VITEK VT-TNR3280E1N Network Video Recorder User Guide
- June 1, 2024
- VITEK
Table of Contents
VITEK VT-TNR3280E1N Network Video Recorder
THIS GUIDE IS APPLICABLE FOR
VT-TNR414PN, VT-TNR818PN, VT-TNR818PFN, VT-TNR1626PN, VT-TNR1646PFN, VT-
TNR3216PFN, VT-TNR3280E1N, VT-TNV6480E1, VT-TNV6416E1, VT-TNV128E1
FEATURES
- 4 / 8 / 16 / 32 / 64 / 128 Channel Stand-alone Real-time IP Network Video Recorders
- Full 8MP Recording / 12MP Resolution (Except “PN” Models)
- 4K HDMI & VGA Video Outputs
- H.265S / H.265+ / H.265 / H.264 Video Compression
- Programmable Analytics including Face Detection (PFN Models + VT-TNR3280E1N / 6480E1, VT-TNV6416/128E1), Fisheye DeWarping through IE or App, Target Counting, License Plate Recognition, Object Removal, Line Crossing, and Area and More!
- Plug and Play & Auto configuration for many leading ONVIF compliant IP Cameras
- Internal PoE Switches (Model Dependant)
- Single / Dual 1 Gigabit LAN Port, USB Ports
- Pentaplex: Live Display / Record / Playback / Backup / Remote Access
- SATA2 / SATA3 HDD Slots / RAID on “E” models
- Applications for iOS® & Android®
- Remote Viewing over the Internet via Web Browser or LAN
- Free VMS (Video Management Software) Lite and Standard versions available [Contact your Reseller for Enterprise Version]
- Control locally via USB Mouse or with the Included IR Remote control
- 3 Year Warranty
Notes
- Please read these instruction carefully before using the product and keep this guide for further reference.
- All the examples and pictures used here are for reference only.
- The contents of this manual are subject to change without notice.
- This device should be operated only from the type of power source indicated on the label. The voltage of the power supply must be verified before use.
Packing Check
Please check the device and the accessories after getting the device. If there is damage, missing parts or defects, please contact your re-seller immediately.
Rear Panel Instruction
The interfaces of the rear panel are for reference only .
-
VT-TNR414PN Rear Panel Connections
-
VT-TNR818PN Rear Panel Connections
-
VT-TNR818PFN Rear Panel Connections
-
VT-TNR1626PN Rear Panel Connections
-
VT-TNR1646PFN Rear Connections
-
VT-TNR3216PFN Rear Connections
-
VT-TNR3280E1N Rear Connections
-
VT-TNR6480E1 Rear Connections
-
VT-TNV6416E1 / VT-TNV128E1 Rear Connections
Name| Description
---|---
DC48V| Connector for power input
PoE Ports| Po E network ports; connect to PoE IP camera s
LAN| Network port
VGA| Connect to monitor
HDMI| Connect to high definition dis play device
USB| Connect to USB storage device or USB mouse
AUDIO OUT| Audio output
AUDIO IN| Audio input
Startup & Shutdown
- Startup
1. Connect the monitor and the power.
2. The device will boot and the power indicator will display blue.
3. A wizard window will pop up.
- Shutdown
Click “Start” and then select the “Shutdown” icon. This will bring up a shutdown window. The device will shut down by clicking the “OK” button. Then disconnect the power.
System Login
You must configure the wizard when you start the NVR for the first time.
Choose the language and read the privacy statement. Then set the date, time
and zone as needed. After that, set the login password.
The default username is admin and the default password of admin is 123456. Set your own password or use the default one when you use the wizard for the first time. Enable pattern lock and click “Edit” to set the pattern lock. Then set security questions and answers. It is important for you to remember these answers, or you will not be able to reset your password. Click “Next” to continue.
Disk Settings
You can view the disk number, disk capacity of the NVR, serial number, and Read/Write status of the disk. Click “Format” to format the disk. Click “Next” to continue.
Network Configuration & Add IP Camera
-
Enter the IP address, subnet mask, gateway, etc. If using DHCP, please enable DHCP in both the NVR and the router.
-
Enter HTTP port (the default value is 80) and server port (the default port is 6036).
-
The internal ethernet port is the port which connects all the PoE ports with the NVR system. The PoE ports are available if the internal ethernet port is online; if it is offline, all the PoE ports will be unavailable.
-
Add Camera. Click “Next” to go to the following interface.
Click “Refresh” to refresh the list of online IP cameras which are in the same local network with the NVR. Click+ to add the searched camera. Click “Add All” to add all the cameras in the list. Click to delete the added camera. Click “Delete All” to delete all the added cameras.
-
Click to edit an IP camera as shown on the above left. Enter the new IP address, subnet mask, gateway, username and password of the camera. Click “OK” to save the settings.
Click to edit the added camera as shown on the above right. Enter the new camera name, IP address, port, username and the password of the camera. You can click “Test” to test the effectiveness of the input information. Click “OK” to save the settings. You can change the IP camera name only when the added camera is online. Click “Next” to continue.
Record Settings
There are two recording modes: auto and manual.
Auto Mode: Select auto mode in the interface as shown below and then click
“Next” to save the settings. Click “Advanced” to self-define a recording mode.
Manual Mode: Set the “Sensor Record”, “Motion Record”, “Analytics Record” and “Schedule Record” of each camera. Please enable recording as needed. Click “Next” to continue.
NAT
You can enable the NAT function in the interface or set it in the network configuration after exiting the wizard. You can scan the QR code through the mobile surveillance App available for iOS or Android to easily view your cameras.
- Web Browser Access Through NAT Function
1. CD Go to Start→ Settings→ Network→ NAT tab. Enable NAT and select the NAT Server Address. Click “Apply” to save the parameters.
Enter www.autonat.com in the address bar of your browser and then press enter to go to the following interface. If this is the first time to access the NAT, download and install the plug-in according to the popup tips. After that, reopen your web browser and enter the above- mentioned address. Then the login box will appear. Enter the device serial number, username and password.
- Device Serial Number : Click on the menu bar at the bottom of the live interface (or go to NAT interface or System→Information→Basic interface) to view the serial number.
- Username : The username of the NVR. The default username is admin.
- Password: The password of the NVR. The password is set by yourself when you configure the wizard for the first time.
Manual Recording
Click button to start recording. Click it again to stop recording.
You can also click to check the status of the recording.
Playback
-
Instant playback
Click Instant Playback” in the right-click menu of the camera’s preview window to select or drag the playback progress bar to change the playback time to play back the record. -
General playback
Click D] on the toolbar at the bottom of the live view interface or click Start → Playback to go to the playback interface as shown below. You can also add the playback cameras manually. Click in the playback window to bring up the “Add Camera” window. Check the cameras in the window and then click “Add” to add playback camera. The recorded files of the added playback camera will be played in the playback interface.
Other Model
CONSIDER THESE OTHER GREAT TRANSCENDENT PRODUCTS
Optimize Your Surveillance System with Vitek Professional Grade Display Monitors, Designed for 24/7 Continuous Use!
-
VTM-TLM19L
Transcendent 19.5” HDMI and VGA CCTV Monitor with Full HD Display (1080P) -
VTM-TLM21L
Transcendent 21.5” HDMI and VGA CCTV Monitor with Full HD Display (1080P)
FEATURES
- 19.5” Display (VTM-TLM19L) / 21.5” Display (VTM-TLM21L)
- 16 : 9 Aspect Ratio
- Full 1080p High Def. Display (1920 x 1080) / (1600 x 900 on VTM-TLM19L)
- Contrast Ratio of 1000:1
- HDMI / VGA Input
- Audio In (2 x Speakers)
- 5ms Response Time
- 178° Horizontal and Vertical Viewing Angle (178 / 170° on VTM-TLM19L)
- LED Backlit
- 100mm VESA mount
- Professional grade display designed for 24/7 continuous use in security applications with 50,000 Hour Panel Life
- 3 Year Warranty
Also Consider Vitek Wireless Point to MultiPoint Topology to Reduce Costly Cable Installation!
VT-WAP1150 and VT-WAP2150 High Speed 5.8GHz DIP AP / CPE Wireless Bridge
with 8MB Storage, 64MB RAM, and 150MBps Transmission
With high speed transmission of 150Mbps and a wireless range of 3000 ft. (VT-
WAP1150) and 1.25 miles (VT-WAP2150) these products eliminate the need for
expensive and troublesome long distance cables in areas where CCTV monitoring
and rigorous surveillance take place. These small, lightweight and durable
units are easy to install and easy to use with an innovative and
straightforward 10-button plug-and-play dip switch that facilitates the
creation of a robust wireless network without a computer. Set-up can be simply
configured for point-to-point or point-to-multipoint topology depending on the
application, with up to 128 IP group configurations!
LIMITED PRODUCT WARRANTY
This VITEK product carries a three (3) year limited warranty. VITEK warrants to the purchaser that products manufactured by VITEK are free of any rightful claim of infringement or the like, and when used in the manner intended, will be free of defects in materials and workmanship for a period of three (3) years, or as otherwise stated above, from the date of purchase by the end user. This warranty is non transferable and extends only to the original buyer or end user customer of a VITEK Authorized Reseller.
The product must have been used only for its intended purpose, and not been subjected to damage by misuse, willful or accidental damage, caused by excessive voltage or lightning.
The product must not have been tampered with in any way or the guarantee will be considered null and void.
This guarantee does not affect your statutory rights.
Contact your local VITEK Reseller should servicing become necessary.
CLASS A DIGITAL DEVICE (INDUSTRIAL & COMMERCIAL ENVIRONMENT)
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to CE and FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct
Customer Support
PLEASE NOTE:
Complete User Guide, Software, Tools, and Updates are available online.
Scan the QR Code or visit: http://www.vitekcctv.com/Downloads
28492 CONSTELLATION ROAD VALENCIA, CA 91355
WWW.VITEKCCTV.COM
Read User Manual Online (PDF format)