Commercial Electric DMM-8300B True RMS Digital Multimeter
Product Information
True RMS Digital Multimeter Series
The DMM-8300B and DMM-8301A are reliable and accurate digital multimeters
designed for everyday troubleshooting tasks. The meters feature rugged and
robust housing for durability and come with a strong meter stand for hands-
free operation while measuring. The True RMS technology ensures accurate
voltage and current measurements, especially for complex AC signals. The DMM-
8301A model also includes a built-in temperature measurement function for
added convenience.
Product Layout
- Data hold button
- LCD Display
- FUNC (Function) selection button
- (Data hold) & (Backlight / Flashlight) button
- Rotary switch
- NCV indicator
- NCV button
- Frequency/ Duty cycle button
Specifications
Function | Measuring Range | Resolution | Accuracy |
---|---|---|---|
DC VOLTAGE SPECIFICATIONS | 200.0mV – 600V | 0.1mV – 1V | Overload Protection: |
200mV range: 250V DC Maximum Input Range:
600V DC
Product Usage Instructions
Voltage Measurement
To measure DC voltage, select the appropriate voltage range on the rotary
switch. Connect the positive input jack to the positive terminal of the
circuit under test and the COM jack to the negative terminal. Read the voltage
value displayed on the LCD.
Current Measurement
To measure DC current, set the rotary switch to the desired current range.
Connect the current leads in series with the circuit being measured. Ensure
not to exceed the maximum input current for accurate readings.
Resistance Measurement
Select the resistance range on the rotary switch. Connect the test leads to
the component or circuit under test. The meter will display the resistance
value in ohms.
Temperature Measurement (DMM-8301A only)
To measure temperature, press the corresponding function button and use the
built-in temperature measurement feature. No separate instruments are needed
for this function.
Frequently Asked Questions (FAQ)
What do I do if I encounter issues with my multimeter?
If you experience problems or have missing parts, contact Commercial
Electric Customer Service before returning the product to the store. You can
reach Customer Service at
1-877-527-0313 during the specified
hours.
EASE TO USE, RELIABILITY AND ACCURACY
Commercial Electric DMM-8300B and DMM-8301A multimeter is with rugged and
robust housing for durable use. It is also with strong meter stand,
allows you free your hand and convenient to read the measuring data during
measurement . It is your ideal meter on trouble shooting for everyday use.
ACCURACY WITH TRUE RMS TECHNOLOGY
Provides accurate voltage and current data when measuring complex AC signals.
CONVENIENT TEMPERATURE MEASUREMENTS AT YOUR FINGERTIPS (DMM-8301A ONLY)
Built-in temperature measurement function conveniently allows youto take temperature measuring without carrying separate instruments.
Your ideal trouble-shooting tools in daily use.
The Commercial Electric Manual-ranging Multimeter DMM-8300B and Auto-ranging
Multimeter DMM-8301A are True RMS Multimeter made to perfectly troubleshoot
and repair electrical and electronic systems, combined with its reliability
and accuracy. All Commercial Electric are multimeter are with True RMS
technology. It is designed for providing accurate AC voltage and current
readings in complex electrical environment which is full of non-sinusoidal
signals harmonics and variable speed drives. With True RMS technology, the
Commercial Electric mutlimeter provides reliable measurements over and over
again.
Product Layout
PRODUCT SPECIFICATIONS
DMM-8300B
Function | Measuring Range | Resolution | Accuracy |
---|
DC VOLTAGE SPECIFICATIONS
| 200.0mV| 0.1mV| ****
±(0.5% of rdg + 5 digits)
2.000V| 1mV
20.00V| 0.01V
200.0V| 0.1V
600V| 1V| ±(0.8% of rdg + 5 digits)
Overload Protection: 200mV range: 250V DC Maximum Input Range: 600V DC
AC VOLTAGE SPECIFICATIONS
| 200.0V| 0.1V| ±(1.0% of rdg + 10 digits)
600V| 1V| ±(1.2% of rdg + 10 digits)
Overload Protection: 600V RMS AC
Frequency Range: 40 – 400Hz (sine), 50/60Hz (all wave); All AC voltage ranges are
specified from 5% of range to 100% of range.
DC CURRENT SPECIFICATIONS
| 2.000mA| 1µA| ±(1.0% of rdg + 3 digits)
20.00mA| 10µA| ±(1.0% of rdg + 5 digits)
200.0mA| 100µA| ±(1.5% of rdg + 5 digits)
10A| 10mA| ±(3.0% of rdg + 10 digits)
Overload Protection: F: 10A/ 600V, F: 200mA/ 600V. Maximum Input: µA/mA
setting: 200mA DC
10A setting: 10A DC (30 sec max with reduced accuracy).
For measurements greater than 2A, the continuous time cannot be more than 2 minutes. Disconnect the current and wait 10 minutes before making another measurement.
RESISTANCE SPECIFICATIONS
| 200.0Ω| 0.1Ω| ±(1.2% of rdg + 5 digits)
2.000kΩ| 1Ω| ****
±(0.8% of rdg + 2 digits)
20.00kΩ| 0.01kΩ
200.0kΩ| 0.1kΩ
2MΩ| 0.01MΩ| ±(1.0% of rdg + 5 digits)
Overload Protection: 250V DC or 250V RMS AC
BATTERY VOLTAGE SPECIFICATIONS| 1.5V| 0.001V| 100Ω
9V| 0.01V| 450Ω
Overload Protection: F: 200mA/ 600V
DIODE AND CIRCUIT ON – OFF SPECIFICATIONS
| | Displays the approximate diode positive voltage.
| When the on-resistance is smaller than (50±30)Ω, the built-
in buzzer sounds.
□Overload Protection: 250V DC or 250V RMS AC
DMM-8301A
Function | Measuring Range | Resolution | Accuracy |
---|
DC VOLTAGE SPECIFICATIONS
| 400.0mV| 0.1mV| ****
±(0.5% of rdg + 5 digits)
4.000V| 0.001V
40.00V| 0.01V
400.0V| 0.1 V
600V| 1V| ±(0.8% of rdg + 3 digits)
Input Impedance: 10MΩ
Frequency: 50 to 60Hz
Maximum Input Voltage: 600V DC
AC VOLTAGE SPECIFICATIONS
| 4.000V| 0.001V| ****
±(0.8% of rdg + 5 digits)
40.00V| 0.01V
400.0V| 0.1V
600V| 1V| ±(1.0% of rdg + 5 digits)
Input Impedance: 10MΩ
Frequency Range: 40 – 400Hz (sine), 50/ 60Hz (all wave). All AC voltage ranges are specified
from 5% of range to 100% of range. Maximum Input Voltage: 600V AC RMS
DMM-8301A
Function | Measuring Range | Resolution | Accuracy |
---|
DC CURRENT SPECIFICATIONS
| 400.0µA| 0.1µA| ****
±(1.0% of rdg + 5 digits)
4000µA| 1µA
40.00mA| 0.01mA
400.0mA| 0.1mA
4.000A| 0.001A| ±(2.0% of rdg + 10 digits)
10.00A| 0.01A
Overload Protection: F: 10A/ 600V, F: 400mA/ 600V.
Maximum Input: µA/mA setting: 400mA DC 10A setting: 10A DC (30 sec. max with reduced accuracy)
When measured current is greater than 2A, the continuous measurement time cannot be more than 2 minutes. Disconnect the current and wait 10 minutes before you take another measurement.
AC CURRENT SPECIFICATIONS
| 400.0µA| 0.1µA| ****
±(1.2% of rdg + 5 digits)
4000µA| 1µA
40.00mA| 0.01mA
400.0mA| 0.1mA
4.000A| 0.001A| ±(2.5% of rdg + 10 digits)
10.00A| 0.01A
Overload Protection: F: 10A / 600V, F: 400mA / 600V
Frequency Range: 40 – 400Hz (sine), 50/ 60Hz (all wave). All AC current ranges are specified
from 5% of range to 100% of range.
Maximum Input: µA/mA setting: 400mA AC RMS
10A setting: 10A AC RMS (30 sec max with reduced accuracy)
For measurements greater than 2A, the continuous measurement time cannot be more than 2 minutes. Disconnect the current and wait 10 minutes before making another measurement.
RESISTANCE SPECIFICATIONS
| 400.0Ω| 0.1Ω| ****
±(0.8% of rdg + 5 digits)
4.000kΩ| 0.001kΩ
40.00kΩ| 0.01kΩ
400.0kΩ| 0.1kΩ
4.000MΩ| 0.001MΩ
40.00MΩ| 0.01MΩ
Overload Protection: 250V AC RMS or 250V DC
CAPACITANCE SPECIFICATIONS
| 50.00nF| 0.01nF| ±(5.0% of rdg + 20 digits)
500.0nF| 0.1nF| ****
±(3.0% of rdg + 5 digits)
5.000µF| 0.001µF
50.00µF| 0.01µF
500.0µF| 0.1µF
5.000mF| 0.001mF
Overload Protection: 250V AC RMS or 250V DC
FREQUENCY SPECIFICATIONS – THROUGH GRADE HZ/DUTY CYCLE
| 9.999Hz| 0.001Hz| ****
±(1.0% of rdg + 5 digits)
99.99Hz| 0.01Hz
999.9Hz| 0.1Hz
9.999kHz| 0.001kHz
99.99kHz| 0.01kHz
999.9kHz| 0.1kHz
9.999MHz| 0.001MHz
10.00MHz| 0.01MHz
Overload Protection: 250V AC RMS or 250V DC
Input Voltage Range: ≥3V AC RMS (Input voltage increases when the frequency to be
measured increases)
FREQUENCY SPECIFICATIONS – THROUGH GRADE V OR A
| 99.99Hz| 0.01Hz| ****
±(1.5% of rdg + 5 digits)
999.9Hz| 0.1Hz
9.999kHz| 0.001kHz
10.00kHz| 0.01kHz
Measuring Scope: 40Hz – 10kHz
ACA Range (≥6% Range), 4000μA/ 400.0mA Range (≥6% Range), 400.0μA/ 40.00mA/ 4.000A/ 10.00A Range (≥60% Range).
Input Impedance: 10MΩ
Maximum Input Voltage: 600V AC RMS.
DIODE SPECIFICATIONS| 3.2V| 0.001V| Display forward voltage drop of diode
Overload Protection: 250V AC RMS or 250V DC
DUTY CYCLE SPECIFICATIONS
| 0.1% – 99.9%| 0.1%| ±3.0%
THROUGH GRADE HZ/DUTY:
Frequency Response: 1 – 100.0kHz
Input Voltage Range: ≥ 3V AC RMS (Input voltage increases when the frequency to be
measured increases)
Maximum Input Voltage: 250V AC RMS THROUGH GRADE V OR A:
Frequency Response: 40 – 10kHz
ACA Range (≥6% Range), 4000μA/ 400.0mA Range (≥6% Range), 400.0μA/ 40.00mA/ 4.000A/ 10.00A Range (≥60% Range).
DIODE SPECIFICATIONS| 3.2V| 0.001V| Display forward voltage drop of diode
Overload Protection: 250V AC RMS or 250V DC
TEMPERATURE SPECIFICATIONS| -4°F – 1832°F| 1°F| ±(3.0% of rdg + 9 digits)
Overload Protection: 250V DC or 250 V AC RMS
AUDIBLE CONTINUITY SPECIFICATIONS| ****| When the on-resistance is smaller
than (50±30)Ω, the built-in
buzzer sounds. The open circuit voltage is approximately 1V.
Overload Protection: 250V AC RMS or 250V DC
INCLUDES
- Meter
- Test Leads
- 2 x AAA 1.5V Batteries
- K-Type Temperature Probe (DMM-8301A only)
- Velco Strap
- User Manual
WARRANTY
12-month
ADJUSTABLE NON-CONTACT VOLTAGE TESTER
Perfect pocket-size checking tools in daily use.
The Commercial Electric NCV-8908 adjustable non-contact voltage tester is a
easy-to-use tester made to meet the needs in dailly easy voltage checking. Its
compact design allows NCV-8908 to be easily carried in any place. IP 67 dust
and water proof design allows you to use it in a more complex envrionment.
Features
- Dual Ranges AC Voltage Detection
- Self-Test Feature
- Bright Flashlight
- Audible and Silent Mode
- IP67 Dust and Water Proof
PRODUCT SPECIFICATIONS
Content | Specifications |
---|---|
Voltage range | 12V to 1000V AC, 100V to 1000V AC, 50/60Hz |
Operating altitude | < 6560 ft. (2000 m), indoor use only |
Operating environment | 32°F to 122°F (0°C to 50°C), < 80% relative humidity, |
indoor use only.
Storage environment| 14°F to 140°F (-10°C to 60°C), < 80% relative humidity,
battery removed.
Pollute degree| 2
Safety rating| CAT IV 1000V, Class 2, double insulation.
Dimension| 5.95 X 1.02 X 1.17 in.
(151 X 26 X 29.6 mm)
Weight| Approx. 2.2 oz (63.1g), batteries included.
NON-CONTACT VOLTGAE DETECTION
Non-contact voltage detection provides safer way to detect voltage. With the
bright flashlight, easy-to read LEDs, it provides a convenient way to detect
the voltage in dim environment.
INCLUDES
- Tester
- User Manual
- 2 x AAA 1.5V Batteries
WARRANTY
12-month
OUTLET TESTER
Your ideal outlet checking tools in daily use.
The Commercial Electric OT-112 outlet tester and OTG-102 outlet tester with
GFCI is a pocket-size, easy-to-use tester made to meet the needs in outlet
checking. It is the ideal troubleshooting tool to checks each wire in the
3-wire standard outlet whether it is in properly connected to the building’s
electrical system. With the bright LEDs and refered chart on the front of the
tester, it is able to quickly identify 6 most common wiring errors of an
outlet, including reversed phase and neutral wires and an open ground. The
OT-112 and OTG-102 provides you reliable outlet detection over and over again.
One-Button GFCI test helps you work easily (OTG-102)
The GFCI test button on both socket testers allows to test the operation of
GFCI outlets. With one simple button push, the OTG-102 can quickly verify the
operating status of GFCI equipped outlet. If the GFCI trip, it means that GFCI
is normal. If not, it’s time to consult qualified electrician.
PRODUCT SPECIFICATIONS
Content | OT-112 | OTG-102 |
---|---|---|
GFCI Test | No | Yes |
AC voltage range | 125V AC, 50/60 Hz | |
Operating altitude | < 6560 ft. (2000 m), indoor use only | |
Operating environment | 32°F to 104°F (0°C to 40°C), < 80% relative humidity | |
Storage environment | 14°F to 122°F (-10°C to 50°C), < 80% relative humidity | |
Pollute degree | 2 | |
Overload voltage | CAT II 125V | |
Dimension | 3.36 X 1.76 X 1.13 in |
(85.2 X 44.8 X 28.8 mm)
| 3.36 X 1.76 X 1.30 in.
(85.2 X 44.8 X 32.9 mm)
Weight| Approx. 1.49 oz (42.1 g)| Approx. 1.52 oz (43.1 g)
SIMPLE OPERATION
Easy plug into outlet; With the bright, easy-to read LEDs, quickly identify 6
most common wiring problems in both standard and GFCI outlets.
GFCI TEST (OTG-102)
With an integrated GFCI test, easily verify whether GFCI equipped outlets are
functioning properly.
TEST FUNCTIONS
- Open ground
- Open neutral
- Open hot
- Hot/Neutral reversed
- Hot/Ground reversed
- Correct Wiring
- GFCI Test (OTG-102)
INCLUDES
- Tester
- User Manual
WARRANTY
12-month
ABOUT COMPANY
- Questions, problems, missing parts? Before returning to the store, call Commercial Electric Customer Service
- 8 a.m. – 7 p.m., EST, Monday – Friday, 9 a.m. – 6 p.m., EST, Saturday
- 1-877-527-0313
- HOMEDEPOT.COM
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>