Commercial Electric S5.5WPK-MM-BZ LED Wall Mount Pack User Guide

June 1, 2024
Commercial Electric

Commercial Electric S5.5WPK-MM-BZ LED Wall Mount Pack

Commercial Electric S5.5WPK-MM-BZ LED Wall Mount Pack

THANK YOU
We appreciate the trust and confidence you have placed in Commercial Electric through the purchase of this product. We strive to continually create quality products designed to enhance your home. Visit us online to see our full line of products available for your home improvement needs. Thank you for choosing Commercial Electric!

Safety Information

READ BEFORE INSTALLATION

  1. Follow all safeguards stated in the manual, in addition to normal safety precautions in working with electrical devices. Always follow basic safety precautions to reduce the risk of fire, electric shock and personal injury.
  2. WARNING : RISK OF SHOCK: House electric current can cause painful shock or serious injury unless handed properly. For your safety, always remember to:
    • A. Turn OFF the power supply at the fuse or circuit breaker box before you install the fixture.
    • B. Ground the fixture to avoid potential electric shocks and to ensure reliable starting.
    • C. Double check all connections to be sure they are tight and correct.
    • D. Wear rubber sole shoes and work on a sturdy ladder.
  3. This fixture is designed for use in a circuit protected by a fuse or circuit breaker. It is also designed to be installed in accordance with local electrical codes. If you are unsure about your wiring, consult a qualified electrician or local electrical inspector, and check your local electrical code.
  4. WARNING : RISK OF CUTS: Some metal parts in the fixture may have sharp edges. To prevent cuts and scrapes, wear gloves when handling the parts.
  5. Account for small parts and destroy packaging material, as these may be hazardous to children.

SAVE THESE INSTRUCTIONS.

Product Specifications

  • 120/277 VAC, 50/60Hz, 40 Watts
  • Not for use with dimmers
  • Suitable for wet locations

Dusk to Dawn Operation:
The light will turn on at dusk and remain on through the night until dawn. The light will remain off throughout the day, until dusk.
NOTE : A convenience cover (HH) is provided which can be used to block out light and bypass the sensor. This will keep the light continuous on and fixture can be controlled to turn on/off through the wall switch or a master photocell.

WARNING : These products may represent a possible shock or fire hazard if improperly installed or attached in any way. Products should be installed in accordance with the owners manual, current electrical codes and/or the current National Electric Code (NEC). Properly ground electrical enclosure. Use only UL or IEC approved wire for input/output connections.
CAUTION : To avoid risk of fire, explosion, or electrical shock, this product should be installed, inspected and maintained by a qualified electrician only, in accordance with all applicable electrical codes. Be certain electrical power is OFF before and during installation and maintenance.
CAUTION : This product must be installed in accordance with the applicable installation code by a person familiar with the construction and operation of the product and the hazards involved.

FCC STATEMENT
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:

  1. This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
    Note : This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/TV technician for help. This device complies with FCC radiation exposure limits set forth for an uncontrolled environment. This device should be installed and operated with a minimum distance of 20cm between the radiator and your body.Any changes or modifications not expressly approved by the manufacturer could void the user’s authority to operate the equipment. CAN ICES-005 (B).

ISED STATEMENT
This device complies with Industry Canada’s licence-exempt RSSs.

Operation is subject to the following two conditions:

  1. This device may not cause interference; and
  2. This device must accept any interference, including interference that may cause undesired operation of the device.

Limited Warranty
This product is warranted to be free from defects in workmanship and materials for up to 5 years from date of purchase. If it fails to do so, please contact the Customer Service Team at 1-877-527-0313.

Pre-Installation

NOTE : Hardware not shown to actual size.

TOOLS REQUIRED

PACKAGE CONTENTS

Commercial Electric S5.5WPK-MM-BZ LED Wall Mount Pack
2

Part Description Quantity
AA Wall Pack Fixture 1
BB Reflector 1
CC Lens 1
DD Reflector Screws 2
EE Lens Screws 4
FF J-Box Screws 2
GG Wire Connectors 3
HH Sensor Cover 1

Installation

  1. Turn the power OFF at the wall switch and fusebox or the circuit breaker.
  2. Remove the Fixture Lens (CC) from the Wall Pack Fixture (AA) by unscrewing the four Lens Screws (EE).
  3. Remove the Reflector (BB) from the Wall Pack Fixture (AA) by unscrewing the two Reflector Screws (DD).
  4. Use a screwdriver and hammer (not provided) to knock out the screw holes on the Wall Pack Fixture (AA) according to the J-box being used.
  5. Using Wire Connectors (GG), connect the 3 wires coming from the Wall Pack Fixture (AA) to the Junction Box Wires: Black – Line Voltage, White – Neutral, Yellow-Green or Green – Ground
  6. Feed the junction box wires and fixture wires into the Junction Box. Mount the Wall Pack Fixture (AA) to the J-Box using the two J-Box Screws (FF) through the knockout screw holes.Commercial Electric S5.5WPK-MM-BZ LED Wall Mount Pack 7
  7. Re-assemble the Reflector (BB) to the Wall Pack Fixture (AA) by screwing in the two Reflector Screws (DD).
  8. Re-assemble the Fixture Lens (CC) to the Wall Pack Fixture (AA) by screwing in the four Lens Screws (EE).Commercial Electric S5.5WPK-MM-BZ LED Wall Mount Pack 9
  9. (Optional) To bypass the Dust-To-Dawn Sensor to operate the Fixture by wall switch only, simply place the Dust-To-Dawn Sensor Cover (HH) over the Sensor.Commercial Electric S5.5WPK-MM-BZ LED Wall Mount Pack 10
  10. Turn the power ON at the wall switch, circuit breaker or fuse box.
  11. Once the fixture is tightly secured to J-Box, apply silicone sealant around the base of the fixture to prevent moisture from reaching the connections.

Operation

  • Lumen Switch
    Select the brightness: 1500, 3000 or 4000 lumens

  • CCT Switch

  • Select the color temperature:

    • 3K (3000K) – Soft White
    • 3.5K (3500K) – Neutral White
    • 4K (4000K) – Bright White
    • 5K (5000K) – Daylight
    • 6.5K (6500K) – Daylight Deluxe
  • D2D/MOT Switch
    D2D – Motion detection is disabled. Light will remain off during the day and automatically turn on at dusk.
    NOTE : A Dust-To-Dawn Sensor Cover is provided to block out light and bypass the sensor. This will keep the light on continuously and the fixture can be controlled through the wall switch or a master photocell.

  • MOT – Motion sensor is activated. Light will turn on for 10 minutes when motion is detected. During this time, brightness will be at 100% and will drop to 30% of the selected lumen if no motion is detected.

NOTE: There will be a warmup time for about 8 seconds when first powered up. Brightness will be at 100% and will then drop to 30% after the warmup time. Brightness will go to 100% once motion is detected.

Commercial Electric S5.5WPK-MM-BZ LED Wall Mount Pack
11

Care & Maintenance
Periodically clean the fixture and diffuser using a mild, non-abrasive cleaner and soft cloth. When cleaning the fixture, make sure the power is turned off. Do not spray cleaner directly onto any part of the fixture or LEDs.

Troubleshooting

PROBLEM POSSIBLE CAUSE CORRECTIVE ACTION
LED Wall Pack comes on during the day. 1.     Dusk-to-Dawn sensor is in a

shaded area and is fooled into thinking it is nighttime.

2.     Dusk-to-Dawn sensor is possibly dirty.

| 1.     Shine a flashlight onto the light sensor. If the security light turns off then the fixture is mounted in an area that does not allow enough light to enter the sensor. Relocate LED Wall Pack.

2.      Clean sensor with a damp soft cloth.

LED Wall Pack cycles ON and OFF continuously.| 1. Dusk-to-Dawn sensor is sensing reflected light from the LED Wall Pack.| 1.     Ensure no reflective materials are near to the wall pack.

2.     Relocate the LED Wall Pack to a different location where it no longer causes reflected light.

Light will not dim to 30%.| 1. Switch is position in the D2D mode.| 1. Position switch to the MOT mode.

Questions, problems, missing parts? Before returning to the store, call Commercial Electric Customer Service
8 a.m. – 7 p.m., EST, Monday – Friday, 9 a.m. – 6 p.m., EST, Saturday
1-877-527-0313
HOMEDEPOT.CA
Retain this manual for future use.

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Commercial Electric User Manuals

Related Manuals