peer Port has High / Low Power Optics — The current port will be locked as peer port is already in use, and the system can only support a high-power optic or a pair of low-power optics in fixed ports, as well as in a QSFP module. The user can remove any one of these optics based on their requirement. The system generates the following syslog:
      INSERT_OPTICS_HP_QSFP_PORT_DISABLE: Optics 40GE High power QSFP+ is inserted in port 0/49 and it is not activated unless peer port 0/53 optics is removed as only one High power optic can be enabled. Please remove any one of the optics to avoid any potential thermal overheating to the hardware.

    • Low-Power Optics is Inserted and Peer Port has High-Power Optics — The current port is already locked because of the peer port high-power optics. So the current port is already in disabled state. The user can remove any one of these optics based on their requirement. The system generates the following syslog:
      INSERT_OPTICS_QSFP_DISABLED_PORT: Optics 40GE QSFP+ is inserted in port 0/49 and it is not activated unless peer port 0/53 High Power optics is removed as only one High power optic can be enabled. Please remove any one of the optics to avoid any potential thermal overheating to the hardware.

  • If an Intel X520 CNA adapter is used as an FCoE initiator, follow these steps to establish FCoE sessions to send and receive traffic:

  1. On the server, uninstall the old Intel driver (version 13.0.0 or older).

  2. Re-install the Intel driver using version 13.5 A00 (or later) from the http://www.dell.com website.
    Important: During the installation, do not select the ISCSI part of the driver; select only the FCoE check box.

  3. On each server-facing port, enter the following commands in Interface Configuration mode. The dcbx version cee command configures a port to use the CEE (Intel 1.01) version of DCBX. Configure server-facing ports with the shutdown and no shutdown commands as needed.
    For example:
    Dell# interface tenGigabitEthernet 0/1
    Dell(conf-if-te-0/1)# portmode hybrid
    Dell(conf-if-te-0/1)# switchport
    Dell(conf-if-te-0/1)# protocol lldp
    Dell(conf-lldp)# dcbx port-role auto-downstream Dell(conf-lldp)# dcbx version cee
    Dell(conf-lldp)# exit
    Dell(conf-if-te-0/1)# spanning-tree pvst edge-port Dell(conf-if-te-0/1)# no shutdown
    Dell(conf-if-te-0/1)# exit
    Dell#

  4. Display information on FIP-snooped sessions and check the entries in ENode Interface fields to see if you have established the FCoE session on a server-facing port.

show fip-snooping sessions EXEC Privilege

  • The following features are not available in the Dell Networking OS from version 9.7(0.0):

    • PIM ECMP
    • Static IGMP join (ip igmp static-group)
    • IGMP querier timeout configuration (ip igmp querier-timeout)
    • IGMP group join limit (ip igmp group join-limit)
  • If the MXL switch is in boot-line interface (BLI) mode:

    • You cannot switch to the CMC console and manage the switch using CMC.
    • You cannot disconnect and reconnect to CMC from the CMC console.
      NOTE: Connect to the CMC console after you exit the BLI interface or after the BLI phase of the bootup finishes.
  • After you upgrade the CPLD version on an MXL switch using the BLI, the new CPLD version is not displayed in show revision output if you power cycle the switch using the power-cycle stack-unit command. Instead, power cycle the MXL switch using the CMC interface.

  • The MXL switch crashes and reboots when an FRU read operation fails.

  • When FRRP is enabled in a VLT domain, no flavor of Spanning tree should concurrently be enabled on the nodes of that specific VLT domain. In essence FRRP and xSTP should not co-exist in a VLT environment.

  • While deploying the system in the normal-reload mode in BMP configuration, use the ip ssh server enable command at the beginning of the startup configuration if the write memory command is used at the end of the configuration.

Changes to Default Behavior and CLI Syntax
Following default behavior and CLI syntax changes occurred during the Dell Networking OS release:

  • To enhance security, the default RSA key size has been changed to 2048 bits from 1024 bits from 9.14.1.10 onwards.

Documentation Corrections
This section describes the errors identified in the current release of the Dell Networking OS.
None.

Deferred Issues
Issues that appear in this section were reported in Dell Networking OS version 9.14(1.0) as open, but have since been deferred. Deferred issues are those that are found to be invalid, not reproducible, or not scheduled for resolution.
Deferred issues are reported using the following definitions.

Category Description
PR# Problem Report number that identifies the issue.
Severity S1 — Crash: A software crash occurs in the kernel or a running process that requires a restart of AFM, the router, switch, or process.
S2 — Critical: An issue that renders the system or a major feature unusable, which can have a pervasive impact on the system or network, and for which there is no work-around acceptable to the customer.
S3 — Major: An issue that affects the functionality of a major feature or negatively effects the network for which there exists a work-around that is acceptable to the customer.
S4 — Minor: A cosmetic issue or an issue in a minor feature with little or no network impact for which there might be a work-around.
Synopsis Synopsis is the title or short description of the issue.
Release Notes Release Notes description contains more detailed information about the issue.
Work around Work around describes a mechanism for circumventing, avoiding, or recovering from the issue. It might not be a permanent solution.
Issues listed in the “Fixed Issues” section should not be present, and the work-around is unnecessary, as the version of code for which this release note is documented has resolved the issue.

Deferred MXL 9.14(1.0) Software Issues
Issues that appear in this section were reported in Dell Networking OS version 9.14(1.0) as open, but have since been deferred. Deferred caveats are those that are found to be invalid, not reproducible, or not scheduled for resolution.

The following issues have been deferred in the Dell Networking OS version 9.14(1.0):
None

Fixed Issues
Fixed issues are reported using the following definitions.

Category Description
PR# Problem Report number that identifies the issue.
Severity S1 — Crash: A software crash occurs in the kernel or a running process that requires a restart of AFM, the router, switch, or process.
S2 — Critical: An issue that renders the system or a major feature unusable, which can have a pervasive impact on the system or network, and for which there is no work-around acceptable to the customer.
S3 — Major: An issue that affects the functionality of a major feature or negatively effects the network for which there exists a work-around that is acceptable to the customer.
S4 — Minor: A cosmetic issue or an issue in a minor feature with little or no network impact for which there might be a work-around.
Synopsis Synopsis is the title or short description of the issue.
Release Notes Release Notes description contains more detailed information about the issue.
Work around Work around describes a mechanism for circumventing, avoiding, or recovering from the issue. It might not be a permanent solution.
The work-around is unnecessary, as the version of code for which this release note is documented has resolved the issue.

Fixed MXL 9.14(1.12) Software Issues

NOTE: Dell Networking OS 9.14(1.12) includes fixes for issues addressed in previous 9.14 releases. Refer to the respective release notes documentation for the list of issues fixed in earlier 9.14 releases.

The following issues are fixed in Dell Networking OS version 9.14(1.12):
PR#169841
Severity: Sev 2
Synopsis: In certain scenarios, an MSDP learnt PIM TIB entry stays in
registering state indefinitely.
Release Notes: In certain scenarios, an MSDP learnt PIM TIB entry stays in
registering state indefinitely.
Workaround: Set the affected node as a non-designated router in the RPF neighbor
interface.
PR#170240
Severity: Sev 2
Synopsis: AAA accounting request displays an incorrect calling station-id.
Release Notes: AAA accounting request displays an incorrect calling station- id.
Workaround: None
PR#170255
Severity: Sev 2
Synopsis: The switch encounters an exception when saving the configuration on
VLT pair switches simultaneously.
Release Notes: The switch encounters an exception when saving the configuration on
VLT pair switches simultaneously.
Workaround: None
PR#170301
Severity: Sev 3
Synopsis: The BN_mod_sqrt() function, which computes a modular square
root, contains a bug that can cause it to loop forever for non-prime
moduli(CVE-2022-0778)
Release Notes: The BN_mod_sqrt() function, which computes a modular square
root, contains a bug that can cause it to loop forever for non-prime
moduli(CVE-2022-0778)
Workaround: None

Known Issues
Known issues are reported using the following definitions.

Category Description

  • PR#
    Problem Report number that identifies the issue.
    Severity S1 — Crash: A software crash occurs in the kernel or a running process that requires a restart of AFM, the router, switch, or process.
    S2 — Critical: An issue that renders the system or a major feature unusable, which can have a pervasive impact on the system or network, and for which there is no work-around acceptable to the customer.
    S3 — Major: An issue that affects the functionality of a major feature or negatively effects the network for which there exists a work-around that is acceptable to the customer.
    S4 — Minor: A cosmetic issue or an issue in a minor feature with little or no network impact for which there might be a work-around.

  • Synopsis
    Synopsis is the title or short description of the issue.

  • Release Notes
    Release Notes description contains more detailed information about the issue.

  • Work around
    Work around describes a mechanism for circumventing, avoiding, or recovering from the issue. It might not be a permanent solution. Issues listed in the “Fixed Issues” section should not be present, and the work-around is unnecessary, as the version of code for which this release note is documented has resolved the issue.

Known MXL 9.14(1.12) Software Issues
The following issues are open in Dell Networking OS version 9.14(1.12):
None

MXL Upgrade Procedures: Overview
To upgrade the Dell Networking OS to the latest version on a MXL switch, complete these steps:

  • Upgrading the MXL Dell Networking OS Image and Boot Code
  • Upgrading the CPLD
  • VLT Upgrade Procedure

Upgrading the Dell Networking OS Image, Boot Flash and Boot Selector Images

NOTE: Upgrading to Dell Networking OS version 9.14(1.12) from a version prior to Dell Networking OS version 8.3.16.4 using TFTP is a two-step process:

  1. Upgrade the unit with Dell Networking OS version prior to 8.3.16.4 to Dell Networking OS 8.3.16.4 to support copy of files greater than 32MB using TFTP.
  2. Upgrade the unit to Dell Networking OS version 9.14(1.12)
    Each MXL 10/40GbE Switch IO module must be upgraded individually to a new Dell Networking OS version.

NOTE: If you are using Bare Metal Provisioning (BMP), refer to the Bare Metal Provisioning chapter in the Dell Networking OS Configuration Guide.

Manual Upgrade Procedure
To upgrade your MXL 10/40GbE switch IO module, follow these steps:

  1. Dell Technologies recommends that you back up your startup configuration and any important files and directories to an external media prior to upgrading the system.

  2. Upgrade the Dell Networking OS in flash partition A: or B:
    upgrade system [flash: | ftp: | scp: | tftp:] [A: | B:] EXEC Privilege
    Dell# upgrade system ftp: A:
    Address or name of remote host []: 10.16.127.35 Source file name []: FTOS- XL-9.14.1.12.bin User name to login remote host: ftpuser Password to login remote host: !!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!
    Erasing IOM Primary Image, please wait
    .!…………………………………………………………………………
    44875621 bytes successfully copied
    System image upgrade completed successfully. Dell#

  3. In case of a stack setup, upgrade the Dell Networking OS for the stacked units. upgrade system stack-unit [0 – 5 | all] [A: | B:] EXEC Privilege
    If A: is specified in the command, the Dell Networking OS version present in Management unit’s A: partition will be pushed to the stack units. If B: is specified in the command, the Management unit’s B: will be pushed to the stack units. Upgrade of stack units can be done on individual units by specifying the unit id [0-5] or on all units by using all in the command.
    Dell# upgrade system stack-unit all A: !!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!! !!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!! !!!
    Image upgrade to all
    Dell#

  4. Verify the Dell Networking OS has been upgraded correctly in the upgraded flash partition
    show boot system stack-unit [0-5 | all] EXEC PRIVILEGE
    The Dell Networking OS versions present in A: and B: can be viewed for individual units by specifying the stack unit id [0-5] in the command or for all the stack units by specifying all in the command.
    Dell# show boot system stack-unit all
    Current system image information in the system:

    =============================================================
    Type Boot Type A B
    ————————————————————-
    Stack-unit 0 FLASH BOOT 9.14(1.12)[boot] 9.14(1.10)
    Stack-unit 1 FLASH BOOT 9.14(1.12)[boot] 9.14(1.10)
    Stack-unit 2 is not present.
    Stack-unit 3 is not present.
    Stack-unit 4 is not present.
    Stack-unit 5 is not present.
    Dell#

  5. Upgrade the MXL 10/40 GbE switch Boot Flash and Boot Selector images.
    upgrade boot [all | bootflash-image | bootselector-image] stack-unit [0-5 | all] [booted | flash: | ftp: | scp: | tftp: | usbflash:] [A: | B:] EXEC Privilege
    Dell Networking OS version 9.14(1.12) requires MXL 10/40 GbE Boot Flash image version 4.0.1.3 and Boot Selector image version 4.0.0.2. If any higher versions of Boot Flash or Boot Selector versions are present in the unit, do not upgrade
    the Boot Flash and Boot Selector images respectively. The Boot Flash and Boot Selector images can be upgraded at the
    same time by specifying all in the command. These can be upgraded separately by selecting bootflash-image or bootselector-image respectively. The Boot Flash and Boot Selector images can be upgraded for individual stack units by specifying the particular stack unit ID from the range [0-5] in the command. These can be upgraded to all the stack units together by selecting all option instead of the stack unit ID. The Boot Flash and Boot Selector images can be saved in two partitions A: and B: and the user can select the partition to be upgraded by specifying A: or B: in the command.
    Dell#upgrade boot all stack-unit all ftp: A: Address or name of remote host []: 10.16.127.35
    Destination file name []: FTOS-XL-9.14.1.12.bin
    User name to login remote host: ftpuser
    Password to login remote host:
    !!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!
    Current Boot information in the system:

    Card BootFlash Current Version New Version
    ———————————————————–
    Unit0 Boot Flash 4.0.1.3 4.0.1.3
    Unit1 Boot Flash 4.0.1.3 4.0.1.3


    Warning – Upgrading boot flash is inherently risky and should only
    be attempted when necessary. A failure at this upgrade may cause
    a board RMA. Proceed with caution !


    Proceed Boot Flash image for all units [yes/no]: yes
    !!!!!!!!!!!!!!!!
    Erasing IOM Primary Bootflash Image, please wait
    .!.!.!.!.!.!.!..!…………………..
    Bootflash image upgrade for all completed successfully.
    !!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!
    Current Boot information in the system:

    Card BootSelector Current Version New Version
    ———————————————————–
    Unit0 Boot Selector 4.0.0.2 4.0.0.2
    Unit1 Boot Selector 4.0.0.2 4.0.0.2


    Warning – Upgrading boot selectors is inherently risky and should
    only be attempted when necessary. A failure at this upgrade may
    cause a board RMA. Proceed with caution !


    Proceed Boot Selector image for all units [yes/no]: yes
    !!!
    Erasing IOM Boot Selector Image, please wait
    .!!.!..!.!..!.!…….
    Bootselector image upgrade for all completed successfully.
    Dell#

  6. Change the Primary Boot Parameter of the MXL 10/40 GbE switch to the upgraded partition A: or B:
    boot system stack-unit [0-5 | all] primary [system A: | system B: | tftp://URL] CONFIGURATION

  7. Save the configuration so that the configuration will be retained after a reload using write memory command. write [memory] EXEC Privilege
    In case of a stack setup, the configuration will be saved in the Management as well as the Standby units.
    Dell#write memory
    ynchronizing data to peer Stack-unit
    !!!!!!!!
    Dell#

  8. Reload the unit.
    reload EXEC Privilege
    Dell#reload
    Proceed with reload [confirm yes/no]: yes
    Mar 24 21:32:27: %STKUNIT0-M:CP %CHMGR-5-RELOAD: User request to reload the chassis syncing disks… done

  9. Verify the MXL 10/40 GbE switch has been upgraded to the Dell Networking OS version 9.14(1.12).
    show version
    EXEC Privilege
    Dell#show version
    Dell EMC Real Time Operating System Software
    Dell EMC Operating System Version: 2.0
    Dell EMC Application Software Version: 9.14(1.12)
    Copyright (c) 1999-2021 by Dell Inc. All Rights Reserved.
    Build Time: Thu Mar 24 06:07:13 2022
    Build Path: /build/build01/SW/SRC
    Dell EMC Networking OS uptime is 4 day(s), 19 hour(s), 32 minute(s)
    System image file is “system://A”
    System Type: MXL-10/40GbE
    Control Processor: MIPS RMI XLP with 2 Gbytes (2147483648 bytes) of memory, core(s) 1.
    256M bytes of boot flash memory.
    1 34-port GE/TE/FG (XL)
    48 Ten GigabitEthernet/IEEE 802.3 interface(s)

  10. Verify the MXL 10/40 GbE switch has been upgraded to the latest Boot Flash and Boot Selector versions.
    show system stack-unit [0-5] EXEC Privilege
    Dell#show system stack-unit 0
    — Unit 0 —
    Unit Type : Management Unit
    Status : online
    Next Boot : online
    Required Type : MXL-10/40GbE – 34-port GE/TE/FG (XL)
    Current Type : MXL-10/40GbE – 34-port GE/TE/FG (XL)
    Master priority : 0
    Hardware Rev : 1
    Num Ports : 56
    Up Time : 2 min, 56 sec
    Dell Networking OS Version : 9.14(1.12)
    Jumbo Capable : yes
    POE Capable : no
    FIPS Mode : disabled
    Boot Flash : A: 4.0.1.3 [booted] B: 4.0.1.3
    Boot Selector : 4.0.0.2

Upgrading the CPLD

The MXL system with Dell Networking OS version 9.14(1.12) requires CPLD image 6.

Verify that a CPLD upgrade is required
Use the following command to identify the CPLD version:

Dell# show revision
— Stack unit 1 —
IOM SYSTEM CPLD : 6 Dell#show system stack-unit 1
— Unit 1 —
Unit Type : Management Unit
Status : online
Next Boot : online
Required Type : MXL-10/40GbE – 34-port GE/TE/FG (XL)
Current Type : MXL-10/40GbE – 34-port GE/TE/FG (XL)
Master priority : 0
Hardware Rev : X01
Num Ports : 56
Up Time : 6 min, 53 sec
Dell Networking OS Version : 9.14(1.12)
Jumbo Capable : yes
POE Capable : no
FIPS Mode : disabled
Boot Flash : A: 4.0.1.3 B: 4.0.1.3 [booted] Boot Selector : 4.0.0.2
Memory Size : 2147483648 bytes
Temperature : 65C
Voltage : ok
Switch Power : GOOD
Product Name : Dell EMC MXL 10/40GbE
Mfg By : Dell EMC
Mfg Date :
Serial Number :
Part Number : 0NVH81X01
Piece Part ID : N/A
PPID Revision : N/A
Service Tag : N/A
Expr Svc Code : N/A
Chassis Svce Tag : 29MFHY1
Fabric Id : B1
Asset tag :
PSOC FW Rev : 0xb
ICT Test Date : 0-0-0
ICT Test Info : 0x0
Max Power Req : 31488
Fabric Type : 0x3
Fabric Maj Ver : 0x1
Fabric Min Ver : 0x0
SW Manageability : 0x4
HW Manageability : 0x1
Max Boot Time : 6 minutes
Link Tuning : unsupported
Auto Reboot : enabled
Burned In MAC : 00:01:e8:01:02:05

Use the following command to view CPLD version that is associated with the Dell Networking OS image:

Dell#show os-version
RELEASE IMAGE INFORMATION :
———————————————————————
Platform Version Size ReleaseTime
IOM-Series:XL 9.14(1.12) 45570717 Mar 24 2022 17:21:29
TARGET IMAGE INFORMATION :
———————————————————————
Type Version Target checksum
runtime 9.14(1.12) Control Processor passed
BOOT IMAGE INFORMATION :
———————————————————————
Type Version Target checksum
boot flash 4.0.1.3 Control Processor passed
BOOTSEL IMAGE INFORMATION :
———————————————————————
Type Version Target checksum
boot selector 4.0.0.2 Control Processor passed
CPLD IMAGE INFORMATION :
———————————————————————
Card CPLD Name Version
Stack-unit 1 IOM SYSTEM CPLD 6
Dell#

Upgrading the CPLD Image

  • NOTE: The upgrade fpga-image stack-unit 0 booted command is hidden when using the ? feature in the CLI. However, it is a supported command and will be accepted when entered as documented.

To upgrade the CPLD image on an MXL 10/40GbE Switch IO module:

  1. Upgrade the CPLD image.
    upgrade fpga-image stack-unit [0-5] booted EXEC Privilege
    Dell#upgrade fpga-image stack-unit 0 booted
    Current FPGA information in the system:

    Card FPGA Name Current Version New Version ————————————————————————
    Unit0 IOM SYSTEM CPLD 6 6


    Warning – Upgrading FPGA is inherently risky and should only be attempted when necessary. A failure at this upgrade may cause a board RMA. Proceed with caution ! *



    Warning – Upgrading FPGA is inherently risky and should only be attempted when necessary. A failure at this upgrade may cause a board RMA. Proceed with caution ! *


  2. Power cycle the switch (IO module) using the CMC interface or remove and re-insert the switch (OIR) from the chassis so that the CPLD upgrade takes effect.
    NOTE: The powercycle stack-unit 0 command does not load the latest CPLD version.

  3. Check whether the CPLD has been upgraded to the latest version.
    show revision EXEC PRIVILEGE
    Dell# show revision — Stack unit 0 —
    IOM SYSTEM CPLD : 6

VLT Upgrade Procedure
To upgrade the Dell Networking OS in a VLT setup from version 9.2(0.0) to the latest version, upgrade the Dell Networking OS to version 9.3(0.0) first. If you are running the Dell Networking OS version 9.3(0.0) or later, you can upgrade the Dell Networking OS to the latest version.

To upgrade the Dell Networking OS, on systems running VLT, perform the following steps:

  1. Upgrade the system-flash partition A or B with the new image on both VLT peers.
    On both the VLT peers, set
    Primary boot parameter to boot the system from upgraded system flash partition [A or B]. You can enter one of the following options: flash — Copies from flash file system (flash://filepath). ftp — Copies from remote file system (ftp://userid:password@hostip//filepath). scp — Copies from remote file system (scp://userid:password@hostip//filepath). tftp— Copies from remote file system (tftp://hostip/filepath).
    upgrade system [flash: | ftp: | scp: | tftp: | usbflash:] [A: | B:] EXEC Privilege

  2. Reload or power-cycle one of the VLT peers (For Example, Peer 2).
    reload or power cycle

  3. Wait for Peer 2 to come up; VLT adjacency will be established. (Peer 2 – new image and Peer 1 – old image).

  4. Wait for the Peer 2 to bring up all VLT LAG ports. Use the command show vlt detail to confirm all VLT ports in the local chassis are active.
    show vlt detail
    EXEC Privilege

  5. Following upgrade, use the write memory command to save the running-config to memory.
    write memory
    EXEC Privilege

  6. Ensure both the nodes are now forwarding traffic.

  7. When all VLT ports are active on the Peer 2, repeat steps 2 through 5 for the Peer 1.

Support Resources
The following support resources are available for the MXL system.

Documentation Resources
This document contains operational information specific to the MXL system.
For information about using the MXL, refer to the following documents at http://www.dell.com/support:

  • Installing the MXL System
  • Quick Start Guide
  • Dell Networking Command Line Reference Guide for the MXL System
  • Dell Networking Configuration Guide for the MXL System

For more information about hardware features and capabilities, refer to the Dell Networking website at https://www.dellemc.com/networking.
For more information about the open network installation environment (ONIE)-compatible third-party operating system, refer to http://onie.org.

Issues
Issues are unexpected or incorrect behavior and are listed in order of Problem Report (PR) number within the appropriate sections.

Finding Documentation
This document contains operational information specific to the MXL system.

Contacting Dell Technologies

NOTE: If you do not have an active Internet connection, you can find contact information on your purchase invoice, packing slip, bill, or Dell Technologies product catalog.
Dell Technologies provides several online and telephone-based support and service options. Availability varies by country and product, and some services may not be available in your area. To contact Dell Technologies for sales, technical support, or customer service issues:

Go to www.dell.com/support.

Notes, cautions, and warnings

  • NOTE: A NOTE indicates important information that helps you make better use of your product.
  • CAUTION: A CAUTION indicates either potential damage to hardware or loss of data and tells you how to avoid the problem.
  • WARNING: A WARNING indicates a potential for property damage, personal injury, or death.

© 2022 Dell Inc. or its subsidiaries. All rights reserved. Dell Technologies, Dell, and other trademarks are trademarks of Dell Inc. or its subsidiaries. Other trademarks may be trademarks of their respective owners.