Installation Guide
Installation notes
| For safe installation and commissioning of the dishwasher please read the
installation plan, the service documentation, the
installation sheet and the operating instructions.
This installation plan includes the dimensions of the appliance, the technical
data and the requirements to be met on site for the
installation of the dishwasher.
---|---
Installation requirements| This dishwasher must only be installed and
commissioned by the Miele Customer Service Department, a Miele authorised
dealer or a suitably qualified specialist.
Installation should only be performed in accordance with valid regulations,
relevant standards and health and safety codes.
Environmental requirements| Condensate can build up in the area surrounding
the dishwasher. Any furniture and fittings in the room must therefore be
suitable for purpose.
Vapour barrier film
for built-in appliances| The vapour barrier film supplied protects the worktop
from damage caused by steam when the door is opened. Attach the vapour barrier
film above the door, underneath the worktop.
Electrical connection| All work on the electrical connection must be carried
out by the Miele Customer Service Department, an authorised Miele dealer or a
qualified electrician.
Plug connection| The dishwasher should be connected to the electricity supply
via a suitably rated plug and socket.
Hard-wired| If the dishwasher is hard-wired to the power supply, a power
switch capable of disconnecting the dishwasher at all poles must be
installed on site. This power switch must have a contact gap of at least 3 mm.
The means for disconnection must be incorporated in the fixed wiring in
accordance with the wiring rules AS/NZS 3000.
The socket and the power switch must be accessible after the appliance has
been installed. An electrical safety test can then easily
be carried out, e.g., after any service or maintenance work.
The connection cable must be protected from the risk of thermal damage.
Residual current device (RCD)| For increased safety, it is recommended to
protect the dishwasher with a residual current device (RCD) with a trip
current of 30 mA.
Equipotential bonding| There is a screw connection point for equipotential
bonding at the back of the dishwasher.
Equipotential bonding should be carried out if possible on site.
Water connection| The dishwasher must only be connected to fully vented
pipework.
A brief increase in the water pressure can damage components of the
dishwasher.
Water inlet| The quality of the incoming water must correspond to the drinking
water specification of the country in which the dishwasher is being operated.
The dishwasher must be connected to the water supply in strict accordance with
current local and national requirements (e.g.
Plumbing Code of Australia (PCA)). It can be connected to cold or hot water
supplies. Connecting the dishwasher to a hot water supply will reduce
programme running times.
For short programme running times, dynamic water pressure of at least 200 kPa
is also required.
This appliance must be installed according to AS/NZS 3500.1 and AS/NZS 3500.2.
This dishwasher has been supplied with a
separate backflow prevention device (dual check valve).
Installation requirements:
The dual check valve supplied separately with this product must be installed
between the tap and the water inlet hose.
Screw the dual check valve onto the tap. Then screw the water inlet hose with
the water protection system onto the thread of the dual check valve.
Turn on the the tap gradually to test for leaks. If there is a leak, the
connection might not be on securely, or it may have been screwed on at an
angle. Unscrew and reconnect the water correctly before tightening it.
If a tap is not available, only a qualified installer may connect the
dishwasher to the mains water supply.
The tap should remain accessible once the dishwasher has been installed so
that the water supply can be shut off whenever the
appliance is not in use.
Drain| The dishwasher drain hose should be connected to a separate on-site
drainage system for the dishwasher only. If a separate connection is not
available, we recommend connecting the hose to a dual-chamber siphon.
If the hose is to be fitted directly to the drainage system on site, use the
hose clip supplied with the dishwasher.
The on-site connector for the drain hose can be adapted to different hose
diameters. If the connector extends more than 30 mm into the drain hose, it
must be shortened. Otherwise, the drain hose can become blocked.
Lay the drain hose so that it does not kink and is not being subjected to
pressure or tension.
If the on-site drain connection is situated lower than the guide path for the
lower basket rollers in the open door, a siphoning effect during a programme
can cause the wash cabinet to empty itself of water.
In this case, lay the drain hose with a bend in it so that its highest point
is at least level with the guide path for the lower basket rollers.
External dispensing| An external dispensing module for liquid cleaning agents
can be connected to the back of the dishwasher.
The dispensing module is available as an optional accessory and is supplied
with installation instructions.
Appliance dimensions and installation dimensions
PFD 104 SCVi
Front panel dimensions
Length | [mm] | 690–810 |
---|---|---|
Thickness | [mm] | 16–20 |
Weight | [kg] | 5–12 |
Connections
Connections on the back of the appliance
- Electrical connection
- External dispensing, power supply connection
- Equipotential bonding
- Waste water
- Cold or hot water
- External dispensing, connection for dispensing hose sealed with a blind stopper*
- the dispenser connector is supplied with the dispensing module
External dispensing
Max. delivery head | [m] | 1.5 |
---|---|---|
Length of dispenser hose, DOS module to suction lance | [m] | 1.8 |
Length of dispenser hose, back of appliance to DOS module | [m] | 2.8 |
Length of power cable, back of appliance to DOS module | [m] | 2.8 |
Technical data
Dimensions and weights
Height | [mm] | 845 |
---|---|---|
Height adjustment | [mm] | 65 |
Width | [mm] | 598 |
Depth | [mm] | 570 |
Depth with door open | [mm] | 1205 |
Max. plinth return | [mm] | 115 |
Weight | [kg] | 51 |
Max. floor load | [N] | 1000 |
Emission levels
Sound power level | [dB(A) re 1 pW] | 45 |
---|---|---|
Sound pressure level in the workplace | [dB(A)] | 32.5 |
Electrical connection
Standard electrical connection
Voltage | AC 230V | |
---|---|---|
Frequency | [Hz] | 50 |
Fuse rating | [A] | 15-16 |
Plug | Yes | |
Power cable length | [m] | 1.7 |
Power cable cross-section | [mm²] | 3×1.5 |
Heat output | [kW] | 3 |
Total rated load | [kW] | 3.2 |
Water inlet
Max. water temperature | [°C] | 60 |
---|---|---|
Max. water hardness | [mmol/l] | 6.5 |
Max. water hardness | [°dH] | 36 |
Water connection pressure | [kPa] | 50–1000 |
On-site threaded union
(flat seal)| [inches]| 4-Mar
Connection hose length| [m]| 1.5
Drain
Max. water temperature | [°C] | 82 |
---|---|---|
Drain hose length | [m] | 1.5 |
Max. drain hose length | [m] | 4 |
Max. delivery head | [m] | 1 |
Max. transient flow rate | [l/min] | 10 |
Hose inner diameter | [mm] | 22 |
On-site hose sleeve (∅ x length) | [mm] | 22 x 30 |
Operating conditions
Ambient temperature | [°C] | +5 – +40 |
---|
Relative humidity:
Up to 31 °C, maximum
Linear decreasing to 40 °C| [%] [%]| 80
50
Max. altitude above sea level up to| [m]| 4000
Storage and transportation conditions
Ambient temperature | [°C] | -20 – +60 |
---|---|---|
Relative humidity | [%] | 10–85 |
Air pressure | [hPa] | 500–1060 |
Min. site access dimensions including transport pallet
Height | [mm] | 970 |
---|---|---|
Width | [mm] | 670 |
Depth | [mm] | 670 |
Miele Australia Pty. Ltd.
ACN 005 635 398
ABN 96 005 635 398
Melbourne: 1 Gilbert Park Drive
Knoxfield, VIC 3180
Telephone: 1300 731 411
service.prof@miele.com.au
www.miele.com.au/professional
sales@miele-professional.com.au
Miele New Zealand Limited
IRD 98 463 631
8 College Hill
Freemans Bay
Auckland 1011
New Zealand
Telephone: 0800 4 MIELE
(0800 464 353)
www.miele.com.au/professional
sales@miele-professional.com.au
Miele Global Headquarters: Miele & Cie. KG
**Carl-Miele-Straße 29, 33332 Gütersloh, Germany
Alteration rights reserved / Publication date: 2021-07-01
M.-Nr. 11 681 590 / 01
**
References
- Miele Professional AU | Discover our Commercial Solutions
- Miele Professional AU | Discover our Commercial Solutions
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>