EUROLAMP 147-29620 Gas Heater User Guide

June 15, 2024
EUROLAMP

EUROLAMP logo GAS HEATER
CIRCLE MINI
147-29620/300-42072
LFH-A-SS EUROLAMP 147-29620 Gas Heater

SAFETY RULES

CAREFULLY READ THE FOLLOWING SAFETY RULES BEFORE USE

FOR YOUR SAFETY

  1. Do not store or use gasoline or other flammable vapors and liquids near it or any other device.
  2. The Ip cylinder that s not connected for use should not be stored nearit or any other device
  3. If you smell gas:
    i. Close the gas supply.
    li. Switch off any fire hazard.
    lii. If the odor persists, call the gas supplier or the fire brigade immediately.

WARNING

  1. For use outdoors or in sufficiently ventilated areas.
  2. Asufficiently ventilated space should have at least 25% of its surface open.
  3. The total area is the sum of the wall surface.

EUROLAMP 147-29620 Gas Heater - Surface

CAUTION
Incorrect installation, adjustment, change or maintenance may cause injury or material damage. Read the instructions carefully before installing or maintaining the product.

WARNING

Read the instructions before installation and use.

  • This appliance must be installed and the gas cylinder stored in accordance with the regulations in force;

  • Do not obstruct the ventilation holes of the cylinder housing;

  • Do not move the appliance when in operation;

  • Shut off the valve at the gas cylinder or the regulator before moving the appliance;

  • The tubing or the flexible hose must be changed within the prescribed intervals;

  • Use only the type of gas and the type of cylinder specified by the manufacturer;
    The LP tank used with your patio heater must meet the following requirements: Purchase LP tanks only with these required measurements: (31.8cm) (diameter) x 58cm) (tall) with 15kg capacity maximum.

  • In case of violent wind particular attention must be taken against tilting of the appliance; Keep the appliance at least 1m from the gas cylinder.

  • The injector is installed by the manufacturer only. Do not connect the gas cylinder directly to the appliance without regulator. Use only the type of gas and the type of cylinder specified in the instructions.

Aregulator(compliees with EN16129:2013 and the national regulation) of the correct pressure corresponding to the appliance category.
Use 30mbar regulator for butane/propane under the category I38/P(30).
Use 30mbar regulator for butane under the category 13+(28-30/37).
Use 37mbar regulator for propane under the category 13+(28-30/37).
Use 50mbar regulator for butane/propane under the category 13B/P(50).
It’s reccommended to use flexible hose that approved by EN16436: 2014.

EUROLAMP 147-29620 Gas Heater - Gas Heater

PLEASE READ CAREFULLY THE FOLLOWING SAFETY GUIDELINES BEFORE OPERATION.
Do not use the patio heater for indoors, as it may cause personal injury or property damage.
This outdoor heater is not intended to be installed on recreational vehicles and/or boats.
Installation and repair should be done by a qualified service person.
Improper installation, adjustment, alteration can cause personal injury or property damage.
Do not attempt to alter the unit in any manner.
Never replace or substitute the requlator with any requlator other than the factory-suggested replacement.
Do not store or use gasoline or other flammable vapors or liquids in the heater unit.
The whole gas system, hose, requlator, pilot or burner should be inspected for leaks or damage before use, and at least annually by a qualified service person.
Allleak tests should be done with a soap solution. Never use an open flame to check for leaks.
Do not use the heater until all connections have been leak tested.a.
Turn off the gas valve immediately if smell of gas is detected. Turn Cylinder Valve OFF.If leak is at Hose/ Requlator connection: tighten connection and perform another leak test. If bubbles continue appearing should be returned to hose’s place of purchase. If leak s at Regulator/Cylinder Valve connection: disconnect, reconnect, and perform another leak check. If you continue to see bubbles after several attempts, cylinder valve is defective and should be returned to cylinder’s place of purchase.
Do not transport heater while it’s operating.
Do not move the heater after it has been turned off until the temperature has cooled down.
Keep the ventilation opening of the cylinder enclosure free and clear of debris.
Do not paint the radiant screen, control panel or top canopy reflector.
Control compartment, burner and circulation air passageways of the heater must be kept clean.
Frequent cleaning may be required as necessary.
The LP tank should be turned off when the heater is not in use.
Check the heater immediately if any of the following occurs:

  • The heater does not reach temperature.
  • The burner makes popping noise during use (a slight noise is normal when the burner is extinguished).
  • Smell of gas in conjunction with extreme yellow tipping of the burner flames.

The LP requlator/hose assembly must be located out of pathways where people may trip over it or in area where the hose will not be subject to accidental damage.
Any guard or other protective device removed for servicing the heater must be replaced before operating the heater.
Adults and children should stay away from high temperature surface to avoid burns or clothing ignition.
Children should be carefully supervised when they are in the area of the heater.
Clothing or other flammable materials should not be hung on the heater or placed on or near the heater.
To change the gas cylinder in a amply ventilated area, away from any ignition source (candle, cigarettes, other flame producing appliances, …);
To check that the requlator seal is correctly fitted and able to fulfillits function showed as photo right;
To not obstruct
the ventilation holes of the cylinder housing;
To close the gas supply at the valve of the gas cylinder or the regulator after use;
In the event of gas leakage, the appliance shall not be used or if alight, the gas supply shall be shut off and the appliance shall be investigated and rectified before itis used again;
To check the hose at least once per month, each time the cylinder is changed, or each time before long time no use.
Ifit shows signs of cracking, splitting or other deterioration it shall be exchanged for new hose of the same length and of the equivalent quality;
The use of this appliance in enclosed areas can be dangerous and is PROHIBITED;
Read the instructions before using this appliance. The appliance must be installed in accordance with the instructions and local regulations.
For connection of hose and regulator,and connection of requlator and hose, please refer to photo.

HEATER STAND AND LOCATION
The heater is primarily for outdoor use only.
Always ensure that adequate fresh air ventilation is provided. Always maintain proper clearance to non protected combustible materials i.e. top 100 «m and sides 100 cm minimum. Heater must be placed on level firm ground. Never operate heater in an explosive atmosphere like in areas where gasoline or other flammable liquids or vapors are stored. To protect heater from strong wind, anchor the base securely to the ground with screws. EUROLAMP 147-29620
Gas Heater - Gas Heater 1GAS REQUIREMENTS
Use propane, butane or their mixtures gas only.
The pressure regulator and hose assembly to be used must conform to local standard codes. The installation must conform to local codes, or in the absence of local codes, with the standard for the storage and handling of liquid petroleum gases. A dented, rusted or damaged tank may be hazardous and should be checked by your tank supplier. Never use a tank with a damaged valve connection. The tank must be arranged to provide for vapor withdrawal from the operating cylinder. Never connect an unregulated tank to the heater.

LEAKAGE TEST
Gas connections on the heater are leak tested at the factory prior to shipment. A complete gas tightness check must be performed at the installation site due to possible mishandling in shipment or excessive pressure being applied to the heater.
Make a soap solution of one part liquid detergent and one part water. The soap solution can be applied with a spray bottle, brush or rag. Soap bubbles will appear in case of a leak.
The heater must be checked with a full cylinder.
Make sure the safety control valve s in the OFF position.
Turn the gas supply ON.
In case of a leak, turn off the gas supply. Tighten any leaking fittings, then turn the gas supply on and recheck.
Never leak test while smoking.

OPERATION, STORAGE, CLEANING AND CARE

EUROLAMP 147-29620 Gas Heater - Gas Heater 2

TO TURN ON THE HEATER

  1. Turn on the valve on the gas supply cylinder completely.
  2. Press and turn the variable control knob to PILOT position (counter-clockwise 90°).
  3. Press down the variable control knob and hold for 5 seconds. While holding down the variable control knob, press the igniter button several times until the pilot flame lights. Release the variable control knob after the pilot flame lights.Note: If a new tank has just been connected, please allow at least one minute for the air in the gas pipeline to purge out through the pilot hole. When lighting the pilot flame make sure that the variable control knob is continuously pressed down while pressing the igniter button. Variable control knob can be released after the pilot flame lights. If the pilot flame does not light or it goes out, repeat step 3.
  4. After the pilot flame lights, tur the variable control knob to maximum position and leave it there for 5 minutes or more before turning the knob to desired temperature position.
    Warning: check that no broken on the glass is found before operation.

TO TURN OFF THE HEATER
A.Turn the variable control knob to PILOT position.
B. Then press and turn the variable control knob to OFF position.
C. Turn off the valve on the gas supply cylinder to shut down the heater completely.
STORAGE

  1.  Always close the gas valve of the gas cylinder after use or in case of a disturbance.
  2. Remove the pressure regulator and the hose.
  3. Check the tightness of the gas valve and for damage. If you suspect a damage, have it changed by your gas dealer.
  4. Never store liquid gas cylinder in a sub-terrain, or at places without adequate air ventilation.

CLEANING AND CARE
Wipe off powder coated surfaces with soft, moist rag. Do not lean heater with cleaners that are combustible or corrosive.
Remove debris from the burner to keep it clean and safe for use.
Cover the burner unit with the optional protective cover when the heater is not in use.

PARTS AND SPECIFICATIONS

EUROLAMP 147-29620 Gas Heater - Parts

A. Construction and characteristics
Transportable terrace/garden heater with tank housing. Casing in steel with powder-coating or n stainless steel.
Gas hose connections with metal clamp (screw caps for Germany). Heat emission from reflector.
B. Specifications
Use propane,butane or their mixtures gas only.
Max. wattage: 11000 watts
Using the proper regulator according to outlet pressure of regulator as showed in the table.
Consumption:

APPLIANCE CATEGORY: 13+(28-30/37) I3B/P(30) I3B/P(50) I3B/P(37)
TYPES OF GAS: Butane Propane Butane, propane or their mixtures Butane,
propane or their mixtures Butane, propane or their mixtures
GAS PRESSURE: 28-30mbar 37 mbar 30 mbar 50mbar

OUTLET PRESSURE
OF REGULATOR| 30mbar| 37 mbar| 30 mbar| 50mbar| 37mbar

C. Table of injector
The hose and regulator assembly must conform to local standard codes.
Regulator outlet pressure should meet the corresponding appliance category in B, Specification.
The appliance requires approved hose in 0.6m length.

APPLIANCE CATEGORY: I3+(28-30/37) I3B/P(30) I3B/P(50) I3B/P(37)
TYPES OF GAS: Butane Propane Butane, propane or their mixtures Butane,
propane or their mixtures Butane, propane or their mixtures
GAS PRESSURE: 28-30mbar 37 mbar 30 mbar 50mbar

TOTAL HEAT
INPUT (Hs): (Qn)| ti 1 kW (G30:800g/h; G31 :786g/h)
INJECTOR SIZE:| 1.75 mm for main burner 0.22 mm for pilot burner| 1.55 mm for main burner 0.22 mm for pilot burner| 1.6 mm for main bumer 0.22 mm for pilot burner
The marking, for example, 1.75 on the injector, indicates that the size of injector is 1.75mm

ASSEMBLY PARTS

TOOLS NEEDED:
Philips screwdriver w/ medium blade Spray bottle of soap solution for leakage test
PARTS LIST:

PART DESCRIPTION QUANTITY
A FLAME SCREEN GUARD 1
B BURNER ASSEMBLY 1
C (CYLINDER HOUSING 1
D BASE 1
E WHEEL 1

HARDWARE CONTENTS

| |
---|---|---
Bolt M8 x 15 Qty.2| M8 Flange nut Qty.2| Screw M8x 8 Qty.8
| |
M6 Dome nut Qty.2| Philips screwdriver| Wrench Q.1

EUROLAMP 147-29620 Gas Heater - Parts 1

ASSEMBLY PROCEDURES

  1. Use 2pcs M8X15mm bolts and M8 nuts to connect bracket with wheel to the base.EUROLAMP 147-29620 Gas Heater - Parts 8

  2. Use 4pcs M5X8 screw to join the tank housing base and stand.EUROLAMP 147-29620 Gas Heater - Parts 9

  3. Use 4pcs M5X8 screw join the burner head and tank housing body.EUROLAMP 147-29620 Gas Heater - Parts 10

  4. Use the M6 Dome Nut connect the two half safety quards to burner head.EUROLAMP 147-29620 Gas Heater - Parts 11

  5. Propane Only-Proper Hose Connection.EUROLAMP 147-29620 Gas Heater - Parts 12 WARNING! Ensure the hose does not contact any high temperature surfaces, or it may melt and leak causing a fire.
    After the cylinder is placed inside the heater, secure the cylinder with block belt tightly.
    The heater must be fixed on a stable and strong table with a minimum height of 40cm from the floor level.

  6. Leak Check
    WARNING! Aleaktest must be performed annually and each time a cylinderis hooked up orfa part of the gas system s replaced.
    WARNING! Never use an open flame to check for gas leaks. Be certain no sparks or open flames areinthe area while you check for leaks. Sparks or open flames will esult i a fire or explosion, damage to property, serious boly njury, or death.
    Leaktesting: This must be done before nitial use, annually,and whenever any gas Components re replaced or serviced. Do not smoke while performing this test, and remove all sources of ignition. See Leak Testing  Diagram for areas to check. Turn all burner controls to the off position. Turn gas supply valve on.
    Brush a half-and-half solution of liquid soap and water onto all joints and connections of the regulator, hose, manifolds and valves.
    Bubbles will indicate a gas leak. Either tighten the loose joint or have the part replaced with one recommended by the Customer Care department and have the patio heater inspected by a certified gas installer.
    If the leak cannot be stopped, immediately shut off the gas supply, disconnect t,and have the patio heater inspected by a cerified gas installer o dealer. Do not use the patio heater until theleak has been corrected.EUROLAMP 147-29620
Gas Heater - Parts 13

PROBLEMS CHECK LIST

PROBLEM PROBABLE CAUSE SOLUTION
PILOT WILL NOT LIGHT Gas valve may be OFF

Tank fuel empty
Opening blocked
Airin supply system
Loose connections| Turn the gas valve ON
Refill LPG tank
Clean or replace opening
Purge air from lines
Checkall fittings
PILOT WILL NOT STAY ON| Debris around pilot
Loose connections
Thermocouple bad
Gas leakiin line
Lack of fuel pressure| Clean dirty area
Tighten connections
Replace thermocouple
Check connections
Tank near empty. Refill LPG tank.
BURNER WILL NOT LIGHT| Pressure s low
Opening blocked
Control not ON
Thermocouple bad
Pilot light assembly bent
Notin correct location| Tank near empty.Refill LPG tank
Remove and clean
Tum valve to ON
Replace thermocouple
Place pilot properly
Position properly and retry

If the appliance is in case of any defaults or problems of assembly or use, please don’t try to modify it by yourself, contact your supplier or distributor to solve it.

CORRECT DISPOSAL OF THIS PRODUCT
This marking indicates that this roduct should notbe disposed it other household wastes throughout the EU. To prevent possible ham to th environment o human healthfiom uncontrlled waste isposa, ecyde it respnsiby to promotethe sustainabl euse of mateialresources.To eturn you used devce, please us th returnand cllectionsystes or contac theretale where the product was purchased. They can taketis produc o environmental e recyling.

EUROLAMP logo * IMPORTED IN EU BY EUROLAMP SA:
KAMPOS DIAVATA -IONIA/ 57008 / THESSALONIKI
GREECE /T: +30 2310 574802
MADE IN CHINA
[email protected]
www.eurolampglobal.com

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

EUROLAMP User Manuals

Related Manuals