SALTO CU4EB8 Expansion Board Installation Guide
- May 15, 2024
- SALTO
Table of Contents
SALTO CU4EB8 Expansion Board
Specifications
- Model: CU4EB8
- Power Input: 12V DC – 1.5A (MAX)
- Weight:
- CU4EB8T00: 226g
- CU4EB8G00: 600g
Product Usage Instructions
Mechanical Installation:
Dimensions (in mm):
- CU4EB8T: 131 (H) x 121 (W) x 104 (D)
- CU4EB8G: 44 (H) x 43 (W) x 10 (D)
Electrical Installation:
Power Connections:
- 12VDC Input: Connect to power source
- 12VDC Output: Use + and – terminals for output
Relay Connections:
Ensure max load restrictions (2A-30VDC) are adhered to. Use a varistor for
inductive loads.
Inputs:
Identify and connect bridge cables based on input configuration.
Online/Offline Configuration:
Use the jumper to configure the unit for offline operation.
Dip Switch Settings:
- Offline Mode: Assign output numbers to relays based on the provided table.
- Tamper Input: Connect tamper signal from external devices.
FAQ:
-
Q: What is the maximum power consumption of the CU4EB8?
A: The maximum consumption is 1.5A when using the output power port. If not using the output port, the maximum consumption is 500mA. -
Q: What type of cable is recommended for BUS485 Inputs?
A: Twisted pair cable with AWG24 specification is recommended for BUS485 Inputs. -
Q: What is the rated load for the output relays?
A: The output relays support a rated load of 2A-30Vdc.
Dimension
The CU4EB8 expansion board unit provides multi-relay switchable output management to external systems such as lift floor level access, multi-shutter and barrier systems, machine switching and more.
Installation guide
Mechanical Installation
- CU4EB8T – CU4EB8G
Note:
Follow the same connection model, using the CU tamper input, when using a
third-party electric box equipped with a tamper opening detection.
Note: To override the wall tamper, place the jumper in the OFF position.
- Physical tamper switch to be operated by external electric box models.
- BUS RS485 Terminal Resistor must be in the ON position when the CU is connected at the end of the BUS.
- Power Input.
- Power Output: This output is directly connected to the power input port protected by a 1A fuse.
- BUS485.
- Relay Connections: Please take into account the max. load restrictions(2A-30VDC). Use the provided varistor if an inductive load is used.
- Inputs: The Installer must identify the bridge cable needed depending on the input configuration.
- Online/Offline jumper: Configure the unit to work as an offline device. Dip switch:
- Offline Mode->See the output table to assign the output number to a relay.
- Tamper input to connect the tamper signal from the SALTO electric box or other compatible devices.
Factory configuration (offline mode)
IN1| Disable
IN2| Disable
IN3| Disable
IN4| Disable
RL1| Output number 1
RL2| Output number 2
RL3| Output number 3
RL4| Output number 4
RL5| Output number 5
RL6| Output number 6
RL7| Output number 7
RL8| Output number 8
Electrical characteristics
Operation conditions
Min
| Typ| Max|
Unit
---|---|---|---
Temperature| 0| 25| 60| ºC
Humidity| 35| | 85|
Power
Min
| Nom.|
Max Unit
---|---|---
InputVoltage
Current consumption
| 12| V
1500Note1 mA
Output port current Note2| | 1 A
Input
- Electrical characteristics 5v Note3
- Configuration ViaSoftware Note4
Cable recommendation
BUS485 Twisted pair AWG24
Inputs AWG24
Output relays
Rated load(resistive) 2A-30Vdc
- Note 1: This is the maximum consumption of the CU4EB8 using the output power port (1A max). If the power output port is not used, the maximum consumption is 500mA
- Note 2: Same voltage as the input.
- Note 3: 1K pull-up resistor.
- Note 4: See the software User Manual.
Installation example:
Offline configuration
- The unit must be connected to a CU4200 in stand-alone mode (dip-switch in the CU4200 -> 0000).
- In offline mode, the inputs are disabled.
- The dip-switch configures the number of the output in the different relays as the following table.
- To assign the output number to a specific user see SALTO ProAccess SPACE User Manual.
TABLE 1
Online Configuration
- Connect all the devices through the BUS485 and power the CU4EB8.
- Create and set up the CU4EB8 on the Software (Consult the SALTO ProAccess SPACE user manual).
- Asign the CU4EB8 to the node it is connected.
- Define the address in the BUS485.
- The relay-out set-up has to be done through the SALTO ProAccess SPACE software.
- Put the Resistor in ONLINE mode.
- The CU4EB8 dip-switch setting is used to give each device on the BUS485 a unique address.
- Ensure that the address in the software is the same as the one you put on the hardware. (See Table 2).
- Both ends of the BUS485 must have the RS485BUS termination resistor in the ON position, intermediate devices need to have the resistor in the OFF position.
Supervised input connections:
By default all inputs are disabled. They can be configured through the
software. If the inputs are supervised, the resistance values R1 and R2 are
defined in the software: 1k (recommended), 1k5,2k2,3k3,4k7,6k8,10k.
TABLE 2
Set up example:
Same configuration at SALTOs ProAccess SPACE Software
Signalling:
The LEDs in the top layer of the CU4EB8 show the state of the system:
| LED name|
Description
---|---|---
ON
| GREEN ON: the unit is powered correctly
BLINKING RED: the unit is not powered properly (check power supply)
OFF: not powered
TAMPER| ON: tamper alarm active
OFF: tamper alarm not active
IN1-IN4| ON: active input (depends on the input type configured in the
software)
OFF: inactive input (depends on the input type configured in the software)
RL1-RL8| ON: the relay is activated (NO is connected with C).
OFF: the relay is inactive (NC is connected with C).