HUMIDIFIER VT-2334 W
Insufficient room humidity negatively affects humans’ and pets’ health as well as plants and furniture. The recommended comfortable room humidity level is from 40% to 60%. The VT-2334 W humidifier allows you to improve the air quality in the room.
DESCRIPTION
- Lid with a mist release opening
- Water tank
- Water inlet
- Water tank lid
- «Sprayer»
- On/no water indication
- ON/OFF knob/mist release intensity control
- Body
ATTENTION!
For additional protection it is reasonable to install a residual current device (RCD) with nominal operation current not exceeding 30 mA. To install RCD, contact a specialist.
SAFETY MEASURES
Before using the electrical unit, read this instruction manual carefully and
keep it for future reference. Use the unit for its intended purpose only, as
specified in this manual. Mishandling of the unit
may lead to its breakage and cause harm to the user or damage to his/her
property.
- Before switching the unit on, make sure that voltage of the mains corresponds to unit operating voltage.
- Place the unit on a flat, moisture-resistant surface. The distance to the walls, other furniture and interior objects should be at least 30 cm.
- Do not place the unit on carpet surfaces with high pile.
- Do not place the air humidifier in places exposed to direct sunlight, high temperatures, near computers or other sensitive electronic appliances.
- Do not use the unit outdoors.
- Use the supplied removable parts only.
- Do not operate the unit without water; switch the unit off when the water tank is empty.
- Do not use soda or dirty water or any perfume additives.
- Water temperature should not exceed +40°С.
- Do not switch the unit on if the water tank is not installed.
- Unplug the unit before removing the water tank.
- Do not cover the unit.
- Do not cover the openings on the unit body and avoid getting of foreign objects inside them.
- Do not immerse the unit body, the power plug or the power cord into water or any other liquids.
- Do not move or tilt the unit during the operation and do not remove the water tank.
- Always unplug the unit and pour out water from the water tank and the process chamber before cleaning or if you do not use the air humidifier.
- Before moving the unit to another place, unplug it and pour out water from the water tank and the process chamber. When carrying the unit, hold it by the body with both hands.
- Do not touch the power plug with wet hands.
- Clean the unit regularly.
- Do not allow children to touch the unit body and the power cord during operation.
- This unit is not intended for usage by children.
- The unit is not intended for usage by physically or mentally disabled persons (including children) or by persons lacking experience or knowledge if they are not under supervision of a person who is responsible for their safety or if they are not instructed by this person on the usage of the unit.
- Do not leave children unattended to prevent using the unit as a toy.
- For children safety reasons do not leave polyethylene bags, used as packaging, unattended. Attention! Do not allow children to play with polyethylene bags or packaging film. Danger of suffocation!
- Never pull the power cord when disconnecting the unit from the mains; take the power plug and carefully pull it out of the mains socket.
- Never use the unit if the power cord or the power plug is damaged, if the unit works improperly or after it was dropped.
- Do not attempt to repair the unit. Do not disassemble the unit by yourself, if any malfunction is detected or after it was dropped, unplug the unit and apply to any authorized service center from the contact address list given in the warranty certificate and on the website www.vitek.ru.
- Transport the unit in the original package only.
- For environment protection do not discard the unit with usual household waste after its service life expiration; apply to a specialized center for further recycling.
- Keep the unit out of reach of children and disabled persons.
THE UNIT IS INTENDED FOR HOUSEHOLD USAGE ONLY
BEFORE THE FIRST USE
After unit transportation or storage under cold (winter) conditions, it is
necessary to keep it for at least three hours at room temperature.
There may be water spots in the air humidifier, this is normal, as the unit
has undergone factory quality control.
– Unpack the unit, remove any stickers and ackage materials that can prevent
unit operation. Check the unit for damages. In case of damages do not switch
the unit on.
– Before plugging the unit in make sure that your home mains voltage
corresponds to the unit operating voltage.
Notes:
– Use the air humidifier at the room temperature from +10° С to +40°С, and
relative humidity less than 80%.
– Water temperature should not exceed +40°С
AIR HUMIDIFIER OPERATION
-
Remove the lid with mist release openings (1) from the tank (2).
-
Remove the tank (2) from the unit body (8).
-
Turn the tank (2) over, take the lid (4) off by turning it counterclockwise.
-
Fill the tank (2) with the required amount of water, insert the lid (4) in the water inlet (3) and turn it clockwise.
-
Place the filled water tank (2) on the unit body (8).
-
Insert the power plug into the mains socket.
-
Switch the air humidifier on, turning the knob (7) clockwise, the ON indicator (6) will light up.
-
Set the mist release intensity by turning the knob (7).
-
If the water tank (2) is empty, the indicator (6) will light up red.
-
Switch the air humidifier off, turning the knob (7) counterclockwise as far as it will go, the indicator (6) will go out. Unplug the unit. Fill the tank (2) with water, install it to its place and
switch the unit on. -
After finishing the operation, switch the air humidifier off, turning the knob (7) counterclockwise until bumping, the indicator (6) will go out; after that remove the power plug from the socket.
Note:
– the continuous operation time of this humidifier is 8 hours.
– if the humidifier is switched off and there is still some water in the tank,
turn the knob (7) to the left until bumping and switch the humidifier on
again, turning the knob (7) clockwise and setting the necessary mist release
intensity.
CLEANING AND CARE
WARNING! Always switch the air humidifier off and unplug it before maintenance works or cleaning.
- Hard water causes the appearance of mineral scale on the sprayer (5), on the inner parts of the body and in the water tank; that leads to improper operation of the air humidifier and the appearance of white deposits on objects of the interior.
- To avoid this, it is necessary to clean the sprayer (5) weekly and to change water in the tank (2) as often as possible.
- If you are not going to use the humidifier for a long time, pour out water from the tank (2) and the operating chamber of the sprayer (5), wash the water tank (2), wash and clean the operating chamber of the sprayer (5) and the sprayer (5) itself, dry the unit thoroughly and take it away for storage.
Weekly care
-
Once a week wash the water tank (2) and the process chamber of the «sprayer» (5) thoroughly with neutral detergent solution.
-
Then rinse them with water carefully.
-
Add 5-10 drops of the detergent on the sprayer (5), wait for about 2-5 minutes. Remove the deposits from the sprayer (5) surface with a brush.
Note: As a cleaning agent for the sprayer (5) you can use scale removers for kettles. -
Clean the air humidifier body (8) with a soft slightly damp cloth, and then wipe it dry.
-
Do not immerse the air humidifier body (8), the power cord and the power plug into water or other liquids. Provide that no liquid gets inside the air humidifier body (8).
-
Do not use solvents or abrasives to clean the surface of the body (8) and the water tank (2).
STORAGE
- If you are not going to use the unit for a long time and want to take it away for storage, make sure that all its parts are dry, including the process chamber of the sprayer (5).
- Do not store the unit with water in the tank and in the process chamber of the sprayer (5).
- Keep the air humidifier away from children in a dry cool place.
STORAGE
- If you are not going to use the unit for a long time and want to take it away for storage,
TROUBLES AND TROUBLESHOOTING
Problem | Possible causes | Troubleshooting |
---|---|---|
The ON indicator doesn‘t light up, no mist release. | No supply voltage. |
Connect the unit to the mains.
Plug another, known good appliance to the socket to make sure that the socket
works properly.
The indicator is glowing red, no mist release.| Water tank is empty.| Fill the
water tank with water.
Mist smells unpleasantly.| First use of the unit.| Unscrew the water tank lid,
pour out the water and leave the tank open for 12 hours in a cool dark place.
Dirty or stale water.| Unplug the unit, remove the water tank, pour out the
water, wash the tank and fill it with clean boiled or distilled water.
Low mist release intensity| Sprayer is dirty.| Unplug the unit and clean the
sprayer.
Foreign noise during the air humidifier operation| The unit is placed on an
uneven or unstable surface.| Unplug the unit and level the unit body or move
the air humidifier to another place.
Note:
– Non-observance of the rules for cleaning the sprayer (5) from mineral
deposits affects the air humidifier performance. In this case clean the unit.
– If the tap water used is hard, use household filters for additional water
cleaning or mix it with distilled water in proportion 1:1
DELIVERY SET
Air humidifier – 1 pc.
Removable lid with nozzle –1
pc. Removable water tank – 1 pc.
Removable water tank lid – 1 pc.
Instruction manual – 1 pc
TECHNICAL SPECIFICATIONS
Supply voltage: 220-240 V ~ 50 Hz
Power consumption: 23 W
Water tank capacity: 2.8 l
Water flow: ≥ 300 ml/h
Humidified area: up to 25 m2
The manufacturer preserves the right to change
the specifications of the units without a preliminary notification
Unit operating life is 3 years Guarantee
Details regarding guarantee conditions can be obtained from the dealer from
whom the appliance was purchased. The bill of sale or receipt
must be produced when making any claim under the terms of this guarantee.
Read More About This Manual & Download PDF:
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>