PREPARING THE DOOR

  1. Draw a horizontal line on edge of the door and on inside at the desired height of handle above floor.
  2. Draw a vertical centre line on door edge.
  3. Draw a vertical line on inside at the proper backseat to align.
  4. Mark ONLY top and bottom holes of mortise cavity (A). Place lock face against door edge. Trace outline of faceplate as guide for faceplate routing.
  5. Mortise door for lock body and faceplate.
  6. Mark holes in the lateral face of the door for turn piece (B) and handles (C and D). Mark the holes for the corresponding electronic escutcheon fixings.

NOTE: See draw 225696 for reader fixing holes depending on Element model. INSTALLING THE LOCK BODY

  1. Insert wires through hole.
  2. Insert the lock into the cavity.
  3. Mark & drill mortise lock’s fixing holes.
    Fasten front plate with screws to hold lock in place.

INSTALLING THE STRIKE

  1. Refer to latch to determine strike location on jamb.
  2. Using strike as template, mark and chisel recess.
  3. Drill screw holes. Place dust box and strike and fasten with the supplied screws.
  4. Please check if:
    – Deadbolt and latch fit the cavities of the strike without touching it.
    – Gap between door and jamb is between 2-4 mm.
    – Strike flap should protrude at least 2mm, if it does not, please ask your distributor for the availability of special strikes.

SALTO LE7S05 Asymmetric Mortise Lock Installation Guide - Lock
installation

Strike installation

SALTO LE7S05 Asymmetric Mortise Lock Installation Guide - Strike
installation

⚠ * For the auxiliary latch to operate correctly, it is absolutely essential to install the dust box.

Maintenance

All locks come from the factory pre-lubricated with grease. We recommend, however, continued periodic lubrication of moving parts like, latch, auxiliary latch and deadbolt, with a non-silicon based commercial quality grease with a suitable operational temperature range for the environment in which the product is installed (every 20.000 cycles or once a year). This can prolong the life o the lockset by reducing excessive wear. If the lockset is used in a harsh environment, lubrication should be applied more frequently.

  • The safety features of this product are essential to its compliance with EN 179. No modification of any kind, other than those described in these instructions, is permitted.
  • This device is intended for use on single inward/outward opening fire and non-fire rated escape route doors.
  • This product is to be used on doors with maximum dimensions of 1300mm wide x 2500mm height and weighing no more than 200kg (440lb).
  • Maximum door distortion of 5mm allowed to ensure safe exit at all times.
  • Maximum of 1000N abuse force achieved under the abuse test.
  • Category of Projection = Category 2 Less than 100mm.
  • For use on timber doors.
  • Suitable for use on fire doors.
  • Fire resistance 30mins, 60mins and 90mins timber doors.
  • For fire certificates, see www.saltosystems.com
  • This product meets EN 179 only when combined with SALTO R1SUxx, R1SExx and R1SJxx roses.
  • Blocking the electronic lever handle from the outside can render the device inoperable from the inside.

All contents current at time of publication. SALTO Systems S.L. reserves the right to change availability of any item in this catalog, its design, construction, and/or materials

© 2022 SALTO Systems S.L.
225686-ED. – 16/05/2022

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

SALTO User Manuals

Related Manuals