Miele APDR027 Set Retrofit Air Flap Kit Instruction Manual

June 20, 2024
Miele

Miele APDR027 Set Retrofit Air Flap Kit

Product Information

Specifications

  • Model Number: 12616100
  • Included Parts:
    • Cordless screwdriver with chuck
    • HSS drill bit, 3 mm
    • TX 20 screwdriver
    • Electric air flap
    • Screw, M4 x 12.5

Product Usage Instructions:

Installing the Air Flap

  1. If an XCI-Box is not installed, follow the installation instructions to install and activate the XCI-Box.
  2. Attach the air flap to the vent duct of the tumble dryer using the provided M4 x 12.5 screw. Drill a 3 mm diameter hole for this purpose.
  3. Route the air flap connection cable into the XCI box and secure it with the strain relief.
  4. Connect the air flap to contacts 3.3 and 3.4 in the XCI box. Ensure that the total current carrying capacity does not exceed 4 A.
  5. Switch on the tumble dryer and switch to the supervisor level to complete the installation.

FAQ (Frequently Asked Questions)

  • Q: Why is it necessary to install an air flap in the vent ducting?
    A: Installing an air flap is essential to prevent high or low pressure in the vent ducting from causing issues with the fan impeller, which can lead to fault F218.

  • Q: How do I ensure that the total current carrying capacity does not exceed 4 A when connecting components to the XCI box?
    A: When connecting multiple components to the XCI box, make sure to check the current requirements of each component and ensure that the total current does not exceed 4 A to avoid electrical issues.

Umbau- und M

ontageanweisung
3 von 20

The “Miele Service Documentation (MSD)” service application is required when carrying out maintenance work on the appliance
The safety instructions and warnings in the Miele Service Documentation (MSD) for the corresponding model must be observed.
Work on the appliance must be carried out in accordance with the work instructions.

Air flap installation instructions

Reason: if high or low pressure in the vent ducting prevents the fan impeller from standing still, an air flap must be integrated in the vent ducting. High or low pressure in the vent ducting can trigger fault F218.

Special tool/s

No. Mat. no. Designation

  • 1 Cordless screwdriver with chuck
  • 1 HSS drill bit, 3 mm
  • 1 TX 20 screwdriver

Included parts
No. Mat. no. Designation

  • 1 Electric air flap
  • 1 Screw, M4 x 12.5

Installing the air flap

The air flap is a non-return flap with motorised opening. The air flap closes under spring load within approx. 8 seconds without power applied. The air flap must move to the open position (90° rotation angle) within approx. 8 seconds. The 8 seconds start when the dryer fan starts.

  • If there is no XCI box installed, install and commission an XCI box in accordance with the installation instructions.
  • Disconnect the tumble dryer from the power supply.
  • Place the air flap between the tumble dryer and the vent ducting. Pay attention to the specified flow direction (see sticker on the air flap).
  • Use the M4 x 12.5 screw to fasten the air flap to the vent duct of the tumble dryer. Drill a 3 mm diameter hole for this purpose.
  • Guide the air flap connection cable into the XCI box and secure it with the strain relief.
  • Connect the air flap to contacts 3.3 and 3.4 in the XCI box, see [> 4].
  • If several components are connected to the XCI box, pay attention to the maximum current carrying capacity of 4 A.
  • Switch on the tumble dryer.
  • Switch to the supervisor level.
  • For machines with Performance Plus controls (touch display): go to External applications and set the Additional fan option to On.
  • For machines with Performance controls (7-segment): set the “Additional external fan” option (see operating instructions for option number) to -01.

XCI box terminal assignment

Electronic module EZL 400

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals