SALTO BLUEnet Node Wireless BLE Gateways Installation Guide
- May 15, 2024
- SALTO
Table of Contents
SALTO BLUEnet Node Wireless BLE Gateways
Specifications
- SALTO RFnet Characteristics:
- Frequency Range: 2400-2483.5 Mhz
- Standard Indoor Radio Range: 10/15m
- Max Output Power: 5dBm
- SALTO BLUEnet Characteristics:
- Frequency Range: 2400-2483.5Mhz
- Bluetooth Low Energy Range: 5m/10m
- Max Output Power: 8dBm
- Power Supply:
- SALTO RFnet Input Voltage: 7-12V
- SALTO BLUEnet Input Voltage: -20-25V
Product Usage Instructions
Mechanical Installation
Ensure proper cable requirements are met, including the use of recommended
cables like UTP CAT5e. Install the SALTO Gateway and up to 6 External RF Nodes
per Gateway.
Electrical Installation
- Terminate the RS485 bus with a resistor at the end of the bus.
- Follow the installation example provided, ensuring proper power and data connections.
Signalling
The LED indicator on the device (green for RFnet Node, blue for BLUEnet
Node) should be illuminated to indicate proper power supply.
Operational Test
After installation, verify correct operation by ensuring the RFnet Node or
BLUEnet Node is active in SALTO’s software.
Maintenance
- Perform operational tests at least once a year as described.
- Keep the device in a safe location.
Radio Information
Environmental factors affect signal range. Install the receiver facing the
product antenna for optimal connectivity within 5m – 10m distance.
FAQ
-
Q: How often should I test the unit?
A: The unit should be tested at least once a year as described in the operational test section. -
Q: What is the recommended connectivity distance?
A: The recommended connectivity distance is between 5m to 10m for optimal performance.
Installation guide
BLUEnet Node and RFnet Node
Installation guide
The BLUEnet Node and RFnet Node are part of SALTO wireless system. They work as a bridge, with the SALTO Gateway, between SALTO’s access control software and wireless locks.
Electrical characteristic
Operation conditions
Min | Typ | Max | Unit |
---|---|---|---|
Temperature | -20 | 25 | 70 |
Humidity | 35 | 85 |
Cable requirements
RS485 Connection (AB) Generic twisted pair wire Note 1
Power Connection (Vdd) 24 AWG
Power Supply for SALTO RFnet
Min | Typ | Max | Unit |
---|
Imput Voltage 7
Current consumption| 12| 28
45Note 2| V
mA
Power Supply for BLUENET
Min | Typ | Max | Unit |
---|---|---|---|
Imput voltage | -20 | 25 | 70 |
Current consumption RFNode | 45 Note 2 | ||
Current consumption RFNet | 75 Note 2 |
SALTO RFnet Characteristics
- Frequency Range 2400-2483.5 Mhz
- Standard IEEE 802.15.4
- Indoor Radio Range 10/15m
Max output power 5dBm
SALTO BLUEnet Characteristics
- Frequency Range 2400-2483.5Mhz
- RF Standard Bluetooth Low Energy
- Indoor Radio Range 5m/10m
Max output power 8dBm
Mechanical installation
Electrical installation
RS485 bus termination resistor is needed (ON position) when the node is located at the end of the bus.
Installation example
Signaling
The green (RFnet Node) or blue (BLUEnet Node) LED of the device indicates that
the device is properly powered.
Operational test
- Once the product is installed, follow these steps to check the correct operation:
- When SALTO Gateway and locks are installed, check that the RFnet Node or blueNET Node is active in SALTO’s software.
Maintenance
The unit should be tested at least once a year as described in “Operational test”. Keep the device in a safe place!
Radio information
- The environment has a direct impact on the range radiation (metal, concrete walls…)
- The receiver device must be located facing the product antenna. Please check your product’s device antenna position. Recommended connectivity distance: 5m – 10m